benzblogs Vlogs
benzblogs Vlogs
  • Видео 353
  • Просмотров 679 200
SOLAR INVERTER AND GENERATOR SYNCHRONIZING EXPLAIN
SOLAR INVERTER AND GENERATOR SYNCHRONIZING EXPLAIN
Просмотров: 123

Видео

DG PARALLELING 650KVA 6 UNITS
Просмотров 34121 день назад
These videos show how hard it is to prepare for cabling in synchronising, while working in Gcc country the temperature 🌡️ is burning but this can not be the hindrance to succeed to our project, i hope you enjoy watching Godbless us all.
HOW TO TROUBLESHOOT AND REMOVE 1206 PRIME PUMP
Просмотров 29921 день назад
In this video where i show you is more on checking,removing and installing this pump how to make it easy and what are those things we remove first.
1206 engine synchro project sucess
Просмотров 17128 дней назад
This video is a showcase of synchronizing 1206 engine and leroy alt using 8610 module for this project
FACTORY LOAD TESTING 770 kva and inductive load bank
Просмотров 76Месяц назад
In this video just show you how we prepare for fat using a induction loadbank and 770 kva generator set
1125kva fat test
Просмотров 67Месяц назад
Fastest success
GOODWE Green operating indicators explain
Просмотров 43Месяц назад
In this video explain the function and the status of the green light blinking from the buttons that we seen in the solar inverter
HOW TO PREPARE AND DO MAINS GRID SYNCHRONIZING
Просмотров 807Месяц назад
In this video I explain the preparation and the module type, how it will work in the actual condition, and also I explain the breaker which is the mains breaker, bus breaker, generator breaker who's is controlling with this and what are the configuration needed for this grid sync
HOW TO IDENTIFY PERKINS SERIAL NUMBER
Просмотров 79Месяц назад
HOW TO IDENTIFY PERKINS SERIAL NUMBER
HOW TO FIX FAIL TO OPEN BREAKER AND PREPARE SYNCHRO 500KVA
Просмотров 313Месяц назад
HOW TO FIX FAIL TO OPEN BREAKER AND PREPARE SYNCHRO 500KVA
How to install muffler cladding
Просмотров 622 месяца назад
How to install muffler cladding
PERKINS 4012 SERIES ECM CONFIGURATION AVR CONFIGURATION LOAD TESTING PART-2
Просмотров 1592 месяца назад
PERKINS 4012 SERIES ECM CONFIGURATION AVR CONFIGURATION LOAD TESTING PART-2
PERKINS 4012 SERIES ENGINE LOOM INSTALLATION AVR CONFIGURATION DSE CONGRATULATIONS LOAD TESTING
Просмотров 1362 месяца назад
PERKINS 4012 SERIES ENGINE LOOM INSTALLATION AVR CONFIGURATION DSE CONGRATULATIONS LOAD TESTING
INSTALLATION OF L-SERIES IN 1104C PERKINS ENGINE
Просмотров 3412 месяца назад
INSTALLATION OF L-SERIES IN 1104C PERKINS ENGINE
HOW TO ADJUST SPEED TO 1800 RPM AND 240VAC USING R120 AVR
Просмотров 4182 месяца назад
HOW TO ADJUST SPEED TO 1800 RPM AND 240VAC USING R120 AVR
CONFIGURATION 7SETS OF DSE890 WITH 6120 DSE MODULE
Просмотров 1692 месяца назад
CONFIGURATION 7SETS OF DSE890 WITH 6120 DSE MODULE
45KVA WITH AUTOMATIC TRANSFER SWITCH LETS SIMPLIFY
Просмотров 2823 месяца назад
45KVA WITH AUTOMATIC TRANSFER SWITCH LETS SIMPLIFY
110% LOAD TEST USING CONTAINERIZED INDUCTION LOAD BANK
Просмотров 3433 месяца назад
110% LOAD TEST USING CONTAINERIZED INDUCTION LOAD BANK
breaker troubleshooting 300kva synchronizing and ECU fail
Просмотров 1,4 тыс.4 месяца назад
breaker troubleshooting 300kva synchronizing and ECU fail
GENERATOR LOAD TESTING 1250KVA WITH 350 DIGITAL AVR AND HEINZ MANN GOVERNOR AND TROUBLESHOOTING
Просмотров 5414 месяца назад
GENERATOR LOAD TESTING 1250KVA WITH 350 DIGITAL AVR AND HEINZ MANN GOVERNOR AND TROUBLESHOOTING
HOW TO TEST GENERATOR EARTH LEAKAGE SHUTDOWN
Просмотров 6735 месяцев назад
HOW TO TEST GENERATOR EARTH LEAKAGE SHUTDOWN
SYNCHRO TESTING 300kva and 500kva with the customer
Просмотров 1985 месяцев назад
SYNCHRO TESTING 300kva and 500kva with the customer
LSA ALTERNATOR 1500KVA WITH PERKIN'S ENGINE LOAD TEASING AT 100%
Просмотров 3795 месяцев назад
LSA ALTERNATOR 1500KVA WITH PERKIN'S ENGINE LOAD TEASING AT 100%
AIR SHUTOFF VALVE OR CHALWYN VALVE INSTALLATION AND CALIBRATION
Просмотров 2725 месяцев назад
AIR SHUTOFF VALVE OR CHALWYN VALVE INSTALLATION AND CALIBRATION
DIODE RECTIFIER ASSEMBLY WIRING CONNECTION AND MODIFICATIONS SIMPLIFY
Просмотров 2875 месяцев назад
DIODE RECTIFIER ASSEMBLY WIRING CONNECTION AND MODIFICATIONS SIMPLIFY
UNDER VOLTAGE SHUTDOWN POSSIBLE CAUSES OF THE PROBLEM? part1
Просмотров 2,6 тыс.5 месяцев назад
UNDER VOLTAGE SHUTDOWN POSSIBLE CAUSES OF THE PROBLEM? part1
Automatic Air ventilation louver wiring and configuration
Просмотров 1746 месяцев назад
Automatic Air ventilation louver wiring and configuration
SWIMMING TIME Mamzar Beach
Просмотров 536 месяцев назад
SWIMMING TIME Mamzar Beach
hanging garden kalba sarjah
Просмотров 766 месяцев назад
hanging garden kalba sarjah
800kva Perkins engine with Leroy somer alternator load testing 4 sets of generator
Просмотров 2726 месяцев назад
800kva Perkins engine with Leroy somer alternator load testing 4 sets of generator

Комментарии

  • @shihamshibly507
    @shihamshibly507 7 часов назад

    After replacing the same with a new battery

  • @shihamshibly507
    @shihamshibly507 7 часов назад

    Deepsea DSE7320 memory corrupt issue. There is a small battery inside the module & the memory corrupt issue got successfuly got solved

    • @shihamshibly507
      @shihamshibly507 7 часов назад

      After replacing with a new battery

    • @benzblogsVlogs
      @benzblogsVlogs Час назад

      There is two type can cause memeory currept one is by mitakes during programing ang one is the clock battery

  • @shihamshibly507
    @shihamshibly507 7 часов назад

    Where can I purchase displays of the Deepsea modules

  • @chocopam_01
    @chocopam_01 20 часов назад

    Napakahusay nyo naman idol. Thanks for the share. All done na po here🙂🌻

  • @chocopam_01
    @chocopam_01 2 дня назад

    Thanks for the share. So informative. Bgung fren ako🌻🙂

  • @benzblogsVlogs
    @benzblogsVlogs 2 дня назад

    You know what is your freq itger 50/60 and voltage,and you config change to single phase line to line

  • @ahmedsheikaliadan6023
    @ahmedsheikaliadan6023 3 дня назад

    On hands

  • @jubsofficialvlog1473
    @jubsofficialvlog1473 3 дня назад

    Nice one lods Ikaw na talaga ingat

  • @welding.electronictech531
    @welding.electronictech531 3 дня назад

    Hello sir perkins po, ayaw mag start, tapos may warming fault high frequency at high rpm, possible kaya speed sensor ang sira, tester ko terminal may resistance reading na 140 ohms

    • @benzblogsVlogs
      @benzblogsVlogs 3 дня назад

      Ganito gawin mo sir check nyo mona ang andar ng engine kong normal po bago ka mg check sa voltage kong di normal check mo kong my lseries or check mo injection pump

  • @elementalwattson
    @elementalwattson 3 дня назад

    Hi! I have an alarm: "BOC Gen J unbal" What is that mean and which is the possible cause?

  • @heavymkwananzi8216
    @heavymkwananzi8216 3 дня назад

    Confirm, can this conversion works on DSE 6120mklll control module, and what other things needed changed to make a successful conversion , for example do you change AVR Type, CTs etc

    • @benzblogsVlogs
      @benzblogsVlogs 3 дня назад

      Yea 110% yes you should avr connection and module config

    • @heavymkwananzi8216
      @heavymkwananzi8216 2 дня назад

      @@benzblogsVlogs thank you so much for the info, nevertheless, what else would you advice me espacially when it comes to configurations, something that l musten miss, l will be going on site probably next week, therefore, l get back to you when l experience some issues 🙏🙏

    • @benzblogsVlogs
      @benzblogsVlogs 2 дня назад

      @@heavymkwananzi8216 welcome

  • @jubsofficialvlog1473
    @jubsofficialvlog1473 4 дня назад

    Nice lods ayos

  • @xoxonaed6263
    @xoxonaed6263 4 дня назад

    Hai sir, does this software need to pay yearly subscription to use?

    • @benzblogsVlogs
      @benzblogsVlogs 4 дня назад

      Big no all free just always update your account in the dse

    • @xoxonaed6263
      @xoxonaed6263 3 дня назад

      @@benzblogsVlogs thank you for the clarification..

  • @tifeukouivefranclin6381
    @tifeukouivefranclin6381 4 дня назад

    Good morning! Thank you for the content you provide. However, I have one concern. I have just installed a generator managed by the DSE 6120MKIII. when I turn it on in auto mode it starts directly so the remote start wire is not connected. What could be the cause please.

    • @benzblogsVlogs
      @benzblogsVlogs 4 дня назад

      Because your not disable the auto mains fail that y its start directly

    • @benzblogsVlogs
      @benzblogsVlogs 4 дня назад

      Check in my yt ruclips.net/video/kP_kJVfM998/видео.htmlsi=ZK2B_qwrw3VEr9fG

    • @tifeukouivefranclin6381
      @tifeukouivefranclin6381 3 дня назад

      Merci infiniment. Justement le ''défaut secteur'' était activé. Merci encore Monsieur

  • @tifeukouivefranclin6381
    @tifeukouivefranclin6381 4 дня назад

    Good morning! Thank you for the content you provide. However, I have one concern. I have just installed a generator managed by the DSE 6120MKIII. when I turn it on in auto mode it starts directly so the remote start wire is not connected. What could be the cause please.

    • @benzblogsVlogs
      @benzblogsVlogs 4 дня назад

      Hi just disable the auto mains fail to work as what remotebu need to work too

  • @voiceofshahzad973
    @voiceofshahzad973 4 дня назад

    You should not play music in back ground of the video

    • @benzblogsVlogs
      @benzblogsVlogs 4 дня назад

      Yes that my old vid now no background music

    • @voiceofshahzad973
      @voiceofshahzad973 4 дня назад

      @@benzblogsVlogs Thanks bro I appreciate you of such respons good luck.

  • @МарянМірило
    @МарянМірило 5 дней назад

    Hi sir! In this your video for synchro you use leroy somer R450. How it is posible if we haven't analog input on avr. There are two terminal for potentiometer(1 kOmh). ruclips.net/video/5pqhL_xJCqM/видео.htmlsi=hQaiMDBYgJibxZzu

  • @MundrikaSharma
    @MundrikaSharma 6 дней назад

    Please bro give me the program of frequency

    • @benzblogsVlogs
      @benzblogsVlogs 6 дней назад

      Program or settings

    • @MundrikaSharma
      @MundrikaSharma 6 дней назад

      Thanks for replying me bro Ihave 6110 mou 4.1 version I need frequency program Becosee my generator showing under frequency shootdown Please helm me bro

    • @benzblogsVlogs
      @benzblogsVlogs 6 дней назад

      Check first what is your frquency nominal before we can do a program

    • @MundrikaSharma
      @MundrikaSharma 6 дней назад

      Frequency showing 50.7

    • @MundrikaSharma
      @MundrikaSharma 6 дней назад

      When the generator is running frequency showing 50.7

  • @riftvalley1765
    @riftvalley1765 7 дней назад

    You belong in a kitchen cooking a rice! Nowhere near a generator!

  • @МарянМірило
    @МарянМірило 8 дней назад

    Hi. Could you help me with this question? I am preparing to synchronize two generators. For this, it was advised to use avr Leroy Somer R450. Do I need to connect the analog output of the DSE8610 panel (0-5V) instead of a potentiometer (on the 1k ohm circuit)?

  • @hayhas2561
    @hayhas2561 8 дней назад

    When you loaded the genset, what you've in the display to keep eyes on it , to now the test is pass or not ,Is it volt or current or freq ?

    • @benzblogsVlogs
      @benzblogsVlogs 8 дней назад

      Its always depend on the kva/kw this how to pit load to your generator

  • @LaljiSorthiya-y5i
    @LaljiSorthiya-y5i 9 дней назад

    Good job

  • @kevinlundberg9601
    @kevinlundberg9601 9 дней назад

    I am struggling with two issues. The first is the actual pins on my HGN6120NC controller I connect with a two wire remote start system. The second is how to wire a preheater to the controller. What pins on the controller will send a 12 volt power to a relay that can then feed the battery power to my preheater during the preheater phase of the starting procedure?

    • @benzblogsVlogs
      @benzblogsVlogs 8 дней назад

      Go to digital ouput config preheatduri g preheat timer add one relay for your sw 12 vdc goingvtobyour heater

    • @kevinlundberg9601
      @kevinlundberg9601 7 дней назад

      @@benzblogsVlogs Thank you for the information. I did get the preheater sorted out with your help. However, I am still having a difficult time figuring out how to connect the HGN6120NC controller to a two wire remote start. I am off-grid and it seems to need a mains power to go out for a remote start to function. Is there any way around this?

    • @kevinlundberg9601
      @kevinlundberg9601 7 дней назад

      ...In other words, without a mains power source (an off-grid system) is there any way to remotely start and stop an HGN6120NC controller with a two wire remote start system?

  • @jinglingao-lingao5153
    @jinglingao-lingao5153 10 дней назад

    Idol pag ganyan ba alarm fail to close nasa supply lang ba ang issue?

    • @benzblogsVlogs
      @benzblogsVlogs 10 дней назад

      Dependi lods maraming pweding causes Isa najan Ang supply,configuration,relay ,wiring connection Yan Ang mga pweding dahilan Ng alarms Kaya di gumana

    • @jinglingao-lingao5153
      @jinglingao-lingao5153 10 дней назад

      ​@@benzblogsVlogsok naman ang relay ,wirings, dapat ba naka off position yong breaker bago mo salpak ang motor control mod.

    • @benzblogsVlogs
      @benzblogsVlogs 10 дней назад

      @@jinglingao-lingao5153 pwedi g naka off pwedi g naka trip ang titignan mo jan kong pomasok ng tama doon sa handle ng breaker para gomana ng maayus lods

    • @jinglingao-lingao5153
      @jinglingao-lingao5153 10 дней назад

      ​@@benzblogsVlogssalamat idol... 👍

  • @jubsofficialvlog1473
    @jubsofficialvlog1473 10 дней назад

    Nice sharing lods gandang umaga Dito jehehhe

  • @MesumbeAmstrongEboa-w1i
    @MesumbeAmstrongEboa-w1i 10 дней назад

    How resolve the fault Digital input A,B,C,D, E,F,H,,what can really be the cause

  • @louieschena
    @louieschena 10 дней назад

    Hi there, can u help with how to control the screen contrast ?

  • @MOJUSA
    @MOJUSA 11 дней назад

    Great job Thanks for sharing 😊

  • @jubsofficialvlog1473
    @jubsofficialvlog1473 11 дней назад

    Ganda puro brand new lods

  • @jubsofficialvlog1473
    @jubsofficialvlog1473 11 дней назад

    Iba talaga Ang talent no lods

    • @benzblogsVlogs
      @benzblogsVlogs 11 дней назад

      Try lods ng maiba naman hehehe Godbless lods

  • @heavymkwananzi8216
    @heavymkwananzi8216 11 дней назад

    Hello, I urgently need your help. I have a DSE 6020mklll generator, currently configured for three-phase 400V. I want to change it to three-phase 230V. Please provide step-by-step guidance on how to confirm the changes on the DSE controller after modifying the starter connection to a delta connection. Additionally, please advise on how to configure the cooldown time after manually switching off the generator. Note: It's a 30kW 12 Leads generator.; I hope you can assist me here.

  • @heavymkwananzi8216
    @heavymkwananzi8216 11 дней назад

    Hello, I urgently need your help. I have a DSE 6020mklll generator, currently configured for three-phase 400V. I want to change it to three-phase 230V. Please provide step-by-step guidance on how to confirm the changes on the DSE controller after modifying the starter connection to a delta connection. Additionally, please advise on how to configure the cooldown time after manually switching off the generator. Note: It's a 30kW 12 Leads generator.; I hope you can assist me here.

  • @pradeepnair9286
    @pradeepnair9286 13 дней назад

    How to set CAN ID

    • @benzblogsVlogs
      @benzblogsVlogs 13 дней назад

      You need to use laptop and if you have sofeware thin you can just finf the can and there you will see all

    • @pradeepnair9286
      @pradeepnair9286 13 дней назад

      @@benzblogsVlogs In AGC 4, these alarms are there Miss all units Any DG missing CAN ID IP missing, I have laptop with software 3

  • @mariokhoury6412
    @mariokhoury6412 15 дней назад

    Dear Sir are you sure the baseload setpoint is used when genset work in stand alone? and loadshare when is working in paralallel? I have read the manual i found different explication or I mis understood

    • @benzblogsVlogs
      @benzblogsVlogs 15 дней назад

      Load is always depend on kva however if this is synchro it double up the capacity dur to share load right ?

  • @prekshachaudhary1262
    @prekshachaudhary1262 15 дней назад

    Amazing😮

  • @MiraJohn1208
    @MiraJohn1208 15 дней назад

    ❤❤❤

  • @jubsofficialvlog1473
    @jubsofficialvlog1473 16 дней назад

    Kinis Ng makina lods bago talaga

  • @jubsofficialvlog1473
    @jubsofficialvlog1473 16 дней назад

    Nice lods

  • @quangvuhai8194
    @quangvuhai8194 18 дней назад

    Do you make woodward easygen

  • @anrchannel498
    @anrchannel498 20 дней назад

    How to get download aplication L-Series Service Toool And install this aplication in laptop?

    • @benzblogsVlogs
      @benzblogsVlogs 19 дней назад

      Go to woodward chrck the cotumer service

  • @jubsofficialvlog1473
    @jubsofficialvlog1473 20 дней назад

    Nice lods

  • @jubsofficialvlog1473
    @jubsofficialvlog1473 20 дней назад

    Morning lods

  • @frankbrown3899
    @frankbrown3899 20 дней назад

    Where can I locate load wire on jp20 generator

    • @benzblogsVlogs
      @benzblogsVlogs 20 дней назад

      Load wire you mean for load connection? Its in the breaker

  • @abdijama9108
    @abdijama9108 20 дней назад

    how to get deapsea 7320 pincode

    • @benzblogsVlogs
      @benzblogsVlogs 20 дней назад

      Dse pin try 0000 or 1234

    • @abdijama9108
      @abdijama9108 20 дней назад

      @@benzblogsVlogs it does not work even i tried 0000, 0101, 1010, 1234

  • @mauriceamollo8538
    @mauriceamollo8538 21 день назад

    Can this generator be used to power house holds like tvs and other exesories like computer,fridge and lights because i dont see neutral terminals here..only L1,L2 is there??

    • @benzblogsVlogs
      @benzblogsVlogs 21 день назад

      Yes even in big imduatry it is

    • @benzblogsVlogs
      @benzblogsVlogs 21 день назад

      That single phase line to line not line to nutral

    • @mauriceamollo8538
      @mauriceamollo8538 21 день назад

      @benzblogsVlogs which means that alternator is now a split phase 220v or 2 phase 220v not single phase?

    • @mauriceamollo8538
      @mauriceamollo8538 21 день назад

      @@benzblogsVlogs so a machine rated 220v line to neutral can still operate with 220v line to line without any problem sir?

  • @mauriceamollo8538
    @mauriceamollo8538 21 день назад

    Sir why is it not single phase L_N because it is written L1, L2 220v.is both terminals live?

  • @ahmedsheikaliadan6023
    @ahmedsheikaliadan6023 22 дня назад

    thanks for sharing

  • @jubsofficialvlog1473
    @jubsofficialvlog1473 22 дня назад

    Nice lods it's watching time lods ingat

  • @samuelkahiga-sx4wd
    @samuelkahiga-sx4wd 22 дня назад

    Can you do a video plz on how to calculate reverse power

  • @samuelkahiga-sx4wd
    @samuelkahiga-sx4wd 22 дня назад

    Hello sir ...thanks you always for your informative videos... can you kindly do a video on mains synchronisation and explain step by step the whole program coz thats where i got a ploblem in.

    • @benzblogsVlogs
      @benzblogsVlogs 22 дня назад

      If i dont have comapany i working for i will do the problem is it confidencial campany rules but if u need help i can assist you thanks i hope you anderstand pls dont be angry

    • @samuelkahiga-sx4wd
      @samuelkahiga-sx4wd 21 день назад

      @@benzblogsVlogs thank you sir..i will ask you for any question just incase i get a ploblem

    • @benzblogsVlogs
      @benzblogsVlogs 21 день назад

      @@samuelkahiga-sx4wd wc