- Видео 53
- Просмотров 1 387 768
Birmingham Boiler Repairs
Добавлен 29 янв 2014
It's easy once you know how
how to fit a ferroli sky eco water heater
fit the ferroli water heater like this basically a place where you buy food from
15mm full flow non return valve
2 15mm shock arrestors
Haven't had one problem to date
15mm full flow non return valve
2 15mm shock arrestors
Haven't had one problem to date
Просмотров: 2 109
Видео
ferroli bluehelix full factory reset
Просмотров 15 тыс.Год назад
this is useful if you discover the readings are very very high.Reset the circuit board then turn off the boiler for 10 seconds turn it back on with the shortcut .Then recalibrate the gas valve if the readings are still high and call the manufacturer. 137 ppm 9.3 co2 is pretty normal
ferroli bluehelix factory reset
Просмотров 18 тыс.Год назад
factory reset.This would reset some faults like temperature problems , no hot water no symbol for the tap , temperature problems, f40 , A61 always check the condense isnt blocked first
how to do a factory reset on a Ferroli bluehelix hi-tech
Просмотров 2,8 тыс.Год назад
how to do a factory reset on a Ferroli bluehelix hi-tech
wiring on a ferroli blue helix Hi-tech @theferroliman2067
Просмотров 383Год назад
wiring on a ferroli blue helix Hi-tech @theferroliman2067
test mode on a ferroli blue helix Hi-tech @thrferroliman2067
Просмотров 126Год назад
test mode on a ferroli blue helix Hi-tech @thrferroliman2067
ferroli blue helix Hi-tech parameters
Просмотров 1,2 тыс.Год назад
ferroli blue helix Hi-tech parameters
how to use a ferroli blue helix Hi-tech
Просмотров 2,8 тыс.Год назад
how to use a ferroli blue helix Hi-tech
Ferroli bluehelix test mode and calibration
Просмотров 4,8 тыс.3 года назад
Ferroli bluehelix test mode and calibration
ferroli bluehelix squeaking noise adjustment
Просмотров 1,5 тыс.3 года назад
ferroli bluehelix squeaking noise adjustment
Ferroli bluehelix LPG set up and calibration
Просмотров 5 тыс.3 года назад
Ferroli bluehelix LPG set up and calibration
How replace a Ferroli optimax diverter valve
Просмотров 2,5 тыс.3 года назад
How replace a Ferroli optimax diverter valve
How to enter the parameters on the Ferroli bluehelix
Просмотров 7 тыс.3 года назад
How to enter the parameters on the Ferroli bluehelix
Ferroli bluehelix power on short cut
Просмотров 13 тыс.3 года назад
Ferroli bluehelix power on short cut
How to recharge an expansion vessel on a Ferroli bluehelix
Просмотров 1,6 тыс.3 года назад
How to recharge an expansion vessel on a Ferroli bluehelix
How to top up the pressure on a Ferroli boiler with external filling loop
Просмотров 11 тыс.3 года назад
How to top up the pressure on a Ferroli boiler with external filling loop
How to remove a Ferroli condense trap
Просмотров 1,3 тыс.3 года назад
How to remove a Ferroli condense trap
How to use a Ferroli Modena HE boiler
Просмотров 134 тыс.10 лет назад
How to use a Ferroli Modena HE boiler
how to use a Ferroli boiler ,optimax 25c
Просмотров 5 тыс.10 лет назад
how to use a Ferroli boiler ,optimax 25c
how to repressurise a Ferroli boiler
Просмотров 220 тыс.10 лет назад
how to repressurise a Ferroli boiler
You set your central heatin up to 68 degree but I can see it's only 38 degree and not heating up. What's up with it? I have recently bought Ferolli Bluehelix and I experience something similar. I set the temperature to 32, it heats up for a while, then the temp go down to 28 degree and it's not going up In addition water that's coming out and in is the same temperature as system says. What's going on?
Hi can you do a video on flue parameters and explain what the settings are equivalent to I.e. does 1 equal 1meter
Thank you for uploading this video! Much appreciated!
Thanks.. Is it possible to connect this to an app so I can put heating on when I leave work?
how do I get rid of the timers so that I can only control the heating via the thermostat? the heating came on last night at 3am randomly and I had to manually to turn the boiler off. When I switched it back on, it had 4 zeros flashing
I changed my batteries but the thermostat is not working properly. The flame indicator on the thermostat does not appear anymore. What should I do to get the flame indicator back?
Hm, what could be the cause of sudden drop in pressure ? I have new ferolli since august, and this evening pressure dropped to 0.4 bar and provided f37 error.
Hi, what if Fh code appears? Thank you for your help
after the reset, the error a61 disappeared but the bluhelix does not heat the water. I am asking for help. There are no good ferroli service technicians in Poland.
@@ukaszskrzynecki269 First of all check the condense trap is clean by watching one of my other videos. Plus blow down the condense pipe to the drain ,it may be blocked. Then try the master reset video and follow instructions. If it didn't work after that then it a circuit board issue . Normally I find the first two options work Hope this helps .
The siphon is clean, full factiry reset does not help. bluehelix is still under warranty or does the motherboard fault cover it? I'm an electronics engineer, maybe I can repair it, but where should I look?@@theferroliman2067
@@theferroliman2067The siphon is clean, the drain pipe is clear, full factory reset does not work (I press and hold the last step, it exits the menu and does not reset). Bluhelix is still under warranty. Is that covered by the disc fault? I know a little about electronics, maybe I can repair the motherboard, but where should I look? ;)
If you made sure the condense is clear and the drain is too . And definitely done the master reset . Turn off power at switch for a few minutes as well .Turn back on and let it go through the set up {fh} sequence. Press the reset once ( a short press and let go . ) If it refuses to be reset then the mother board (PCB)will need replacing.
@@theferroliman2067 Thank you very much for your time
I know this video was 10 years ago but I'm needing help, I've been in this property for almost 4 years and not once put the heating on, if I use the boiler more the once a day at different times it leaks (yearly boiler checks all been fine) it's getting very cold in here now but I don't know how to use the heating, can you help please?
@@Shaunacollins19876 first try the video of how to use a ferroli clock which matches your clock. U need someone to maybe look at your boiler and see if everything works .I'm surprised you never asked the company who comes to check it to make sure everything works ok first
Thanks for the reply! I have asked multiple times to check and make sure everything works and they always say yes everything is great! Even with the leak that happens, I will give it a try! Thank you again :)
What area do you live?
@@theferroliman2067cardiff
Hello, I have a question. I'm getting error A61. What could be the cause? Bluehelix pro rrt 24c boiler
The mode winter is on but the flame 🔥 doesn’t appear . Please help 🙏
@@majdak785 first check your external clock or room stat
Just wondering why my ferroli blue helix makes a pinging noise when in heating mode ?
@@williamgoldsbrough1972 have u got the touch screen model ?
@@williamgoldsbrough1972 ruclips.net/video/jSYGUkc79MQ/видео.htmlsi=pz1h-kLAMOe__9-Z
ruclips.net/video/jSYGUkc79MQ/видео.htmlsi=pz1h-kLAMOe__9-Z
@@williamgoldsbrough1972 ruclips.net/video/jSYGUkc79MQ/видео.htmlsi=pz1h-kLAMOe__9-Z
Go to the link provided and follow video . But change parameter 66 to 3 .see if that works
Ah god was this usefull ❤❤
is this a reliable unit?
@@slash0t5 yes it is ... As long as you fit them correctly and put a filter on and add a few bottles of inhibitor .The boilers are good . Ive had one fitted in my house too .
I've got a bluehelix hitcher 34c.. when heating is on it sounds like a pinging noise. Any answers?
Can anyone help me to put the boiler back on constant so I can use it off my thermostat again? After a power cut I had an f37 had an engineer out and it’s on timed 😫
@@Lisa2681. It's best to call us on 07807776411
Thank you, for this video 😊
Not working for me. Now error F99🙄
The same for me, how did you resolve that?
Hi i only ever turn the valve on the right am i making a mistake?
That's a great video, but I still can't understand it. I need to get my son around to sort it😊
My boiler keeps coming on at unset times even after configuration
I have a Ferroli bluehelix alpha 24c and I want to turn on the heating without any thermostat. Can it be possible? If so, how?
@@antu8995 look at some of my other videos how to use a ferroli blue helix hi-tech...u should be able to put the heating on .or watch a video where it shows how to do test mode
thanks dave, have a nice day
Legend!!! This helped me fix my boiler! My screen was flipping between the temperature and d1 code suddenly and it just would not heat up the water. It was stuck like that for a day until I tried this as a last resort since tech service told me to wait up to 3 days for a technician to arrive.
Absolute hero this was so clear and I finally have my heating working, cheers!
Thank You. First time Ive see the low battery indicator,so really helpful.
Pile of total shit these , good products are easy to use
They told me I need to clean it but still need to let some clean water in it. I didn’t understand from the video if it must be empty or not 😢
What if 01 error code appear frequntly? I must Push reset button time to time to disappear 01
@@samosamo_9817 either the condense pipe is blocking quickly or the gas valve maybe sticking. You should have a 7-10 warranty if it's the model in the video.so I'd call ferroli to call out
Thanks bro
Any idea as to why the heating keeps coming on randomly even if the left switch on the timer is set to off and none of us are turning the switch on?
@@MikeJeremy-i7e maybe the sensors need changing. And double check the clock 💯 off and it doesn't have a light bulb on the display
Thanks, pretty useful, and explained simply for the layperson who I am:)
I had an issue with my boiler that they understandably couldn’t attend because I lived too far. However, called Dave and the advice and level of care shown when explaining to me what the issue could be, and other things besides, left me knowing there are tradesmen out there that should be cherished. He is a credit to the industry and thoroughly answered ever question I had. The only disappointment I had is that I lived too far for anyone to attend but he still gave me thorough detailed advice. If you live locally don’t hesitate to use Birmingham Boiler Repairs.
@@nizzmiah756 thanks for your comment . It's really appreciated. Hopefully you got your boiler sorted in the end . If you find the time I'd be grateful if you could copy and paste it to my Birmingham boiler repairs reviews so more people could see it when choosing someone Thanks Dave
Has it got a timer for the heating ??
@@bobbrown1995 No it has wiring connections inside for an external clock . The majority of boilers now don't have built in clocks but external ones that you can choose yourself
Big love man!
How often is that supposed to be done? Mine drips
Just bought a property with this boiler, the pressure gauge is not working is it possible to get a replacement or are parts discontinued cause of age of this particular model
All the parts are still available for this boiler . If you look after it correctly, it can last for years
3 Gas engineers refused to service it cause of its age and incase they damaged parts. Yes it must be a very good boiler to last so long without any problems. Are you based in Birmingham UK?
@@AS-zi9vq yes they're a very good boiler ... We're based in Birmingham 07807776411
Excellent info
Perfect, thanks for this! Literally 24 hours in a new house and trying to figure this out. Don’t like the boiler anyway so will be replacing it with a different one but I know how this works until then!
Hi, do you need to switch off mains power? Mine says so underneath by the screws?
Shouldn't have to turn off power for this type as it has batteries.
Thanks mate for the wonderful video❤
I did as in the video, but after programming the time limits the steer continues to turn on and continues to use gas, what can I do?
Hi, is this boiler totally automatic air venting? When mine fires up (every time) I hear what sounds like a lot of air swirling around in the pump, or is there a manual vent initially needed?
You'll need to check to see if the auto air vent on top of the pump is actually open on the dust cap .
Any info on a e3 warning on a pegaso eco 11 ? Just installed and won’t fire, igniter clicking lcd on the front showing water temp after a few seconds it’s shuts off with e3 warning any info would be great
Did you manage to fix your boiler I have the same problem any help would be much appreciated👌👍
@@5andwhy gas pressure was 2 high, My gas regulator was manual so it was hard to read and it was set at 1 bar, exchanged it with a set pressure regulator and was ok, if it was a manual regulator turn the knob all the way off and just turn it in slight increments and keep trying, that e3 warning is obviously just picking up a high pressure in the gas line
Thanks sooooo much
Hi there I have one which is leaking and now I know what to do to prevent . It’s easy to get heat exchanger ? Also got a 51 code and it’s says it’s pcb permanent fault
Yes you can get the heatexchangers they're very easy to do believe it or not ,once you drain off all the water from the valves . F51 maybe the water possibly going on the electrode.
I have a problem.My ferroli bluehix work always,just when go to :::d1:::: stops for a few secound and start agein.
D1 is normally delay after the hot water tap has been used which is normal. If it's happening whilst u are using the tap then it could be debris in the flow meter and will need cleaning first
Hi do you know what causes A41 and how to fix it. I have it servived and they go in the boiler and all time I have problems when they done the service. I brought the flow sensor which seems to be a magnetic switch. however looked in the boiler the connection looks good. its a optimax he31c is parameters same for that boiler?
F41 is poor circulation..first check the sensor on the left hand side of heatexchanger it's black and white it could be loose and not sitting on the pipe correctly.
@@theferroliman2067 do you have a part code and can i get to this by just removing the white cover? I checked the bottom sensor on the flow switch and a blue wire came out of that i have taped it back in to the connector but it still trips so im thinking its this sensor your talking about. Oh by the way its A41 not F41
Hi The Ferroli Man , Nice Video loved Can you help please ! To reduce the presure boiler is 2.3 up normaly is 1.5, let me know ASP Thank you.
U need to vent / blend a radiator and let the water spray into a jug until the water pressure goes down to about 1.0 bar ...best if 2 people do it so the other can call when it's at the correct pressure
Thank you !! for you respont quick very nice of you, I am in trafic I will at home soon I let you know the results thank you!!@@theferroliman2067
Another question way 1.00 is not 1.5? I little confuse@@theferroliman2067
@@RuthGormley it'll work perfectly fine at 1 bar
I'm a little concerned how much water I should take out the radiator because every time I take the water out it stop at 1.8 and when I stop bleeding the water it start going up again past 2 what should I do I'm worried that I'm taking too much water out so give me the precise measurement or should I empty out the radiator thanks @@theferroliman2067
Hi Dave, I have a 27c HE Heating working but hot water not coming on. I've topped up to 1.5 and tried reset but still no joy.
Best to ring me .,that's a bit vague to give an answer. 08003202345 9-5
Hi Dave, Thanks for your reply,it was the flow meter which needed replaced.I had a gas engineer in to do the job.