Steven Proud
Steven Proud
  • Видео 124
  • Просмотров 371 270
VPPM-LK + CPX-AP-I-4IOL + IO-Link + CPX-AP-I-EP + CLogix + EthIP
Check out the link to the sample code below!!
This video describes how to establish a connection from a Festo VPPM Proportional Pressure Regulator Valve to a Festo CPX-AP-I-4IOL IO-Link Master which is connected via an AP-I network to a Festo CPX-AP-I-EP EtherNet/IP Master which is connected EtherNet/IP to an Allen Bradley PLC (Programmable Logic Controller).
The control method of the Festo VPPM is via IO-Link.
The sample code is programmed with RSLogix5000/Logix Designer software version v32.011.
(0:01) Overview of Video content
(1:20) Software overview from Festo website
(8:18) Festo Automation Suite (FAS) and L5X Project Export for CPX-AP-I System Process Data
(17:20) Webserver and L5X Projec...
Просмотров: 114

Видео

CPV10-GE-PT-8 + CTEU-DN + IO-Link + CLogix + DNet
Просмотров 100Месяц назад
This video describes how to commission a DeviceNet system using a CTEU-DN DeviceNet connected to a Festo Top Hat Type CPV10-GE-PT-8 (IO-Link). The Allen Bradley PLC (Programmable Logic Controller) is an older 1756-L61 and the DeviceNet scanner is a 1756-DNB. There is some sample files which compliment this video and can be retrieved at the following Google drive link: drive.google.com/file/d/1u...
CMMT x1 + ControlLogix + Ethernet/IP + Telegram 111 + PTP v2.5
Просмотров 3272 месяца назад
Telegram 111 (Point to Point Position Control) This video describes how to establish a connection from a Festo CMMT EtherNet/IP motor controller to an Allen Bradley PLC (Programmable Logic Controller) via EtherNet/IP. It then describes how to use the CMMT_EIP_MotionLib_V2.7.zip Library with the AOI (Add-On Instruction) "PTP_Drives_Festo_EIP.L5X" version v2.5 to control the CMMT series motor con...
CMMT (Firmware v34.0.11.16) + ModbusTCP Idle Timeout
Просмотров 19010 месяцев назад
This video shows how to modify the ModbusTCP timeout value of a CMMT-AS-MP controller which has Firmware v34.0.11.16. RUclips Content Supplements I have stored the zip file “ModbusTCPIdleTimeout 20200529.zip” at the following Google Drive link: drive.google.com/file/d/168aWZTWfXNA0e9fRXoEHXQ-USK7CmhW_/view?usp=drive_link
Highlight Mouse Pointer with Windows10 PowerToys Mouse Utility
Просмотров 87611 месяцев назад
This video describes how install Mouse Highlighting Features with a Windows10 operating system. Microsoft PowerToys is a set of utilities used for enhancing the windows experience. PowerToys has the built in features for the Mouse. Installing PowerToys learn.microsoft.com/en-us/windows/powertoys/install
CMMT_EIP_MotionLib v2.5 Library Overview
Просмотров 13211 месяцев назад
This video discusses the CMMT-xx-EP Single Protocol and CMMT-xx-MP Multi-Protocol Stepper/Servo Motion Controllers and the Rockwell AOI (Add-On Instruction) library, which is utilized for controlling these motion controllers from an Allen Bradley PLC (CompactLogix/ControlLogix Programmable Logic Controller). This video provides an overview the library zip file content. (0:00) Festo website PTP_...
CMMT-ST-C8-1C-MP Firmware Update v32.0.10.10 to v33.0.10.12 & v34.0.11.16 using FAS v2.7.0.752
Просмотров 347Год назад
Welcome to this video presentation where we will be discussing the CMMT-ST-C8-1C-MP-S0 Multi-Protocol Stepper Controller. The main objective of this video is to guide you through the process of performing a firmware update using FAS (Festo Automation Suite). Throughout this video, we will explore the features and functionalities of the CMMT-ST-C8-1C-MP-S0 Multi-Protocol Stepper Controller, and ...
CMMT-xx-EP x1 + CLogix + EthIP + Tel_111 + PTP v2.5 + Tel_111 + Continuous Setpoint Transfer
Просмотров 155Год назад
Welcome to this video presentation where we will be discussing the CMMT-xx-MP Multi-Protocol Multi-Protocol Servo Controller. The main objective of this video is to guide you through the process of performing a typical Point to Point (PtP) absolute movement and then explains how a Continuous Setpoint Transfer (ConfigEPos.8) is configured and movement executed. Rockwell Studio 5000 Logix Designe...
CMMT-ST-C8-1C-MP Firmware Update v32.0.10.10 to v33.0.10.12 using Device Web Page
Просмотров 211Год назад
Welcome to this video presentation where we will be discussing the CMMT-ST-C8-1C-MP-S0 Multi-Protocol Stepper Controller. The main objective of this video is to guide you through the process of performing a firmware update using the Device Web Page. Throughout this video, we will explore the features and functionalities of the CMMT-ST-C8-1C-MP-S0 Multi-Protocol Stepper Controller, and demonstra...
VTUG + VAEM24 + VAEM24 + CAPC + I-Port + CTEU-EP + CLogix + EthIP + EDS + DualPort16 + Diag
Просмотров 567Год назад
The hardware used in this video are 2 x Festo VTUG/VAEM-L1-S-24-PT valve terminals connected to Festo 1 x CAPC-F1-E-M12 splitter with a Festo CTEU-EP EtherNet/IP is used as the communication method to the Allen Bradley ControlLogix or CompactLogix PLC. This video describes how to configure the CTEU-EP module within RSLogix 5000/LogixDesign (Allen Bradley ControlLogix or CompactLogix PLC) The pu...
CPX-E-EP x1 + CLogix + EthIP + 16DI.8DO.4AI.4AO + GEN + I/O Diagnostic Interface
Просмотров 350Год назад
This video describes how to connect from a Festo CPX-E-EP terminal to an Allen Bradley ControlLogix or CompactLogix PLC. Additionally, diagnostic methods are described with emphasis on using the I/O Diagnostic Interface. The purpose is an attempt to help you accelerate the programming and commissioning of your application using Festo CPX-E-EP. The control method is EtherNet/IP Fieldbus. The Roc...
CPX-E-EP x1 + CLogix + EthIP + 16DI.8DO.4AI.4AO + GEN + Status Bits & Explicit Messaging
Просмотров 782Год назад
This video describes how to connect from a Festo CPX-E-EP terminal to an Allen Bradley ControlLogix or CompactLogix PLC. Additionally, diagnostic methods are described with emphasis on using Status bits and Explicit Messaging. The purpose is an attempt to help you accelerate the programming and commissioning of your application using Festo CPX-E-EP. The control method is EtherNet/IP Fieldbus. T...
EMCS_SMS + AP-I-4IOL + IO-Link + CPX-AP-I-PN + CPU1200 v17 + ProfiNet + Backup & Restore
Просмотров 1,4 тыс.Год назад
This video describes how to configure and use the Backup/Restore feature with Festo CPX-AP-I-4IOL IO-Link master and a SMS (Simplified Motion Series) device Connected to CPX-AP-I-PN and Siemens S7-1200 CPU. There are some files (within a “zip” file) to accompany this video that can be retrieved at the following Google drive link: drive.google.com/file/d/1QdzTPtIdUmSpJ0eAd6PEPImcOaCyZtbB/view?us...
EMCS_SMS Firmware Update with CDSU IO-Link Device Tool v1.2.6 of EMCS-YY-ST-42 Spare Part Motor
Просмотров 232Год назад
This video describes how to update the firmware of a SMS (Simplified Motion Series) device using Festo CDSU Tool software. (0:01) Overview (0:29) Festo website Firmware file download (0:55) CDSU Tool software - Connect to EMCS-YY-ST-42 Un-Parameterized Spare Part Motor (1:35) CDSU Tool software - Firmware Update Tab - Drag Firmware file to software for use (2:00) CDSU Tool software - Firmware U...
CPX-FB36 + Diagnosis via Status Bits or IO Diagnostic Interface
Просмотров 3,3 тыс.2 года назад
Check out the link to the sample code below!! This video describes how to establish a connection from a Festo CPX Valve (with CPX-FB36) Terminal to an Allen Bradley 1769-L30ERM Allen Bradley PLC (Programmable Logic Controller). The control method of the Festo CPX-FB36 is via EtherNet/IP. The sample code is programmed with RSLogix5000/Logix Designer software version V20.01. I have included a var...
CMMT-xx-EP x2 + CLogix + EthIP + Tel_111 + PTP v2.4 + MasterSlave + SyncPosAbsolute Part #2
Просмотров 9242 года назад
CMMT-xx-EP x2 CLogix EthIP Tel_111 PTP v2.4 MasterSlave SyncPosAbsolute Part #2
CMMT-xx-EP x2 + CLogix + EthIP + Tel_111 + PTP v2.4 + MasterSlave + SyncPosAbsolute Part#1
Просмотров 1,4 тыс.2 года назад
CMMT-xx-EP x2 CLogix EthIP Tel_111 PTP v2.4 MasterSlave SyncPosAbsolute Part#1
CDSU Tool v1.2.6 + CDSU-1 Firmware Update + Version v2.1.1.12 to v2.1.1.14
Просмотров 2572 года назад
CDSU Tool v1.2.6 CDSU-1 Firmware Update Version v2.1.1.12 to v2.1.1.14
CPX-AP-I-EP Combined Topologies Option#2
Просмотров 2492 года назад
CPX-AP-I-EP Combined Topologies Option#2
CPX-AP-I-EP Combined Topologies Option#1
Просмотров 4612 года назад
CPX-AP-I-EP Combined Topologies Option#1
CDSU Tool ELGS-BS (Data Restore Active) Replacement with Parameterized EMCS-YY-ST-42
Просмотров 5112 года назад
CDSU Tool ELGS-BS (Data Restore Active) Replacement with Parameterized EMCS-YY-ST-42
FST Software Upload Download Functionality
Просмотров 1,9 тыс.2 года назад
FST Software Upload Download Functionality
CPX AP I 4IOL + Festo IO Link Tool V5 1 1 6308 + Software Overview
Просмотров 2,6 тыс.2 года назад
CPX AP I 4IOL Festo IO Link Tool V5 1 1 6308 Software Overview
EMCS_ELGS-BS + 1734-4IOL + IO-Link + 1734-AENTR + CLogix + EthIP + RW Parameters
Просмотров 1,9 тыс.2 года назад
EMCS_ELGS-BS 1734-4IOL IO-Link 1734-AENTR CLogix EthIP RW Parameters
VPPM + 1732E-8IOL + IO-Link + CLogix + EthIP + ReadWrite Parameter
Просмотров 2,1 тыс.2 года назад
VPPM 1732E-8IOL IO-Link CLogix EthIP ReadWrite Parameter
CMMT-AS-xx Device Replacement using CDSB-A1
Просмотров 6653 года назад
CMMT-AS-xx Device Replacement using CDSB-A1
CMMT-xx Modulo, Record Mode=xxx, Target=060, Modulo Mode=Set Modulo Position & Reset Modulo Position
Просмотров 3583 года назад
CMMT-xx Modulo, Record Mode=xxx, Target=060, Modulo Mode=Set Modulo Position & Reset Modulo Position
CMMT-xx Modulo, Direct Mode=Absolute, Target=xxx, Modulo Mode=Shortest Path
Просмотров 4093 года назад
CMMT-xx Modulo, Direct Mode=Absolute, Target=xxx, Modulo Mode=Shortest Path
CMMT-xx Modulo, Record Mode=Relative, Target=460, Modulo Mode=Only Positive & Only Positive + Turns
Просмотров 1503 года назад
CMMT-xx Modulo, Record Mode=Relative, Target=460, Modulo Mode=Only Positive & Only Positive Turns
CMMT-xx Modulo, Direct Mode=Absolute, Target=460, Modulo Mode=Only Positive & Only Positive + Turns
Просмотров 5893 года назад
CMMT-xx Modulo, Direct Mode=Absolute, Target=460, Modulo Mode=Only Positive & Only Positive Turns

Комментарии

  • @CLAP2829
    @CLAP2829 8 дней назад

    And this is what you call a " Quick connect " !! ??

    • @Proud2BProud
      @Proud2BProud 8 дней назад

      Perhaps you were looking for a video about simple setup of FB36 with Rockwell? A 6 minute video video more suitable for this can be found at this link-> ruclips.net/video/BzgT0G6AJb4/видео.html. The "QuickConnect" (Prioritized start-up) technology feature refers to a method of establishing a connection between devices and the Master in a rapid and efficient manner (example: robot end of arm tooling). This is a ODVA EtherNet/IP specification where a device shall have this feature disabled as the factory default. Due to the requirements and effort of the ODVA spec to configure a device for "QuickConnect" I created this video and the sample code to compliment it. Once you have viewed and understand the concept and requirements to configure the FB36 for QuickConnect in video, the sample code can be used to accelerate the user efforts. I think it would take approximately 5 minutes to configure a device for QuickConnect with the sample code provided. If a user had good understanding of the configration requirements from ODVA spec, they could use software like Molex instead of Rockwell and likely setup a device in even less time.

  • @vivekrockstar7460
    @vivekrockstar7460 11 месяцев назад

    Dear Sir, For this Controller, how to change Operating mode, can you help me.

    • @Proud2BProud
      @Proud2BProud 8 дней назад

      Sorry for soo late a reply. The operational mode is changed via the digital inputs. You can find this in the user manual or contact local technical support staff at Festo.

  • @kylelatzke2072
    @kylelatzke2072 Год назад

    How similar is this to BNI004F to setup?

    • @Proud2BProud
      @Proud2BProud Год назад

      No idea - I did this video long ago and I have never used a BNI004F

  • @paco2042
    @paco2042 Год назад

    I can’t seem to get my set up to work. Once I add it to my plc, I keep getting an IO FAULTED message with an error 16#0203 because the communication times out and idk why. 😭

    • @Proud2BProud
      @Proud2BProud Год назад

      Unusual because this is normnally very straight forward. Hard to troubleshoot on YoutTube and I dont provide support here. Rockwell has bug with EDS AOP on old RS5000 versions, so, I can suggest goto webpage & confirm IO size, delete existing EDS AOP, Add again, select fixed size with hard set IO - do NOT chnage this config after accepted and closed (this is the Rockwell bug). If that doesn't work, try generic module and same method use correct instances -> I think from my memory 101,100,102 with exact IO size. If nothing works, contact Festo technical local support

  • @jmsnystrom
    @jmsnystrom Год назад

    Do you havee domething to fo with mean brewing?

    • @Proud2BProud
      @Proud2BProud Год назад

      I don't understand what you are talking about?

  • @leytonallen479
    @leytonallen479 Год назад

    could you explain the messaging more? I am using the same IO Link master module, but I am using the SM6601 ifm flow meter. I have tried doing a message to see actual flow rate but have been unsuccessful.

    • @Proud2BProud
      @Proud2BProud Год назад

      This video is about the Festo VPPM - not IFM. Messaging of IO-link master will be different for every device especially vendor specific parameters. I suggest you Read the owner manual of the IFM and also the 8IOL to find answers.

  • @mehdiiraei2219
    @mehdiiraei2219 Год назад

    Hello Steve Thanks for the youtube courses I have a big problem with downloading the project, i have 2 axis in program, X and Y in my hardware, but when I try to download the program the error message X AXIS DOES NOT EXIST. Comes up and I can download the project What should I do in this situation?

    • @Proud2BProud
      @Proud2BProud Год назад

      Hmm. SPC200 was phased out I think in 2015, so, I would look at why you are still using this - you could get yourself into a situation where you cannot even find any old parts lying around. To you problem - I am not technical support for the product, but, considering it is NOT supported any more, I suppose this is why you try me in the 1st place. The error is not mentioned in the user manuals, but if it says the axis doesn't exist and you have physical hardware, then you have a problem with the hardware and it thinks it really doesn't exist. A good way to determine hardware configuration of ACTUAL controller is to start with empty project, then Select the menu item “Upload” then “Project”. Select a Project path and give it a title name if desired, then save the project to you hard drive. When the upload is complete, the project will be open and you can see what the controller sees as its configuration. This is all I can do for you.

    • @Proud2BProud
      @Proud2BProud Год назад

      Another point from my side - If the SPC200 hardware for 2 axes exists, BUT, the connected axis cylinder (e.g. DGPIL) has an issue or is NOT connected, then I would also expect the same error you have encountered. Good luck

  • @ЕвгенийИвкин-з8н

    Hi, please tell me how to connect to Festo cmmp-as-c10-11a-p3-m3 via a computer (what program is needed, and connect to it) and download the project from it if I don't have it?

    • @Proud2BProud
      @Proud2BProud 8 дней назад

      Sorry I missed this comment soo long ago. For your questions, there is a video FCT Backup or Archivate Projects at this link -> ruclips.net/video/scQ7zG5OwuU/видео.html

  • @joseptriguerosaragay
    @joseptriguerosaragay Год назад

    Amazing tutorial! Thank you very much for your work. Greetings from Spain.

  • @keenancoverly5564
    @keenancoverly5564 Год назад

    Does the 1500 need a additional licence or package to run modbus with these function block?

    • @Proud2BProud
      @Proud2BProud Год назад

      Sorry for long response time - I was on vacation for last 6 weeks. to use the FestoMotionFHPP library Modbus FBs, there is no license required with S7-1500

  • @iamgarrettlyons
    @iamgarrettlyons Год назад

    Dang another video that has helped me - 6 years later! Thanks!

    • @Proud2BProud
      @Proud2BProud Год назад

      😂👍 hope your a subscriber 👍😂

    • @iamgarrettlyons
      @iamgarrettlyons Год назад

      @@Proud2BProud heck I am now! Lol 😂

  • @jakebecker7944
    @jakebecker7944 Год назад

    Hi Steven, I am doing a project with 100 EMCA motors. The way we have it set up is to upload every single parameter from every single motor and save it in the plc. When a motor is replaced the ip address is set and all the parameters are downloaded from the plc. Is there a way to store only the values that are changed from factory in the PLC? I am running out of capacity in my controller trying to store all this data.

    • @Proud2BProud
      @Proud2BProud Год назад

      Thats i nice size project! I can imagine running out of memory quick. This is an older project so little hard to remember if possible right now, but, there should be a AOI called single param or similar. With this you can read or write single parameters. I think there is also an AOI in the library called multi param or similarly. Here u can set up an array of all parameters you need to a limit. This forum not best for this request though- hope i give u some ideas. You should contact your local support and mention what I offer and if you don’t get anywhere, Ask them to escalate.

    • @Proud2BProud
      @Proud2BProud Год назад

      When you download the library there will be user manual which explains all the AOIs in it. There should even be examples if i recall

    • @Proud2BProud
      @Proud2BProud Год назад

      Did that help?

    • @Proud2BProud
      @Proud2BProud Год назад

      The AOIs I referred to previously are called: FPC_MULTI.L5X and FPC_PNU.L5X

    • @Proud2BProud
      @Proud2BProud Год назад

      I added navigation to the RUclips video for you - when you SHOW MORE, you can click on the link for (32:08) and navigate direct to the section that details the AOI

  • @iamgarrettlyons
    @iamgarrettlyons Год назад

    Found this in 2023. Still applies. Thanks! Very informative. Now to just figure out the STO part.

    • @Proud2BProud
      @Proud2BProud Год назад

      The Festo website has a good source for STO with EMCA in the downloads area. STO is basically the same for EMCA as it is for CMMT-ST. In the expert area, a download of www.festo.com/net/en-ca_ca/SupportPortal/Downloads/598918/653211/100244-TS-Application-Note-EN-Ver1.pdf and also www.festo.com/net/en-ca_ca/SupportPortal/Downloads/598917/653209/100242-TS-Application-Note-EN-Ver1.pdf can be downloaded. In the Documents area, brief instructions for Safety can also be found

    • @Proud2BProud
      @Proud2BProud Год назад

      I always prefer SS1-t - this is much better safety coverage

    • @iamgarrettlyons
      @iamgarrettlyons Год назад

      @@Proud2BProud yo awesome man. Appreciate the help! This is my first time in 8 years ever having to deal with this festo motor. So it’s all new! Thank you so much!! Crazy you replied after how old this video is!!

  • @williamc8313
    @williamc8313 Год назад

    Can other model use this AOI? My model is BPI009A

    • @Proud2BProud
      @Proud2BProud Год назад

      I don't know - perhaps check the balluff website where the AOI originated.

  • @MultifunktionsRaik
    @MultifunktionsRaik 2 года назад

    Thank you for the Video It was more helpfull than the manuals from Festo.

  • @Kozak450
    @Kozak450 2 года назад

    Do i have to download the configuration from CPX Configurator too the festo module also or only in TIA and download too the PLC?

    • @Proud2BProud
      @Proud2BProud 2 года назад

      Download of the hardware configuration is only necessary

  • @mariosgr9585
    @mariosgr9585 2 года назад

    Hi Steven. I am using a S7 1200 PLC to control a FESTO stepper motor. Do you know if it is achievable to control the end velocity parameter of the FCT through the PLC ? I am asking because end velocity it's not available on FHPP block.

    • @Proud2BProud
      @Proud2BProud 2 года назад

      I do not support technical questions for my personal video’s - I hardly have time to make them. Please contact your local technical support with questions about your applications.

  • @jackieduan9669
    @jackieduan9669 2 года назад

    Thanks for your video , That is really helps me a lot , I came across an error -402- , target position is behind the sofeware negetive limit , I try to connect the device , But it is failed , Is there any way to solve this problem

    • @Proud2BProud
      @Proud2BProud 2 года назад

      If you encounter a problem I suggest you read the user manual or contact technical support. Sorry, however, these are my personal videos and I am not support for everyone who watches them.

  • @haagesummane5210
    @haagesummane5210 2 года назад

    if DIN4&5 are enabled, its getting error output stage short circuited

    • @Proud2BProud
      @Proud2BProud 2 года назад

      I suggest you call technical support

  • @tk0512
    @tk0512 2 года назад

    Hello steven i have to control the cmmo st with a Siemens s1200 plc but it doesn’t work I cant reference or drive the motor Do you have a little slc text for me I’m new in plc programming it would be very great if you can help

    • @Proud2BProud
      @Proud2BProud 2 года назад

      I suggest you contact Festo Tech support at your location and they will surely help you. You might find some modbus function blocks on their website that works with 1200 as well.

  • @marcuss5330
    @marcuss5330 2 года назад

    Could you do an example using Modbus TCP?

    • @Proud2BProud
      @Proud2BProud 2 года назад

      Sorry but don’t have that. I suggest you contact Festo technical support and ask them

  • @dipakpateel1
    @dipakpateel1 2 года назад

    Hi Steven, Thanks for the informative VDO & sample code for CPX. Do you have RA HMI template for the CPX-36? Thanks in Advance.

    • @Proud2BProud
      @Proud2BProud 2 года назад

      No hmi related material to offer

  • @jameswayne431
    @jameswayne431 2 года назад

    Pretty late for that comment but thank you for just jumping to the code without explaining anything about the mapping of the variables you used in FBs. That was really helpful

    • @Proud2BProud
      @Proud2BProud 2 года назад

      Sorry for that - Yes very late reply and in my earlier days of RUclips. I hope my newer content is more helpful.

  • @PIDOtomasyon
    @PIDOtomasyon 2 года назад

    Hi, Can you share X1(25 pin socket) wiring diagram please. Urgent. I can't find correct connection.

    • @Proud2BProud
      @Proud2BProud 2 года назад

      My computer is down at moment

    • @Proud2BProud
      @Proud2BProud 2 года назад

      I’ll try again

    • @Proud2BProud
      @Proud2BProud 2 года назад

      Normally I don’t respond to comments because far to busy all the time

    • @Proud2BProud
      @Proud2BProud 2 года назад

      I have never attached any file to anything on RUclips and at moment cannot see how

    • @Proud2BProud
      @Proud2BProud 2 года назад

      sorry

  • @fabiosousa5002
    @fabiosousa5002 2 года назад

    Hello Steven, How are you? What is safety Tool in fct? My fct is returning the error 84-0

    • @Proud2BProud
      @Proud2BProud 2 года назад

      Safety tool is for setup of the Safety module installed. This comment area is not for support for you. Please contact Festo technical support for Troublshooting.

  • @TheOussamascout
    @TheOussamascout 2 года назад

    Wath about the communication With CMMO-ST -C 5 -1- LKP + CPU1200+ Modbus TCP is it the same way ?

    • @Proud2BProud
      @Proud2BProud 2 года назад

      This RUclips video for CMMP + CPU1500 should be very close for CMMO-ST-LKP + CPU1200 - give it a try !

  • @PersecutedPursuer
    @PersecutedPursuer 5 лет назад

    Thanks, Steven! I love Festo and their Automation Systems! You helped me out with your Videos!

  • @alrazysonet4550
    @alrazysonet4550 5 лет назад

    Hello Steven, I don't know how can I express my gratitude. Recently in my new job, I was given Festo Controller(CMM-ST) & Electric Actuator (EPCO) with Turck PLC! I had zero knowledge of FESTO products. But your video helped a lot to configure it and make it running. Really grateful to you. God bless you. :)

    • @Proud2BProud
      @Proud2BProud 5 лет назад

      Alrazy Sonet Thanks but my name is Steven

    • @alrazysonet4550
      @alrazysonet4550 5 лет назад

      @@Proud2BProud My bad, I guess autocorrect in my phone probably did that. Sorry about that. Now corrected.

  • @Davidkim0830
    @Davidkim0830 5 лет назад

    Your best!

  • @imsasti
    @imsasti 5 лет назад

    Hello Steven, you showed emca in linear network, how about a ring network. What'r the settings for ring network?

    • @Proud2BProud
      @Proud2BProud 5 лет назад

      Sasti Kumar Hello, I have not shown a ring network because to configure any DLR network is just a checkbox on supervisor and very simple. So, in general, you physically connect entire ring and leave 1 cable disconnected. Next, in supervisor on network tab, check “enable supervisor”. Next, physically connect cable that you left off. Next, in supervisor, click button to clear ring faults. Ya dah!You now have a working DLR network. Enjoy!

    • @imsasti
      @imsasti 5 лет назад

      @@Proud2BProud that's easy. Thanks.

  • @azizchadli8528
    @azizchadli8528 5 лет назад

    Thank you very much please if possible

    • @azizchadli8528
      @azizchadli8528 5 лет назад

      Could you make a videos about spu card of omron

    • @Proud2BProud
      @Proud2BProud 5 лет назад

      Sorry but not interested in that concept

  • @ambitiousautomation5503
    @ambitiousautomation5503 5 лет назад

    Hello sir ..will you please share the link of this powerpoint file.

    • @Proud2BProud
      @Proud2BProud 5 лет назад

      Muhammad Numan Anything I shared is already at the link in the text below the video

  • @marianv78
    @marianv78 5 лет назад

    Great

  • @jonathanvazquez8454
    @jonathanvazquez8454 5 лет назад

    Hi Steven I need to contact to you because The controller show me the error E512 and didn't know the safe controller and I want to know If I configure the controller for the first time I didn't have problems with my PLC in my case I have a PLC Siemens S7-300 I hope you can help me.

    • @Proud2BProud
      @Proud2BProud 5 лет назад

      Hello Jonathan, my videos are made in my private time and are for the public and are meant to help people without my intervention. I expect people to handle encountered issues by themselves. I do NOT have the time or capacity to provide support to any of my videos through RUclips or through a direct way via email or phone. If you have an issue with a Festo product, then please contact their technical support and please do the same for the PLC manufacturer if you have an issue with their product.

  • @tanerakcay7322
    @tanerakcay7322 5 лет назад

    thank you for the video!

  • @MrKoki36
    @MrKoki36 5 лет назад

    tendran un canal donde ver mas sobre este tipo de programacion para ver como manejar estos block de FAS a travez de una HMI CDPX para interactuar con el operador. y ver donde se guardan los tag para programar.

    • @Proud2BProud
      @Proud2BProud 5 лет назад

      Your Google translation to English: They will have a channel to see more about this type of programming to see how to handle these FAS blocks through a CDPX HMI to interact with the operator. and see where the tags are stored to program..... My Response: perhaps the translation is not accurate and you are asking a question? Are you asking if I will do another video to show the CDPX interaction with the Festo_PtP_Base Library Function blocks? If this is your question - I am not planning this and am far too busy traveling for work and pleasure at the moment. Regardless, the CDPX is separate software from CoDeSys and the visu libraries included with this Festo_PtP_Base Library are specifically created for CoDeSys. If you want the same look and feel for Designer Studio/CDPX you would have to create them yourself.

    • @MrKoki36
      @MrKoki36 5 лет назад

      @@Proud2BProud thanks for your answer

  • @keenancoverly5564
    @keenancoverly5564 5 лет назад

    Thanks a lot!

  • @aaronpaulfelonia8167
    @aaronpaulfelonia8167 5 лет назад

    Hi Steven! Is it possible to directly connect CTEU-EC to an EthernetIP Port? Will it communicate? Thank you in advance for your help! :D

    • @Proud2BProud
      @Proud2BProud 5 лет назад

      Aaron Felonia If you are talking about the CTEU-EC EtherCAT module?

    • @Proud2BProud
      @Proud2BProud 5 лет назад

      Aaron Felonia if you want to Connect to an Ethernet/Ip master then you need to buy the CTEU-EP module

    • @Proud2BProud
      @Proud2BProud 5 лет назад

      Aaron Felonia for further questions please contact technical support. My account is private and not intended to answer questions

    • @aaronpaulfelonia8167
      @aaronpaulfelonia8167 5 лет назад

      @@Proud2BProud yeah that's what I thought too. But client a bit know-it-all, yah know Anyway, thank you very much for your reply! 😁

    • @Proud2BProud
      @Proud2BProud 5 лет назад

      Make certain the client wasn't talking about EoE which is a Mailbox protocol which tunnels standard Ethernet communication over EtherCAT. In the most cases you use EoE to have access to the webserver of a device. To update a FW you use FoE (File of EtherCAT) CTEU-EC has a webserver

  •  5 лет назад

    Hello, I wonder if it is possible to connect a PLC S7 1212 (tia portal v13) and Festo FB36 via modbus with block 16DInputs and 8DOutputs

    • @Proud2BProud
      @Proud2BProud 5 лет назад

      Hello, I don’t normally answer questions on my RUclips because it is all my personal time, BUT, to me it would make more sense to use a ProfiNet node FB37 as this is the native Siemens protocol. Why are u thinking about modbus which is easily inferior. Did you buy fb36 by accident? If you had to use the Fb36, it is capable of ModbusTCP and I know the TiA portal offers some mod us FBs, I just haven’t done this myself because it’s not something that would be very common and therefore not worth my time investment.

    • @morrocantocador
      @morrocantocador 5 лет назад

      @@Proud2BProud why u put then video's on youtube if you are not ready to share your knowlegde??

    • @Proud2BProud
      @Proud2BProud 5 лет назад

      @@morrocantocador The video is sharing my knowledge on the topic I have explained within it. The FB36 is capable of ModbusTCP, so if your V13 TIA is, then it would be possible, but, I would recommend using a CPX-FB33 ProfiNet as the head module instead of the FB36 and this way you have real-time communication.

  • @alphabot4685
    @alphabot4685 5 лет назад

    Hello Mr proud I know you normally don't answer questions so I will try to ask a yes or no question. The 4 io-link master ports on the cecc-lk are not enough for my application so my question is wether I can connect an io-link hub (for example from balluf ) to the cecc-lk to control more than 4 io- link devices. Thank you have a nice day.

    • @Proud2BProud
      @Proud2BProud 5 лет назад

      The CECC-LK has a CANopen Master. So, I would say it should be very possible to add a CANopen-IO-Link Master from another mfg to do what you are asking

    • @alphabot4685
      @alphabot4685 5 лет назад

      Thank you for the quick answer! that would be possible of course.

    • @Proud2BProud
      @Proud2BProud 5 лет назад

      Your Welcome

  • @morrocantocador
    @morrocantocador 6 лет назад

    Are you thinking about putting something about webserver for Festo Plcs? Thing kind of hmi but on pc like siemens have. Thanks

    • @Proud2BProud
      @Proud2BProud 6 лет назад

      Abderahim Ennejjai I am not in habit of answering requests nor do i usually answer questions on my channel. Everything I do on my channel is on my personal time after work and I hardly have the time for that.

  • @morrocantocador
    @morrocantocador 6 лет назад

    Is there a way to simulate this when we don't have the controller and motor? i tried to simulate it but the 24v power bit remain low

    • @Proud2BProud
      @Proud2BProud 6 лет назад

      There is no way to simulate any hardware connected to CANopen that I know of. If you find something let me know

  • @sathishkumar2625
    @sathishkumar2625 6 лет назад

    Sir I have one problem I can't connect HMI with plc but separately I have connect and copy the program.pls upload one video how to connect plc with hmi

    • @Proud2BProud
      @Proud2BProud 6 лет назад

      I don't understand your comment. The video content I post shows how to do specific things. I do all of these on my own personal time after work. This video comment description Is for what it indicates. I do not take requests on making other videos nor do I provide support via RUclips.

  • @saqnt
    @saqnt 6 лет назад

    Steve Proud does it again! Thanks for the super helpful info!

  • @ElectricalisEasy
    @ElectricalisEasy 6 лет назад

    You were a life saver...this tutorial really helped me and saved me a lot of time ..

  • @saqnt
    @saqnt 6 лет назад

    As Steve mentioned in 16:13, since he swapped controllers for whatever reason, his old license resided in the old controller, so now that he bought a new one controller he can get the license from a Festo representative but an easier way would be to purchase the controller with the license pre-installed. Controller with basic license CECC-X-M1-YS-L1 8082793 www.festo.com/net/en-us_us/SupportPortal/default.aspx?q=8082793 Controller with advanced license CECC-X-M1-YS-L2 8082794 www.festo.com/net/en-us_us/SupportPortal/default.aspx?q=8082794

  • @leopoldo4374
    @leopoldo4374 6 лет назад

    I am looking for help

    • @Proud2BProud
      @Proud2BProud 6 лет назад

      Keep looking - watch the video - download the sample code - you can do it - I have faith in you.

  • @jeromembeche8907
    @jeromembeche8907 6 лет назад

    thanks for the video but can you explain how to get the correct address

    • @Proud2BProud
      @Proud2BProud 6 лет назад

      Hello Jerome, I don't normally converse on my channel because I hardly have the time to create the videos and so don't expect to support them. In your case, I do NOT understand your question. The address for the raw process data is %IW1, which is found when you double click the sensor on channel 0 of the IO-Link master. Further, you click the IO-Link I/O mapping tab and expand the PDV(InA). If you look in the GVL, you will also find I mapped the %IW1 to a tag.

  • @dirkiecool
    @dirkiecool 6 лет назад

    How do you get those tables in the comments so well set up? Those record/direct -operation tables look so great. Did you made those yourself?

    • @Proud2BProud
      @Proud2BProud 6 лет назад

      Nothing magic - i just typed them in.

    • @Proud2BProud
      @Proud2BProud 6 лет назад

      Starting from left to right and using tabs where needed

  • @amineelkahlaoui1548
    @amineelkahlaoui1548 6 лет назад

    i have a probleme in panel mobile 277 iwlan "error adresse profisafe " i need a help

    • @Proud2BProud
      @Proud2BProud 6 лет назад

      I don't know what a panel mobile 277 iwlan is nor do i support people on RUclips - I wish you good luck