- Видео 6
- Просмотров 182 906
Robert O
Добавлен 23 апр 2016
Harbor freight 3500 inverter generator battery replacement
Battery replacement on the harbor freight 3500 inverter generator this is the part numbers from eBay have everything I used including the hydraulic table
Battery
www.ebay.com/itm/381336044954
500 pound hydraulic table
www.ebay.com/itm/Ironton-Hydraulic-Table-Cart-500-Lb-Capacity-/392319498769?_trksid=p2349624.m46890.l49292
Thanks for watching
Battery
www.ebay.com/itm/381336044954
500 pound hydraulic table
www.ebay.com/itm/Ironton-Hydraulic-Table-Cart-500-Lb-Capacity-/392319498769?_trksid=p2349624.m46890.l49292
Thanks for watching
Просмотров: 30 193
Видео
Westinghouse IGen 4500 to Natural Gas
Просмотров 6 тыс.4 года назад
Westinghouse IGEN 4500 to natural gas only
Harbor Freight 3500 Gas shut off valve
Просмотров 17 тыс.4 года назад
How to access Harbor Freight Predator 3500 inverter generator gas shut off valve. Parts used 2 pin connector www.ebay.com/itm/181436431097 Toggle switch need to drill just a bit to fit www.ebay.com/itm/303417369265
Westinghouse IGen 4500 DF Dual Fuel Natural Gas conversation
Просмотров 34 тыс.4 года назад
Westinghouse IGen 4500 DF Tri fuel natural gas conversion
Harbor freight Hydroponic greenhouse
Просмотров 2,4 тыс.4 года назад
Harbor freight 6 x 8 hydroponic greenhouse
Harbor freight 3500 inverter generator Natural gas conversion please check description of parts used
Просмотров 93 тыс.5 лет назад
Harbor freight inverter generator Natural gas conversion kit and gas valve modification the Kit I used In this video is from motorsnorkel.com/product/motorsnorkel/msk3102-motor-snorkel-tri-fuel-natural-gas-propane-and-gasoline-conversion-kit/ you can call them 1-800-553-5608 it’s kit # MSK3102 it’s made for Honda but fits perfectly $187.00 The Parker kit fittings are the same as a pressure wash...
Roberto Ourique Live Stream
8 лет назад
Thanks for a to the point video. I just did this today. Used a rubber coated waterproof toggle switch. I mounted his horizontally just below the Run/Start switch. Works perfectly. Thanks again!
Thanks so much. Doing this as soon as the connector and switch arrives. Thanks for the links to order 👍🏻
My predator 3500 has a valve at the bottom of the carburetor bowl. You open it with a flat blade screwdriver. When you open it the fuel drains out of the carburetor bowl through a clear plastic hose that empties out through the bottom of the chassis. Elegant really. So when I’m getting ready to store my predator 3500, I just leave the switch in the off position which shuts off the gas, and I drain the carburetor bowl by turning the screw at the bottom of the carburetor bowl. A couple of turns, and the gas runs out of the carburetor bowl. I don’t know about the predator, but Johnson outboard used to warn you not to run the engine until the gas is all gone because it causes detonation, which is hard on the engine.
You doing so much fuck’n RAMBLING you didn’t show HOW the bolt and screws are inserted. 👎🏾👎🏾
Will this kit work on Westinghouse igen5000 dfc inverter ?
Great idea! Thanks and this mod is going in tomorrow.
The hose between the demand regulator and the generator should be kept as short as possible as the demand regulator works off of vacuum pulses from the carburetor. The long grey hose should be between your gas meter and the demand regulator.
any idea why when i turn the propane on at the tank, its leaking from inside the unit somewhere? no leaks anywhere leading up to unit including inlet port. but definitely leaking from within
Thank u man i haven’t been able to find this battery anywhere
My generator would die off after starting using this set up. I contacted Nash Fuel, and was told that the regulator needs to be within 3 feet from the gas inlet on the generator. That is, using the same setup, one may need to connect the hose to the natural gas line first, and then run the regulator into the generator. Also, Nash Fuel has removed the adjuster on the regulator because generators need to use the max setting. One regulator can only pull one generator. Hope this helps.
Would you mind put the links to the quick connect and adapters you use to connect the gas line to the generator? Appreciated and tks very much!
Some items on the part list seem incorrect. The generator has a 3/8 flare for propane. To turn that into a 3/8 quick connect, shouldn't you require a 3/8 MALE (instead of female) to 1/4 male adapter fitting?
@@whatsaroundus Hi, we removed the factory fitting, just turn it slowly and it will come out, and then you will be left with a 1/4 pipe female fitting on the generator. You can also do it with the 3/8 male but it will stick out more and can easily be hit. Hope this helps
Ours had a battery., just no clips and screws…was not connected.
Thank you sir for this video. I watched it 3 years ago and got everything hooked up to my gas stub out last year. Used it for Beryl and it all worked like a charm!
And here I am, after Beryl.
My power is still out, and I need to connect my dual fuel westinghouse 12500 to natural gas. I am very confused with the regulator stuff. Do I have to disconnect the one for propane ? To be able to connect to the natural gas one? Is there any link/model number for a natural gas regulator? Do we find them in a Lowe's or Home Depot around the Houston area?
@@redb2153 Hi, if the stock propane regulator is adjustable, some are but not many, then you can open the adjustment screw a few turns, and that should be fine, if it is not adjustable, you have to buy that special low pressure regulator do not put a barbecue regulator on it. That would be dangerous because the gas will continue to flow gas even if the generator is off, I believe you can get a Nash regulator on Amazon eBay or directly from Nash
Thank you, I am a mostly blind disabled Vet. and got just ehat I needed from your vid er o, bay. We I'll be her r by tues. I am by Houston Tx. and power drops out here a lot.😢
Great video
any problem witj it being a gel battery
Does anybody have another link to the toggle switch? Doesn’t seem to be working.
Hey, thanks for the vid. I am about to do exactly what you did. Where did you get those parker fittings?
Good simple explanation,thanks. I'm looking for the online fuse size?
That switch hack is awesome! Good video
Thank you!
Has anyone ever been able to determine the approximate BTU's/Hr or CF/Hr usage on natural gas under various electrical loads (idle, half-load, full load)? I have a A250 natural gas meter (est. maximum 250,000 BTUs) that currently serves a 110,000 BTU natural gas Boiler (for heat and domestic hot water), a natural gas stove/oven (9,500-74,5000 BTUs but when in use, generally usage is closer to 27,500 BTUs while cooking) , and a natural gas clothes dryer (20,000 BTUs, if it's needed for laundry). At general utilization, it looks like I'll have about (at most) about 92,500 BTUs available to supply the generator. If anyone has information of the estimated NG usage by the iGen4500 under various loads using NG, it'd be appreciated.
~ 10,000 BTU per horsepower. You should be OK with 92,500 BTU. My gas company installed a larger gas meter free of charge.
This mod doesnt work on mine. If you run the carb empty and then let it sit for a few hours and check the carb for gas there is a decent amount of fuel that comes out. The fuel shut off leaks even when closed
Awesome video, thank you
How is that battery holding up? Does it turn over faster with the gel than it did with the standard battery?
nobody would ever know except for that video :)
We have used the ruclips.net/user/postUgkxOTeIs0vv4_9B5hsmnLsk9r930uDQLu_Y for probably 30 hours with our camper and it’s been great! The noise level is really only noticeable when running the AC and other appliances like the microwave, hair dryer, or coffee pot. It’s not huge like other ones and it has wheels so even at 90lbs, I can move it!
It works as reviewer recommended
Great Information!! Thank You so much for making this video and sharing, It Is greatly appreciated!!
Very informative video and thanks for explaining it very well. I would like to know if this same set up will work on a champion dual 4500 inverter too.
Thanks for the video. I have a 1-1/4 gas line from the meter. I got a 1 1/4 to 3/4 inch reducer and have 1 3/4 inch ng hose. Do I need to reduce it to 3/8 and then get the 3/8 to 1/4 adapter for the generator or can I just get a 3/4 to 1/4 adapter? Thanks again
Can you do this setup if you already have a gas valve / tap set up in your garage or does it have to be write off the M another word is there a high and low pressure you're tapping off of or is where you're tapping off the same pressure as it is in a house where the furnace connect to when I was building my house I installed to natural gas Taps that are currently capped off in the garage one to run a natural gas barbecue grill and a natural gas generator
If it’s at least 3/4 pipe it should be fine, a short run +or - 5 feet of 1/2 also should work, if there’s not enough gas supply the generator will not produce the full capacity it won’t harm the generator Hope this helps, I have more videos with it running off a 3/4 line in the back yard
So I see that you went the GEL battery vs standard Lead Acid it comes with. Amy concerns with the lack of ventilation in the battery compartment?
What type of regulator? Spec wise
Nice hair dryers...
Thank you so much. Great info and thanks for the links as well. I appreciate you taking time to teach me something. God Bless.
Thank you so much for showing!
Thanks for this informative video. The one thing that would be helpful is links below for the neccessary parts needed. othervise very helpful.
So how do the wires connect to the toggle switch (polarity) ? Does each wire from the male pin you purchase connect to one of the two connectors on the toggle switch ?
Does not matter with polarity as the switch only interrupts the power.
Does this battery come with the clips and screws?
Great question mine did not…
Great job thanks for sharing!
That's an excellent generator, we have one. Ran for 30 hours during Dec 23-24 when we had power out from high winds and it was 14 degrees in NC. Ran about half load and kept the whole house going except the 240v items. Propane fireplace to stay warm.
Ok I have to be honest with myself, doing this myself would be above my pay grade. Who exactly would I hire to do a conversation?
Will this fuel shut off work on a predator 9500 generator
I'm probably 2 years late and really appreciate the video. I have a 9500DF and plan on doing the same thing
I have a 7000 running watt Champion Inverter Generator I want to convert to NG. Do you know what size gas line I need? Do I have to tap into the NG pipe right off my gas meter?
It’s 3/4 off the main gas line and you should use minimum 1/2 if it’s under 10 feet long Anything longer 3/4” from the regulator to the generator Get a BBQ NG hose it’s cheaper and better it also comes with the quick connector. Amazon or eBay
nice to fid this, wires n switch ordered. Curious to see your connection to natural gas, I ordered a US Carb kit and wondered how you ran hise/fitting.
I have a leaky shut off valve, so looking for a video to get into that. Carb bowel keeps slowly refilling with the valve in the off position.
Can that table lift a car?
SMH.....haven't seen a car out there that weighs less than 500 pounds??...