Active Controls LLC
Active Controls LLC
  • Видео 30
  • Просмотров 30 867
Discover the Ultimate Soft Start for RVs and Tailgaters!
Introducing the ActiveStart 30 AMP Softstarter, perfect for RVs and extreme tailgaters! Learn how this device protects your air conditioning system with voltage and surge protection. Don't miss out on this essential RV gadget! #RVLife #Tailgating #SoftStart #RVProtection
Now this product here is for um Rvs, Boondockers, Tailgators, Extreme Tailgators there's more videos to come showcasing that but to tell you about this product it's a soft start it's an inline soft start this has a 30 amp uh rating hundred 15 volts so it's only for 115 volts air conditioning systems we do have a follow up product coming out in December for 50 amps and that will handle two 30 volts but this product is speci...
Просмотров: 29

Видео

Plug & Play Softstart Marine 30 amp ActiveStart
Просмотров 862 месяца назад
Featuring Our New Design of our Softstart 30 amp Marine Plug and Play. The ACS30M is a plug and play softstart that will enable you to start an air conditioner on a small generator. This can be used for your boat and RV as well! It has 30 Amp Rating at 115 VAC; Reduces inrush current by 50% and allows a Smooth Start for AC. It's also Light weight and easy to carry essentially very Portable and ...
Plug & Play SoftStart Marine 50 Amp ActiveStart
Просмотров 923 месяца назад
ActiveStart 50 amp contains 2 softstart Circuits that work independently 2 start your multiple AC units. If one side shuts down the other leg will continue to operate. More features and higher current rating to run your full RV on a 50 amp service with 5250 joules of surge protection included! Now with 5 Yr Limited Warranty! Included in Box: ACS50M, Marine 50 amp dogbone, and a ground neutral p...
Introducing Our New 30 amp Softstart!
Просмотров 5624 месяца назад
This upgraded product works out of the box for power pedestal and any sized generator. New product is designed for higher ambient temps and replaceable surge protection. Now with 3150 Joules! Plug it in and Go! For other applications use our provided app to select other configurations for optimal performance. Its 115 VAC and 30 amp rating allows for your AC to run along with other appliances. P...
Demonstration of the ActiveStart Softstart ACS50W Installed to a RV Transfer Switch
Просмотров 3658 месяцев назад
The ActiveStart product is rated for 104-240VAC and works out of the box for shore power pedestal and ANY sized generators. Wire it in and Go! For other applications use our provided app to select other configurations for optimal performance. Its 50 amp rating allows for your AC to run along with other appliances with 5200 joules of surge protection included. An industry first 50 amp dual leg s...
Softstart 50Amp Running a 5 Ton AC unit
Просмотров 2,9 тыс.9 месяцев назад
Check out our Activestart 50Amp run a 5 ton industrial AC unit and 2 small ACs on a Dual Fuel XP13000HX with Propane. The ActiveStart product is rated for 104-240VAC and works out of the box for shore power pedestal and ANY sized generators. Plug it in and Go! For other applications use our provided app to select other configurations for optimal performance. Its 50 amp rating allows for your AC...
ACS20Px & ACS30P App Update Version 1.8
Просмотров 207Год назад
Check out our powerful app that helps optimize the performance of our products. Use Promo Code "RUclips" and get 5% Off purchases!
ADV EMS & Softstart Updated App Walkthrough
Просмотров 127Год назад
The best app in the industry for our advanced softstarter! Use Promo Code "RUclips" and get 12% Off purchases!
Pump Starter Model Available Now!
Просмотров 85Год назад
The Pump Starter is an inline softstarter that will reduce the inrush current during the start of your pump. The app gives you access to change the ramp up time and starting power percentage to allow for the most reduction of power. The unit is designed to ramp the output voltage upon power being applied to the unit. The ideal application requires power to be interrupted by a contactor or a man...
Introducing Our New Product! The ActiveStart Power Tools Model
Просмотров 156Год назад
The ACS20PT and ACS2PT-S (20 amps) is intended for starting a single high load such as a large table saw or large vacuum cleaner. This will allow other minor loads to run on the unit but only 1 large motor will be started until unit resets for next load. You can use it to run multiple power tools but only use one tool at a time for in rush current reduction. These devices will monitor system he...
ActiveStart Inverter Model Coming Soon!!
Просмотров 520Год назад
The ACS20PIM (20amps) is intended for starting a single high load such as an air conditioner or freezer. This will allow other minor loads to run on the unit but only 1 large motor will be started until unit resets for next load. These devices will monitor system health including current, voltage, frequency, with programmable startup power. - Starting current reduction and programable startup p...
ActiveStart ACS50PS 50 amp running off of 6000 W Generator on House
Просмотров 755Год назад
The ActiveStart product is rated for 104-240VAC and works out of the box for shore power pedestal and ANY sized generators. Plug it in and Go! For other applications use our provided app to select other configurations for optimal performance. Its 50 amp rating allows for your AC to run along with other appliances with 5200 joules of surge protection included. An industry first plug and play 50 ...
50 Amp Intro and App Walkthrough
Просмотров 960Год назад
The ActiveStart product is rated for 104-240VAC and works out of the box for shore power pedestal and ANY sized generators. Plug it in and Go! For other applications use our provided app to select other configurations for optimal performance. Its 50 amp rating allows for your AC to run along with other appliances with 5200 joules of surge protection included. An industry first plug and play 50 ...
50 Amp ActiveStart Metal Enclosure Intro
Просмотров 433Год назад
The ActiveStart product is rated for 104-240VAC and works out of the box for shore power pedestal and ANY sized generators. Wire it in and Go! For other applications use our provided app to select other configurations for optimal performance. Its 50 amp rating allows for your AC to run along with other appliances with 5200 joules of surge protection included. An industry first 50 amp dual leg s...
ActiveStart 4 Wire Advanced SoftStarter working on a 5 Ton AC Unit
Просмотров 1,6 тыс.Год назад
This video is showing how our product reduced the inrush current of more than 80% to start the compressor in this 5 ton ac unit. This item in this video is available on the Active Controls website: active-controlsllc.com/ The ActiveStart product gets wired directly to the compressor of an air conditioning system. It is dual voltage rated working for either 115 Vac or 230 Vac systems and comes w...
First Look at the ActiveStart 50 Amp SoftStart
Просмотров 2,6 тыс.Год назад
First Look at the ActiveStart 50 Amp SoftStart
ActiveStart SoftStart running with a Generator on a House
Просмотров 827Год назад
ActiveStart SoftStart running with a Generator on a House
Why you need a wired ActiveStart SoftStart
Просмотров 316Год назад
Why you need a wired ActiveStart SoftStart
ActiveStart Advanced Softstarter Demo Part 2 with App
Просмотров 455Год назад
ActiveStart Advanced Softstarter Demo Part 2 with App
Which one do you need? The ActiveStart Plug and Play or Wired Version
Просмотров 2,1 тыс.Год назад
Which one do you need? The ActiveStart Plug and Play or Wired Version
ActiveStart 20 amp running a Camper 15000 BTU AC on a Champion 2500 Watt Generator
Просмотров 3,4 тыс.Год назад
ActiveStart 20 amp running a Camper 15000 BTU AC on a Champion 2500 Watt Generator
Field Video at Altitude Water with the Wired ActiveStart 40 AMP
Просмотров 1,5 тыс.2 года назад
Field Video at Altitude Water with the Wired ActiveStart 40 AMP
Walk-through of ActiveStart Home Installation AC
Просмотров 3,3 тыс.2 года назад
Walk-through of ActiveStart Home Installation AC
ActiveStart vs SoftStart with a Portable Residential AC
Просмотров 2,2 тыс.2 года назад
ActiveStart vs SoftStart with a Portable Residential AC
ACS30P working on the Bluetti AC200MAX Power Station
Просмотров 5742 года назад
ACS30P working on the Bluetti AC200MAX Power Station
ACS30P Working on Generators
Просмотров 6662 года назад
ACS30P Working on Generators
ActiveStart App Walkthrough Video
Просмотров 8092 года назад
ActiveStart App Walkthrough Video
Introducing the ActiveStart 30 AMP Softstarter
Просмотров 2,6 тыс.2 года назад
Introducing the ActiveStart 30 AMP Softstarter
Active Controls LLC Introduction
Просмотров 2342 года назад
Active Controls LLC Introduction

Комментарии

  • @JaredCarter84
    @JaredCarter84 4 месяца назад

    I may have missed it but what size is this AC unit? 4/5 ton? Thank you

    • @activecontrolsllc
      @activecontrolsllc 4 месяца назад

      In the video is a 3 ton AC unit but the 40 amp version is ideal for Residential Home systems, Marine air Conditioners or Commercial units drawing less than 40 amps this is typically 6 tons or less.

  • @danielkpictures
    @danielkpictures 4 месяца назад

    this is great. As a 30amp owner, can I trade my old version in now to update to the new version in this video?

    • @activecontrolsllc
      @activecontrolsllc 4 месяца назад

      Please email customerservice@active-controlsllc.com, and we can discuss the options.

  • @liljoey1686
    @liljoey1686 4 месяца назад

    Is it on the website yet?

    • @activecontrolsllc
      @activecontrolsllc 4 месяца назад

      Yes this product is available now on our website. Here is the direct link active-controls-llc.myshopify.com/products/activestart-softstart-30-amp-acs30ps

  • @mmcdermott215
    @mmcdermott215 5 месяцев назад

    Does the 30 amp plug and play have the same performance as the hardwired unit? I believe you said the hard wired was at 80 percent

    • @activecontrolsllc
      @activecontrolsllc 5 месяцев назад

      Our plug and play has a starting current reduction rate of about 50%

  • @Xyrium
    @Xyrium 6 месяцев назад

    Is this UL listed, and can it be used to reduce the massive and disturbing jolt when these portable ACs experience when the compressor first kicks in? Thanks!

  • @survivingstageivcancer130
    @survivingstageivcancer130 6 месяцев назад

    I heard you fine. what I didn't hear was whether I should get 2 soft starts and wire them into my two different (carrier) and (Coleman) rooftop units with my 30 amp shore power to run both or whether I should get the plug an play to run them both

  • @persoot
    @persoot 7 месяцев назад

    $460.00 for this product. thats why people are taking apart there ac units

  • @Hutch_Davenport
    @Hutch_Davenport 8 месяцев назад

    I bought a ACS30P for an 11,500 BTU Cool Cat AC/Heat pump. I have a 2200w surge inverter generator (1800w run rated) and it looks like the numbers work out fine for running it, but will I have issues with the plain 30amp model on a 2200w surge 1800w run inverter generator? Thanks!

  • @picobyte
    @picobyte 9 месяцев назад

    Nice! I run a victron inverter and 16kWh battery as backup. Less noice but when it runs out that diesel/petrol generator is saving the day.

  • @dj5752
    @dj5752 10 месяцев назад

    It's December 2023. Can it now be purchased? I have a 3 ton unit. Thanks

    • @thomasvictorin3015
      @thomasvictorin3015 10 месяцев назад

      Hi JD, Yes. We have been selling the product on our website. Let us know if you have any questions.

  • @robbiedarby2312
    @robbiedarby2312 Год назад

    Can you have a wired active start and the plug in active start in use at the same time

    • @thomasvictorin3015
      @thomasvictorin3015 Год назад

      Yes you can and will not interfere with each other. We will be showing that in our next video. It is also already commonly used as part of RV setups as well when they have both units.

  • @mikedunston3479
    @mikedunston3479 Год назад

    Almost 1000 dollars no thank you I installed 2 soft starts for less than 500 dollars on both of my acs on my camper

  • @Jjaymay29
    @Jjaymay29 Год назад

    When will this be available? I just bought the regular one on Amazon. I’m running a 4000 watt inverter to run an air compressor on a work van.

    • @activecontrolsllc
      @activecontrolsllc Год назад

      It is available now! Here is the link active-controls-llc.myshopify.com/products/activestart-softstart-inverter-model-acs20pim-s

  • @cheekybastard99
    @cheekybastard99 Год назад

    Nice

  • @joegifford1668
    @joegifford1668 Год назад

    I saw a link for your page on an Rv site on Facebook. A happy customer had shared it. First let me compliment you on this very well done field video. Your presentation gives great information about the ac and connecting as well as equally important safety precautions. This unit installed. At the end your unit is running on the soft start. Is your fan a multi speed one? Or is the video playing tricks and its not going slow. Im investigating a unit for my camper and have seversl other " tech like " questions thanks Joe

    • @activecontrolsllc
      @activecontrolsllc Год назад

      @joegifford1668 Hi Joe...its one of those tricks video and spinning objects! I have a single speed compressor and single speed fan. You can post questions here or contact us directly. I'll be happy to answer them.

    • @joegifford1668
      @joegifford1668 Год назад

      ​@activecontrolsllc ok I have 2 Wen inverter 4k peak 3500 rated generators. Each have a 30 amp plug I can plug in my TT and have and it works my camper. I also have the parallel kit to connect both and end up with a 50 amp plug. I intend to install a 50 amp plug on my house going to either a panel interlock or a 50 amp interlock switch panel. Now. I am wondering if I should get a 50 amp plug starter. And I have seen the app and can this be used with one of my gens with the 30 amp plug and an adapter for my camper as well as the whole house? Possibly a single gen on the house as needed? Both not needed most of the time

    • @activecontrolsllc
      @activecontrolsllc Год назад

      @@joegifford1668 Yes. That is correct. I have another video showing that running on my house as well. Having the wired version on the home AC combined with the 50 amp unit I can easily run my whole house on my 7500 peak generator. The best solution is with the wired unit on the AC which allows you to use a smaller generator instead of like a 13KW or 15KW.

  • @johndoe-ek6vl
    @johndoe-ek6vl Год назад

    Got my 20a model yesterday, thanks for the super fast shipping! I'll probably go ahead and get your hard wired kit for my hvac system to run on a predator 8750.

    • @activecontrolsllc
      @activecontrolsllc Год назад

      Yes. It will work very nicely on the predator. I have another customer that was able to start 4 ton on a 9kw generator on propane in eco-mode! I was actually blown away by the results!

    • @sonfitz8450
      @sonfitz8450 5 месяцев назад

      Did the AC have a wired dedicated soft start attached? Of did the active start run the AC by itself?

  • @TravisPickle
    @TravisPickle Год назад

    do you have a home assistant intergration?

    • @activecontrolsllc
      @activecontrolsllc Год назад

      Hi Travis...Not sure I understand the question but feel free to email me at techsupport@active-controlsllc.com

    • @TravisPickle
      @TravisPickle Год назад

      @@activecontrolsllc I dont onow if your bluetooth protcol is open, allowing devices to parse the data it provides to the phone app. Home Assistant is a community driven home automation service which allows its users to check on device status and even create automations based on events. Imagine if both you hot water and ac are on and you have automatic transfer switch turn on generator and your device shows it load and you create an automation based on generator is on and hot water and AC to turn off hot water heater during power outages.

    • @activecontrolsllc
      @activecontrolsllc Год назад

      @@TravisPickle Our protocol isn't open right now but have things in the works for some future integration with some automation planned maybe utilizing digital controlled breakers.

  • @mega-hb4re
    @mega-hb4re Год назад

    We need one for solar system inverters

  • @mega-hb4re
    @mega-hb4re Год назад

    When are you coming out with one for Solar inverter?

  • @indigomovement
    @indigomovement Год назад

    Will active soft start 50 amp work with a rv ac unit and a portable ac unit on shore power?

    • @DeFiDuke
      @DeFiDuke 9 месяцев назад

      i think the 30 amp would be better because you would have to convert the 50amp plug for the portable generator

  • @solarpunk5950
    @solarpunk5950 Год назад

    Hello, I have an AC200MAX and a 10k BTU mini split it's a Rolli Cool P800. It's an older style that is not inverter based so it surges. I can get my Bluetti to start the AC but it usually trips a low voltage alarm. Would this product resolve this? Would I need the 20amp or 30amp version of this product? Thanks

    • @activecontrolsllc
      @activecontrolsllc Год назад

      Is the low voltage fault from the Bluetti or the Rolli Cool? Normally after a unit starts its the running amps that the power source has to be able to handle and this case the Bluetti. Our devices only reduce the startup surge not the running amps. If it trips low voltage right away than reducing the surge will help in that scenario. I am currently testing my inverter model for this type of application.

    • @solarpunk5950
      @solarpunk5950 Год назад

      @@activecontrolsllc I'm pretty sure it's on the Bluetti end. The compressor tries to start and the 200max faults right away. The 200 resets the inverter ( the DC loads stay on so it's not a hard crash) when it comes up again the AC will try again after a few mins sometimes it works other times this cycle repeats and eventually starts. Since it seems strained I haven't used it with the 200. My fear is it will get to temp turn off and won't restart or go into this false start cycle.

    • @solarpunk5950
      @solarpunk5950 Год назад

      @@activecontrolsllc I have decided to roll the dice and give this product a try (20 amp version) I will let you know how it goes. 👍

    • @solarpunk5950
      @solarpunk5950 Год назад

      @@activecontrolsllc it worked! No more low voltage alarms for the ac200max! So happy thank you!

    • @activecontrolsllc
      @activecontrolsllc Год назад

      @@solarpunk5950 That's awesome and thankyou for letting us know.

  • @YouMeAndThem3
    @YouMeAndThem3 Год назад

    This is awesome, i would love to demo and review this.

  • @Respiratorymike
    @Respiratorymike Год назад

    Hello. I have basically the same trailer and generator. Is it updated to work now or will I have to send it in as well? Thanks

    • @activecontrolsllc
      @activecontrolsllc Год назад

      All units are updated now, no need to have to send it in.

    • @Respiratorymike
      @Respiratorymike Год назад

      @@activecontrolsllc thank you

    • @nrogers901
      @nrogers901 Год назад

      @@activecontrolsllc I have the same generator and the same AC, can't get it to work with my 30 amp adapted down to a 20 amp plug. Is there something I can do to make that work?

    • @activecontrolsllc
      @activecontrolsllc Год назад

      @@nrogers901 Hi Nathan... The things that may effect your results are altitude if you are at any elevation remember your generator output is decreased by 3.5% every 1000 ft. The other item that may change the results is the run capacitor on your unit if it has an issue. Lastly it could our starter as well. Can you tell me your exact symptoms. What faults are you getting in the app?

  • @LetstalkaboutitwiththeLees
    @LetstalkaboutitwiththeLees Год назад

    Very nice owner/founder great customer service . He is helping me tremendously. Customer Service 10/ out of 10. Thank you Sir , don’t hesitate to support this business and products . Definitely recommend

  • @charliemeadows8099
    @charliemeadows8099 Год назад

    Do you think it’s possible to create a RV AC which has mini-split efficiency and power draw? I installed a 9K btu mini-split, 22 seer, in an off-grid tiny house, and it is whisper quiet with low power draw on the batteries. Got me to thinking there is room to improve RV rooftop units.

    • @activecontrolsllc
      @activecontrolsllc Год назад

      Hi Charlie...absolutely they can. I worked at Dometic Marine to introduce variable speed technology in the marine AC space and I know the RV division was also working on it as well. Most RV OEM's do not want to pay extra right now for the technology although the consumer does. Once solar powered inverters become more popular they will quickly have to adapt!

    • @charliemeadows8099
      @charliemeadows8099 Год назад

      @@activecontrolsllc I’ve seen your videos showing the 80% peak current reduction. Does the active soft start have any measurable change to the units overall power efficiency?

  • @flash8051
    @flash8051 Год назад

    Please get a decent mic for your videos... Also, you should explain what you mean about using the wired version "for inverters" as opposed to the plug and play version for A/Cs??? No idea what that means...

    • @activecontrolsllc
      @activecontrolsllc Год назад

      I agree..I need to use my mic a bit more even in my office. I will make a follow-up video to explain the differences in technology. Thankyou.

  • @josiemuela2717
    @josiemuela2717 Год назад

    Interested watched on GAVIN'S GARAGE... Can we use the Active Start 20amp on our 5500watt/4000W champion gas inverter generator and our Keystone springdale 24ft with A/C Furrion 15.5K ...I already put the app on my cell but on setting has up to 4500W Medium Generator, assuming that's what we'd choose. Or should we get the 30amp? Oh and do both models come with the bonding plug and dog bone? thanks :)

    • @activecontrolsllc
      @activecontrolsllc Год назад

      Hello...Yes you can although I am surprised you need it with that size generator. The 30 amp comes with dogbone and 20 amp with bonding plug standard. I would select the 3000 watt setting for best results.

    • @josiemuela2717
      @josiemuela2717 Год назад

      @@activecontrolsllc thanks!

    • @josiemuela2717
      @josiemuela2717 Год назад

      I saw it can be used on home a/c too!

  • @spartysean6979
    @spartysean6979 Год назад

    I have and AC200max, and i bought the active start. I cant get it to run my roof top AC on the 16ft trailer. It runs light and everything low volt, but once i kick on ac it trips. Any suggestions

    • @activecontrolsllc
      @activecontrolsllc Год назад

      What size is your rooftop unit? I have done some testing with my Bluetti but it really depends on the size of the unit. I have also mentioned the best solution is the wired version for inverter applications.

  • @terideck1464
    @terideck1464 Год назад

    I can't hear you, I have all the volumes turned up. I imagine your info was good though

    • @activecontrolsllc
      @activecontrolsllc Год назад

      Sorry...I didn't have my mic on and thought I was speaking loud enough but evidently I was wrong. 😂

  • @advancedxdirective
    @advancedxdirective Год назад

    Can this work on a refrigerator as well?

    • @activecontrolsllc
      @activecontrolsllc Год назад

      Yes it will work with a refrigerator as well if running on a generator but not on a solar generator or small inverter setup.

  • @dukewon209
    @dukewon209 Год назад

    I have just received 20 amp one, it did not work on my 13,500 ac for my camping trailer with 2300 w generator. Do I need 30 amp one?

    • @activecontrolsllc
      @activecontrolsllc Год назад

      Hi...If you tried both the 2000 watt generator and 2000 inverter settings with no luck please give me a call so we can troubleshoot further. Are you getting any faults? Based on that size generator you do not need the 30 amp version.

  • @spyder000069
    @spyder000069 Год назад

    Can this be used on a 2 wire 240V well pump? My inverter generator takes a pretty good dip when the well kicks in.

    • @activecontrolsllc
      @activecontrolsllc Год назад

      Yes it can but I have a product coming out specifically for well pumps. This unit will be very expensive just for that application.

  • @meowmeow55789
    @meowmeow55789 Год назад

    Hello! Im interested in using one of these with the new Jackery 3000 solar generator to power up my RV but most importantly my air conditioner. My AC unit is 15,000 BTUh...will this work?

    • @activecontrolsllc
      @activecontrolsllc Год назад

      Hi..I have done some testing with the Bluetti with success but it really depends on the inverter and if it can handle that momentary surge and how many other things you have running when the AC starts. Hard to say with a 15K BTU. You are welcome to try it and if it doesn't work we can process a return. In these cases I tell customers the wired version is the best option for inverters.

    • @meowmeow55789
      @meowmeow55789 Год назад

      @@activecontrolsllc thanks for the response! Yeah seems like the solar generators aren't quite there yet to power AC efficiently but maybe a few years down the road it will be good! Either way I definitely want to get one of these when traveling and using campsites. I've had a lot of friends recommending it!

  • @royking4076
    @royking4076 Год назад

    Why is there modifications required? Is there a GFCI circuit integrated into the soft start?

    • @activecontrolsllc
      @activecontrolsllc Год назад

      The change I made for his unit had to do with the low voltage detect time and there is no GFCI circuit integrated in our unit.

    • @aericadiponzio3965
      @aericadiponzio3965 Год назад

      @@activecontrolsllc would that work for a 2000w Chmpion as well?

    • @activecontrolsllc
      @activecontrolsllc Год назад

      @@aericadiponzio3965 Hi it really depends on your AC size. The champion 2000 is a good generator but it will not start a 15K btu and a 13.5K will be close but a wired version that we also offer will make it seamless for the 2000 watt generator regardless of the AC size.

    • @activecontrolsllc
      @activecontrolsllc Год назад

      @@aericadiponzio3965 It really depends on the size of the AC. A 2000 W will not do a 13.5 or 15K BTU but it should be good with anything smaller.

    • @RG-wy1ol
      @RG-wy1ol Год назад

      Where can I get that kit ?

  • @facelaw674
    @facelaw674 Год назад

    Hey how are you doing I'm trying g to figure out how can I get one of those for my self can I use you as a Sponsor on my race bike thanks .

    • @activecontrolsllc
      @activecontrolsllc Год назад

      Hi Send us an email to discuss. Customerservice@active-controlsllc.com

  • @facelaw674
    @facelaw674 Год назад

    Hi I've been trying to buy of of those soft starts and I dont know what I'm doing wrong with your app can you help me out thank you

    • @activecontrolsllc
      @activecontrolsllc Год назад

      Hi...Yes we would be happy to help. You can email us directly at customerservice@active-controlsllc.com or call our office at 754-307-1303. Thankyou.

  • @tonybochiano
    @tonybochiano Год назад

    Why doesn't manufactures install door start?

    • @activecontrolsllc
      @activecontrolsllc Год назад

      What do you mean by "door start"?

    • @slurpeyatari
      @slurpeyatari 2 месяца назад

      I think what Tony is asking is why don't the manufacturers install soft starts themselves on the units or have the capabilities built in. I guess one could argue the variable units do.

  • @brandymoreta3435
    @brandymoreta3435 Год назад

    This is a must have during hurricane season. Love it!

  • @jimcraver6461
    @jimcraver6461 Год назад

    Nice. Can’t wait

  • @Moneymallenclosure
    @Moneymallenclosure Год назад

    Perfect products, very good quality and best service!! Activestart is the best VFDs, Carel Products, Bluetti Solar products supplier!!

  • @seanwaite4755
    @seanwaite4755 Год назад

    Awesome! Congratulations on the release 👏

  • @bobbyphillips7190
    @bobbyphillips7190 Год назад

    Talking about AC unit power is great when power goes out during a hurricane or tropical or bad weather events. How will this work during a Cold weather event like Freezing Ice and Snow storm when using the Heating side of the system?

    • @activecontrolsllc
      @activecontrolsllc Год назад

      Hi Bobby, If you have a Heat Pump the unit will work the same way to start your compressor. A heatpump just has a reversing valve for the refrigerant flow but the actual compressor will start in the same fashion any typically draws a little more in heat mode due to the pressure but we will still softstart it the same way.

  • @goinsomewheretogether
    @goinsomewheretogether Год назад

    Great info and wish you much success with your products. Already have installed a "soft start" on my A/C and an plug-in EMS. One suggestion, if I may, is you might want to consider a lavalier mic for your videos.

    • @activecontrolsllc
      @activecontrolsllc Год назад

      Yes...all new videos have me mic'd up for clarity. Thankyou.

  • @thetraveltrailerguy
    @thetraveltrailerguy Год назад

    Nice product, I could sure use one of these

  • @unclelala4216
    @unclelala4216 Год назад

    love the product but if your going to do more videos please get a better mic. Its very poor audio quality. very hard to hear with my old ears.😉

    • @activecontrolsllc
      @activecontrolsllc Год назад

      Thankyou for the feedback and I agree so I have ordered a mic for future videos. 😀

  • @unclelala4216
    @unclelala4216 Год назад

    waiting for your 50 amp version. is there a ETA on its release

    • @activecontrolsllc
      @activecontrolsllc Год назад

      Hello...The 50 amp is going through internal testing now and will be available in March for ordering. Register on our website to get our newsletter with updates.

  • @da7heaven
    @da7heaven Год назад

    Impressive!

  • @JustPlainBill0
    @JustPlainBill0 Год назад

    First, may I suggest that use a directional lapel microphone to minimize background noise or, during editing of your video , cut the background noise 90% and add your message as a voice over. (I wasn't able to hear your presentation and that's a shame because you do provide a lot of useful information in your videos.) Second, I'd like to know if your ActiveStart devices provide soft start to motors other than compressors; specifically a 3/4 HP, 240v well pump requiring 3kW starting power (LRA). I'm interested in the ACSW4W16 model for that purpose.

    • @activecontrolsllc
      @activecontrolsllc Год назад

      Hi Bill, I completely agree with you as this was one of our first videos and I wanted the viewers to know and hear the generators running and it didn't turn out quite like what I was wanting....lesson learned! I've had other customers ask me this question about the pumps and as long as your pump has a PSC motor you can use a softstart on it. That is basically a Run Capacitor installed on it. We have just launched the ACS4W40 and the 16 will follow in March.

    • @JustPlainBill0
      @JustPlainBill0 Год назад

      @@activecontrolsllc Thank you for the reply. I have some other questions I'll send through your website customer service contact.

  • @lelandeggleston1041
    @lelandeggleston1041 Год назад

    Could this be used to soft start a well pump?

    • @activecontrolsllc
      @activecontrolsllc Год назад

      Hi...it can as long as the pump has a PSC motor. Basically means it has a run capacitor mounted to it. Contact us with info and I can look closer at it.

  • @stacyhazelwood4033
    @stacyhazelwood4033 Год назад

    Ok, I have purchased your ActiveStart SoftStart ACS30P 30AMP unit for my RV to run it with my 3500w generator or my Titan Solar Generator. Looking at your channel here, I am wondering if it would work for my house if get a professional to wire a transfer switch or sub panel to connect a generator in case of a power outage? Or, do I need to get this new product you make that wires directly to my unit? My house AC unit is Goodman Model GSH130421AF Max breaker amp 30. Min. circ amps 22.1. voltage range 197-253 phase 1 hertz 60. p.s. I am really impressed with your informative website and youtube channel. I am a small business owner and I try to support other small business, especially veteran owned. Thank you for your service to this country.

    • @activecontrolsllc
      @activecontrolsllc Год назад

      Hi Stacy, Thankyou and these are great questions. I was actually going to do another video this week to help users pick what's best for the application. In this case the ACS30P is only for 115 VAC application which means it would not work well for your house. The wired version directly on the AC would be the best option for the home with current offerings and you will be able to run that unit off of your generator without any issues. I am planning the same thing for my house and that will be another video coming soon. I have the 50 amp version of the plug and play that will be available in Feb timeframe that will handle the rest of the house and could be wired with transfer switch as you have described and give complete emergency backup capability without the need for an extremely large generator.