Welcome to Irfan CFPS, your go-to source for expertise in Fire Protection Systems! 🔥🚒
I'm Irfan, and I'm here to help you gain knowledge in water-based & gaseous fire suppression systems, foam systems, fire alarm and detection systems, and more, all according to applicable NFPA codes and standards.
Whether you're looking to grow your personal career or improve your organisation's fire safety, my videos are designed to educate and inspire.
Join me on this journey to become a fire protection systems expert! 📚💪
Don't forget to subscribe and hit the notification bell 🔔 to stay updated on the latest content!
Viewers can watch my videos in Hindi on www.youtube.com/@irfancfpshindi
Visit our website: irfancfps.com
I'm Irfan, and I'm here to help you gain knowledge in water-based & gaseous fire suppression systems, foam systems, fire alarm and detection systems, and more, all according to applicable NFPA codes and standards.
Whether you're looking to grow your personal career or improve your organisation's fire safety, my videos are designed to educate and inspire.
Join me on this journey to become a fire protection systems expert! 📚💪
Don't forget to subscribe and hit the notification bell 🔔 to stay updated on the latest content!
Viewers can watch my videos in Hindi on www.youtube.com/@irfancfpshindi
Visit our website: irfancfps.com
CFPS Recertification Guide Explained in 5 minutes (2025)
🔥 CFPS RECERTIFICATION: Step-by-Step Guide! 🔥
Are you looking to renew your Certified Fire Protection Specialist (CFPS) certification? In this video, I walk you through the entire CFPS recertification process, step by step! 🎯
✅ How to access the NFPA certification platform
✅ Checking your certification details & unpaid invoices
✅ Adding work experience & relevant certifications
✅ Meeting the minimum 50-point requirement
✅ Submitting your application successfully
⚡ Stay certified and keep growing in the fire protection industry! ⚡
💡 Found this video helpful?
👍 Like | 🔔 Subscribe | 📢 Share with your colleagues!
💬 Drop your questions in the comments-I’ll respond ASAP!
#CFPS #FireProtection #NFPA #CFPSR...
Are you looking to renew your Certified Fire Protection Specialist (CFPS) certification? In this video, I walk you through the entire CFPS recertification process, step by step! 🎯
✅ How to access the NFPA certification platform
✅ Checking your certification details & unpaid invoices
✅ Adding work experience & relevant certifications
✅ Meeting the minimum 50-point requirement
✅ Submitting your application successfully
⚡ Stay certified and keep growing in the fire protection industry! ⚡
💡 Found this video helpful?
👍 Like | 🔔 Subscribe | 📢 Share with your colleagues!
💬 Drop your questions in the comments-I’ll respond ASAP!
#CFPS #FireProtection #NFPA #CFPSR...
Просмотров: 84
Видео
Water Spray System Design SECRETS You Need to Know! Basics
Просмотров 282День назад
In this video, we dive into the design concepts of Water Spray Systems as per NFPA 15, focusing on their ability to prevent disasters in high-risk environments such as factories, power plants, and substations. Here’s what we’ll cover: Key Design Considerations: Nozzle Spacing and Spray Patterns Design Density and Minimum Operating Pressure Extinguishment Methods: Surface Cooling, Smothering by ...
My 2 Year Youtube Journey | The Moment That Changed Everything
Просмотров 471Месяц назад
In this video, I share my journey, starting from the moment that changed my life. I talk about the renewed sense of purpose that I found and how it shaped the direction of my RUclips channel. I want to take this moment to thank all of you for your support and being part of this amazing community. If you have any questions, feel free to drop them in the comments, and don't forget to subscribe fo...
Class K Fire extinguisher NFPA 10
Просмотров 258Месяц назад
In this video, we shall learn the placement and sizing of Class K fire extinguishers as per NFPA 10 requirements
Class D fire extinguisher NFPA 10
Просмотров 230Месяц назад
In this video, we will learn the travel distance requirements for Class D fire extinguishers and also discuss about the important notes related to these extinguishers as per NFPA 10 requirements
Deluge Water Spray system & system components - Session 2
Просмотров 435Месяц назад
In this video, i am going to explain the various system components used in water spray system as per NFPA 15. Also, the concept of Deluge valve water spray system with pilot actuation at the end of the video.
How to Size & Place Class C Extinguisher
Просмотров 1792 месяца назад
In this video we shall learn about Class C fire extinguisher as per NFPA 10 requirements
Water Spray Fixed system Basics : NFPA 15
Просмотров 6212 месяца назад
"In this video, I cover the basics of Water Spray Systems, including: What is a Water Spray System? The Difference Between Water Spray and Sprinkler Systems Applications of Water Spray Systems Types of Nozzles Used in Water Spray Systems How to Select the Right Nozzles Key Definitions from NFPA 15 Whether you're learning about fire safety systems or looking to understand the technical differenc...
How to Size & Place Class b Extinguisher
Просмотров 2522 месяца назад
In this video, we will learn how to size and locate Class B fire extinguisher as per NFPA 10 requirements.
Part 2 Sizing and Location of Class A Extinguisher
Просмотров 3032 месяца назад
In this video, we shall consider an examplet to distribute the fire extinguishers and select the rating of class A extinguishers as per NFPA 10 requirements
How to Size and Place Class A fire extinguisher
Просмотров 4172 месяца назад
How to Size and Place Class A fire extinguisher
Fire Extinguishers NFPA 10 location requirements
Просмотров 1,2 тыс.4 месяца назад
Fire Extinguishers NFPA 10 location requirements
Types of Fire Extinguishers, Methods of Fire Extinguishment, NFPA 10
Просмотров 5024 месяца назад
Types of Fire Extinguishers, Methods of Fire Extinguishment, NFPA 10
Classification of Fires | Type A,B,C,D,E,K
Просмотров 6344 месяца назад
Classification of Fires | Type A,B,C,D,E,K
Introduction to Fire Safety: Essential Tips for Everyone
Просмотров 5225 месяцев назад
Introduction to Fire Safety: Essential Tips for Everyone
How to Calculate Fire water tank capacity (NFPA 20)
Просмотров 2,5 тыс.5 месяцев назад
How to Calculate Fire water tank capacity (NFPA 20)
How to Calculate Bund Walls For Diesel Tanks NFPA 20
Просмотров 1,2 тыс.6 месяцев назад
How to Calculate Bund Walls For Diesel Tanks NFPA 20
Diesel Tank Calculation | NFPA 20 | Fire Pump Room Design
Просмотров 1,8 тыс.6 месяцев назад
Diesel Tank Calculation | NFPA 20 | Fire Pump Room Design
Class 10 | Fire Pump Room Layout Design NFPA 20 | Part 1
Просмотров 4,6 тыс.7 месяцев назад
Class 10 | Fire Pump Room Layout Design NFPA 20 | Part 1
Career in Fire Protection | Discussion with Dr. Danish
Просмотров 1,8 тыс.7 месяцев назад
Career in Fire Protection | Discussion with Dr. Danish
Estimating Water Demand with Sprinklers
Просмотров 1,7 тыс.7 месяцев назад
Estimating Water Demand with Sprinklers
Class 6 | Elite fire Standpipe System Calculations
Просмотров 1,6 тыс.7 месяцев назад
Class 6 | Elite fire Standpipe System Calculations
Class 5 | Elite fire Hydrant Network Calculations
Просмотров 2,5 тыс.8 месяцев назад
Class 5 | Elite fire Hydrant Network Calculations
Certified Fire Protection Specialist Exam Update 2024
Просмотров 2,7 тыс.8 месяцев назад
Certified Fire Protection Specialist Exam Update 2024
Class 4 | Elite fire Fire Hose Cabinets calculations
Просмотров 2,5 тыс.8 месяцев назад
Class 4 | Elite fire Fire Hose Cabinets calculations
Class 3 | Elite fire Sprinkler system calculations
Просмотров 3,4 тыс.8 месяцев назад
Class 3 | Elite fire Sprinkler system calculations
Class 2 | Understanding Elite Fire Software
Просмотров 2,8 тыс.9 месяцев назад
Class 2 | Understanding Elite Fire Software
How to Design Sprinkler Systems (NFPA 13 Explained)
Просмотров 6 тыс.9 месяцев назад
How to Design Sprinkler Systems (NFPA 13 Explained)
Class 6 | Smoke Detector Spacing per NFPA 72
Просмотров 3,7 тыс.9 месяцев назад
Class 6 | Smoke Detector Spacing per NFPA 72
I have small concern... As you said there is no fire alarm system without panel.. but we can use smoke alam with embedded battery..like stand alone system
Yes u r right but kindly check nfpa 72 whether it is acceptable and let me know.
Hi, can you do a sample design from scratch, like how to layout and their standard distances?
Sure will do
What if the most remote area on-site is less than 1,500 sq. ft.? For example, consider a hotel layout with multiple small rooms separated by partitions, each containing a toilet, along with a corridor. In this scenario, how should the number of sprinklers be determined, and how should the most remote hydraulic calculation area be selected?
thanks mr Irfan, but I have a same question as luislorenzo ? could you explain.
Very helpfull videos Please make videos about the transformers protection water spray system
Very helpful
Really Thank a lot brother. You give all the answer that I have. Just one more question, what is the reference of this calculation from NFAP 13?
thanks for the info, when I solve for 14 sq root of 75 = 121.2 gpm per sprinkler. Am I missing something?
Really helpful ❤ btw, for hydraulic calculation for transformer protection, we should consider all the nozzles to be activated simultaneously, right? Not based on minimum 2500sqft...
Yes we need to include all open nozzles in calculation . The area should be the surface area of the equipments.
thanks bro really helpful :)
Appreciate the feedback!
❤❤❤❤
Thanks. Please do share with others
great!!!!
Thank u. Please do share with others
Excellent Description...💥 Keep continue....👍
Thanks for the feedback
Assalam walaikum bhai Do you know anyone who can do hydrolic calculation for hvws system of fire protection. I need that person
Walekumassalam. Currently no dear. If u have any doubts u can reach out to me
Why are we calculating K.equivalent?? What are we understanding with the value of K equivalvent...?? Is it that our K equvi shall be less 5.6 if we have using K 5.6 sprinkler, and if K equi exceed 5.6 means our calcs is wrong somewhere..
What about hese reel /landing valve demand??
We need to calculate separately
Why it is not having any maximum distance requirement?
Reason I explained in the video. Kindly go through once again. We follow as per nfpa guidelines
Congrats bro, keep going
Thanks
How this 1.1 will come in the formula...
Nice question. It was explained in the video - however if u consider the formula also the result will be same because we need to add 5% + 5%.. try it out and let me know
www.nfpa.org/for-professionals/certification/cfps#reference-materials
Please let me know if you website is working as the link does not take me to your website
My website has some technical error. U can watch my videos on my RUclips channel “irfancfps”
Barakallah
💐💐
Iam interested
How do we get pipe size is 32 mm here and previous step 25mm? Just assumption?
I don’t think there is any contradiction. For 25mm size we can go upto 2 sprinklers for 3rd sprinkler we need to use 32mm pipe. Please check “pipe schedule method” video available on nfpa 13 series playlist for better understanding
kindly clarify In which chapter at NFPA 20.
If u watch my full video u will understand bund wall calculation is not available in nfpa 20. However, general practice for sizing the bund wall is explained in the video
when it will start ?
All videos available on my channel irfancfps . Please go through the playlists.
Found your content recently, I have my test coming up so im very grateful for these videos pls keep them coming thank you!
Do share with others so that my videos would be helpful to them as well. Thanks for your positive feedback.
Dear Brother, Our local code has not specified how many remote hydrants I need to consider and what the minimum residual pressure should be. Now, we are planning to design a project (area about 20,000 sq m) with peripheral hydrant system as per local code requirements. Now can you please guide me how many flows and pressures I need to consider as per practical standards. Thanks in advance
Thanks for the query. Minimum residual pressure at remotest hydrant shall be 20psi. If the project is like a camp etc need to calculate the fire flow based on the bldg to bldg distance and bldg area and type of construction. Once we get to know the fire flow then we can consider the number of hydrants accordingly. However if the fire flow / demand requirement is more than 1500 gpm then it is better to consider 2 remotest hydrants. In any case better option would to be consider 2 remotest hydrants for calculations.
Hi, can you recommend a good training institute for CFPS preparations
Please send me an email. I will recommend
Is hydrant and standpipe are same ..
Both not same. For hydrants nfpa 24 to be referred and for standpipe systems like landing valves and hose systems need to refer nfpa 14
@ can you plz make a video of that hydrant vs standpipe system
No sound
we.tl/t-DNsK7mnINs
I'm interest
All videos are available for free on my RUclips channel irfan cfps. Please check the playlists
Congratulations Wish u more success ahead
Thank u so much
What should be the design criteria for multi-sensor detector
All the best
Thanks
sharing is caring....✌bro...
Thank u so much
Congratulation on the mile stone
Thanks
Thanks a lot for your explanation
Most welcome
Congratulations sir🎉🎉🎉🎉
Thanks
Mubrook for 6.3k ..soon it would be 6.3 millions soon
Thanks
Masha Allah mabrook
Thank u
Congrats on completing 2 years on RUclips. 🎉
Thank u
Super bro🎉
Thanks
bro, can you able to do the training for ELITE Software for one complete project. (How do enter the data, what need to enter? what need omit? based on different conditions?
Just check the initial videos of elite fire series available
bro. i want to know, how do use ELITE software with one complete project for better Understanding.
Just check the elite fire series available on playlist. U will understand
Can you provide me the audio file??
we.tl/t-psJk1Q3jXH
@@irfancfpscould you please provide again? That link has expired
17:38 Dry sprinklers and mechanically sealed with extended tubes from the fip to the water seat, not pressurized with air. A lot of dry heads have vent/weep holes on the fip. Loving the videos! Thank you.