Sludge Dewatering Lab Test for Belt Filter Presses

Поделиться
HTML-код
  • Опубликовано: 23 авг 2024
  • This method was developed to test polymers used for sludge dewatering using belt filter presses. This method correlates very well with in-plant evaluations and can be a helpful tool for testing different polymer in the lab and determining optimal polymer doses.
    This method was developed by Researches at The University of Texas at El Paso and funded by El Paso Water Utilities.
    The video description to prepare a polymer solution is:
    • Polymer Preparation fo...
    Music:
    capoproductions...
    / musicbymarcus

Комментарии • 12

  • @murderedout5650
    @murderedout5650 Год назад +1

    Thanks for the video! It was very helpful

  • @IreneLopez-kn6qu
    @IreneLopez-kn6qu Год назад +1

    Nice technology. Could you please tell us where to find the belt press sample, or the manufacturer. Thank you

  • @qayumpasha2608
    @qayumpasha2608 5 лет назад +1

    nice

  • @nsyaf_iqah
    @nsyaf_iqah 6 месяцев назад

    Hi. May I know if the chart can be referred regardless type of polymer (i.e anionic, cationic etc)?
    Also, could you please explain the formula 4/250? 250 is the sludge sample volume (250ml)? 4 comes from? Thanks in advance!

  • @mpalpunk4342
    @mpalpunk4342 3 года назад +1

    Hey. Nice video :). Is it possible to find somewhere online the conversion figure and conversion table for polymer dosage? Thank you in advance.

    • @ggdelgado
      @ggdelgado 3 года назад +1

      sure, send me an email to ggdelgado83 at g mail dot com. I'll send you a copy.

    • @mpalpunk4342
      @mpalpunk4342 3 года назад

      @@ggdelgado I have sent you an email. Thank you very much. :)

    • @rihabbelguembour8319
      @rihabbelguembour8319 2 года назад +1

      @@ggdelgado Hello Mr
      Can you help me concerning: the dimensions of the cylinder (height and inside diameter), diameter of the openings in the two discs and their thicknesses, the material of the cylinder and the discs, and finally the weight applied at the end of the video.
      Good luck .

    • @ggdelgado
      @ggdelgado 2 года назад +1

      @@rihabbelguembour8319 Good day, The diameter of the cylinder was based on the diameter of the belt samples we got from the manufacturer. Manufacturers provided samples of 9.0 cm and it was the same material they use to make the belts for belt presses. So we sized the cylinder to be 9.0 cm. They weight applied was three plates of 30 lbs each, total of 90 lbs to simulate the pressure inside the rollers of a belt press. I hope this helps and if you have any more questions let me know. Thank you for watching.

  • @asifawan6825
    @asifawan6825 3 года назад

    Pls mentioned polymer dosage how much ppm are used for 250 ml sludge dewatering and what was the polymer concentration

    • @ggdelgado
      @ggdelgado 3 года назад

      Here's is the video how to prepare the polymer solution: ruclips.net/video/MKF5WCaBCQs/видео.html. The polymer solution concentration is 2,000 mg/L.
      On minute 1:47, you can use the chart to estimate the concentration of polymer in pounds per dry ton of solids.

    • @asifawan6825
      @asifawan6825 3 года назад

      @@ggdelgado thanks ☺️