Etabs Analysis of G+3 Building | Design of Residential Building Part 7 | Incluidng Project Report |

Поделиться
HTML-код
  • Опубликовано: 8 окт 2024

Комментарии • 14

  • @abhishekchhunju5912
    @abhishekchhunju5912 2 года назад

    Well made video. Thank you Sir. I was searching for the code reference for torsional discomfort in the building. i.e. the first two mode should under go the translation in either direction, and third mode to the rotation. Please help me find some code reference for this explanation is NBC or IS code. and how can we solve it if we didnot get the first 3 mode as we need.

    • @civilconst
      @civilconst  2 года назад

      Glad it helped. You can find that in IS 1893:2016 part 1, cl 7.1 torsional irregularity.

  • @argenkarmacharya2724
    @argenkarmacharya2724 3 года назад

    we shall check the drift and displacement for serviceability condition...i.e with property modifier as per code????

    • @civilconst
      @civilconst  3 года назад

      Yes. I have made a video on that too. Do check it.

  • @bishalchaudhary4562
    @bishalchaudhary4562 2 года назад

    What is the solution when the top rebar area comes more than lower floors..please explain

    • @civilconst
      @civilconst  2 года назад

      That's for B/C ratio.

    • @bishalchaudhary4562
      @bishalchaudhary4562 2 года назад

      @@civilconst Is it ok to design residential buildings by making B/C ratio off in design prefences

  • @vishal0199
    @vishal0199 3 года назад

    I think it is 0.004 times height of single storey i.e 3 m in this case and not total height. Please confirm..

    • @civilconst
      @civilconst  3 года назад

      Maximum permissible storey displacement and permissible storey drift are calculated from IS: 1893 - 2002 and IS: 456 - 2000. Maximum permissible storey displacement is limited to H/500. Where, H - total height of building. Maximum permissible storey drift is limited to 0.004 h.

  • @sujanjoshi54
    @sujanjoshi54 2 года назад

    Well explained. Thanks alot. I practiced on one building but the result was not proper. Can u make video on that building. Please share ur mail so that i can send the drawing to u.

    • @civilconst
      @civilconst  2 года назад

      That's not possible brother. I can't make a whole video for a particular problem. But you can share what actually your problem is? I can help with that.

    • @sujanjoshi54
      @sujanjoshi54 2 года назад

      Load applied:
      - 4" wall - 7
      -9" wall - 13
      LL - 1.5, 2, 3
      FF- 2
      Beam rebar came only 100 TO 250

  • @chojaywangchuk3295
    @chojaywangchuk3295 4 года назад

    sir i am not getting your part 1 till part 7 video ..share me link sir

    • @civilconst
      @civilconst  4 года назад

      ruclips.net/p/PLpyKfKgCZOelcxT1bN48i2IE9qY3H4fRA