    Circuit Parameters of DC Machine Model:
    Armature Resistance Ra (ohms) = 0.78 ohms
    Armature Inductance La (Henry) = 0.016 Henry
    Field Resistance Rf (ohms) = 5 ohms
    Field Inductance La (Henry) = 100 Henry
    Field-armature mutual inductance Laf (H) = 0.01 Henry
    Initial field Current: 300
    R-Load = 1000 ohms
    (DC Series Generator):
    In a series wound generator, the field winding is connected in series with armature winding so that whole armature current flows through the field winding as well as the load. Since the field winding carries the whole of load current, it has a few turns of thick wire having low resistance. Series generators are rarely used except for special purposes e.g., as boosters.
    Armature current, Ia = Ise = IL = I Total(say)
    Terminal voltage, V = Eg - I*(Ra + Rse)
    Power developed in armature = Eg*Ia
    Power delivered to load = V*IL