How To Wire A Single-Location GFCI Outlet With An Unprotected Outlet On The Same Circuit! DIY

Поделиться
HTML-код
  • Опубликовано: 14 июн 2024
  • ITEMS I USED:
    - Voltage Tester - amzn.to/3iNvPLm
    - LEVITON 15 AMP GFCI - amzn.to/3qM2g0X
    - LEVITON 15 AMP Tamper Resistant Duplex Outlet - amzn.to/3IIAety
    - VOLTCLAW - amzn.to/3Lk9Wzi
    - VOLTCLAW Combo Pack - amzn.to/3uyr6Tc
    - Insulated Screwdriver 2-In-1 - amzn.to/3LspJMu
    - WAGO Wire Connectors (36 Pieces) - amzn.to/3LHlLQD
    - WAGO Wire Connectors (75 Pieces) - amzn.to/36WzyDA
    - Wire Strippers - amzn.to/3IUDhii
    - Needle Nose Pliers - amzn.to/3qM7V7m
    - Retractable Utility Knife - amzn.to/3qI4Dll
    ELECTRICAL BOXES I USED:
    - New Work 1 Gang - amzn.to/34M96LU
    - Old Work 1 Gang - amzn.to/3oIKB9p
    - Old Work Depth Adjustable 1 Gang - amzn.to/3HKEBoh
    NM ELECTRICAL CABLES I USED:
    - ROMEX 14/2 (50’) - amzn.to/3rHU5Ue
    - ROMEX 14/2 (100’) - amzn.to/3HJgsys
    - ROMEX 14/2 (250’) - amzn.to/3JiuGXm
    - ROMEX 14/3 (50’) - amzn.to/3sCxW9a
    - ROMEX 14/3 (100’) - amzn.to/3oHMBij
    - ROMEX 14/3 (250’) - amzn.to/3uQTMbE
    - ROMEX 12/2 (50’) - amzn.to/3oGQkwE
    - ROMEX 12/2 100’) - amzn.to/3BhSZSh
    - ROMEX 12/2 (250’) - amzn.to/35WJzA6
    - ROMEX 12/3 (50’) - amzn.to/3sC2Q1o
    - ROMEX 12/3 (100’) - amzn.to/34VOYao
    - ROMEX 12/3 (250’) - amzn.to/34AyNiL
    SHOP MY ONLINE AMAZON STORE AND CHECK OUT ALL THE TOOLS I USE!
    www.amazon.com/shop/genevo9
    On this episode I'm going to show you How To Wire A Single-Location GFCI Outlet With An Unprotected Outlet On The Same Circuit! Step by step electrical tutorial for Beginners!
    Please Subscribe To Our Channel! / fixthishouse
    FOR BUSINESS INQUIRES SEND TO:
    FIX THIS HOUSE
    P.O. BOX 2511
    BREMERTON, WA 98310
    UNITED STATES
    FOR BUSINESS INQUIRES EMAIL ME AT:
    fixthishouse1@yahoo.com
    DISCLAIMER:
    This video is meant for informational, educational, and entertainment purposes only! To better your knowledge on the concepts of electricity, electrical circuitry, entertainment component circuitry and all other wiring methods. Electrical codes in my area may be different from yours so always make sure you follow and stay current with your local code. With different codes around the world constantly changing standards, regulations and rules, it is the sole responsibility of the viewer to educate themselves on their local requirements before undertaking any sort of project. That being said Fix This House cannot claim liability with all applicable laws, rules, codes and regulation for a project. DO NOT ATTEMPT ANY WIRING OF ANY KIND if you lack the knowledge and understanding required. Otherwise, personal injury and/or death as well as property damage or loss could occur. Your safety is your own responsibility, including proper use of equipment and safety gear, and determining whether you have adequate skill and experience. If you are a younger person or are inexperienced with electrical devices, ask for help from a parent, teacher or a licensed professional.
    WARNING- Electricity is dangerous and can cause personal injury or DEATH as well as other property loss or damage if not used or constructed properly. If you have any doubts whatsoever about performing do-it-yourself electrical work, PLEASE do the smart thing and hire a qualified and licensed electrician to perform the work for you.NEVER WORK WITH LIVE VOLTAGE. Always disconnect the power source before working with electrical circuits.When performing electrical work, ALWAYS READ AND FOLLOW THE MANUFACTURERS INSTRUCTIONS AND SAFETY GUIDELINES. Always follow your local electrical code and requirements which are specific to local areas.By utilizing this video and the information given, YOU are expressly holding "FIX THIS HOUSE" HARMLESS FOR ANY PROPERTY DAMAGE, PERSONAL INJURY AND/OR DEATH, OR ANY OTHER LOSS OR DAMAGE THAT MAY RESULT FROM YOUR ACTIONS. Viewers must be aware by doing projects on their homes they are doing it at their own risk and Fix This House cannot be held liable if they cause any damage to their homes. Fix This House and all parties associated with it ARE NOT responsible for the use and results of this information by any party, especially those lacking sufficient skill or knowledge to perform these steps safely and ANY HAZARD CREATED IS THE SOLE RESPONSIBILITY OF THE USER.
    DISCLAIMER: This video contains affiliate links, which means that if you click on one of the product links, I’ll receive a small commission.
    #outlet #switch #GFCI
  • ХоббиХобби

Комментарии • 82

  • @Tgail1
    @Tgail1 2 года назад +4

    Great video! My kitchen doesn't have nearly enough outlets. Thank you!

    • @FixThisHouse
      @FixThisHouse  2 года назад +1

      Thank you so much for watching! 🙏🏽😊

    • @danielmcdougle6925
      @danielmcdougle6925 2 года назад +1

      All kitchen receptacles should be gfci and afci protected per code. Don't line side your new receps and use dual function device not just gfci

  • @jbnotbot4654
    @jbnotbot4654 Год назад +5

    Very informative video for a beginner. Thanks for the great communication.

    • @FixThisHouse
      @FixThisHouse  Год назад +1

      Thank you so much for the love and support! 🙏🏽😊

  • @realreid9355
    @realreid9355 8 месяцев назад +1

    This great information is very much appreciated 👍

  • @hang4963
    @hang4963 Год назад +1

    Learn something new again Sir 🙏😝👍👍👍

  • @MarcEvans-lj1rk
    @MarcEvans-lj1rk Год назад

    Perfect presentation!

  • @wesheriveaux9325
    @wesheriveaux9325 7 месяцев назад

    Very helpful video, thanks

  • @sam.man.TX22
    @sam.man.TX22 10 месяцев назад +2

    Extremely well done and shown.

    • @FixThisHouse
      @FixThisHouse  10 месяцев назад

      Thank you! 🙏🏽😊

    • @versatile.mindset
      @versatile.mindset Месяц назад

      Could've installed without the pig tails though, hence the 2 holes per screw for this reason.

  • @user-uo4yv2or5q
    @user-uo4yv2or5q 2 года назад +1

    Thank you, that’s really helpful !

    • @FixThisHouse
      @FixThisHouse  2 года назад

      I’m glad I could be of help! 🙏🏽😊 thank you for watching 👍🏽!

  • @cherylseaangel153
    @cherylseaangel153 Год назад

    Hello, thank you for this video, it is exactly what I was looking for. In my garage I have a GFCI that is on the other side of the garage from the sink. Unfortunately for me the GFCI is the outlet closest to my Landscape Irrigation timer thus when it trips (and it has when I was out of the country) my landscaping & grass was almost dead from the Texas heat.
    Would it be possible to put the GFCI & the other outlet in a double gang box?
    I really would like to pull power from this GFCI and add another outlet in an upper cabinet so that I can plug in my battery chargers out of sight.

  • @jayp3687
    @jayp3687 2 года назад +1

    Ur channel is fuego 🔥 my guy👍🏼.

    • @FixThisHouse
      @FixThisHouse  2 года назад

      Thank you 🙏🏽! Gracias! 🙏🏽😊

  • @Lovetoflyeast
    @Lovetoflyeast Год назад +1

    question : can this connection goes first to none GFI plug and to a GFI plug ? thanks for the great video you know how to make it simple.

  • @HungNguyen-sb1yu
    @HungNguyen-sb1yu Год назад

    I have an outlet in my bathroom, no GFCI. Can I add a GFCI using the wires from that outlet for a bidet? Thank you so much for your help.

  • @VideoByPatrick
    @VideoByPatrick 21 день назад

    When do u use the load screws on gfi receptacle?

  • @garyczerkas9924
    @garyczerkas9924 2 месяца назад

    Excellent video....this did not fix my issue with the load of the GFCI tripping my plug, but it is very well done.

    • @kaden2112
      @kaden2112 Месяц назад

      No enough power, faulty wiring or whatever you have plugged in is messed up. Sometimes rope lights will trip the plug if one bulb goes bad and is either getting wet or is just bad

  • @nahpungnome
    @nahpungnome Год назад +3

    Thank you for this video. When we had our bathrooms remodeled, our contractor put GFCI outlets as required by the sink, but the circuit that it's on also has bathroom outlets on it (older home). Every time the bathroom GFCI triggered, all of our bedroom outlets would lose power because they hooked up the downstream to the load connectors. I've rewired my GFCI outlets this way and now triggering the bathroom outlets don't cause loss of power to our bedrooms.

    • @glasshalffull2930
      @glasshalffull2930 Год назад

      Congratulations! You’ve made all the bedroom receptacles less safe. BTW- why is the GFCI tripping so often in your bathroom? I’ve been in my house with GFCI in the bathroom for 22 years and it has only tripped three or four times. Maybe you should replace the GFCI receptacle as it may be defective.

    • @nahpungnome
      @nahpungnome Год назад +2

      @@glasshalffull2930 less safe how? The bedroom outlets aren't near water. It trips often because it's near the sink and my kids splash water all over the place. I'd say the outlet in the bathroom is working as intended and doesn't need to kill all the bedroom outlets unless you can tell me a good reason for it or if it's required by code.

    • @glasshalffull2930
      @glasshalffull2930 Год назад

      @@nahpungnome Though the NEC ‘currently’ only requires GFCI in wet spaces, the industry encourages them to be installed in areas with increased activity and electronics. It’s just added protection for you and your family. For example, when my brother was about 8 he stuck a piece of wire into an outlet and there was quite a fireworks show. He was OK, but it could have been really bad. A GFCI would have protected him. Anyway, I really like the added protection they give, but I can understand your particular predicament. I’m totally serious, but perhaps an outdoor weatherproof cover is in order for the kids bathroom receptacle. Good luck!

  • @garintiger
    @garintiger Год назад

    I have existing GFCI outlet in the patio. I would like to add another outlet in the patio using power source from existing GFCI. Do you recommend the new outlet to be another GFCI or regular (not protected) outlet? Thank you.

  • @tamimorales1116
    @tamimorales1116 Год назад

    Can it be wired the opposite way? Reg receptical as the main source then attach a gfi in the bathroom on adjacent wall?

  • @joelblauvelt5062
    @joelblauvelt5062 4 месяца назад +1

    Plrase tell me: Why woudn't you simply wire to downstream terminals of GFCI & protect the other receptacle?

  • @stetsonforsure
    @stetsonforsure 3 месяца назад +3

    Correct me if I’m wrong but you are not supposed to use 15a outlets on a 20a breaker.

    • @versatile.mindset
      @versatile.mindset Месяц назад

      You are incorrect indeed, that receptacle is a duplex, which is accordingly to nec code unless it's a single receptacle then it is in violation of nec code.

  • @BuzzRetirementGarage
    @BuzzRetirementGarage 22 дня назад

    My situation: Breaker to GFCI no ground wire. Line in....load out.... to next non-GFCI outlet. Outlet has power but shows open ground. Ok or nah?

  • @rainmantube1
    @rainmantube1 Год назад

    I installed a GFCI outlet and the little green LED light is on. So I assume it's supplying power. Yet when I plug in an appliance it gets now power. What does this mean?

  • @KL4life
    @KL4life Месяц назад

    Romex pliers highly suggest you imvest in one instead of making box cutter cuts into the jacket potentially slicing up the conductor

  • @djttv
    @djttv Год назад

    Hi, great video!
    At about 6:25 you specify connecting to the line side, not the load side. Could you explain that. What is line side, what is load side. Why use one and not the other.
    Thanks

    • @likefireflies
      @likefireflies Год назад +1

      you can think of the as entrances exits. Not a perfect analogy but it will work. The line side is the “entrance” - the wires that will supply electricity to the outlet. The load is the “exit” you can add more outlets after the gfci and they will be protected by the gfci. Which means you will also shut off everything that is attached to the load side when the interrupt is tripped. This can be good if you have multiple outlets on a countertop near a sink. They don’t all need to be gfci and still be protected when they branch off of the load side. If you have outlets and lights in other rooms that are down the branch though, every time it trips you will shut those off too which can be frustrating, that is when you would not use the load side.

  • @robertcasper4257
    @robertcasper4257 2 года назад

    Forgive me but are you recommending I use pigtails on every plug or switch I install? I normally wire directly to to wall wiring.

    • @FixThisHouse
      @FixThisHouse  2 года назад

      No worries! It’s your choice either way works 👍🏽😊

  • @keytothegate68
    @keytothegate68 8 месяцев назад

    Can you have gfci in both boxes?

  • @kvdgadj
    @kvdgadj 2 года назад +1

    Do you weaken the wood when you drill a hole through it?

    • @FixThisHouse
      @FixThisHouse  2 года назад

      Anytime you drill through anything it will weaken, as long as you comply with code 👍🏽😊

  • @DavidHernandez-st1uc
    @DavidHernandez-st1uc 7 месяцев назад

    Can I ad a light bulb after the outlet

  • @MaMa-qh4dy
    @MaMa-qh4dy 2 года назад +10

    Save the Wagos and just wire the line and load to the same side of the GFCI. There are 2 sets of lugs to accommodate that.

    • @aurvaroy6670
      @aurvaroy6670 Год назад +1

      True but the grounds still need to be pigtailed

  • @sheena_marie5936
    @sheena_marie5936 10 месяцев назад

    Can I ask you a question?almost all my receptacles in my home have no grounding and no GFCI receptacles .none in bathroom or kitchen well atleast they don’t have grounding I know for sure.so my question is would it be wiser and best for me to replace receptacles with a GFCI receptacle (even though there’s no grounding wire) or just add a GFCI circuit breaker in the panel box?and how many GFCI breakers would I need ??I have the main panel box and a sub panel box .home was built in 1957…im so confused with all this grounding GFCI stuff but I need my home to be safe

    • @surferdude642
      @surferdude642 10 месяцев назад

      Unless your main electrical panel has been replaced with a modem one, most likely there's no GFCI breaker available in your case. Short of a complete rewiring, GFCI receptacles are the only option.

  • @geraldrosella6247
    @geraldrosella6247 Год назад +3

    Is it OK to use 15-A outlet with a 20-A service?

    • @stanmarsh3910
      @stanmarsh3910 Год назад +2

      NO NO NO and one more NO lol unless you have full coverage home insurance and don't tell them what you did after the house fire. 15 amp breaker gets 14 g wire and 15a receptacle (outlet). a 20 amp breaker is 12 g wire with 12g receptacles.

  • @zaneblane8160
    @zaneblane8160 Год назад

    Do i have to pigtail?

  • @zachgoestoeuro
    @zachgoestoeuro Год назад

    What exactly made the non-gfci outlet not protected under the gfci receptacle? Because the gfci was pigtailed?

    • @luisz34nismo
      @luisz34nismo 11 месяцев назад

      Exactly and because the none gfci wasn’t connected to the gfci outlet

  • @pricklypear1111
    @pricklypear1111 7 месяцев назад

    Is those more cost effective than replacing all outlets on the same circuit GFCI outlets?

    • @Mark-cg4po
      @Mark-cg4po 4 месяца назад +1

      Making each outlet as a single location GFCI outlet is more expensive but arguably better so that if one outlet trips, the entire circuit doesn't trip.
      If you're changing a downstream protected circuit to make that GFCI only single location protected, it'll likely be against code if you do that. In every state I've lived places like a kitchen or garage need all outlets protected by GFCI, per code. Some homes do this with one GFCI protecting everything downstream from it (not single location like shown here). In those situations, it would be wired differently than this.
      When I've run my own circuits (all permitted), I do all single-location GFCI protected outlets. It's slightly more complex wiring pigtailling at each location and it's significantly more expensive, but it's the most reliable circuit.

  • @tb-xy7lg
    @tb-xy7lg Год назад

    Is it ok to just run the new outlet directly to the load side of the old outlet? Rather than make pigtails all going into the line? Hope that makes sense lol.

    • @PH-md8xp
      @PH-md8xp Год назад

      Yes you can do that if you want the downstream outlet to switch off when the gfci trips. Effectively that makes the downstream outlet protected by gfci.

  • @rodgerrabbit2955
    @rodgerrabbit2955 3 дня назад

    If you come out of the load side of a gfci to an outlet downstream, that outlet is gfci protected as well; as long as they are on the same circuit....
    Anything prior, from the panel box to the first gfci, is not protected. However, any duplex receptacles downstream that are on the same circuit will be protected.....

  • @davidmontalvo6560
    @davidmontalvo6560 Год назад +2

    Hey question, why would you NOT have the 2nd outlet protected by the GFCI?!! Outside of that I love your videos.

    • @GeorgieCt
      @GeorgieCt 8 месяцев назад

      I would think because like he said if the GFCI is by the sink and the other outlet, it’s not then it doesn’t really need to be protected, especially by code, so he wired it as a parallel circuit so if the GFCI guess what it will short out, but won’t affect the rest of the circuit.

  • @PINTO2O2O
    @PINTO2O2O 2 месяца назад

    what if my line was coming from the non protected outlet?

  • @acesandeights65
    @acesandeights65 5 дней назад

    Why not use 20 amp outlets since you have 20 amp breaker and wire?

  • @jerrybanks9216
    @jerrybanks9216 2 года назад +1

    Is it true that GFCI outlet can't protect other outlets

    • @FixThisHouse
      @FixThisHouse  2 года назад +1

      It can protect other outlets in the same circuit 👍🏽😊

    • @PH-md8xp
      @PH-md8xp Год назад

      @@FixThisHousebut the wiring needs to be connected to the load side of the gfci. This should be made clear in the video or in another video.

  • @danielleg2616
    @danielleg2616 Год назад

    what if the GFCI isn't turning off the other outlets in the circuit?

    • @GeorgieCt
      @GeorgieCt 8 месяцев назад

      That’s why he pigtailed it. And to answer your question they will be live. Need to hit the breaker at the panel. If he ran it up though the top two screws then the other outlets after or down stream will not receive power

  • @tina8796
    @tina8796 2 года назад +1

    my husband was just talking about this

    • @FixThisHouse
      @FixThisHouse  2 года назад

      Perfect timing! 🙏🏽😊👍🏽

  • @kazkylheku1221
    @kazkylheku1221 2 месяца назад

    Why would you not GFCI-protect the secondary outlet, if it's coming from a GFCI receptacle?
    There doesn't seem a downside to doing it.
    The secondary outlet is less safe because of this.
    About the only reason I can think of is that the second outlet is dedicated to a specific applicance, and that appliance is a source of nuisance GFCI tripping. Or else that appliance must be reliably on at all times, even if there is a nuisance GFCI tripping for some other reason.

  • @sgthunter21
    @sgthunter21 Год назад

    🇵🇭

  • @douglasdever6134
    @douglasdever6134 Год назад +1

    Why use pigtails to connect the wires from the breaker to the line side of the GFCI when you can just connect to the GFCI? Saves on those damn wags and allows for more space in the box. Understand the ground but no the other wires. Waste of time and money.

  • @rtoguidver3651
    @rtoguidver3651 Год назад

    Why would you want to bypass the GFCI to the next outlet..
    GFCI is designed to be a sensitive breaker 3 to 4 milliamps, so it trips before the breaker in the main panel does..
    The way you have it, the outlet will trip the breaker in the panel and then both of these will be off anyway..
    If the outlets in the bathroom are tied into the GFCI, than they all follow code.

    • @surferdude642
      @surferdude642 Год назад

      A gfci receptacle is not a circuit breaker and only detects small current leakage, then trips. It does not detect short or over loaded circuits.

    • @glasshalffull2930
      @glasshalffull2930 Год назад +3

      An example I can think of is if you have a freezer downstream of the GFCI. The GFCI may be near a sink where it is required, but you don’t want it tripping and ruining your food.

  • @DrivebySermons
    @DrivebySermons 2 года назад

    I would like to know what this purpose of this video is. There are very few situations where you would want to do this without violating code, and by the comments people are confused by what you even did.

    • @FixThisHouse
      @FixThisHouse  2 года назад

      You are the first who asked this question on the comments sir.

    • @douglasmoore9918
      @douglasmoore9918 2 года назад +2

      He makes it quite clear: code requires GFCI protection for outlets within 6ft of the wet space. If the outlet is further than 6ft then you may want it to remain powered even when the GGCI pops. He demonstrated that, and he pointed out such a downstream outlet would have to be more than 6ft from the wet space. Perhaps he could have put one of his flags to emphasize that, in case someone didn't watch the entire video carefully to understand all of the points he makes.

    • @DrivebySermons
      @DrivebySermons 2 года назад

      @@douglasmoore9918 Residencial code requires all receptacles in a kitchen to be GFI protected. Also in residential code, kitchen circuit and bathroom circuits are dedicated, so if you are adding receptacles to the circuit they should be GFI protected. This channel seems to be dedicated to Residentail DIY work, however somethings should not be done DIY. Some of the comments are people talking about adding receptacles in their kitchen, this video would not apply to them, however when he responded to the comment he made no mention of that.

    • @douglasmoore9918
      @douglasmoore9918 2 года назад

      @Jonathan Chamblee I see your point that the circumstance for this type of arrangement would be rare. In my case, I'm planning to put a wash sink in the corner of a work room. I'm thinking of GFCI protecting outlets within 6 feet but use his technique to power the ones further away. Would that be a bad thing? I'm worried that running a large printer, paper, etcher, or such would pop the GGCI?

    • @nostep3966
      @nostep3966 Год назад

      @@DrivebySermons what about an outlet for a refrigerator that says not to be plugged into gfci?