IMPROVE "F3" ERROR AC SPLIT DAIKIN INVERTER 1 PK

Поделиться
HTML-код
  • Опубликовано: 12 дек 2024
  • "F3" error on split ac with an inverter due to the error of the exhaust pipe temperature in the outdoor. (outdoor thermistor sensor) there are 3 types of discharge pipe sensor, reverse pipe sensor, outdoor temperature sensor, of the three types of sensors that read the outdoor working temperature and provide a signal to the inverter module.
    "F3" error can be caused by lack of freon, outdoor thermistor sensor is damaged / misread temperature, electronic expansion valve is broken, body valve expansion is broken, pcb inverter module is error / damaged.
    Here I use a capillary pipe to replace the damaged valve expansion. Sy, don't recommend friends to replace it with capillary pipes, but so far there are no problems for its use, the AC still wants to cool at low, med, high comp speed.
    Hopefully this will be useful for all my friends and if there are feedback or comments please write below the comments column.
    Don't forget to like and subscribe, friends - thanks.

Комментарии • 304

  • @berbagitau1019
    @berbagitau1019 Год назад +1

    Ilmu yg bermanfaat..semoga tmbh mju dah berkembang

  • @ahmadjamil8818
    @ahmadjamil8818 7 месяцев назад

    Wah ini mah teknisi ac yg udah pro..ngerti cara kerja komponen ac..

  • @bahribahri228
    @bahribahri228 3 года назад +2

    Trimakasih mas bagi bagi ilmu TUHAN BERKATI AMIN

  • @bahribahri228
    @bahribahri228 3 года назад +1

    Trimakasih mas bagi bagi ilmu saya trimasih banyak

  • @jovanoriechie8129
    @jovanoriechie8129 4 года назад +2

    Bli sy subcribe.., semoga sewaktu2 bisa share ilmu utk problem yg belum pernah sy atasi. Thxs

    • @jovanoriechie8129
      @jovanoriechie8129 4 года назад

      Bli., boleh minta kontak WA untuk tanya2 soal AC. Terima kasih

  • @alphaservice191
    @alphaservice191 2 года назад

    Mantab kang,salam dingin dari indarung padang,terimakasih

  • @iyanservice0556
    @iyanservice0556 5 лет назад +1

    Okee mass terimasih atass videonya,, saya bertahun2 benam AC daikin inverter..
    Kedip2 jg luar dlm,, saya bongkar2 vcb nya..
    Gak jg

    • @aripazu3716
      @aripazu3716 4 года назад

      Coba mas kabel2 kontrolnya mungkin ada yg gak kenceng, sy jg ngalamin pusing n ribet.

  • @bahribahri228
    @bahribahri228 3 года назад +2

    Trimakasih mas nambah sy ilmu sekali lagi trimakasih

  • @sugengsugeng9471
    @sugengsugeng9471 4 года назад +1

    mantab nas,nambah wawasan

    • @madearsa93
      @madearsa93  4 года назад

      Terimakasi mas sugeng

    • @imanueljulian6495
      @imanueljulian6495 4 года назад

      Made arsa..mau tanya, itu tadi motorized coil nya tidak dipasang ? Ndak pengaruh pada pcb outdoor..terimakasih

  • @fajarnugroho646
    @fajarnugroho646 5 лет назад

    Salam dari bali...ikut belajar bli

  • @irilhandoko1856
    @irilhandoko1856 4 года назад +1

    Mantab made .......

  • @nazacom2152
    @nazacom2152 8 месяцев назад

    Thnkyu sob... itu Ac brp PK ya, dan brp panjang kapiler nya..? 🙏👍

  • @kikikiki3941
    @kikikiki3941 3 года назад

    Trimakasih 👍👍

  • @muhamadsaddam3845
    @muhamadsaddam3845 3 года назад +1

    Kalw katup exspansi d ganti dengan pipa kapiler, sensor.y delepas aja apa di pasang gan.

  • @siagaopspoldasumbar5579
    @siagaopspoldasumbar5579 5 лет назад +28

    sekedar masukan bli... gak baik bagi kompresor ac inverter klo ekspansinya diganti dengan kapiler. karena desain ac inverter harus menggunakan katup ekspansi dimana fungsi ekspansi adalah selain pengganti kapiler pada sirkulasi freon tetapi juga menjaga tekanan pada pipa tekan dan pipa hisap agar berada pada tekanan yang seharusnya. karena ac inverter kompresornya bekerja secara variabel. maksudnya ketika kompresor berjalan pada medium speed maka ekspansi akan menyempit dan apa bila kompresor berjalan pada high speed maka ekspansi akan melebar agar perbandingan tekanan tetap pada takaran yang semestinya. jika diganti dengan kapiler maka penyempitan pada sirkulasi freon akan terjadi secara flat (tetap). alhasil kompresor pada kecepatan rendah sirkulasi freon akan mendekati loss di kapilernya yang mengakibatkan tidak terjadinya pengabutan freon dikapilernya dan tidak mengahasilkan dingin dan jika diukur tekanan pada pipa tekan pada kompresor akan turun dan tekanan pada pipa hisap akan naik dari yang semestinya. sementara jika kompresor berjalan pada high speed atau kecepatan tinggi maka tekanan pada pipa tekan kompresor akan naik tinggi sedangkan pada pipa hisap akan rendah dari yang semestinya, walau pada kecepatan high speed ac akan menghasilkan dingin tetapi akan mengakibatkan kompresor dipaksa bekerja diatas batas kemampuan semestinya untuk memompa dikarnakan debit aliran freon yang diterima kapiler sudah di atas yang semestinya. ini akan membuat kompresor tidak akan bertahan lama.... saran untuk ac inverter jika ekspansinya rusak, alangkah baiknya diganti dengan ekspansi yang baru ketimbang diganti dengan kapiler... karena ac inverter tidak sama dengan ac non inverter.. atau jika suku cadang tidak ada di daerah sekitar tempat tinggal atau terlalu mahal maka opsi kedua lebih baik ac nya dijadikan non iverter dulu baru di ganti dengan kapiler...

    • @alvinarmianto2792
      @alvinarmianto2792 5 лет назад +1

      Mantapss mAs sarannya masuk akan dan Kerennn

    • @riyadigepeng1828
      @riyadigepeng1828 5 лет назад

      Kalau inverter daikin eror L5 solusinya apa bos ku?

    • @deniindarto2989
      @deniindarto2989 5 лет назад +2

      ciri" katup exspansi rusak gimna ya bang ?

    • @fianissa983
      @fianissa983 5 лет назад +2

      punya saya di ganti kapiler sudah 3 tahun ke skrg ga masalah ampere normal,mau ganti katup ekspansi waktu itu harganya selangit.

    • @amirherisusanto8669
      @amirherisusanto8669 3 года назад

      Ter merubah kompresor inverter 3phase menjadi manual, apa kah cukup coneksi S,C,R L,N, dan kapasitor?

  • @ariefyenny9959
    @ariefyenny9959 3 года назад +1

    Ok. Baik

  • @vivo1269
    @vivo1269 3 года назад +1

    Bos Sayaa Mau Tanya daikin split duct 2.5 Pk..Fan outdooor nyala tapi compresskr Ga manggil..walaau indoor nyalaah.di cek remot kode error ga terdetek

  • @oscarrj.mataniari1658
    @oscarrj.mataniari1658 4 года назад

    Bli... mau tanya donk..sy lg service ac.. Metk LG, inverter 1 PK.. problennya, saat dinyalakan pertama, putaran compressor low ( 2,4 amper..sesudah 2 menit hidup, puteran compressor naik dan ampelr menjadi 3.4 amper..sesudah 2 menit kwmudian, puteran naik lagi jadi 5-6 amper..hampir 3x yg teryera di nameplate (name plate 3.3 amp).. apa penyebabnya bli..trimkasih.salam dingin dari tangerang

  • @sugiyono0661
    @sugiyono0661 5 лет назад +1

    Ok makasih

  • @budiartotenosa5433
    @budiartotenosa5433 4 года назад

    Kalah profesor jepang sm oi😄

    • @madearsa93
      @madearsa93  4 года назад

      Hahaha, maaf sy juga baru belajar, memang bisa di gunakan ganti dengan kapiler bisa normal kembali, munkin pd setingan low watt agak kurang dingin sedikit tp tidak terlalu signifikan, dr pengalaman sy pribadi.

  • @adicahyadi5803
    @adicahyadi5803 3 года назад

    Metaken pak de..kenapa tdk d vacum ya? R32 kan wajib vcum..apalagi itu invrter. Kmudian apa pipa kapiler bisa mengatur volume gas spt elektronik expnsi valp? Apa masih bisa hemat listrik klo sudah di modif spt nike?ampure masih belajar pak made.. 🙏

    • @madearsa93
      @madearsa93  3 года назад

      Divacum lebih baiknya...! Daya listrik masih hemat seperti biasa hanya saja jika seting low watt di remote dingin nya agak kurang sedikit seperti biasanya.

  • @yogatanaka5544
    @yogatanaka5544 5 лет назад +1

    Utk area jakarta ada? Saya kena f3 juga

  • @torjackkaratan6081
    @torjackkaratan6081 3 года назад

    After your modification sir.. In several week or months no have problem afyer you change expansion valve to capillary? Tnx for your response..

  • @sarudiandika7567
    @sarudiandika7567 4 года назад +1

    Sahabat thenik info .
    AC emperter Daikin 1 pk
    Tdk eror ..
    Permasalahannya
    Compresor .hidup dlm watu pling lama 5 menit ..setelah dlm 5 MIT mati lgi tu compresor .nunggu smpi 20 mnt .baru bisa hidup .treus mati lgi ....aph tu kerusakannxa

    • @madearsa93
      @madearsa93  4 года назад

      Blum bisa di simpulkan apa kerusakannya, karena kurang detail pengecekan posisi outdoor ac hidup ampere berapa? Tekanan freon berapa? Sudah dpt cleaning ac indoor dan outdoor?
      Ada indikasi kode errornya apa? Trims

    • @filzafarzana2166
      @filzafarzana2166 3 года назад

      @@madearsa93 lo ac 1 1/5 ukran kapiler brp kh

  • @mrdiycool2062
    @mrdiycool2062 4 года назад

    Udah subcribe mas

  • @azenkmaulana2229
    @azenkmaulana2229 5 лет назад

    Tquuuuu.. Brother !

  • @warsobaru7309
    @warsobaru7309 3 года назад +1

    Maaf bos, kl koder error' H6 ac Daikin inverter 1pk, kira2 ada kerusakan di komponen bagian mana bos..?🙏

    • @madearsa93
      @madearsa93  3 года назад

      Bisa modul pcb outdoor, dan bisa juga kompresor.

  • @saifulbakhari2105
    @saifulbakhari2105 3 года назад +1

    Error f3 .ekpansi valvenya di ganti kapilr. Untuk 2pk panjang berapa diameter berapa. Lalu selenoid nya dicabut atao di biarkan saja. Terimakasih.

    • @madearsa93
      @madearsa93  3 года назад

      2pk ukuran kapiler 80mm panjang 60cm , motorize expansi di cabut.

  • @hlathein5558
    @hlathein5558 4 года назад

    Thank you sir

  • @zarifin46somayasulimanzari44
    @zarifin46somayasulimanzari44 5 лет назад +3

    Om mau nanya nih AC Daikin 1pk invater saat di nyalahin di lampu indor nya kedap kedip lalu berapa menit AC nya mati lalu dinyalahin lagi tetap gak lm mati lg tp pake kode pan ttp menyalah pas kita kasih kode cool AC nya mati lg dan kira² apaan nya yg jd travel om.?🙏 Mksh sblm nya om.🙏

  • @otangsetiawan5780
    @otangsetiawan5780 Год назад

    bang kalo sudah ganti ke kapiler apakah future Low watt nya masih bisa berfungsi atau gk?

  • @berbagitau1019
    @berbagitau1019 Год назад

    Gan..klau utk 1/2 pk menggunakan pipa kapiler ukuran brapa?

  • @ubn4046
    @ubn4046 4 года назад +1

    Cara kerja anda sudah saya kerjakan ac suda ok tapi aneh nya setelah 3 hari ac daikin inverter 1pk kumat lagi yaitu out door mati lagi freon r.410a nya kondisi ok ga bocor.

    • @madearsa93
      @madearsa93  4 года назад +2

      Error f3 adalah kesalahan kontrol suhu deteksi pd thermistor pipa discharge.
      Bnyk faktor yg menyebabkan error f3 , bisa karena 3 sensor thermistor pd outdoor yg rusak, kebocoran freon, bisa juga pcb outdoor itu yg rusak. Perlu menganalisa kerusakan pd error f3 tidak semua kerusakan pd body expansi dan eletronic expansinya yg sudah di rubah dgn pipa kapiler.
      Perhatikan panas suhu pd pipa discharge kompresor.
      Perhatikan tekanan freon dan ampere pd saat start kompresor hingga running kompressor di posisi ngegas putaran tinggi, apakah ampere mengikuti kerja kompresor pada putaran bawah dan putaran atas tidak melebihi ampere yg di tentukan di putaran tinggi sampai 4,5 A, dan tekanan freon perhatikan pada jarum manifol dari putaran bawah kompresor stabil turun jarum manifol di 170-180psi hingga putaran tinggi di tekanan 140-150psi. Untuk ac freon r32 atau r410a

  • @joeteknik4556
    @joeteknik4556 3 года назад

    Mau tanya bli... Klo Daikin multi split bisa kah diganti kapiler jg? Soalnya ada 2 katup ekspansi/selenoid Valve.

  • @hamzahal6693
    @hamzahal6693 Месяц назад

    Mslah AC sya sama persis dgn di video.
    Mau tanya bang itu ampere nya idealnya 3,4-3,8 ya bang. Klo ampere nya dibawah nilai standard knpa ya bang?

  • @Dhirzky
    @Dhirzky 4 года назад +1

    Bli, tanya AC DAIKIN 1/2 PK SMILE INVERTER saya ketika di hidupkan 2mnt outdoor mati dan indoor tetap running setelahny LED power berkedip indikasi error' L5? Mohon bimbingannya?

    • @suyonouton9169
      @suyonouton9169 4 года назад

      Jika diganti pipa kapirel gitu kira"berbahaya ga,dan brpa lama bisa tahan

    • @Dhirzky
      @Dhirzky 4 года назад

      @@suyonouton9169 kalo masih 3 tahun mending manggil service resmi. Masih free

  • @kayanbaztard13
    @kayanbaztard13 3 года назад +1

    Klo untuk ac ukuran 1,5pk brapa ukuran pipa kapiler dan panjangnya bli? 🙏
    Ampura kari pemula.

    • @madearsa93
      @madearsa93  3 года назад +1

      Biasanya di gunakan ukuran 0,70mm panjang 60cm

    • @kayanbaztard13
      @kayanbaztard13 3 года назад

      @@madearsa93 oke, suksma bli 🙏

  • @agusrevolusi1329
    @agusrevolusi1329 Год назад

    Pak eror u4 inverter daikin yg kerusakannya bagian apa ya.trim ksh.

  • @joeteknik4556
    @joeteknik4556 3 года назад +1

    Udah nyoba ini kelemahannya ko multi split, ga bisa 1 indoor aja yg menyala, harus 2 2 nya menyala karena freon mengalir ke indoor yg lainya jg.

  • @dominicxavier7384
    @dominicxavier7384 5 лет назад +2

    Setelah di ganti kapilernya.ekspansi elektronik nya di ke mana kan yah mas?

    • @madearsa93
      @madearsa93  5 лет назад

      Saya lepas, kalo dia protek di pasang aja pinggirin taruhnya

    • @hadipurwanto9447
      @hadipurwanto9447 3 года назад

      Made Arsa...
      Di lepas tanpa di jemper..? Atau di jemper..?

    • @theremacoofficial7045
      @theremacoofficial7045 2 года назад

      Maksudnya socket nya dilepas dari pcb ya bli, atau socket tetap terpasang di pcb

  • @tigasekawan321
    @tigasekawan321 3 года назад +1

    dingin sih mungkin bisa maksimal,tapi pemakain itu kuat berapa jam???
    karena dikasus yg hampir sama seperti ac ini pemakain yg saya uju ini hanya bertahan kurang lebih 5-6 jam setelah itu ac kembali ngetri lagi.
    mohon bimbingannya....

    • @madearsa93
      @madearsa93  3 года назад +1

      Cek termistor nya bisa jadi rusak.

  • @pancafamily8975
    @pancafamily8975 3 года назад +1

    Bli Made ada wa???
    AC saya rusak Daikin inverter r32, outdornya nyala sebentar, belum dingin sudah mati.

  • @midasumiarsa5911
    @midasumiarsa5911 5 лет назад +2

    Pas AC Daikin Inverter 1PK saya krna F3. Terima service AC bli? Ada kontak yang bisa di hubungi?

    • @agustitimurti4814
      @agustitimurti4814 5 лет назад

      Ada ..alamat nya di mana biar kita datangi .. khusus Medan ya .. 🙏

    • @madearsa93
      @madearsa93  5 лет назад

      081 999 021 433 daerah denpasar - bali

  • @alfakrisbiantoro6718
    @alfakrisbiantoro6718 3 года назад

    Untuk info harganya bang . . .share dong harganya . . Dapet kasus sama untuk daikin inverter 1 pk model lama

  • @Ariefindragunawan
    @Ariefindragunawan 5 лет назад

    Bang mau tanya nih..ac sya daikin inverter 1/2 pk..habis ganti pipa elbow indoor gara2 bocor..usia ac baru 1 stngah thun..setelah seleasai servis..dah berjalan hampir sebulan lebih..dingin mash kurang nyess..tekanan freon normal di cek kode eror remote ga gak ada yg eror..dinginyya kurang nyess..aer pembuangan embun ac normal bgt klo di suhu 25..tpi klo di turun ke 24 atau 23 sma aja gak ada perubahan dinginya..malah aer pembuangan embun mlah jadi agak lambat..padahal sebelumny di suhu 25 aja dah dingin banget sebelum penggantian pipa elbowny...kira2 apa ya solusiny..
    Mhon penjelasany..

    • @madearsa93
      @madearsa93  5 лет назад

      Bisa jadi pada saat perbaikan kebocoran, sirkulasi pipa ac kurang dibersihkan dan tidak di vacuum, kurangnya tekanan freon, sirkulasi pipa pendinginan terhambat sedikit buntu jadi pendingin tidak normal kurang dingin.

    • @Ariefindragunawan
      @Ariefindragunawan 5 лет назад

      Secara prosdur di vacum..tpi yah gtu saya suruh cek kembali tekanan freon sma besar ampereny smpe skrg teknisiny blm dtng2 jg krmh..

  • @andyziian5767
    @andyziian5767 3 года назад

    Colek.. suhu made Dulu...

  • @ahmadaircon7818
    @ahmadaircon7818 3 года назад

    Bagaimana bisa tentu kan mana satu yg rosak..? Sensor? Eev atau pcb

  • @ariefudien7034
    @ariefudien7034 4 года назад

    apakah untuk ac samsung ,bisa juga di kasi seperti daikin

  • @iqbalagustina8440
    @iqbalagustina8440 4 года назад +1

    Kalo untuk ac 1.stngah pk pake pipa kapiler ukuran berapa

  • @rendi.m.u1968
    @rendi.m.u1968 4 года назад +1

    AC inverter lebih ribet perbaikinya.
    Kalau bisa di ganti aja mas jangan di rubah rubah gitu GK baik.🙏😁

    • @Anadisty
      @Anadisty 3 года назад +1

      Kalo punya uang banyak gpp bang main ganti" aja tapi kalo masih bisa diakalin dengan nominal yg kecil kn gak salah juga

  • @andieazhiez5934
    @andieazhiez5934 5 месяцев назад

    Untuk AC 1/5 PK pipa kalilernya ukuran berapa yah?

  • @faisalsiregar6409
    @faisalsiregar6409 3 года назад

    Bagaimana kita tau kalau expansi valevnya rusak. Dilihat dari fisik atau ada bunyi2 atau bagaimana pak.

    • @madearsa93
      @madearsa93  3 года назад

      Di cek lewat manifold tekanan freon dan ampere nya. Kompresor hidup seiring jalan putaran speed kompresor tekanan freon turun sampai habis dan ampere kompresor tinggi melebihi batas ampere dan overload.

  • @redmi4a782
    @redmi4a782 4 года назад +1

    Itu dinginya bisa maksimal ga bro?? TRIms infonya

    • @madearsa93
      @madearsa93  4 года назад +1

      Bisa, normal dingin seperti biasa.., tapi kalo disetting low watt di remote agak kurang dingin karena kompresor pada low speed di putaran bawah, fungsi katup expansi sudah tidak ada jadi loss konstan menggunakan kapiler, jika kompresor ngegas pd putaran atas dinginnya normal seperti biasa.

  • @ben096
    @ben096 4 года назад +2

    Tak boleh modified expenses valve begitu ,AC sudah hilang digital thermal energy control kalau Di ganti dengan capillaries. Warranty dari Daikin langsung void Di modified begitu .

    • @aditianugraha4712
      @aditianugraha4712 4 года назад +2

      Betul sekali otomatis system tidak akan bekerja dengan baik, di kemudian hari akan ada error tambahan

  • @agunghidayatullah1320
    @agunghidayatullah1320 2 года назад

    Bli Untuk pastikan body expansi rusak/bagus bgaimana caranya ya bli?

  • @muhammadtaufiq7051
    @muhammadtaufiq7051 3 года назад +1

    Klo expamsi valve rusak, out door nya mati hidup atau gmn pak? 🙏

    • @madearsa93
      @madearsa93  3 года назад +1

      Iya mati-hidup, compressor overheat

  • @donyilham7285
    @donyilham7285 4 года назад

    Mau tanya dr jember jawa timur ,van hidup yg jalur konpresor mati hidup sebentar itu kira2 dari apa ya mas....

  • @rudalsqud926
    @rudalsqud926 4 года назад +1

    Apa setiap kode error F3 seperti ini kerusakannya?.. mohon infonya, terima kasih

    • @madearsa93
      @madearsa93  4 года назад

      Penyebab error F3 bnyk indikasi bisa dari kebocoran freon, expansi valve rusak, elektronik expansi rusak, sensor thermis discahrge rusak, pcb outdoor rusak. Harus di cek dulu dan di pastikan di bagian mana yg rusak.

  • @almerkev
    @almerkev 2 года назад

    Halo mas, mau bertanya nih. Ac inverter daikin 1pk saya ada masalah di sensor magnet valve nya, kalau di pasang.. outdoornya mati, namun kalo di copot, outdoor nya nyala. Sudah beli magnet valve baru, namun tidak ada perubahan.. mau di copot tapi takut nantinya akan rusak merembet. Nah ada saran, pipa nya diganti menjadi kapiler.. apakah aman mas?

    • @arapaimagold8088
      @arapaimagold8088 Год назад +1

      AC kalau pakai EEV, maka di pcb akan ada IC stepper untuk ngatur EEVnya. Itu juga harus anda ganti.

  • @fachmishahab2872
    @fachmishahab2872 4 года назад

    Persis sama spt AC Daikin 1 PK inverter saya.F3 error...kmd ..dibersihkan karat2 pd sensor2 itu....berhasil...kmd dingin...namun cuma bertahan 3 bulan...kmd F3 error lagi....kl begini apa solusinya Mas?

    • @madearsa93
      @madearsa93  4 года назад

      Ganti body expansi valve dan elektronic expansi nya kemungkinan rusak.

  • @ardypermadi2310
    @ardypermadi2310 5 лет назад +1

    Pernah nangani error u2 bli AC seperti itu,jd klu di mode low watt ac jalan normal.tp klu di mode normal outdoornya mati hidup....

    • @ardypermadi2310
      @ardypermadi2310 5 лет назад +1

      @@madearsa93 sudah pernah tp hasilnya sama cek teg input 220 normal,system kelistrikan jg normal pakai 4 kabel standart pemasangan daikin,kompressor jg tdk short. blm di cek bagian modulnya karena tdk punya skemanya.

    • @ardypermadi2310
      @ardypermadi2310 5 лет назад +1

      @@madearsa93 oke terima kasih banyak bli made atas ilmunya,coba saya pelajari dl system kerjanya besok 🙏

    • @nobieanynomous2424
      @nobieanynomous2424 5 лет назад +1

      Ardy Permadi
      biasanya u2 modul pcb outdoornya bermasalah.. cek sekring, kapasitor, biasanya kapasitor dc nya itu bang

    • @masmincoolteknik8033
      @masmincoolteknik8033 5 лет назад +2

      Pcb noise filter dan fan motor outdorr

    • @raihanraqqilla3186
      @raihanraqqilla3186 4 года назад +1

      @@masmincoolteknik8033 ganti kapasitor VDC di outdoor

  • @komangkariasa4761
    @komangkariasa4761 3 года назад

    Maaf maksudnya controlnya di lepas atau dibiarin ?

  • @budiarimbawa334
    @budiarimbawa334 2 года назад

    Mau nanya bli
    Ac daikin inverter stengah pk waktu ac hidup
    DinginNya hanya mau 15 menit
    Stelah itu compresor tambah panas jarum manipol naik terus dan
    Amper di compresor naik terus
    Stelah itu dinginNya hilang
    Kira "dimana rusakNya bli tolong solusinya bli,,🙏

  • @wahyuardian9729
    @wahyuardian9729 5 лет назад

    Itu kira kira bermasalahny apa ya om kalau termistor out sm exvansi dg error f3

    • @wahyuardian9729
      @wahyuardian9729 5 лет назад

      Apakah ciri ciriny kompressor panas atau kompressor dingin

  • @hobyserviceabalabal7670
    @hobyserviceabalabal7670 3 года назад +1

    kalo error E6 biasanya kompresor macet apa modulnya bli

  • @A_dhit_a_m_a
    @A_dhit_a_m_a 4 года назад +1

    AC punya saya sensor yg diluarnya putus kayaknya bagian dalamnya, soalnya kegencet tutup atas. Waktu AC abis di cuci tidak memperhatikan ternyata kabel sensornya kegencet.
    Untuk menggantinya gimana ya? Atau bisakah kabelnya disambung? Saya belum coba liat daleman kabelnya seperti apa.

    • @madearsa93
      @madearsa93  4 года назад

      Pd outdoor ac sensor thermis putus ?

    • @A_dhit_a_m_a
      @A_dhit_a_m_a 4 года назад

      Iya, thermistor yg ada dibagian luar belakang AC sepertinya putus bagian dalam kabelnya, soalnya kegencet tutup atas casing outdoor. Itu kabel isinya tembaga atau apa ya? Kalo tembaga bisa disambung kan?

    • @madearsa93
      @madearsa93  4 года назад

      Ow, iya bisa di sambung kabel thermisnya.

  • @komangkariasa4761
    @komangkariasa4761 3 года назад

    Pak mau tanya apa expansi nya dicabut dari vcbnya atau dibiarin ?

  • @ediprayitno6946
    @ediprayitno6946 3 года назад

    Minta skema expasi valvenya om 6 kabel mana yg negati dan positifnya

  • @yulisudarwanto7341
    @yulisudarwanto7341 5 лет назад

    @made arsa ada nomer
    g bisa di hibungi mas.mau tanya ilmu nya dan sedikit curhat tentang permalahan ac inverter 1 pk.saya baru belajar dari 0

  • @meethos
    @meethos 4 года назад

    Bli made izin tanya , untuk kode error F6, Sudah pernah menqngabi kah?

    • @madearsa93
      @madearsa93  4 года назад

      Error F6 kontrol Tekanan Tinggi dalam Pendinginan
      Metode
      Pendeteksian
      Kode Error
      Kontrol tekanan tinggi (Operasi berhenti, penurunan frekuensi, dll) diaktifkan dalam operasi
      pendinginan jika suhu dirasakan oleh Termistor Penukar Panas outdoor melebihi batas.
      Kondisi Keputusan Error
       Suhu dirasakan oleh Termistor Penukar Panas outdoor naik di atas 60 ° C.
       Kesalahan menjadi jelas ketika suhu turun di bawah sekitar 55 ° C.
      Dugaan Penyebab
       Ruang instalasi tidak cukup besar.
       Heat Exchanger outdoor Kotor
       Fan motor outdoor rusak
       Stop valve rusak
       Katup ekspansi elektronik atau kumparan rusak
       Termistor Penukar Panas outdoor
       PCB Unit Outdoor rusak

    • @bintankuchiha3374
      @bintankuchiha3374 2 года назад

      Ngatasinnya gmn?

  • @masukgenk3903
    @masukgenk3903 3 года назад

    Bli,
    Sepertinya kasusnya mirip dgn ac saya,
    Indoor tidak mau dingin, ketika baru ON, lalu outdoornya harus di semprot air dulu baru mau dingin indoornya,
    Apakah kasus demikian masalahnya di katup expansi jg?
    Kode error di remot ac tidak terdeteksi

  • @putuagus999
    @putuagus999 2 года назад

    gmn cara kerja expansi valve itu?...trs posisi expansi valve di outdoor di mananya?

    • @arapaimagold8088
      @arapaimagold8088 Год назад

      Ngatur besaran sirkulasi freon. Lihat di bagian belakang kompre kalau Daikin. Ada benda bulat dengan magnet di dalam. Itu EEVnya.

    • @CakraLithium-jm7uy
      @CakraLithium-jm7uy 11 месяцев назад

      @@arapaimagold8088 kalau dibersihin atau diganti masih error berart pcbnya donk itu kan nyambung pcb yah,

  • @Tonysiswadi
    @Tonysiswadi 5 лет назад +2

    Kalo kapiler daikin 0,5 pk berapa mili ukuranya ya gan

    • @Tonysiswadi
      @Tonysiswadi 5 лет назад +1

      R32

    • @carleswijaya1818
      @carleswijaya1818 5 лет назад

      Bagaimana ac 1pk sharp tidak dingin,kompresor mati hidup,kipas jalan.ac dibeli sudah ada 5thn.thanks sebelumnya,bagaimana memperbaikinya.

  • @fikrihudagrab571
    @fikrihudagrab571 11 месяцев назад

    Bli ac invrter saya set d suhu 24 mau dingin, ketika suhu sudah tercapai kan dia kerja nya melambat, tapi setela itu gamau naik lagi kerja nyq. Kenapa ya? Kalo di mtiin kemudian nyalain kembali dia mau dngin lagi

    • @setia7723
      @setia7723 9 месяцев назад

      yah suhu ruangan sudah tercapai kalau naik lagi kompresor hidup lagi inverter itu harusnya di ruang tidur tidak disarankan di tempat ruang kelurga bisa tapi harus rapat ruangan agar kompresor tidak gas terus

    • @setia7723
      @setia7723 9 месяцев назад

      tekanan brp psi daikin bukan

  • @IskandarMarjo
    @IskandarMarjo Год назад

    Terlalu cepat vidio di tekanan freon bos.jd gsk jelas tekenannya.

  • @skychins107
    @skychins107 5 лет назад

    sore gan,saya mau nanya nih,ac daikin inverter 1pk saya kalau dihidupin pada suhu 24'c 1jam kemudian suhu dinginnya ilang,tp kalau stel suhu 16'c bisa sampe 3jam baru hilang suhu dinginnya,tp indoor tetap hidup,kalau dimatiin pake remote n hidupin balik tetap gak mau dingin,tp kalau matiin kontak listrik dan pasang balik lalu dihidupin baru bisa dingin kembali.tp masalah tetap 1jam kemudian suhu dingin ilang lagi.kenapa ya kira2 n apa kerusakannya.tq

    • @skychins107
      @skychins107 5 лет назад

      kelupaan,gak ada kode errornya,semua bagus stel sam00

    • @madearsa93
      @madearsa93  5 лет назад

      Sudah dapat di cleaning indoor dan outdoor

    • @madearsa93
      @madearsa93  5 лет назад

      Cek kode error pada saat ac error atau tidak dingin.

    • @nsixfamily6420
      @nsixfamily6420 3 года назад

      @@madearsa93
      Ini juga sama dengan AC saya daikin inverter 15 menit setelah jalan dinginya hilang

  • @dominicxavier7384
    @dominicxavier7384 4 года назад

    Bli.yang mau saya tanyakan?
    Itu expansi nya di copot.tidak pakei atau gimana yah🙏

    • @madearsa93
      @madearsa93  4 года назад

      Expansi di lepas di ganti dengan kapiler

  • @ipl5348
    @ipl5348 4 года назад

    Apa tandanya,dan bagaimana cara megetahui klo expansi palep xg rusak boss ku

    • @madearsa93
      @madearsa93  4 года назад

      Ampere naik, tekanan freon turun drastis

  • @wisnunaiu2777
    @wisnunaiu2777 5 лет назад

    ijin bertanya master. jika ac matot apa bisa cek kode erornya?

  • @TheRonggo
    @TheRonggo 5 лет назад

    kalau pakai ekpansi valve berarti gak pakai pipa capiler bos ?

  • @wijoyochannel
    @wijoyochannel 3 года назад

    pipa kapiler 0,54 ini diameter luar apa diameter dalam ya om?

  • @lingkanpradana
    @lingkanpradana 5 лет назад +1

    Pak itu klo diganti expansionya persis aslinya apa tidak ada djual?

    • @madearsa93
      @madearsa93  5 лет назад

      Ada yg jual di dealer nya harga lumayan

    • @lingkanpradana
      @lingkanpradana 5 лет назад +1

      @@madearsa93 boleh info dealer mna kebetulan saya tinggal dijimbaran, daikin mana, kisaran brp harganya?

    • @madearsa93
      @madearsa93  5 лет назад

      Service center daikin di buluh indah harga sekitar 800an komplit body exvansi sm elektronic expansi nya.

    • @lingkanpradana
      @lingkanpradana 5 лет назад +1

      @@madearsa93 oke makasih infonya pak sukses selalu

    • @madearsa93
      @madearsa93  5 лет назад

      @@lingkanpradana iya sm2, trimksih kmbli.

  • @as_siam1209
    @as_siam1209 3 года назад

    apakah gk pengaruh di modul nya kalo gk pakai electronic expansion

    • @madearsa93
      @madearsa93  3 года назад

      Gk ada masalah, aman

    • @as_siam1209
      @as_siam1209 3 года назад

      @@madearsa93 jadi apakah tidak muncul kode eror lagi setelah melepas komponen ter sebut.. dan di terapkan di ac non inverter misal panasonic dan merk ac lainya..

  • @satriasatria3894
    @satriasatria3894 3 года назад +1

    Kenapa gk di ganti baru ekspensinya aja bang

    • @madearsa93
      @madearsa93  3 года назад

      Iya benar ganti expansi lebih bagus, ini cara alternatif tanpa expansi memungkinkan ac masih bisa bekerja dengan baik.

    • @satriasatria3894
      @satriasatria3894 3 года назад

      Iya tapi lowat nya jadi hilang bang

  • @haurakhansa7875
    @haurakhansa7875 5 лет назад

    Luar biasa,,,,,berkah dan bermanfaat,,saya punya problem,Ac Daikin Tipe RKD 25GVM4, 1 pk,outdoor nyala,kompresor nyala,tapi sebentar dingin,sebentar hilang,,dinginnya cuman 1 menit,kemudian dingin lagi,,hilang lagi,dan seterusnya,apa penyebabnya ya mas? terima kasih,,,,,

  • @MuhammadZhafran-p2l
    @MuhammadZhafran-p2l Месяц назад

    Kalau untuk 1/2 pk ukuran dan panjangnya berapa?

  • @sbs_herry_prass6434
    @sbs_herry_prass6434 4 года назад

    Saya punya ac daikin inverter eroor u4 belum saya pasang unit outdoor nya saya nyalain indoor nya saja saya cek pakai remot u4

    • @sbs_herry_prass6434
      @sbs_herry_prass6434 4 года назад

      Kira2 apanya ya om,apakah tes ac inverter harus pakai freeon juga supaya gak muncuk eroor u4

    • @madearsa93
      @madearsa93  4 года назад +1

      @@sbs_herry_prass6434 instalasi kabek indoor ke outdoor harus terkoneksi.

    • @sbs_herry_prass6434
      @sbs_herry_prass6434 4 года назад

      Tapi tanpa freoon bisa gak gan?/ selang flexibelnya tidak si pasang?

    • @madearsa93
      @madearsa93  4 года назад +1

      @@sbs_herry_prass6434 pipa ac tidak terpasang, modul akan protek indikasi error pada saat nyala

    • @sbs_herry_prass6434
      @sbs_herry_prass6434 4 года назад

      Baik sangat bermanfaat dan terimakasih

  • @andirizaldi2427
    @andirizaldi2427 5 лет назад

    Apakah inverternya ttp berfungsi dgn normal?

  • @heruhasriadi6185
    @heruhasriadi6185 5 лет назад +2

    Kenapa gak ekspansinya aja yg diperbaiki, kan bisa di bersihkan pake r11

  • @anakrumahan4172
    @anakrumahan4172 4 года назад

    Bli made, kalau kerusakan U0 apa yang harus dicek ya? Saya baca di web artinya tersumbat atau expansion valve. Mohon bisa dibantu spesifiknya bli

    • @madearsa93
      @madearsa93  4 года назад

      U0 = kekurangan freon, ada kebocoran freon.

    • @anakrumahan4172
      @anakrumahan4172 4 года назад

      @@madearsa93 freon sudah dicek nggak bocor bli, tekanan malah di 120. Ampere stabil, tekanan stabil, ac nggak dingin kadang suka mati dan lampu indikator kedip

    • @madearsa93
      @madearsa93  4 года назад

      Ac daikin inverter ? Cek kode error sudah tepat ? Ac sudah dapat di cleaning indoor dan outdoor ?

    • @anakrumahan4172
      @anakrumahan4172 4 года назад

      @@madearsa93 baru indoor bli, kode sudah bener berkali2 cek dapetnya U0. Nanti akan coba saya turunin outdoornya biar keliatan dan saya flush. Kemarin karena freon mau habis, jadinya tukang ac ngisi posisi tabung freon dibalik, takut gram2nya masuk bli. Apakah bisa dari situ penyebabnya bli? Karena setelah diisi freonnya selang 4 hari kejadian seperti ini bli

    • @madearsa93
      @madearsa93  4 года назад

      Freon jenis apa

  • @bobx1473
    @bobx1473 4 года назад

    👍 grande

  • @mochanwar8044
    @mochanwar8044 Год назад

    Maaf
    Kenapa ga di vacum ya

  • @antowijaya1585
    @antowijaya1585 5 лет назад

    Bang klo panasonic inverter gak mau dingin knpa ya,,,freon 170 amper 1,4,,,itu ac nya 3/4 pk

  • @anaketv
    @anaketv 4 года назад

    Saya service ac
    Kata orang servicenya beli part dan harganya mahal
    Nah saya di kasih saran modif, jadi dari mesin yg diluar itu ada kabel sama sklar bell..
    Disuruh manual katanya biar ada freonnya, karna mesin yg diluar rusak otomatisnya jadi di buat manual gitu pake saklar
    Nah apa ya namanya alat nya itu yg mahal katanya..?

    • @madearsa93
      @madearsa93  4 года назад

      Maksudnya ? Pcb outdoor modul inverter.

    • @anaketv
      @anaketv 4 года назад

      @@madearsa93 mungkin itu ya

    • @anaketv
      @anaketv 4 года назад

      @@madearsa93 tapi gak paham saya begituan

    • @anaketv
      @anaketv 4 года назад

      Jadi selama ini saya ya kalo gak dingin saya tekan sklar bell itu, langsung dingin.. Nanti gak dingin lagi saya tekan lagi dingin lagi

    • @madearsa93
      @madearsa93  4 года назад

      @@anaketv ini ac biasa bukan inverter ?
      Munkin maksudnya yg rusak modul pcb indoor ac jadi gak bisa auto kontak power ke power ke outdoor, jadi di ganti manual hidupin dengan saklar.

  • @whoiam1070
    @whoiam1070 5 лет назад

    ukuran kapiler dan panjang buat 2pk inverter brapa mas

  • @rijalengineering5188
    @rijalengineering5188 5 лет назад

    Maaf bli kalo daikin inverter eror u2, bagian mana yg harus di perbaiki

    • @rijalengineering5188
      @rijalengineering5188 5 лет назад

      Kata service center daikin harus ganti modul dgn harga 2,5 juta.
      Konsumen saya gak mau, mohon bantuannya

    • @raihanraqqilla3186
      @raihanraqqilla3186 4 года назад

      @@rijalengineering5188 ganti kapasitor vdc outdoor

    • @rijalengineering5188
      @rijalengineering5188 4 года назад

      @@raihanraqqilla3186 mohon maaf bentuk nya seperti apa ya?

    • @raihanraqqilla3186
      @raihanraqqilla3186 4 года назад

      @@rijalengineering5188 bongkar pcb outdoor nya bawa ke tukang servis elektronik nati di tujukin rupa kapasitor VDC

  • @iqbalteknik3589
    @iqbalteknik3589 5 лет назад

    Maaf minta solusi saya bnerin AC daikin sama persis cuma 1/2pk gk dingin sy cek freon 200psi amper 0.8 itu knapa y mas

    • @iqbalteknik3589
      @iqbalteknik3589 5 лет назад

      @@madearsa93 tapi hidup posisinya mas sya sampai gonta ganti tang amper bingung gmn caranya mas

    • @iqbalteknik3589
      @iqbalteknik3589 5 лет назад

      @@madearsa93 tang amper posisi di 1 di tespen nyala.saya cek kode eror pake remot gk ad eror sampai terakhir ke 00 bunyi panjang.saya isi freon 80 pipa tekan dingin sebentar tekanan manifol naik ke 200 psi amper trun ke 0.8 trus gk dingin sama sekali.

    • @iqbalteknik3589
      @iqbalteknik3589 5 лет назад

      @@madearsa93 posisi sting remot di temperatur terendah 18 derajat.

    • @iqbalteknik3589
      @iqbalteknik3589 5 лет назад

      @@madearsa93 stat awal amper 1.2 mas itu ac daikin baru 6 bulan masih baru sy blom buka elektronik valvenya.ok sy cba mas mksh saranya

    • @iqbalteknik3589
      @iqbalteknik3589 5 лет назад

      @@madearsa93 freon R32 mas..star awal kipas outdor kencang lama amper trun 0.8 tekanan 200psi kipas melambat apa itu normal mas

  • @harvesttechhd1957
    @harvesttechhd1957 5 лет назад

    Wah itu eev nya dikemanain?

  • @darmawiyansyah78syah91
    @darmawiyansyah78syah91 5 лет назад

    Mas tlg impo nya kah AC Daikin inverter saya audor nya nyala sbntr trus mati..ap ya mas..

  • @ubn4046
    @ubn4046 4 года назад

    Bahkan pipa ac nya saya ganti baru 5m & sblm di isi freon nya saya vaccum dulu tapi yg saya bingung setelah 3 hari ac nya mati lagi 🤔