Sir, aap ka bahut shukriya itni informative videos banane ke liye. Interview me ek question pucha gaya mujhse ki "3 Way Valve ko return ke bajay supply line me laga sakte hai ya nahi". Please iska answer de aap.
DRV/Balancing/2-way/3-way vales is used for control chilled water flow as per design requirements which is installed return pipeline. It is normally installed on return because of the following reasons: 1. ASHRAE Recommendations. 2. The coil of the unit should be flooded in case the valve is closed. 3. With a control valve on the return side, the water is at a higher pressure through the coil, reducing off gas, thereby lowering dissolved oxygen content. Lower dissolved oxygen extends equipment life by minimizing the air entrapment. 4. In coil return line, after AHU/FCU install two way or three way valve, afterward install DRV due to above reasons.
And also in 2-way valve system differential pressure transmission is required. In least points sense the proper temperature, and flow meter also required to modulate the flow which is interfaced with the bms system
your videos are very helpful sir, im working as a modeller, please make videos on quality control topic on navisworks, how to detect clashes and report them to the designers who are working on revit software., naviswork software pe ek playlist bana dijiye
Assalam alaikum sir,,,,,, thank your for your all videos for sharing knowledge. I have 1 doubt, that 2 way valve is used in return line for AHU or FCU . But for chilled water HI-Wall unit which is wall mounted like split AC why we connect 2 way valve in supply line?? Please answer
Assalam O AllikUm Tanveer Sahib...we are building a 5 floor hospital with cooling load of approximately 500000 cfm for the whole building (average of 100,000 cfm per floor) We r having 4 chillers (3 functional + 1 standby) with a cooling load of 700 TR per chiller. We have 5 VFD based condensed water chillers each with a capacity of 1700 GPM at 185 feet head and 5 VFD based chilled water pumps with a capacity of 2100 gpm at 125 feet head. We have 2 cooling towers with 4 cells and 4000 gpm for each cooling tower. Moreover, we planning to make 2 out of 5 floors operational at this time only and energizing 1 chiller at this time. My question is that for only energizing 1 chiller (700 TR) only, will it be sufficient for cooling 2 out of 5 floors and if yes, gthen how many VFD based HVAC pumps (out of 5 each for chilled and condensed water pump) be required to run for this partial energization? Regards
Assalamualaikum,,, taveer sir, mujhe yeh jankari lena hai Aapse ki, mujhe HVAC field me career bnana hai to kiya mujhe AutoCAD janna zaruri hai, kiyoki mai Mechanical engineer hu, lekin mujhe autocad nahi Aata hai, to kiya mai pahile AutoCAD sikh lu uske baad HVAC-MEP kr ke job, please reply me
HVAC maintainance department mein vacancy batana. HVAC engineer or supervisor k level ki. ...bcoz I have iti in refrigeration and air conditioning and diploma in mechenical both i have done.
All tricks are useless without knowledge. First improve your skill knowledge, specially basics HVAC then mention points in your CV where your grip is strong. Mostly interviewers ask questions from your CV.
They are normally installed on return because of the following reasons: 1. ASHRAE Recommendations. 2. The coil of the unit should be flooded in case the valve is closed. 3. With a control valve on the return side, the water is at a higher pressure through the coil, reducing off gas, thereby lowering dissolved oxygen content. Lower dissolved oxygen extends equipment life by minimizing the air entrapment. 4. In coil return line, after AHU/FCU install two way or three way valve, afterward install DRV due to above reasons.
DRV/2-way/3-way vales is used for control chilled water flow as per design requirements which is installed return pipeline. It is normally installed on return because of the following reasons: 1. ASHRAE Recommendations. 2. The coil of the unit should be flooded in case the valve is closed. 3. With a control valve on the return side, the water is at a higher pressure through the coil, reducing off gas, thereby lowering dissolved oxygen content. Lower dissolved oxygen extends equipment life by minimizing the air entrapment. 4. In coil return line, after AHU/FCU install two way or three way valve, afterward install DRV due to above reasons.
It is built-in in valves. Actually there are three types: 1. On/Off valve as per temperature demand 2. Proportional valve which automatically % open open or close as per demand i.e. may be 10%, 15%, 20%, 25%.....100% 3. Percentage valve which open and close fixed %wise such like 0%, 50% & 100%
Part-2 video link: ruclips.net/video/-lyDKsepLHg/видео.html
Sir, aap ka bahut shukriya itni informative videos banane ke liye. Interview me ek question pucha gaya mujhse ki "3 Way Valve ko return ke bajay supply line me laga sakte hai ya nahi".
Please iska answer de aap.
DRV/Balancing/2-way/3-way vales is used for control chilled water flow as per design requirements which is installed return pipeline.
It is normally installed on return because of the following reasons:
1. ASHRAE Recommendations.
2. The coil of the unit should be flooded in case the valve is closed.
3. With a control valve on the return side, the water is at a higher pressure through the coil, reducing off gas, thereby lowering dissolved oxygen content. Lower dissolved oxygen extends equipment life by minimizing the air entrapment.
4. In coil return line, after AHU/FCU install two way or three way valve, afterward install DRV due to above reasons.
Salute you our Hero Tanveer Ahmad
So nice of you
And also in 2-way valve system differential pressure transmission is required. In least points sense the proper temperature, and flow meter also required to modulate the flow which is interfaced with the bms system
Yes agreed
Thanks for making useful video...Keep it up.May Allah increase you in knowledge.
Thanks
👍
Thanks
Bhut khoob .bhut acchi trhaa se explain krte hain aap
Thank you
your videos are very helpful sir, im working as a modeller, please make videos on quality control topic on navisworks, how to detect clashes and report them to the designers who are working on revit software., naviswork software pe
ek playlist bana dijiye
Thanks
In my interview ,the question asked was.. why there are pressure gauges on pump suction and discharge and it's importance?
I will inform in next video, Insha'Allah
Very good information.
Thank you
walikum salam sir ,very great knowledge provide, and hard work. but i personal request you some videos make in sindhi language for HVAC filed.
سنڌي ۾ ويڊيو ڏسڻ وارا گھٽ آھن
intresting video sir
Thanks
your videos are highly helpful... keep it up
Thanks
Very good and thanks so much
Welcome
Sir aaj kal Troubleshooting questions zyda pochaa jata h toh aap iss pe video bnaye naa....
Mohammad Aqif Rizwan from India🇮🇳
Insha'Allah
Well done Sir ,kindly HVAC design thumb rules pa video bnaen buildings and industries ka lia .
Ok noted
Tanweer Sab you excellent explain , Now i Become HVAC Engineer. hahaha
Thanks
Assalam alaikum sir,,,,,, thank your for your all videos for sharing knowledge.
I have 1 doubt, that 2 way valve is used in return line for AHU or FCU . But for chilled water HI-Wall unit which is wall mounted like split AC why we connect 2 way valve in supply line?? Please answer
You can install in supply line but if you install in return line the it will be more beneficial
Assalam O AllikUm Tanveer Sahib...we are building a 5 floor hospital with cooling load of approximately 500000 cfm for the whole building (average of 100,000 cfm per floor) We r having 4 chillers (3 functional + 1 standby) with a cooling load of 700 TR per chiller. We have 5 VFD based condensed water chillers each with a capacity of 1700 GPM at 185 feet head and 5 VFD based chilled water pumps with a capacity of 2100 gpm at 125 feet head. We have 2 cooling towers with 4 cells and 4000 gpm for each cooling tower. Moreover, we planning to make 2 out of 5 floors operational at this time only and energizing 1 chiller at this time.
My question is that for only energizing 1 chiller (700 TR) only, will it be sufficient for cooling 2 out of 5 floors and if yes, gthen how many VFD based HVAC pumps (out of 5 each for chilled and condensed water pump) be required to run for this partial energization? Regards
W.Salam,
Contact with design consultant
excellent bro
very nice explantation
Thanks
Sir, HVAC ka wire connection ka bare main bhi video bnaye
What do you want to know about wire connections ⁉️
Very very informative video sir...
Thanks a lot...
And ed Mubarak
Thank you
Chiller ka purging system pe video banaye?
Ok noted
Great.. Sir
Thanks
Hvac system mein chilled water line aur condenser water line mein kaun kaun se valve lage hote hain sequence mein ?
Watch my videos how to read HVAC drawing of chilled and condenser pipelines
Very good
Thank you
Asslm alkm...tanveer saab....how to make budgeting and estimation of project
W.Salam
Mashaallah
Thanks
Assalamualaikum sir please make a vedio on interview questions vedio in which we can interview the person having more than 5 years of experience
These videos will useful for junior as well as senior Engineers. Insha'Allah
Good 👍
Thank you
Zabardast ada from Mehran eccentric reducer for air pocket missing
Thanks for highlighting. You are right
Assalamualaikum,,, taveer sir, mujhe yeh jankari lena hai Aapse ki, mujhe HVAC field me career bnana hai to kiya mujhe AutoCAD janna zaruri hai, kiyoki mai Mechanical engineer hu, lekin mujhe autocad nahi Aata hai, to kiya mai pahile AutoCAD sikh lu uske baad HVAC-MEP kr ke job, please reply me
W.Salam,
You should know AutoCAD
❤ wow sir thanks
Welcome
HVAC maintainance department mein vacancy batana.
HVAC engineer or supervisor k level ki.
...bcoz I have iti in refrigeration and air conditioning and diploma in mechenical both i have done.
Ok
Thank you so much sir
Welcome
Sir hamko interview dena hai HVAC ke regarding to ap Aisa trick bataye ki interview clear ho gayee
All tricks are useless without knowledge. First improve your skill knowledge, specially basics HVAC then mention points in your CV where your grip is strong. Mostly interviewers ask questions from your CV.
assalamualikum. iam requesting to upload a video for Design of Hospital project.
Regards.
W.Salam
Nice Video!
I have a query? Why are control valves(3-way or 2-way) on the return side?
They are normally installed on return because of the following reasons:
1. ASHRAE Recommendations.
2. The coil of the unit should be flooded in case the valve is closed.
3. With a control valve on the return side, the water is at a higher pressure through the coil, reducing off gas, thereby lowering dissolved oxygen content. Lower dissolved oxygen extends equipment life by minimizing the air entrapment.
4. In coil return line, after AHU/FCU install two way or three way valve, afterward install DRV due to above reasons.
@@TanweerAhmed Thank you for such a detailed reply!
Welcome
Thank you sir...
Welcome
The same question asked in my interview but he asked me like that why we used 3-way valve in FAHU instead of 2-way if 2 way we used it's also workable
Good
But where is constand speed and variable speed needed? I mean which kind of building
It depends on system design
Why we used 2-way valve in return line of Ahu/Fcu
Sir Can u describe this.
DRV/2-way/3-way vales is used for control chilled water flow as per design requirements which is installed return pipeline.
It is normally installed on return because of the following reasons:
1. ASHRAE Recommendations.
2. The coil of the unit should be flooded in case the valve is closed.
3. With a control valve on the return side, the water is at a higher pressure through the coil, reducing off gas, thereby lowering dissolved oxygen content. Lower dissolved oxygen extends equipment life by minimizing the air entrapment.
4. In coil return line, after AHU/FCU install two way or three way valve, afterward install DRV due to above reasons.
@@TanweerAhmed thank you sir.
Plz upload next part
Welcome... Insha'Allah soon will upload
Bhai jaan mughe bhi hvac ka channel banana hai category kaun sa select karein please bataiye 🙏😘👍🇮🇳
Science and technology
👍
Thanks
Thanks you sir 🥀
Welcome
Sir vrf py video banaye
Ok noted
hvac legends or symbol in detail btayen plz
My videos are available on legends and symbols
Thanks
Welcome
sir HVAC / MECHANICAL SUPERVISOR KE KOI VIDEO SHARE KARE
Ok noted
Fire pump ka flow test kaise karte hai pls bataiye
Fire pump flow measure through flow meter installed in pump room. Some my videos are available and further will prepare
HVAC vs MEP pe ek video banaye
Ok noted
@@TanweerAhmed sir dono mai best kon hai
Or dono Mai se jiya da scope kis ka h India Mai or gulf mai
MEP scope is more and HVAC is part of MEP
@@TanweerAhmed thankyou sir
Could you put translation in English and thank you sir for your efforts
Ok noted, I will subtitles
You have not showed eccentric reducer in the suction line , this is most important to provide eccentric reducer
Thanks for highlighting and sharing your positive response
In my interview also asked eccentric reducer on suction of pump and flat side to or bottom?
There are different conditions. Insha'Allah will prepare video on this topic
how we set the percentage in mixing valve
It is built-in in valves. Actually there are three types:
1. On/Off valve as per temperature demand
2. Proportional valve which automatically % open open or close as per demand i.e. may be 10%, 15%, 20%, 25%.....100%
3. Percentage valve which open and close fixed %wise such like 0%, 50% & 100%
what is double regulating valve?
Watch my video on Double Regulating Valve
Assalamualaikum sir
Sar compensation chain ka kya use Hota Hai
W.salam,
Where is installed compensation chain?
Hello sir, please translate in English
Ok noted
Hi
جی
Plasr
⁉️
Tanweer Bhai aap APNA Whatsapp number send kar sakte hain...
You can ask here, I will must reply or joint my Telegram group "HVAC|MEP Engineering"