How to Setup an Arterial Line Transducer

Поделиться
HTML-код
  • Опубликовано: 3 май 2012
  • 5 things needed when setting up an A-line

Комментарии • 51

  • @dbell582
    @dbell582 2 года назад +1

    Getting the correct orientation of the transducer holder has always given me trouble. Thanks for the info. Hopefully I can remember it next time. We just don’t do a lot of art lines.

  • @emilyvoss4192
    @emilyvoss4192 5 лет назад

    I am looking for the Trancducer mount and cant find one. where did you get yours or do you have a online store you can lead me to?

  • @restinrip7370
    @restinrip7370 4 года назад +3

    I love her eye

  • @aqibali2599
    @aqibali2599 Год назад

    is there any leak tester to meet the need of 580 psi pressure for PMO/pressure monitoring line or arterial lines

  • @sweir123
    @sweir123 8 лет назад +68

    Don't forget to squeeze the air out of the saline bag first!

    • @18652512
      @18652512 5 лет назад

      @@TheGreatWall002 There is no safety device preventing air embolism when your bag gets empty and it's more convenient to change the bag if there is no air in the line. It's not required to remove the air from the bag, but I do it as an extra level of safety and convenience.

    • @18652512
      @18652512 5 лет назад +1

      @@TheGreatWall002 I am a CVICU nurse and patients with a-lines sometimes live past their surgery (maybe not your patients). That a-line may be there a week or more with frequent blood draws, it's very common to have to change the saline bag out due to flushing after blood draws. Nobody mentioned giving iv fluids to the patient through the a-line. ***This is very basic, and anyone working in the OR, and managing a patient knows this (or should know this).

    • @chrisguapo69
      @chrisguapo69 5 лет назад +1

      You have to burp the bag to get all the air out. Its common in the ICU for the bag to run out. The pressure bag runs between 3-5ml/hr so that equates to between 64-100ml alone per day. Now factor in checking dynamic response, flushing between lab draws, zeroing the system and that 500ml bag is gone in 2-3 days.
      When you stated “I’m an anesthesiologist” I knew you weren’t aware of what happens on the floor. Don’t sweat it though, nobody’s perfect.

    • @af3327
      @af3327 3 года назад

      Yea I didn't see them De air the bag before pressurizing the bag the trasducer works with the pressure bag having NO air then add the 300mmhg if u do before that u are not in 300mmhg

  • @zacharythompson2342
    @zacharythompson2342 Год назад +1

    What about replacing the fenestrated caps?

  • @sewflower1
    @sewflower1 7 лет назад +35

    I would suggest not pressurizing the bag until after the line is primed, otherwise it creates micro bubbles in the tubing because of turbulence. Also, it is easier to have the transducer etc in their holder so the tubing isn't flopping around and you can hold the end upwards since air bubbles rise upwards.

    • @PainH8er
      @PainH8er  7 лет назад +2

      Thanks for the suggestion!

    • @thedividexxi
      @thedividexxi 6 лет назад +2

      Loretta Gilbert my mentor said exactly the same to me today.

    • @AneasthesiaTech
      @AneasthesiaTech 4 года назад

      ruclips.net/channel/UCFLdcqGAHEo5VRVCv96l8Ag?view_as=subscriber?sub_confirmation=1

    • @david2006ose1
      @david2006ose1 3 года назад +2

      I agree. Prime before pressuring

  • @NA-fz7gp
    @NA-fz7gp 4 года назад

    Very nice

  • @rajeshkumarjonwal3570
    @rajeshkumarjonwal3570 2 года назад

    Good producer

  • @PainH8er
    @PainH8er  11 лет назад

    Yes

  • @warunakumara7671
    @warunakumara7671 3 года назад +1

    sir you must first purge the air line then then the patient connecting tubing isnt it, i also got another question to ask sir why do we use pressure infusion bag and pressure it to 250 or 300 why is that

    • @sanasingh3779
      @sanasingh3779 2 года назад

      @Waruna . The saline bag is pressurised because if it not your arterial BP will be more than the pressure in the tubing of the bag and you will end up getting back flow of blood into the tube. I think that is the answer🤔

  • @BoredT-Rex
    @BoredT-Rex 3 года назад

    does the transducer have to be at a certain height or no?

    • @PainH8er
      @PainH8er  3 года назад

      After it is zeroed, it should be leveled to patient's heart (the phlebostatic axis)

  • @Hamada_Abdelhameed
    @Hamada_Abdelhameed 6 лет назад +2

    Heparnization?

  • @MrSoham2010
    @MrSoham2010 3 года назад +1

    Hi if anyone can let me know -why tubing going to the patient needs to be upwards in the transducer set ? any reasons for it

    • @PainH8er
      @PainH8er  3 года назад

      Hello. Thanks for the question. I'm not sure I'm understanding. Are you asking why the transducer is not right next to where the tubing connects to the arterial line catheter?

    • @TheLifeOfNurse
      @TheLifeOfNurse 3 года назад

      @@PainH8er I think he is asking why you position the transducer on the white mount with the tubing going toward the patient upwards. @2:20

    • @julietheis4641
      @julietheis4641 3 года назад

      i'm interested in this too

    • @julietheis4641
      @julietheis4641 3 года назад

      @@TheLifeOfNurse yes that was the question

    • @sohambhattacharya8493
      @sohambhattacharya8493 3 года назад

      @@PainH8er I want to know why the tubing going to the patient should be placed upwards @ 2.20-230. as stated by @saline and @julie

  • @n9pq54
    @n9pq54 Год назад +1

    How much heparin should we put in 500N/S ?

  • @athabaskan
    @athabaskan 6 лет назад +3

    I read that you have to have the pressure bag 2 feet above the patient?

    • @TheGreatWall002
      @TheGreatWall002 5 лет назад

      it does not matter. The pressurized bag can be below the patient or at the same level. What matters is the transducer.

  • @Mcclot1993
    @Mcclot1993 11 лет назад +2

    I have a question are Registered Nurses allowed to set up arterial line transducer.

  • @IronReef77
    @IronReef77 7 лет назад +6

    Thanks for the video, she's Beautiful by the way. Maybe I should apply to where she works hahaha

    • @terrellgrant2758
      @terrellgrant2758 2 года назад

      I was really looking at her like... are we just going to ignore the fact that shes fine af.

  • @doctorfrater
    @doctorfrater 7 лет назад +8

    She is beautiful love your eyes.

  • @HariPrasad-xq4pf
    @HariPrasad-xq4pf Год назад

    Y need to put pressure 300

    • @PainH8er
      @PainH8er  Год назад

      You have to pressurize the system to be able to flush it. Remember that this will be hooked up to an ARTERY. The pressure inside an artery is much higher than the pressure inside a vein. Unless the pressure in the system is higher than the pressure inside the artery, blood from the artery will back up into the tubing.

  • @ventilator98
    @ventilator98 11 лет назад

    I sent you a message on some requests I would like to see on a video of the Aestiva 5. I BEG OF YOU, Please view the message.

  • @elzilenevieira918
    @elzilenevieira918 4 года назад +2

    Podia se em português

  • @Case-qy4xy
    @Case-qy4xy 3 года назад

    You didn’t show how to zero it.

    • @icejunki
      @icejunki 10 месяцев назад

      An important step we all expected to be included.

  • @david2006ose1
    @david2006ose1 3 года назад +2

    Is the black bucket sterile?? Because if not you guys would be causing septicemia otherwise! Asepsis principles are crucial. No thanks don't set it up for me.

    • @PainH8er
      @PainH8er  3 года назад +11

      Bro. Totally with you. I didn't specify, but we were just in a sim lab jacking around with old unsterile equipment. Not used on a patient. Have a good day.

    • @jasongriffin9143
      @jasongriffin9143 Год назад

      Example I’m guessing