RsLogix 500 Counters - CTU and CTD Count Up and Count Down Counter

Поделиться
HTML-код
  • Опубликовано: 21 янв 2025

Комментарии • 32

  • @blatogh1277
    @blatogh1277 3 года назад +5

    I love these videos. It is really helpful for my senior design project.

  • @shivanshsingh7189
    @shivanshsingh7189 5 лет назад +2

    watched tons of videos but this one was most helpful ......cheers tim

  • @garymatthews6309
    @garymatthews6309 Год назад +1

    Thank you, another great video

  • @oaingenieria6641
    @oaingenieria6641 2 года назад +1

    Tim, you are my hero!!

  • @HolyPiyush
    @HolyPiyush 2 года назад +2

    Great video....keep growing ❤️🇮🇳

  • @sudhandiramanisundaram4909
    @sudhandiramanisundaram4909 3 года назад +1

    Good Videos. Thanks lot Mr.Tim,

  • @urgayl0l
    @urgayl0l 3 года назад +1

    do you have the later video on the overflow bit? I couldnt find it in your videos

    • @TimWilborne
      @TimWilborne  3 года назад +2

      Do you mean the math overflow or the counter overflow?

    • @urgayl0l
      @urgayl0l 3 года назад +1

      @@TimWilborne the counter overflow

    • @TimWilborne
      @TimWilborne  3 года назад +2

      @@urgayl0l No, I don't think I did. It will be set when the counter ACC goes from 32,767 to -32,768.

    • @urgayl0l
      @urgayl0l 3 года назад +1

      @@TimWilborne thank you so much! Your videos are great!

    • @TimWilborne
      @TimWilborne  3 года назад +1

      You are welcome!

  • @nakiapringley5391
    @nakiapringley5391 3 года назад +1

    Great video 💯💯💯💯💯

  • @lwta
    @lwta 4 года назад +1

    dear sir, I need your help about slc 500 plc program

    • @TimWilborne
      @TimWilborne  4 года назад

      What is your question?

    • @lwta
      @lwta 4 года назад

      @@TimWilborne I have two question, 1. how can create 10 digit counter. and 2. the count value should not reset after power off slc 500. (2324567999 after again power on 2324567999)

  • @tonyrange1874
    @tonyrange1874 3 года назад +1

    How would you add a reset to a CTD?

    • @TimWilborne
      @TimWilborne  3 года назад +2

      Use the RES instruction in a separate rung.

    • @tonyrange1874
      @tonyrange1874 3 года назад +1

      @@TimWilborne is it possible to do a reset with a CTD timer without a CTU one? My problem was it automatically resetting because it uses “-x, it’s constantly resetting itself.

    • @TimWilborne
      @TimWilborne  3 года назад

      @@tonyrange1874 A counter's range is 0-32,767. I won't go negative. You need to make you own using an ONS instruction and a SUB instruction in place of the counter.

  • @Gersberms
    @Gersberms 3 года назад +1

    So it only counts once, on going from a false to a true rung. Not at all like a timer!

  • @617ashishthorat4
    @617ashishthorat4 5 лет назад +1

    U could have made preset value in CTD counter 0,and acc value 10....then it would have worked counting down....RIGHT??

    • @TimWilborne
      @TimWilborne  5 лет назад

      Hi Ashish. I'm not understanding your question. Are you talking about around 11:40? The CTD counter worked. It will decrement the accumulated each time the CTD is enabled until it reaches 0.

  • @alearnerforsafety3692
    @alearnerforsafety3692 4 года назад +2

    We can reset the Counter by using the (RES) instruction so the the Count Up over flow bit (OV) and the Count down under flow bit (UN) will reset also.

    • @TimWilborne
      @TimWilborne  4 года назад +2

      Yes all values except the PRE will be set to zero.