How to become a BMS engineer part 79 (BMS Interview Questions)

Поделиться
HTML-код
  • Опубликовано: 1 фев 2025

Комментарии • 47

  • @בוריסשולקוב
    @בוריסשולקוב Год назад +1

    תודה!

  • @SantosJrCapellan-BMS
    @SantosJrCapellan-BMS  4 года назад +6

    shout out to my subscriber who asked for this

  • @bleesaqeebibneHussain
    @bleesaqeebibneHussain 29 дней назад +1

    Thank you soo much sir for ur valuable information 😍😇

  • @boysadda
    @boysadda 3 года назад +4

    Sir you are true educator and a nice person also...

  • @SantosJrCapellan-BMS
    @SantosJrCapellan-BMS  2 года назад +1

    thank you for watching this video tutorials, appreciate your viewing, guys you can help me post more video tutorials and acquire more equipment for tutorial purposes by purchasing super thanks

  • @SantosJrCapellan-BMS
    @SantosJrCapellan-BMS  4 года назад +3

    differential pressure sensor used also for staircase and lift lobby pressurization system

  • @waqarkhawar6745
    @waqarkhawar6745 5 месяцев назад +2

    Hi there,where can i learn to Integrate Low voltage systems like CCTV Fire Alarms to BMS?

    • @SantosJrCapellan-BMS
      @SantosJrCapellan-BMS  5 месяцев назад

      you join the channel then we might schedule a tutorial in software integration

    • @waqarkhawar6745
      @waqarkhawar6745 5 месяцев назад

      @@SantosJrCapellan-BMSthanks for Your consideration i will surely look to seek something from you

  • @ELV_Engineering
    @ELV_Engineering 2 года назад +2

    Wondeful explaination

  • @ELV_Engineering
    @ELV_Engineering 2 года назад +3

    Dear sir, please make one video on vav progarmming

    • @SantosJrCapellan-BMS
      @SantosJrCapellan-BMS  2 года назад

      in my previous projects handled all of our VAVs are using pre-programmed controllers, meaning when the VAV units came to project a controller was also supplied which is already programmed for VAV application. all we need to do is configure and change some parameters.

    • @SantosJrCapellan-BMS
      @SantosJrCapellan-BMS  2 года назад +1

      in you case if only VAV box was supplied then you need to program the controller that will control and monitor the operation of it. you can use same logic as an AHU except I guess there will be no chilled water valve control only damper control will be there. Check first what are the sensors installed in the VAV boxes like dampers actuator (modulating, three point control), temperature sensor, pressure sensor, etc
      then based on this you can write your own control logic program

  • @sachinkp4504
    @sachinkp4504 4 года назад +1

    Great sir...

  • @michaelabesamis7484
    @michaelabesamis7484 4 года назад +3

    Hi Sir! Im a BMS operator & Engr.

  • @ecrodinon424
    @ecrodinon424 4 года назад

    Sir thank you po. Very helpful po talaga ito.

  • @mussiemisghina
    @mussiemisghina Год назад +1

    How long you been doing BMS Engineer? I like your tutorial.

    • @SantosJrCapellan-BMS
      @SantosJrCapellan-BMS  Год назад

      it's been two years now you can JOIN the channel for detailed tutorials

  • @CommercialGasEngineerVideos
    @CommercialGasEngineerVideos 2 года назад +1

    Very good

  • @mohammedabdullahkhan4264
    @mohammedabdullahkhan4264 3 года назад

    Can you explain for which device, which protocol, we have to use and each protocol how many devices. We can connect

  • @nazimmalik9066
    @nazimmalik9066 2 года назад +1

    if building fire alarm coming then what happen our ahu can u expalain sir my question how to our ahu input output work in ddc and our AHU off somke alaram plzz answer sir

    • @SantosJrCapellan-BMS
      @SantosJrCapellan-BMS  2 года назад +3

      the BMS engineer's control logic program for an AHU includes fire alarm status coming from Main Fire Alarm Panel, if the AHU should not run when there is fire alarm then it will automatically stop based on the DDC control logic program, at the same time the fire alarm people will install a relay module in each AHU's control panel that will be controlled by the FACP program

    • @SantosJrCapellan-BMS
      @SantosJrCapellan-BMS  2 года назад +2

      the FACP program will activate the relay module that will open the Normally Close Contact (NC) where the control voltage for this AHU is connected thus de-energizing the contactor of the AHU's Fan motor.

    • @nazimmalik9066
      @nazimmalik9066 2 года назад

      Thanks for reply sir great answer

  • @anassatti9960
    @anassatti9960 2 года назад +1

    Sir please explain the difference between Humidity & Relative Humidity.

    • @SantosJrCapellan-BMS
      @SantosJrCapellan-BMS  2 года назад +1

      humidity is the concentration of moisture in the air that is why we have a term humid (meaning the air has more moisture on it, like in the middle east or in Qatar in the month of June to August the air is so humid. While relative humidity is the ratio of the amount of water vapor actually present in the air to the greatest amount possible at the same temperature . (taken from google credit belongs to them). There are so many good explanation of relative humidity in the internet.

  • @sahilkhateeb1832
    @sahilkhateeb1832 3 года назад +1

    Great, sir where can i search for bms jobs pl let me knw sir

  • @doman3628
    @doman3628 Год назад

    Thank you :)

  • @rishad_automation
    @rishad_automation 3 года назад +1

    Can I work as a BMS engineer or BMS commissioning engineer. Because I have done engineering in computer science. But I wanted to go as a BMS engineer. Present time I am working as a BMS operator. Please 🙏 reply

    • @SantosJrCapellan-BMS
      @SantosJrCapellan-BMS  3 года назад +1

      yes you can, as a BMS operator you are aware of what is being controlled and monitored in Building Automation. You know how these HVAC equipment works then it will be easy for you to write the control logic program let say for air handling unit (AHU). Continue supporting my channel keep watching my tutorials which I guess it is almost complete for those who wishes to join the field of BMS.

  • @rjsing2836
    @rjsing2836 2 года назад +1

    Sir i m persuing mechanical engineering
    Can i go in this field?

    • @SantosJrCapellan-BMS
      @SantosJrCapellan-BMS  2 года назад

      yes, I am a graduate of Mechanical engineering, you have the advantage if you are a ME gradaute because most of the controlled and monitored equipment in BMS or BAS is HVAC

  • @vaughnbenethpalompon6102
    @vaughnbenethpalompon6102 4 года назад

    Present po

  • @kaleemhashmi5948
    @kaleemhashmi5948 2 года назад

    Hello Can u send me this documents please