S-Meter Radio Receiver Accuracy Test

Поделиться
HTML-код
  • Опубликовано: 30 окт 2024

Комментарии • 12

  • @thomasmoore8142
    @thomasmoore8142 Год назад

    Nice job...

  • @SpinStar1956
    @SpinStar1956 6 месяцев назад

    I noticed you generator says 75 Ohms?

    • @rfburns3472
      @rfburns3472  6 месяцев назад

      That was a good catch! The generator was set for 75 ohms since my attenuator was 75 ohms which may have scewed the results a bit.

    • @SpinStar1956
      @SpinStar1956 6 месяцев назад

      @@rfburns3472 If you get a chance, could you just do say a single ‘S-9’ measurement; I’m really interested to see what the difference might be? Tnx & 73…

    • @rfburns3472
      @rfburns3472  6 месяцев назад

      @@SpinStar1956 There is a S9 measurement in the video. Can you please clarify your request?

    • @SpinStar1956
      @SpinStar1956 6 месяцев назад

      @@rfburns3472 well your generator was set to 75 Ohms and the Swan is 50 Ohms, then I would think there would be an error.
      I was thinking that you could make a single-point S-9 measurement with the generator properly set to 50 Ohms to gauge the amount of error when it was inadvertently set to 75 Ohms.

    • @rfburns3472
      @rfburns3472  6 месяцев назад

      @@SpinStar1956 Gottcha. If I get time, I will recheck it this weekend. I too am interested in what the difference might be.