how to check tappet clearance of Generator

Поделиться
HTML-код
  • Опубликовано: 4 окт 2024

Комментарии • 73

  • @jong6478
    @jong6478 2 года назад +2

    thank you for making vedeo which is intended for pinoy engineers only..

  • @mrbesinadventures1909
    @mrbesinadventures1909 2 года назад +1

    Thanks sa videos mo boss maayos ang explaination mo.

  • @jestonybadilla8674
    @jestonybadilla8674 4 месяца назад

    Idol ang galing mo,,

  • @kurazhnica
    @kurazhnica 2 года назад +1

    Good video👍👍👍show some more videos on the same topic!

  • @patongko1532
    @patongko1532 Год назад +1

    Does the bridge valve need to be cleared? and what is the clearance size? Thank You

  • @RC-807
    @RC-807 5 месяцев назад

    sir ask ko lng sir ano po reason bakit mas malaki ung clearance ng exh valve kesa sa inlet valve ? salamat sir more power

  • @marvinpuno204
    @marvinpuno204 2 года назад +1

    tight mo ng konti adjustment mo sir s feeler gauge ung tipong lumalaban ng konti mejo maluwag p ung adjust mo, advice lng. base on.my expi.

  • @jigarpanuncial2028
    @jigarpanuncial2028 Год назад +1

    Galing mo sir...

    • @makinistangseaman8665
      @makinistangseaman8665  Год назад +1

      Thank you brother God bless keep safe please kindly share the video pra mkahelp pa tayo sa ibang seaman..slamat ulit

  • @samwinchester3591
    @samwinchester3591 11 месяцев назад +1

    nice video.2 rounds and finish off the tappet clearance,

  • @danmarkbutacan6516
    @danmarkbutacan6516 11 месяцев назад +1

    gawa ka din sir video ng testing ng mga safety devices hehe

  • @arturofuerto4987
    @arturofuerto4987 8 месяцев назад +1

    Good day, naa kay video unsaon pagkuha og performance sir. Nahurot na nakog download imong video. Hehehe

  • @gasperdickfloyd4865
    @gasperdickfloyd4865 Год назад +1

    Thanks po.
    Sir

  • @gsekhar036
    @gsekhar036 2 года назад +1

    Thank you very much brother

  • @romuloblanco4244
    @romuloblanco4244 9 месяцев назад

    Sir tanong ko lang. Ano pssible cause kapag ang fuel ay namix sa sump tank ng generator? At ano paraan para para maiwasan ito? Dapat ba palitan ng lube oil?

  • @billybohorquez1770
    @billybohorquez1770 Год назад +1

    Excelente trabajo

  • @rhodeislandred359
    @rhodeislandred359 Год назад +1

    Ano mangyari sa makina sir,pag hindi ma calibrate ang tappet clearance?
    Thanks and more videos sir

    • @makinistangseaman8665
      @makinistangseaman8665  Год назад +1

      Una mataas temperature ng exhaust mo brother ksi ng d timing ung pagbukas ng exhaust valve mo.and maingay dn ung generator mo brother

  • @dhomzbon6979
    @dhomzbon6979 Год назад +1

    Good day sir. parequest naman kung ano ung tamang procedure sa. pag adjust. ng 0 dun sa valve bridge. salamat

    • @makinistangseaman8665
      @makinistangseaman8665  Год назад +1

      Brother 1drop every 10~12 sec ang adjusting ng lub. Oil Brother.

    • @dhomzbon6979
      @dhomzbon6979 Год назад

      @@makinistangseaman8665 salamt sir . Doonpo sa may rocker arm T YOKE sir ung 0 clearance niya pano po tsmang procedure . salamat

  • @zenmusic6788
    @zenmusic6788 Год назад +1

    Solid!

  • @RC-807
    @RC-807 5 месяцев назад

    Good day sir ask ko lng sir bakit mas malaki ung clearance ng exh vv kesa intake vv ? salamat sir

  • @mdshatilislam8252
    @mdshatilislam8252 2 года назад +2

    Pls post the video at English so that everyone can understand

  • @nhuannhuan4106
    @nhuannhuan4106 3 года назад +1

    Could you plz explain Fuel oil bunker lines testing??

  • @richardboneo235
    @richardboneo235 3 года назад +1

    Sir idol, pwede po ba mag adjust or calibrate ng fuel rack sa generator, tulad ng sa Main Engine na pwedeng i adjust while running kapag sobra taas ng Exhaust Temperature? Bka po may tutotial kau or video. Maraming salamat po.
    Subscriber nio po ako, always watching your video.

    • @makinistangseaman8665
      @makinistangseaman8665  3 года назад +3

      Yes brother. Ginagawa ko bgo ko sya I adjust isang generator lang ang nadadala ng load, isang generator lng ang service/running bgo ka mag adjust ng fuel rack.take note brother kung hindi naman umabot or lumagpas ng 45°c ang difference ng temperature ng mga exhaust mo wag mo nalang I adjust. Or pagkatapus mo sya iservice itappet clearance mo sya.Slamat for asking brother. God bless keep safe

    • @richardboneo235
      @richardboneo235 3 года назад +1

      @@makinistangseaman8665 Video tutorial nmn sir kung papano mag adjust. Abangan ko po yan next episode. Salute sir.

    • @makinistangseaman8665
      @makinistangseaman8665  3 года назад +2

      Sure brother. Pwd paki share nlng dn nf vlog ntin pra makahelp dn tayo sa iba..Slamat keep safe God bless

  • @костян-п8ъ
    @костян-п8ъ 5 месяцев назад

    hello, what is the zero point, and how to set it?

  • @arjunv.v2336
    @arjunv.v2336 2 года назад +1

    Thanks bro but please try to speak in English.... It ll be big help to everyone

  • @kpmagusib1920
    @kpmagusib1920 3 года назад +1

    More video tnx

  • @Mvs..
    @Mvs.. Год назад +1

    Nice vid

  • @rayarnelrecepcion5959
    @rayarnelrecepcion5959 2 года назад +1

    👍

  • @stevenmchenry9276
    @stevenmchenry9276 Год назад

    You are a heroe

  • @AneesAlmamari-hv6dc
    @AneesAlmamari-hv6dc 4 месяца назад

    Okay

  • @DeePak-zw3jb
    @DeePak-zw3jb Год назад +1

    Brother valve bridge zero clearance is not required to adjust during normal routine. It is necessary to check zero clearance either when rocker arm is removed n put back or during cylinder head overhaul. Am I right?

  • @palawenongmakinista6299
    @palawenongmakinista6299 2 года назад +1

    Sir may recommended clearance din po between rocker arm and Valve Bridge? Sana ma notice Engine cadet from Palawan.

    • @makinistangseaman8665
      @makinistangseaman8665  2 года назад +2

      Yes brother. Sa valve bridge is zero sa rocker arm meron dn..depends sa model nasa manual yn brother.

    • @palawenongmakinista6299
      @palawenongmakinista6299 2 года назад +1

      Thank you sir and more videos God bless!

  • @marinersvlog111
    @marinersvlog111 3 года назад +1

    Can you send me the manual pdf copy?

  • @mec6953
    @mec6953 2 года назад +2

    sir, how do i make sure, valve bridge is in "zero point"?

    • @makinistangseaman8665
      @makinistangseaman8665  2 года назад +3

      Tighten the adjusting screw of valve guard little by little while holding the upper part and just then clearance to be on zero point.after adjusting fix the adjusting screw and tighten the lock nut..thank you brother

  • @ams4302
    @ams4302 2 года назад +1

    Make videos in English bro

  • @dendenmark1447
    @dendenmark1447 2 года назад

    normal ba na madaming lumalabas na oil sa rocker arm? as in sirit tlaga

    • @makinistangseaman8665
      @makinistangseaman8665  2 года назад

      Pagpaandar mo sa L.o primary pump ml brother mahina lng yn patak2 lng..D normal yn brother..

  • @anicetosalve6772
    @anicetosalve6772 Год назад +1

    Ang tagal u nman kumuha Ng toppit clearance

  • @makara3646
    @makara3646 2 года назад +1

    Translate Indonesia bro 🙏

  • @ganeshrane9782
    @ganeshrane9782 2 года назад +1

    bro make videos in ENGLISH.

    • @makinistangseaman8665
      @makinistangseaman8665  2 года назад +1

      OK brother

    • @ganeshrane9782
      @ganeshrane9782 2 года назад +1

      @@makinistangseaman8665 cause it get very difficult to understand what you explaining......

  • @mustafaburakal3820
    @mustafaburakal3820 Год назад +1

    omg this prononciation is killing me a bottle of water speaks better

  • @rhodeislandred359
    @rhodeislandred359 Год назад +1

    Ano mangyari sa makina sir,pag hindi ma calibrate ang tappet clearance?
    Thanks and more videos sir

    • @makinistangseaman8665
      @makinistangseaman8665  Год назад +1

      Maingay ung generator and d timing yng pagbukas ng mga valve mo brother kaya tatas ung exhaust temperature ng mga cylinder mo brother