Does ProtaStructure Overdesign or Underdesign a Beam?

Поделиться
HTML-код
  • Опубликовано: 10 дек 2024

Комментарии • 6

  • @mojeedobisesan6748
    @mojeedobisesan6748 Год назад +1

    Well explained, well done 👏. Thank you.

  • @afzalhussain7466
    @afzalhussain7466 2 года назад

    Thanks so much great work for beginners

  • @alisrour3228
    @alisrour3228 Год назад

    Thank you, good job

  • @oyekunleadekunle1354
    @oyekunleadekunle1354 2 года назад +1

    Thanks for good job

  • @engabdiwaliahmed7717
    @engabdiwaliahmed7717 2 года назад +1

    Error/Warning List
    Axial Load Comparison Warnings:
    Warning: Difference between decomposed loads and slab loadings
    is (%) =5.44
    Yield Line approach for beam load decomposition may not be adequate for this model.
    Warning: Difference between Building Analysis Results and Undecomposed Slab Loads (%) = 5.44
    Building model should be checked.
    Refer to Axial Load Comparison table for more detailed information.
    i have found this issue while analysing my G+6 model, how i can correct?

  • @afzalhussain7466
    @afzalhussain7466 2 года назад

    Nice work