Causes: Hardware error • Input - Output connector is disconnected. • Input - Output harness is short-circuited. • The transfer unit is not set properly. • IOB error (signal error) • HVPS defective load error * Grounding fault of separation power output, short-circuit with other outputs • Surface/air clearance insufficient in separation power output path (including distance from other outputs) Do: main power off- on • Reconnect or replacethe harness of the HVPS (power pack). • Reconnect or replace the harness between the BCU and the HVPS. • Reset or replace the trausfer unit. • Check if the contact and separation movement of the transfer unit works correctly. • Replace the HVPS. • Replace the BCU.
Transfer power pack output error An interrupt checks the status of the power pack every 2 ms. This SC is issued if the VBCU detects a short in the power pack 250 times at T2 within 500 ms. Damaged insulation on the high-voltage supply cable • Damaged insulation around the highvoltage power supply. • Check SIOB harness connections • SIOB defective.
Check if the drawer unit is closed correctly using the following procedure.. 1. Turn off the machine power and pull out the drawer unit 2. Close the drawer unit completely and turn on the machine power. 3. Make 2 or 3 copies and confirm the error message has disappeared. If not.. Remove the high voltage cable from the output terminal of the separation power pack and check the following items. * PWM signal check. (If signal is fixed during image transfer replace the cable or the IOB ) * Separation powerpack output check. ( If I would put his fixed during the image transfer replace the power pack if output is normal during image transfer replace the high voltage cable order the quenching needle.
Pressure roller thermistor error: Centre The temperature at the centre of the pressure roller measured by the thermistor does not reach 0°C for 37 seconds. * Loose connection of the thermistor * Defective thermistor 1. Check if the thermistor is firmly connected. 2. Replace the centre thermistor. Since you have replaced the entire fusing unit, my thought would be the machine side of the fusing connector or the leads for the pressure roller centre thermistor.
thank you very much !
Glad it helped!
thanks
How to clear error sc460 on RICOH MP 5054(B/w copier)
Causes: Hardware error • Input - Output connector is disconnected. • Input - Output harness is short-circuited.
• The transfer unit is not set properly.
• IOB error (signal error)
• HVPS defective load error
* Grounding fault of separation power output, short-circuit with other outputs
• Surface/air clearance insufficient in separation power output path (including distance from other outputs)
Do:
main power off- on • Reconnect or replacethe harness of the HVPS
(power pack).
• Reconnect or replace the harness between the BCU and the HVPS.
• Reset or replace the trausfer unit.
• Check if the contact and separation movement of the transfer unit works correctly.
• Replace the HVPS.
• Replace the BCU.
Hope rhis will help you
please help mi ! SC450 on MPC6501
Transfer power pack output error
An interrupt checks the status of the power pack every 2 ms. This SC is issued if the VBCU detects a short in the power pack 250 times at T2 within 500 ms.
Damaged insulation on the high-voltage supply cable • Damaged insulation around the highvoltage power supply. • Check SIOB harness connections • SIOB defective.
Sc460 off mpc6502. Help mi
Check if the drawer unit is closed correctly using the following procedure..
1. Turn off the machine power and pull out the drawer unit
2. Close the drawer unit completely and turn on the machine power.
3. Make 2 or 3 copies and confirm the error message has disappeared.
If not..
Remove the high voltage cable from the output terminal of the separation power pack and check the following items.
* PWM signal check. (If signal is fixed during image transfer replace the cable or the IOB )
* Separation powerpack output check. ( If I would put his fixed during the image transfer replace the power pack if output is normal during image transfer replace the high voltage cable order the quenching needle.
Good luck 🤞
Ricoh MPC 4503 error Code SC 571-00 help me
Pressure roller thermistor error:
Centre
The temperature at the centre of the pressure roller measured by the
thermistor does not reach 0°C for 37 seconds.
* Loose connection of the thermistor
* Defective thermistor
1. Check if the thermistor is firmly connected.
2. Replace the centre thermistor.
Since you have replaced the entire fusing unit, my thought would be the machine side of the fusing connector or the leads for the pressure roller centre thermistor.
If this is not sorted, let me know, pls.
Thanks