@@letsfun7717 Base jacks Base jacks shall be provided with a centrally positioned adjusting spindle of such dimensions that, in the unloaded condition, the greatest inclination of the axis of the shaft from the axis of the standard does not exceed 2,5 %. The minimum overlap length at any position of adjustment shall be 25 % of the total length of the shaft, or 150 mm whichever is greater. The thickness of the endplate shall be at least 6 mm. Shaped endplates shall have at least the same rigidity. Ref.BSEN 12811- 1 U Jack - same formula applied or you may use manufacturer instruction manual for better clarity
Thank you very important video sit
🙏
Thank very much sir
You are welcome 🤗🙏
Sir please make one video about calculate square meter and progess
Thanks u sir
Welcome
Please make a difference vod. About scaffolding
Thanks for your valuable feedback 🙏
1m ka u- jack maximum kitna open kr sakte he
Please answer the sir
@@letsfun7717
Base jacks
Base jacks shall be provided with a centrally positioned adjusting spindle of such dimensions that, in the unloaded
condition, the greatest inclination of the axis of the shaft from the axis of the standard does not exceed 2,5 %. The
minimum overlap length at any position of adjustment shall be 25 % of the total length of the shaft, or 150 mm
whichever is greater. The thickness of the endplate shall be at least 6 mm. Shaped endplates shall have at least
the same rigidity.
Ref.BSEN 12811- 1
U Jack - same formula applied or you may use manufacturer instruction manual for better clarity
Sir mejar ment kaise nikalte hai or meterial kabhi
@@urjeshkumar8 ruclips.net/video/HqL_kpCzLok/видео.htmlsi=kGeThNRp3MnP9FEg