Mitsubishi FR Configurator 2, Mitsubishi E700 parameter upload, download and file save. (English)

Поделиться
HTML-код
  • Опубликовано: 10 дек 2024

Комментарии • 33

  • @atothek1804
    @atothek1804 11 месяцев назад +1

    Thank you sharing Information on your videos to all VFD related topics. Those vids has been very very valuable and helpful! 😊😊😊😊

  • @atothek1804
    @atothek1804 11 месяцев назад +1

    Note When choosing USB cable between computer-to-inverter data transfer.
    You looking USB cable where in the USB micro end connector has a stamp letter "B".
    In cable other a bigger computer end, has a regular USB A male connector.
    I hope his help to others a avoid nasty IT related problems. 😉

  • @shailendrabisht8927
    @shailendrabisht8927 Год назад

    very mean full video thanks for sharing it .

  • @atothek1804
    @atothek1804 11 месяцев назад +1

    Naming convention is kind odd because (older version of this FR Configurator 2 software) is called FR Configurator SW1, --> suitable for E500 series inverter. Advanced FR Configurator SW3, --> is suitable for D700 series and also other 700 series Inverter I'm sory because whose alphabet letters I can't remember exactly. Anyway anyone can check that info in the "Mitsubishi website" and there under "Download" section choose "Software". There is a available actually just right older applications so many different language which is just named a little differently.

  • @Khushboofd
    @Khushboofd 3 месяца назад

    Sir i have A740 vfd Mitsubishi. My set button not working so I can't change any parameters. So i connect my vfd with FR confuigurator and changed in 79 parmeter set 2 . Now my vfd running in ext mode with external potentiometer. But when power goes off my vfd automatically gone in NET mode whether 79 parameter 02 is present

  • @ramkhambete7650
    @ramkhambete7650 2 года назад +1

    Please give specification of cable used for E800 Mitsubishi drive parameters upload and download

  • @shahariarnakib6517
    @shahariarnakib6517 3 года назад

    Thank u sooooooooooooo much...
    it helped me a looooooot.....

  • @mrtrader4628
    @mrtrader4628 4 месяца назад

    Very good information and I did get a copy of the software, but it is a demo version for 20days do you know how to get key to have it always?

  • @simiocean7790
    @simiocean7790 10 месяцев назад

    hello i have problem with my E700 to control the yc-aembossing napkin folder,.the output from E700 w1-288,u1-288 & v1-145

  • @dadyut
    @dadyut Год назад

    Its support to FR D720S ?

  • @RhinoMC_SA
    @RhinoMC_SA 10 месяцев назад

    Thanks for sharing

  • @andybrown3715
    @andybrown3715 2 года назад +1

    Great video but I couldn't get it to work for me - kept getting errors. Not very intuitive to use compared to other manufacturers.

    • @eurotropia
      @eurotropia Год назад

      I fully agree! I have been struggling a lot with these inverters!

  • @eurotropia
    @eurotropia Год назад

    😦I bought FR-E720S-SC-EC inverter and connected to FR configurator. The program auto recognized it and I managed to do batch reading. I was so happy, however, it never worked again! I did nothing at all. I bough new cable but it's not the fault. I got message 0x80010102 "The data received by the computer contains incorrect data". I set the VFD back to factory settings. The Windows 10 device manager see the controller works properly. PLEASE advise!

    • @eurotropia
      @eurotropia Год назад

      🙁After multiple attempts, the software finds the drive then after a few second, it becomes disconnected with the same error message I mentioned above (0x80010102). What could be this? It looks like something with the settings! Please advise!

    • @eurotropia
      @eurotropia Год назад

      HEY! I can see at the end of the video that you had the same problem (disconnection with 0x80010102 message)!!! Should I try on a faster PC? Maybe it is something with memory???

    • @eurotropia
      @eurotropia Год назад

      😒Carrying on chatting with myself, the 0x80010102 disconnection issue might be resolved with buying the MR-J3USBCBL3M cable according to the specifications. This means that the general USB Mini cable is not good enough....even a short one will fail.

  • @louisdewamin1332
    @louisdewamin1332 Год назад

    Hi,can we do the download/upload with FR Configurator 1 for the FR-D700 serie?

    • @atothek1804
      @atothek1804 11 месяцев назад

      yes it can. Naming convention is kind odd because older version of this (FR Configurator 2) is called FR Configurator SW1, --> for E500 series inverter. FR Configurator SW3, --> for D700 series and also other 700 series Inverter whose alphabet letters I can't remember exactly. Anyway that info can be found in the "Mitsubishi website" and there "Download" section under choose "Software". There is a available same application so many different language which is just named a little differently. Note When choosing USB cable between computer-to-inverter data transfer. You looking cable where in the USB micro end has a letter "B". In cable bigger end has a regular USB A male connector.

  • @clsullad
    @clsullad 2 года назад

    hi sir , can you help me with mitsubishi fr-d740 vfd programming connector cable pinout diagram thank you

  • @mr.billalhossain1115
    @mr.billalhossain1115 3 года назад

    Good video!!!

  • @asifislam7376
    @asifislam7376 8 месяцев назад

    Is it possible by ethernet?

  • @KalimullahPakistan
    @KalimullahPakistan 3 года назад

    Very good information.
    How can i drive Mitsubishi e520 through computer? Speed control run command activation

    • @IGSElectronics
      @IGSElectronics  3 года назад

      You will need special cable to connect to drive via serial port.

  • @jeanpierredaddymutabazi643
    @jeanpierredaddymutabazi643 2 года назад

    Hi ihave mutsubish D700 which control dish washer but it's failed, can you help me how i can configurat again so that it's can read the signals from washer machine pcb card

    • @IGSElectronics
      @IGSElectronics  2 года назад

      These kind of diagnostics can only be done on site. Sorry cant help you on this matter.

  • @tuanbeo969
    @tuanbeo969 2 года назад

    how can i copy the parameter from the old inverter to the new one?thank you so much

    • @cassiotrappkruger9466
      @cassiotrappkruger9466 10 месяцев назад

      Connect the laptop to the old, and do the "read batch". Save the parameters list.
      Connect the laptop to the new one, open the saved file, and do the "Write batch"

  • @shahariarnakib6517
    @shahariarnakib6517 3 года назад

    I wanna use pendrive in Mitsubishi F800 series to upload and download my perameters
    usually i work with (FR - F840- E3 -00620) which is 30KW driver.
    can u help me with a video plz.....

  • @basukiasat2809
    @basukiasat2809 3 года назад +1

    Nice