Hive Thermostat Mini Installation In 10 Mins - Combi Boiler Wiring | Worcester 2000

Поделиться
HTML-код
  • Опубликовано: 11 сен 2024
  • These resources will teach you how to diagnose and fix any boiler: signup.advance...
    This is a walkthrough on how to wire a Hive Thermostat Mini on a Worcester 2000.
    Tools used in this video:
    Nws multi cutters: amzn.to/3XosG6n
    Knipex ergostrip: amzn.to/3jLl4NP
    Voltage tester screwdriver: amzn.to/3HXHeEF
    Stanley Spirit Level: amzn.to/3YGXQag
    Makita Drill and Impact Driver: amzn.to/3XqFR6T

Комментарии • 106

  • @mpoiuytr
    @mpoiuytr Год назад +10

    This is the ONLY reference I can find to setting up the Hive mini in remote mode. Not only that, but it was done simply and with all the caveats (duration etc) that you need. Subscribed!!!

  • @reezsj5139
    @reezsj5139 Год назад +4

    Your’e a star! Hive website doesn’t explain fully well the wiring between the “common” , “live” and “hot water on” terminals. I’ve gone all through the manuals and community resources but none of it. Since I’ve followed the wiring, it was magic to hear my combi boiler come to life with the heater.

  • @Saf_R
    @Saf_R Год назад +13

    Solid vid this is how you explain things so thorough. And one handed too 😂 well done man

    • @advancedboilertraining
      @advancedboilertraining  Год назад

      The one handed struggle is horrible sometimes 🤣

    • @Saf_R
      @Saf_R Год назад +1

      @@advancedboilertraining lol just imagine if you were a boxer 😂😂👊🏾

    • @mgbroadsterJ
      @mgbroadsterJ Год назад +1

      what about getting it on the phone and connected to the hub .

    • @advancedboilertraining
      @advancedboilertraining  Год назад

      @@mgbroadsterJ this is the hubless version. I’m releasing a video tomorrow at 7pm on how to do the hub and app

  • @andreibudaes3966
    @andreibudaes3966 Год назад +5

    Thanks. I initially installed this using the wiring from my old thermostat and added L, N and 3...it seemed to be working, the receiver made a click when the thermostat target was above the actual but nothing happened...in your video I've seen the link between L and 1 so after adding that it worked

  • @octavianduma252
    @octavianduma252 Год назад +1

    Amazing! I installed my hive remote controller by myself! Thank you a million times!

  • @jinxUKBK
    @jinxUKBK Год назад +3

    So many video on installation of this and your has to be one of the simplest and on point. Well done sir

  • @bsaunder359
    @bsaunder359 Год назад +5

    Absolutely brilliant vid. Very very very helpful. Keep it up bro.

  • @edd30t4vw2
    @edd30t4vw2 Год назад +3

    Man, I didn't realise Raheam sterling had another job. Sounds just like him 😂 Great vid.

  • @jonesboy201
    @jonesboy201 2 месяца назад

    Another great video. Can you post a video installing the mini as part of a multi zone installation. Just bought a hive multizone system for my daughter and it would be helpful to see how this is installed for use in an upstairs heating zone.

  • @posei3960
    @posei3960 Год назад +5

    Non compliant with BS7671
    Grey needs sleeping brown to indicate a "live" conductor
    All points should have an Earth wire even if it is not used. Earth termination in the parking terminal,in the rec ivermalso acts as retention point to,act as strain relief
    Ferrules on the cable,would be a nice touch

  • @train4905
    @train4905 Год назад +1

    Still awsome,come in really handy,again sir thanku loads😊

  • @seenarachelgeorge6348
    @seenarachelgeorge6348 Год назад +2

    excellent video and that helped me. Thank you

  • @James-oy3qp
    @James-oy3qp Год назад +2

    Great video thanks that was so helpful. Top man

  • @AntzProdCast
    @AntzProdCast 8 месяцев назад

    This is a great vid, would only say though, please use the G/Y earth cable in the earth. this will help protect the flex correctly.

  • @daleullbricht
    @daleullbricht 11 месяцев назад +1

    Really good detailed video! 👌 nice one mate

  • @train4905
    @train4905 Год назад +1

    Brilliant job sir,well done,and really well explained,thanku

  • @MarkRobson99
    @MarkRobson99 Год назад +1

    Thanks man! You saved me £99

    • @advancedboilertraining
      @advancedboilertraining  Год назад +1

      You could thank me by sending me £98 on PayPal 😉

    • @MarkRobson99
      @MarkRobson99 Год назад

      @@advancedboilertraining the cheque is in the mail 😜

  • @ozoid
    @ozoid 10 месяцев назад +1

    Awesome video, helped a great deal 😊

  • @Stu_Gilbert
    @Stu_Gilbert Год назад +2

    Another nice video dude thanks 👍

  • @chrisb4009
    @chrisb4009 Год назад +4

    You should always use and earn in a cable if you can. If a persons cuts through the cable it may well save their life

  • @adamsala9291
    @adamsala9291 Год назад +1

    Nice channel nest on RUclips 👍

  • @jakubkonieczynski8640
    @jakubkonieczynski8640 8 месяцев назад

    Great video mate

  • @garyfryer4920
    @garyfryer4920 9 месяцев назад

    Great video mate helped alot thankyou 👍🏻

  • @nkhalid677
    @nkhalid677 Год назад +1

    Thanks mate next video for multi zone please

  • @neilstevens9729
    @neilstevens9729 7 месяцев назад

    Great simple video. Two questions. Is it OK not to connect an earth? I read that the Hive is double insulated - it's plastic - so it's not necessary. Also the no. 3 terminal is the switched live, right? Thanks.

  • @jamesnunn4962
    @jamesnunn4962 8 месяцев назад

    Easy to follow thanks 🙏

  • @twat69
    @twat69 Год назад +1

    Thanks Man

  • @robmitch69
    @robmitch69 Год назад

    Thanks mate. Brilliant video

  • @rjkelectrical6086
    @rjkelectrical6086 3 месяца назад

    Cutting off the earth naughty boy 😂😂

  • @simonbeal2148
    @simonbeal2148 Год назад +4

    would have been good to sleeve the grey wire with some brown sleeving to show its a live wire

    • @russlees2589
      @russlees2589 Год назад

      Not necessary as grey is a 'live' colour. Brown , black and grey are the three live phase colours.
      PS - To original video maker, great video 👍 how great you'll be when your third hand grows 😂

  • @NickG24
    @NickG24 8 месяцев назад

    Great video, thanks. Am just thinking about a Hive but not sure which to choose, this is way neater without the hub so surely it’s the better choice? What’s the difference, why would you choose one with a hub?

  • @train4905
    @train4905 Год назад +1

    Exellent video work

  • @Nkrumaheducation
    @Nkrumaheducation Год назад +1

    Thank you bro

  • @thedirtychips8556
    @thedirtychips8556 9 месяцев назад

    Do one about connecting the hub pls

  • @cynderyn56rh
    @cynderyn56rh 7 месяцев назад

    Excellent tutorial upload on hive min - Worcester that any DIY can follow. I presently have an old
    Honeywell kit Y6630D Wireless Analogue Room thermostat. Can you please offer any wiring advice on on how I can use the existing external wires that now go into honeywell receiver to wire the hive receiver rather than open boiler apologises because this comment is off the main topic

  • @williamlawrenson8345
    @williamlawrenson8345 8 месяцев назад

    Morning. I've accidentally bought the dual channel unit for my combi boiler instead of the single channel. I've moved the wire from 2 to 4, the heating on terminal. Should I remove the link wire between 1 and live or leave it in place? Thanks.

  • @demcny8941
    @demcny8941 9 месяцев назад

    Is it possible to link a Hive thermostat to an existing installed receiver (not a Hive receiver)?

  • @HimanshuVerma-zn7cb
    @HimanshuVerma-zn7cb Год назад +2

    Linking up L and 1 is very important point to note. it didn't work with out this linking up. Thanks for telling us. Shame on hive even though they make the product , Instructions doesn't work.

  • @Burncash1510
    @Burncash1510 Год назад +1

    Does it matter which terminal the grey cable goes into could it be terminal 2 or 4 instead of 3 would it make any difference thanks great video bro.

    • @advancedboilertraining
      @advancedboilertraining  Год назад

      It should go into 3👍

    • @kevwilliams5134
      @kevwilliams5134 Год назад

      @@advancedboilertraining I'm wiring into an Ideal Logic 30, grey wire into 3, the thermostat kicks in the controller and it lights up green but no go with the heating. Unsure if this is normally open or normally closed. Previously had a Horstmann HRFS-1 T50 installed

  • @kroozer5215
    @kroozer5215 10 месяцев назад

    i have a worcester 2000 and when i remove my panel to expose the wires etc they look nothing like yours - there is no LR LS NS N L - all i have is a blue block, brown block and a orange block that has 2 connections on each with 2-1 2-1 2-1 the orange block has BUS written on it, i have scoured the net to look for these same connections to fit a hive and cannot find anything like mine

  • @rajnirvan3336
    @rajnirvan3336 8 месяцев назад

    Can an earth wire be used on the hive thermostat new cable with permanent/switched live and neutral

  • @glennyc01
    @glennyc01 Год назад

    how would this be installed if all you have is a two wire thermostat installed? and only two wire connections for a stat on the boiler?

  • @mohammedchowdhury195
    @mohammedchowdhury195 Год назад

    Hi, great video. I want to upgrade my thermostat, I checked my current Honeywell thermostat, it only has two wires, blue and brown. Would I require a new wire?

  • @davidmcateer5483
    @davidmcateer5483 Год назад

    Hi great video. I have a worchester 2000 combi with the standard programable thermostat that uses the cartridge underneath the boiler to communicate with. I was told the hive system are not compatible with these boilers, is this no longer the case or do u have to get the hive mini for it to work 🤔 also can u still control the heating using the hive app with this mini, thanx

  • @nickclayphan1141
    @nickclayphan1141 11 месяцев назад

    Hiu I have an original Worcester 2000 boiler which was supplied with its own wireless thermostat. I had hive and was told this was not compatible, The model No is GC2000iW C and all electricians I spoke to inc manufacture said its not compatible, then they updated boiler to be compatible. I want to use my Hive, as their supplied thermostat is very basic

  • @SimplyDIYDee
    @SimplyDIYDee Год назад

    Just curious but what’s the reason why this isn’t using the space where the current Honeywell thermostat is in please?

  • @stefaniaion
    @stefaniaion 11 месяцев назад

    the thermostat needs to stay on the wall?

  • @ChelseaFC190512
    @ChelseaFC190512 11 месяцев назад

    So you wire from the fuse spur straight into the boiler)

  • @cupcakefamily5271
    @cupcakefamily5271 8 месяцев назад

    Hi, thanks for your videos, i found your video with Main Eco e30 elite boiler and Salus Thermostate, and 2nd video with Hive mini thermostate and Worcester boiler, but i have Hive mini thermostate and Main eco 30 elite, did wiring in boiler as u mentioned in salus video and did wiring in hive as mentioned in hive video, but boiler not switching heating ON when i increased the temp in hive thermostate, hive thermostate gas green light comes ON but boiler gas does not comes ON. pls help

  • @nataliegamble7225
    @nataliegamble7225 Год назад +1

    I’ve already got a thermostat in place, it’s a dial but did have a digital one before (landlord replaced it cheaper). Am I right in thinking wouldn’t need to update the boiler and it would just be a case of installing the receiver where the thermostat dial is now?

  • @_K.T.B_
    @_K.T.B_ 11 месяцев назад

    Did you use the existing wires inside the boiler to connect this or did you buy extra wires to install it? Handy video but I just couldn’t work out whether you used new wires or used the existing wires 🙈

    • @ozoid
      @ozoid 10 месяцев назад

      A new wire, I bought some 4 core 1mm

  • @sheriefgerges7789
    @sheriefgerges7789 Год назад +1

    Great video,
    Is the difference between hive and mini hive is that the extra hub ?

    • @advancedboilertraining
      @advancedboilertraining  Год назад +1

      Yeah the hive mini is hubless

    • @Tom-fs4ue
      @Tom-fs4ue Год назад +1

      Incorrect. If you buy the full hive mini kit it’s comes with the hub also. This set up was just the thermostat & receiver which is a cheaper alternative

    • @advancedboilertraining
      @advancedboilertraining  Год назад

      @@Tom-fs4ue yeah this is the hubless one

    • @davidmcateer5483
      @davidmcateer5483 Год назад

      Great video. I have a worchester 2000 combi with the standard wireless thermostat it uses a cartridge underneath the boiler, i was told the hive isnt compatible with this boiler, will this mini hive still allow me to control the boiler through my hive app

  • @peterhutchings6356
    @peterhutchings6356 Год назад

    Hello, would the hive mini fit a Worcester Bosch green star 8000 boiler or would it need the larger hive unit?

  • @cookbookforcannibals
    @cookbookforcannibals Год назад +1

    do you need the hub to use the mobile app whilst on your home wifi? (i know you need it for outside of your home network)

    • @advancedboilertraining
      @advancedboilertraining  Год назад

      Yeah you need the hub to use the app

    • @cookbookforcannibals
      @cookbookforcannibals Год назад

      @@advancedboilertraining I thought that would be the case, not a huge amount of clear info around though. Honestly don't really need the app functionality though

  • @ArksE8
    @ArksE8 Год назад +1

    I usually wire the receiver while it's off the wall

  • @biorbfan
    @biorbfan Год назад +1

    How do i add the hub at a later date ? what do i pair first with the hive hub? Sorry to bother .

    • @advancedboilertraining
      @advancedboilertraining  Год назад

      This is the hubless version. I’ll be posting a video within the next week on how to set up the hub

  • @markkendall6144
    @markkendall6144 Год назад

    What did you do with the hub

  • @MrRawMonkey
    @MrRawMonkey Год назад +2

    Why fit a smart thermostat that can’t modulate a modulating boiler?

    • @advancedboilertraining
      @advancedboilertraining  Год назад

      Because it’s what the customer picked. He got it really cheap off of someone and wanted it fitted. I advised against it but that’s what he wanted

    • @effervescence5664
      @effervescence5664 Год назад

      It's alright, under the Part P Plus and Part L legislation it's the customer that faces the £5k fine if they go to sell or rent and it's picked up as non-compliant.
      If you're supplying and installing though you have no choice but to fit one that complies or the responsibility and cost falls on you as the installer.

    • @macbutty1
      @macbutty1 Год назад

      Which opentherm stat would you recommend for Intergas Rapid 32

    • @olalekanoyedokun4494
      @olalekanoyedokun4494 Год назад

      That's what BG is fittings for the customers, and it works. Not everyone will have money to purchase the nest thermostat. Some are found to find fault in what seems to be a post

  • @peterhutchings6356
    @peterhutchings6356 Год назад

    Would this same install apply for the WB 8000 series too?

  • @adamsala9291
    @adamsala9291 Год назад

    Honeywell T6360B thermostat is it same wiring.

  • @mattfm101
    @mattfm101 Год назад

    I'm a total ameteur I have just recently replaced my kitchen cabinet which had a digistat SCR coming in below it. I didn't want to cut out a hole in my new cabinet and took it off the wall. It is hanging off the wall at the moment and made me think about replacing it with something more high tech for my ecotec plus boiler. I noticed something odd or at least odd to me, when I took it off the wall I assumed it would only be connected up to the boiler as that was the only large white cable I could see but then there was a second one in the wall. I'm now even more confused looking at this guidance video as there is only one large cable connecting the two together like I assumed there would be with mine.
    Any idea what the second cable is for?

    • @mattfm101
      @mattfm101 Год назад

      It's Ok I figured it one was going to a fused spur the other was going to the boiler.

  • @mymistake8998
    @mymistake8998 3 месяца назад

    You havent explained how to use the control and what does "actual" and "target" mean .

  • @c1tlr340
    @c1tlr340 Год назад

    I just installed one of these today in stand alone mode like this. The documentation that comes with it and the installation instructions online are dreadful.
    I installed as per instructions and nowhere does it mention the link between live and terminal 1.
    I read the manual for the thermostat I removed and it mentioned linking L and terminal no 1.
    Once I did it the hive worked as it should.

    • @advancedboilertraining
      @advancedboilertraining  Год назад +1

      Yeah the instructions aren’t the easiest of things to follow. Hope the video helped 👍

  • @aseebyounis2585
    @aseebyounis2585 Год назад +1

    Is it the same installation for hive v3

  • @davidmoore3524
    @davidmoore3524 Год назад +1

    Good video but why the gloves ??

    • @advancedboilertraining
      @advancedboilertraining  Год назад +1

      So I don’t wreck my hands 😂 it’s just a habit. Before I go into any job, big or small I put on gloves

  • @David_Khu
    @David_Khu Год назад

    “Earth” needs to be connected!

  • @Jx1de16
    @Jx1de16 9 месяцев назад

    It’s not flashing orange

  • @WhiteTigersDaughter
    @WhiteTigersDaughter Год назад +1

    I thought number 1 on the receiver is ‘common’ and you leave it. I’m only asking because Ive messed up and I have no heating. Hive are blaming the wiring

    • @advancedboilertraining
      @advancedboilertraining  Год назад

      Yeah so if you wire it exactly the same in my video then it’ll work. The Hive instructions aren’t clear at all

    • @WhiteTigersDaughter
      @WhiteTigersDaughter Год назад

      I’ll give it a go. Thank you!

  • @jockster5525
    @jockster5525 Год назад +2

    Quality mate 💪

  • @markblackburn969
    @markblackburn969 10 месяцев назад

    Use 5 core much easier