    @mariush2429 Год назад

    @elmeonline9932 Thanks for the video! Would you have any idea why the timer for the "Fill" is not working?(even though the tank fills up - for 8 seconds) The timer for "Discharge" works just fine. Thanks again!

  • @johnnyginderskov6943
    @johnnyginderskov6943 2 года назад +1

    Hey pal.. great videos.. i'm completely new to all of this and this is my first scene in Factory, do you have a little clue how to solve the issue when the discharge button is normally closed..? i can't seem to figure it out.. 😞 thx in advance..

    • @elmeonline9932
      @elmeonline9932  2 года назад

      Without looking at your exact logic, I can't say for certain. If the "real world" contacts of the discharge button are NC contacts (like most stop button contacts are), you could pretty much do the same thing as I did with the fill by changing the instruction in the ladder to a normally closed. It gets confusing, but a normally closed ladder instruction addressed to a NC real world contact will be open until the button is pressed. Hope this helps.