Dangerous Wiring with Extension Cords and other Code Violations | Electrical Repair

Поделиться
HTML-код
  • Опубликовано: 21 ноя 2024

Комментарии • 78

  • @iroc341
    @iroc341 11 месяцев назад +3

    WOW! It's amazing that more houses don't burn down. You know this goes on every day, in millions of houses!

  • @mohammedelsayed2889
    @mohammedelsayed2889 Год назад +12

    this is the best type of content, code violations and repair. like always, clean work!

  • @mackfisher4487
    @mackfisher4487 Год назад +2

    Pretwist wire nuts, good man.

  • @hellen70666666
    @hellen70666666 Год назад +1

    ....:) Still Impressed....!!!!.....:)

  • @ed6837
    @ed6837 5 месяцев назад +1

    That garage was nasty. The things people do. Nice job.

  • @garbo8962
    @garbo8962 Год назад

    A few years ago at a continuing education class a few years ago the instructor told us it was never legal to run type NM cable ( yea Romex ) to an outdoor box even thru the back of a bell box lime you did. This cable is not approved for damp or wet locations. Told us to run UF cable. Hope no inspectors looks inside of the two quality Killark aluminum FS boxes that I installed on my outside walls over 45 years ago. A POS flimsy bell box would never remain dry all of them years. Hope the homeowners had a lot of fire insurance , sprinkler system and smoke/CO2 detectors before you showed up. Nice that you went the extra effort using g a deeper 4" junction box ( 1900 box ). Great set up & best in class paint job on your van.

  • @simon359
    @simon359 Год назад +2

    One thing I’ve learned from doing my own wiring now, and its basic wiring, not anything complicated. If I buy another house, make sure I check all the wiring!

    • @electricianron_New_Jersey
      @electricianron_New_Jersey  Год назад

      It;'s not a bad to hire an electrician to do a quick review and suggest what should be upgraded. I had a customer once move to Massachusettes and call me to ask about a few things at the house he bought.

  • @andrewdimauro7352
    @andrewdimauro7352 Год назад +1

    “This is Trey with gold star inspections and that ain’t right” 😂😂😂

  • @GregO-uj8jt
    @GregO-uj8jt Год назад

    Thanks for all your videos. Every time I watch them I feel like am there working with you side by side. Thanks again your a great teacher.

  • @kevinstrauss8020
    @kevinstrauss8020 Год назад +1

    I’m surprised you used an MC connector going into the back of the exterior outlet box. You’re lucky the inspector won’t see that.

  • @patricklantzy
    @patricklantzy Год назад

    Loved the use of a level to insure everything is aligned..

  • @ans1020
    @ans1020 Год назад +1

    I’m convinced some guys just love to do janky work. They like the “tree house” feel in their garage. It’s weird.

  • @arnieselectric007
    @arnieselectric007 7 месяцев назад

    Always a pleasure watching even the simple things...😃😉😎

  • @jerryoles3688
    @jerryoles3688 Год назад

    Nice use of the term objectionable current! Should have cited 250.6 also
    Keep fighting the good fight, from a fellow spark in VT

  • @m3rdpwr
    @m3rdpwr Год назад +1

    At the beginning of the video, when you stuck your pinky into the top of that electrical box, I cringed. I then realized you obviously already disconnected the power. LoL

  • @spencerholt7485
    @spencerholt7485 8 месяцев назад

    I love your videos and this is my 3rd year in the field! Looks like you could use some help and would love to learn from you!

  • @larryzapotocky1363
    @larryzapotocky1363 3 месяца назад

    😮🤦‍♂️ Wow! Love your videos!

  • @Belleelectrical
    @Belleelectrical 8 месяцев назад

    Good work! Sorry bout the jets

  • @billhandymanbill2775
    @billhandymanbill2775 Год назад +2

    Nice video! At 13:00 in the video, I am surprised that you didn't use "grey duct seal" instead of a white sealant/chalk to seal the hole in the brick wall. Why? Also, according to the NEC, don't they now require a "bubble" cover on outdoor outlets so an electrical plug can be inserted into the outdoor outlet and rain and snow don't get into the electrical circuit?

  • @roybreeden8928
    @roybreeden8928 Год назад +1

    Hey Ron, I really enjoy your videos. Been in the electrical and power industry almost 40 years. We call that bootleg wiring here in East Tennessee as well. Hahaha!

  • @osvaldomcs1213
    @osvaldomcs1213 Год назад

    You should always tape the receptacle in a metal box. It's good practice.

  • @adassociates8235
    @adassociates8235 Год назад

    does reroute wire on ceiling need run in metal pipe? as wire still expose on garage with code violation , we guess

  • @jeremyniemiec7964
    @jeremyniemiec7964 Год назад +1

    Great video, as an Industrial journeyman electrician in a factory, my residential experience is limited to what I've done in my own home. I love how you take time to explain things. One question I have on this video, when you're running the wire to the outdoor gfci, is that older white shielded 12/2? I was expecting to see yellow.

    • @hugovargas7411
      @hugovargas7411 Год назад +1

      I’ve seen 12-2 that is white shielded my house was built in the mid 60s so I imagine they used it back in the day.

    • @davidmarquardt9034
      @davidmarquardt9034 2 месяца назад

      @@hugovargas7411 I've seen NM cable that had grey or black, but mostly white plastic outer sheath, depending on the manufacturer and the year. Of course the NEC requires they all be marked with indelible ink or be stamped with the gauge size and number of conductors. It wasn't until about 2002, I believe, that they started color-coding. White is 14ga, yellow 12ga, orange 10ga, and blue 8ga.

  • @DieselGeneratortraining
    @DieselGeneratortraining Год назад +1

    Happy new year 2023 from #PowerLearningChannel

  • @vince6829
    @vince6829 Год назад

    Nice, neat job. Thank you for sharing.

  • @jamesr8336
    @jamesr8336 Год назад

    The breaker would trip on too much current or too much heat

  • @aaron74
    @aaron74 Год назад

    Wow, that's some pretty sketchy makeshift stuff you're correcting. Look forward to seeing the next video.

    • @electricianron_New_Jersey
      @electricianron_New_Jersey  Год назад

      Wait till you see some of the basement!

    • @aaron74
      @aaron74 Год назад

      @@electricianron_New_Jersey This project should have come up for you at Halloween... the haunted spook house!

  • @carlcapello9956
    @carlcapello9956 Год назад

    Did you call the utility company to turn off the power to the house? How about any grounding rods to install on the side of the garage at 6ft down and 8ft apart with grounding wire to each rod and connecting to the panel box? You didn't show us so, I just thought I would mention it. Thanks for the video I enjoyed it very much.

    • @electricianron_New_Jersey
      @electricianron_New_Jersey  Год назад

      I haven't started the service upgrade yet but that'll get done when I do. As for calling the power company for a shutdown, here I do not have to do that. I cut it out myself at the start of the day and cut in after the new service is installed.

  • @cheeseman9967
    @cheeseman9967 Год назад

    I hope that Milwaukee Tools is a sponsor!!😂

  • @dennywires
    @dennywires Год назад +1

    Very nice safety updates and corrections made. great video brother. I would have duct sealed the outdoor gfci.

    • @electricianron_New_Jersey
      @electricianron_New_Jersey  Год назад +1

      I usually do use duct seal but I must've been out of it on this day. Around here when inspectors see it used outdoors they want to see the listing on the package to be sure it says FOR OUTDOOR USE. The stuff they sell at Home Depot is GB brand and is not rated for outdoor use.

    • @dennywires
      @dennywires Год назад

      @@electricianron_New_Jersey that's interesting never knew there's an indoor outdoor rating on duct seal. I've only ever used it for exterior purposes. I'll have to check that out next time I'm at depot or lowes

  • @theamerican7080
    @theamerican7080 Год назад

    I love electrical nightmare videos!

  • @ptso7580
    @ptso7580 Год назад

    If I was a betting man, I would bet that house has either, Zinsco or Stab-lok breakers still. And a few to many shared circuit. Keep up the good work. 👍

    • @electricianron_New_Jersey
      @electricianron_New_Jersey  Год назад

      That videos coming up soon. It’s actually an old Murray panel I believe. It’s also bootlegged and double tapped.

    • @ptso7580
      @ptso7580 Год назад

      @@electricianron_New_Jersey Ouch! Guess, Murray was that flavor of the month. Was the panel over filled and crunchie conductors? No. Don't say, I wanna see it, when the video is posted. 😊 👍

    • @electricianron_New_Jersey
      @electricianron_New_Jersey  Год назад

      @@ptso7580 I'm still waiting to hear from the customer for when they want to do the service. We're supposed to be doing a generator there too.

  • @Bob.W.
    @Bob.W. Год назад

    An electrical inspector once told me that he went to a home that had been "rewired" with lamp cord run behind wood paneling. 😂

  • @billyr9840
    @billyr9840 Год назад

    It's incredible what people will do when it comes to wiring not realizing how or have no clue that they are creating a future/present dangerous fire or life threatening hazard !
    Question, when you made that connection in that 4 × 4 junction box, is it required to have a equipment ground supplied directly to the box itself ?

    • @electricianron_New_Jersey
      @electricianron_New_Jersey  Год назад +2

      Yes, the code says anything that can become energized shall be bonded to the equipment grounding conductor.

  • @trailermonkey8687
    @trailermonkey8687 Год назад

    The sad thing is the existing owners (sellers) of the property probably paid for all that work but never really benefited from the improved safety aspect of this work!

    • @electricianron_New_Jersey
      @electricianron_New_Jersey  Год назад

      Unfortuneately, it was the homeowner that created this mess in the first place. Glad you enjoyed the video.

  • @jesses9553
    @jesses9553 Год назад

    Ron, I am installing an exterior outlet (and box). Would you recommend a watertight strain relief or the romex clamp used in your video? What should the hole size be (through the house, cement board siding)Flex duct or exterior caulking?

    • @electricianron_New_Jersey
      @electricianron_New_Jersey  Год назад

      Make the hole just large enough to fit the connector. Then continue hole with a 1/2” paddle bit. Plug it with duct seal and use silicone (not caulk) to seal it up. Silicone resists water.

  • @hanifmastoi1616
    @hanifmastoi1616 Год назад

    Nice view

  • @Nihilumbra
    @Nihilumbra Год назад

    Good work 👍. Why a hot on right side? Interested.
    I'm from Russia, sorry for my English 😎

  • @SG-zh5xd
    @SG-zh5xd Год назад

    Are you able to have exposed wire in the garage ?

  • @GreyGhost-r4z
    @GreyGhost-r4z Год назад

    Wow.

  • @davelavigne2133
    @davelavigne2133 Год назад

    I would run from this house. If the electric is this bad, I can only imagine the plumbing.

  • @johnc6343
    @johnc6343 Год назад

    Ron, any work Van you can recommend?

    • @electricianron_New_Jersey
      @electricianron_New_Jersey  Год назад

      Ford Transit 250 mid-roof

    • @johnc6343
      @johnc6343 Год назад

      @@electricianron_New_Jersey Tx brother, great work as always

    • @glasshalffull2930
      @glasshalffull2930 Год назад +1

      What a mess!!! Reminds me of my mother in laws place. Every visit to her place out of state was, ‘how many things can I fix before we have to leave.’ Kept me busy. Only recommendation would be a bead of caulking on the all weather box, but with a hole at the bottom. Driving rain will probably infiltrate the back connector.

  • @awarepenguin3376
    @awarepenguin3376 Год назад

    This house seems like a nightmare to work on.

  • @adassociates8235
    @adassociates8235 Год назад

    they are so lucky that whole neighbors did not burn down as their electricity mess😅😅😅😅😅😅😅😅😅😅

  • @Sparky-ww5re
    @Sparky-ww5re Год назад +1

    That house is definitely in rough shape with the wiring. Possibly at one time occupied by a low income family that tool whatever shortcuts were needed to save every penny they could while still remaining functional?? I get it, with inflation at levels many folks have never seen in their lifetime and salaries not always keeping up, many family budgets are being stretched to the breaking point, but when it comes to electricity, that's not the place you should be cheaping out on.

    • @electricianron_New_Jersey
      @electricianron_New_Jersey  Год назад

      These homeowners owned a gas station and this is a pretty nice neighborhood too. I think the man of the house just liked tinkering with electricity.

  • @GreyGhost-r4z
    @GreyGhost-r4z Год назад

    I think DIY’ers struggled to learn how to do good wiring. RUclips was invented in April of 2005. Before that, you struggled to find info on how to do any repair. Remember those Time Life Book series ? How to fix your home, I remember trying to find electrical code and how to look things up. It was difficult.
    I also think homeowners are probably embarrassed to call a pro to fix their messups.

    • @electricianron_New_Jersey
      @electricianron_New_Jersey  Год назад

      If they can find someone who knows how to make the proper repair. Here in NJ it is unlawful to hire anyone who doesn’t carry a valid electrical license.

  • @carljones3515
    @carljones3515 Год назад

    ❤️❤️❤️❤️👍😁👍👍