Please 🙏 Can u help calculate how much to spend for solar panels energy…. 7 AC 1.5 HP 130 led pot light 7 water boiler 4 TV 1 big fridge 2 deep freezer 1 2HP Sumo
This is basically a deye inverter...it just means it's a high voltage inverter... which takes battery input from 180v to 800v dc..so batteries are in series nor parallel like LV systems
This is definitely for industrial use. How on earth can you have 800v battery in your house. And i also guess it is high frequency, there is no way a low frequency 50kw will be that small. Kudos, but 10kw X 5 will be better anyday than this single 50kw.
@abdulwahab5994 Because multiple inverters uses multiple set of batteries in low voltage(48v) configuration. Unlike this that uses 800v battery system. In Multiple inverters, you could put it in a configuration to shut down some inverter when the load is minimal and they will pick up when there is more load demand. Using multiple 50kw for large industries is understandable, but Using a single 50kw inverter for residential is really not worth it, for safety and reliability concerns. Using 5 10kw inverter is more reliable than using 1 50kw inverter.
@savageolatunde6731 when u think of efficiency... you will understand why...at 800v only 10amps is 8000 watts...to pull that same amount of wattage from 48volts is how many amps? That's why most manufacturers are now going high voltage. Very soon LV will become like lead acid . And idle consumption on these inverters are really good. Mppts too are very good. U shd really chk dem out... u won't go back to LV. It will start every equipment cus of the efficiency
@jojoowumanmensah1733 I get your point about efficiency but having to put together 66pcs of 12v battery to make 800v is a whole lot for residential use. This inverter is best suited for industrial environment that is power hungary, and there are safety factors considered.
They also have 110 kw
Is single phase??
I really want to learn from you, how I wish
Please 🙏
Can u help calculate how much to spend for solar panels energy….
7 AC 1.5 HP
130 led pot light
7 water boiler
4 TV
1 big fridge
2 deep freezer
1 2HP Sumo
You might spend 30-35m
Omo na around 50 to 60m if you wan dey comfortable oh. No be beans.
At 1" 800v battery. Can you explain further?
This is basically a deye inverter...it just means it's a high voltage inverter... which takes battery input from 180v to 800v dc..so batteries are in series nor parallel like LV systems
Go for growatt
This is definitely for industrial use. How on earth can you have 800v battery in your house.
And i also guess it is high frequency, there is no way a low frequency 50kw will be that small.
Kudos, but 10kw X 5 will be better anyday than this single 50kw.
How is using multiple inverters better than using just one?
I wish I could show mine to you... it even simple...just one rack of batteries...12 batteries
@abdulwahab5994
Because multiple inverters uses multiple set of batteries in low voltage(48v) configuration. Unlike this that uses 800v battery system.
In Multiple inverters, you could put it in a configuration to shut down some inverter when the load is minimal and they will pick up when there is more load demand.
Using multiple 50kw for large industries is understandable, but Using a single 50kw inverter for residential is really not worth it, for safety and reliability concerns.
Using 5 10kw inverter is more reliable than using 1 50kw inverter.
@savageolatunde6731 when u think of efficiency... you will understand why...at 800v only 10amps is 8000 watts...to pull that same amount of wattage from 48volts is how many amps? That's why most manufacturers are now going high voltage. Very soon LV will become like lead acid . And idle consumption on these inverters are really good. Mppts too are very good. U shd really chk dem out... u won't go back to LV. It will start every equipment cus of the efficiency
@jojoowumanmensah1733
I get your point about efficiency but having to put together 66pcs of 12v battery to make 800v is a whole lot for residential use.
This inverter is best suited for industrial environment that is power hungary, and there are safety factors considered.