Connect solar panels in series or in parallel | Electric Online

Поделиться
HTML-код
  • Опубликовано: 5 ноя 2024

Комментарии • 313

  • @zafarudaasofficial
    @zafarudaasofficial 6 месяцев назад +2

    Nice♥♥♥

  • @ETEA-by-MCQs
    @ETEA-by-MCQs 2 месяца назад

    sir ,which one is best for past changing of 12 v battery Parallel or seres?

    • @ElectricOnline
      @ElectricOnline  2 месяца назад

      Depend on Condition mppt controller voltage range

    • @ETEA-by-MCQs
      @ETEA-by-MCQs 2 месяца назад

      @@ElectricOnline sir I don't have any controller 😕

    • @ElectricOnline
      @ElectricOnline  2 месяца назад

      Ok to phir ap ne direct connection kr ke Kya chiz chalana Cha rahay hain taqay main os hisab se ap ko guide karu

    • @ETEA-by-MCQs
      @ETEA-by-MCQs 2 месяца назад

      @@ElectricOnline 12 volt battery charge karna hy , I have 150w 2 panels

  • @muhammadmoez2861
    @muhammadmoez2861 2 месяца назад +1

    Mere pas 1000VA/660watt ka homage ups ha usk sth PWM 50A mene lagaya hwa 3 plates 180watt k sth mere pas peak time me 13 AmP show hoty PwM me kya ye sahi ha

    • @ElectricOnline
      @ElectricOnline  2 месяца назад

      13 amp pwm ke lehaz se to thek han agr mppt ho to wo ap ko taqreeban 20 se 25 taq de sakta hai 3 panel ke

  • @khmgaming2662
    @khmgaming2662 3 месяца назад +1

    Ager 2 solar 150w k parallel connection se 100ah ki battery direct charge kre to koi masla hoga? Bina controlar k?

    • @ElectricOnline
      @ElectricOnline  3 месяца назад

      G kr saktay hain koi problem nahi hai han bs over charge na ho ye khyal karna

    • @ETEA-by-MCQs
      @ETEA-by-MCQs 2 месяца назад

      ​@@ElectricOnlineagar seres me direct 100ah battery charge par lagaye to koi problem kryga?

  • @shoaibkiller6512
    @shoaibkiller6512 2 месяца назад

    Sir mera mppt 95volt max and 70amp he me 2 panels lagana chata ho 585 jinko series acha rahe ga ya parrallell

  • @ranashahzad9617
    @ranashahzad9617 2 месяца назад

    Sir i have two batteries of 17plates of Osaka.i have four solder plates of 150 Watts.i have soler control of 50 umper.i want to charge batteries through plates.pls tell me best connection series or parallel

    • @ElectricOnline
      @ElectricOnline  2 месяца назад

      Charge controller Kon sa hai
      Ya agr inverter hai to wo Kon sa hai

  • @gharori
    @gharori Месяц назад

    10 solar panles hain 585 series karon ya paralel .max solar charge controler 450 watt

  • @Ehsanvirgo
    @Ehsanvirgo 2 месяца назад

    aoa, I have simtek 60A ppt max 2000W PV power and 24v 2000VA/1500Watt inverter. Kia ap bata sakte hain is pe 585 a 575 k kitne panel lagen ge or series me ya parallel?

    • @ElectricOnline
      @ElectricOnline  2 месяца назад +1

      Signal battery ke sath 585w ke 2 panel Laga saktay hain parallel kr ke
      Or dobble battery ke sath 4 panel Laga saktay hain 2/2 ki series bana kr

    • @umarkhalid5188
      @umarkhalid5188 2 месяца назад

      کیا 4 کی سیریز اکٹھی بنائی جاسکتی ہے یا دو دو دو بیٹریوں والا یو پی ایس ہے اور سنکو کا ایم پی پی ٹی لگایا ہوا ہے

  • @mrhamzagamer
    @mrhamzagamer 2 месяца назад

    Parallel my ampere Kam Milty ha Kya MPPT KY sath ya same series connection jitny hi milty ha??

  • @bismillahechosound1457
    @bismillahechosound1457 2 месяца назад

    Mere paas 2 battery hai or 2 solar 200 watt ke or charge controller hai chota wala kya main battery ko 24 kardu to mere ac dc fan karab to nahi honge inme 24 v bardashst karne ka mamla ha??

    • @ElectricOnline
      @ElectricOnline  2 месяца назад

      Nahi 24 nahi Karna DC fan 12v hi bardasht kr saktay hain

  • @tanveertariq1
    @tanveertariq1 3 месяца назад

    Sir , total 12 penals 580 watt bificial hain.. 6 uper mamti pr jin pr shadi nai ata.6 neechy chat pr jin pr subah 6 bjy se 9 bjy tk shada rehta hai or kam hota jata hai. Filhal 12 penals hi aik string series main haim. Inverter 1000 volt supported hai 32 A. Aap kia mshwra dain gy. Series main lgi rahain ya better performance k liye kuch change krna chahaiye?inveter ki starting voltage 190v hai.

    • @ElectricOnline
      @ElectricOnline  3 месяца назад +1

      Acha inverter ki starting voltage range Kya hai mtlb mppt kitnay volt se start hota hai ????

    • @tanveertariq1
      @tanveertariq1 3 месяца назад

      @@ElectricOnline sir 190 ya 180 start range hai

  • @kashifkpk5076
    @kashifkpk5076 4 месяца назад

    Meray pass inverex 1.2 veyron II hain aur 4 panels hain 340 k ,tou ye series may lagayn gay ya parallel may

  • @qaisarkhanbaloch
    @qaisarkhanbaloch 4 месяца назад

    Inverex aerox 5.2kw
    Imax 18Amp
    Vmax 360v - 450v maximum
    8 panels 580w ( jinko N Type) single string mn lagai hn. Best performance krnay k ly kia krna hoga ta k maximum amp volts or 5200 watts ki setting ho skay, panel k qty 10/12 ho jai 2 strings watts,amp,volt ? Thanks

    • @ElectricOnline
      @ElectricOnline  4 месяца назад

      Matlab ap 2/2 ki steeng bana Cha rahay hain????

    • @qaisarkhanbaloch
      @qaisarkhanbaloch 4 месяца назад

      Yes

    • @qaisarkhanbaloch
      @qaisarkhanbaloch 4 месяца назад

      2 strings bn Jain oor load achay say manage ho jai

    • @ElectricOnline
      @ElectricOnline  4 месяца назад

      G bn sakti hai 2/2 ki string 4 serias main ek karain or 4 serias main ek kr ke dono ko apis main parallel kr dain or phir inverter ke sath lagain

    • @qaisarkhanbaloch
      @qaisarkhanbaloch 4 месяца назад

      4 ki 2 strings se volte 200 se down ho Jain g oor amp 24
      Jab k limit 18 h
      Setting aisi ho k voltage maximum hn oor single string ki nisbat benefit ziada h

  • @qamarnisar043
    @qamarnisar043 4 месяца назад

    Sir 12 volt DC setup hy maira. 585 watt ki plate hy. 2 tall tubular battery hain. Simteck charge controller hy 100 amp wala. Aik aur plate attached krni hy 585 watt ki. Series ma lagun ya parallel ma. All load is dc

    • @ElectricOnline
      @ElectricOnline  4 месяца назад

      Parallel main Lage ge

    • @qamarnisar043
      @qamarnisar043 4 месяца назад

      @@ElectricOnline amp 17 se ziada nai ho Jaen gy plz

    • @qamarnisar043
      @qamarnisar043 4 месяца назад

      @@ElectricOnline max input amp 12 volt py 17 hy

  • @ViralPakistan47
    @ViralPakistan47 6 месяцев назад +1

    AOA Bhai mary pas Homage ka 1214 UPS Inverter ha 12V vala us k sath 585W k Longi k 2 Pannel kya Parallel main lgau ya series main kindly bta dain Jazak Allah

    • @ElectricOnline
      @ElectricOnline  6 месяцев назад

      Is ki maximum pv range 100v DC hai ap series main laga lain

  • @muhammadzarar7420
    @muhammadzarar7420 5 месяцев назад

    Bhai Longi k 2 585 watt k panels hain or paktech k 70amp wala mppt ha, connection series m lgain ya parallel m?

    • @ElectricOnline
      @ElectricOnline  5 месяцев назад

      Parallel karain kiun ke 90v DC maximum range ho ge controller ki to 2 panel ke Voltage bhi taqreeban 90v hi banay gay to ap is ko parallel main lagain

    • @Nawabasimjaved
      @Nawabasimjaved 4 месяца назад

      @@ElectricOnlineparallal lgany se volts zaya nhi hojaengy? Or bhai ye bta dain k parral behtr hota h loud chlany k liye ya series agar 90vdc ho ise zyda na ho nd 585 ki 2 plates hn to??

  • @Nawabasimjaved
    @Nawabasimjaved 4 месяца назад

    Assalm o alikum meny crown 1.2 kwa ka inverter lia hai jiski pv range maximum 80vdc hai. Or mere pas jinko Double glass 585 wat ki 2 plates hn . Ab mujhse galti ye hui k pv range km wala inverter lelia isky conection to parallal main kronga taky pannals k pv oper na jae 80 k ( question ye hai k parralal krny se over all solar system k performnce main ya loud chlany main farak pry ga??

    • @ElectricOnline
      @ElectricOnline  4 месяца назад +1

      Walaikum salam
      Nahi koi khas fark nahi pare ga ab kiun ke pv range ke andar reh kr hi connection Karna hai to is liye dono panel ke connection parallel hi karain baki is ka charge controller Jo Laga hai wo mppt hai Kya ????

    • @Nawabasimjaved
      @Nawabasimjaved 4 месяца назад

      @@ElectricOnline charge controller 60A ka hai. Actully inverter ke body pe max pv 80Vdc likha hai crown ki official website pe 100VDC likha ha.
      Ap kindly check kr k btyen Crown xavier 1.2 kwa ki detail or btyen kya main isy series main lga skta hn mere pas 580 wali plates hn jinko n type bificial 585 nhe 580 wali hn

  • @WaqasMehmood0345
    @WaqasMehmood0345 2 месяца назад

    Sir meray pass 585 12 plates hey jinko or invi 7 kw hey .. series or parellel?? 283,ya 287 isa ziada Volts nae ja rahy tak volt aty … 2 inverters ac chalty lakin refrigerator nahi chaltaaa !!! Even pehly bhi chala kay daikha phir bhi nae

    • @ElectricOnline
      @ElectricOnline  2 месяца назад

      7 kw ke Liye to serious connection hi best rahay ga or agr inverter ac off ho to Kya phir bhi nahi chalta refrigerator????

  • @m.naeemshuaib4387
    @m.naeemshuaib4387 3 месяца назад

    Aslam o alskum sir . Meray inverter ki Max pv input voltage 55VDC hai aut main na 605 watt Ka 1 panel laga howa hai .kya main 2 panel laga sakta hoon

  • @ShakeelAhmed.786
    @ShakeelAhmed.786 4 месяца назад

    Bhai 575watts ke 2panels hai and 150 watts k 2panels hia parallel me sahi rhe ge ya series me

    • @ElectricOnline
      @ElectricOnline  4 месяца назад

      575w ke 2 parallel kr ke 150w ke dono series kr ke phir in ko apis main parallel kr ke Laga lain

  • @hamidmalik3722
    @hamidmalik3722 4 месяца назад

    A.a
    Bhai me ne desi inverter bnwaya he... Or 9 plates hen Canadian 575 watts... Inverter ke display pr input volta 230 show hote hen... Jbke calculations ke mtabiq 375 tk aane chaye 9 plates ke... To kya inverter chota he ya 230 e aate hen 9 plates ke?

    • @ElectricOnline
      @ElectricOnline  4 месяца назад

      G 375 hi anay chiye inverter chota hai is liye

    • @HKTechnist
      @HKTechnist 4 месяца назад

      Bhai 230 hi ate ha inverter k output. 375 agr agaye to pir to allah hi hafiz. 375 ki aurat may step down lagana prta ha

    • @ElectricOnline
      @ElectricOnline  4 месяца назад

      Janab 575w ke 9 panel hain ek panel ke open circuit voltage 45 se 48 atay hain os hisab se 405 volt bantay hain ap Zara hisab kr lain or agr wire losses Mila lo to 375 to paka anay chiye

    • @HKTechnist
      @HKTechnist 4 месяца назад

      ​@@ElectricOnlinesir my ne inverter ki output bataya ha. Usne input ka pucha ha. Inverter display p mostly ouput hi show hote ha na k input

    • @ElectricOnline
      @ElectricOnline  4 месяца назад

      G g bilkul han han ap ki bat thek hai buhat mazrat main ne note nahi kia g ap thek keh rahay hain inverter input to 230 hi ay ge buhat shukria JazakAllah ❤️

  • @khosorehman1288
    @khosorehman1288 4 месяца назад

    Bhai mujhe answer krna lazmi
    Mere pas inverex ka axpert vm 2.2kv ka inventer he solar panel 580 ke 3 he bettery abhe porani he almost dead iski pv volt range 80 say 102 he solar ke 580 ke 3no parlel me he ab issue ye jo solar say wire neche arhi he wo 4mm ke kia me solar ko series me concet kr sakta hon

    • @ElectricOnline
      @ElectricOnline  4 месяца назад

      G 2 ko series main kr saktay or 3 wale ko Sath parallel kr ke Laga lain or dusra ye ke wire ap ne buhat patli lagai hai Kam as kam 6 se 10mm lagain baki inshallah acha response de ga

  • @1minuteshoww
    @1minuteshoww 4 месяца назад +1

    Homage 2414 1800 watt ka invertor ka or 3 Canadian 585 watt panel lgae hajn parallel m. Lakin output max 550 watt mil ri h,plz solution btaen,kia series m lgy ga?

    • @ElectricOnline
      @ElectricOnline  4 месяца назад

      Is ki right side pr Ek steaker Laga ho ga ap os ki pic send kr dain Zara mujy main ap ko mukamal detail de deta hun Instagram pr send kr dain
      Instagram I'd
      ElectricOnline786

    • @Ksvedioo9902
      @Ksvedioo9902 3 месяца назад

      mery pas b yahi ha series and parrallel misk kro dano

    • @1minuteshoww
      @1minuteshoww 3 месяца назад

      @@Ksvedioo9902 smj ni ae... detail btana kindly

  • @jihanShah7
    @jihanShah7 2 дня назад

    20 panel 580 wat invt ka inverter 11 15 killwat ka 10 hp ki moter
    Please guide kase connection kru series ya parralel

  • @ranafarman8631
    @ranafarman8631 3 месяца назад

    Aoa
    Sir mery pas 585 ki 2 palt hain or mppt pak tech ka hai jo 15 se 85 k load pr hai or aik invater hai 2000w ka frige k liye musla ye hai jb main frige or air cooler chalata hon to vltge over hojate hain or system band hojata hai

    • @ElectricOnline
      @ElectricOnline  3 месяца назад

      Voltage over kasay ho jatay hain ?
      Main ap ki bat samjha nahi !
      Solar ke voltage ki bat kr rahay hain ap ? Ya mppt controller ke ?

  • @funandmasti5930
    @funandmasti5930 3 месяца назад

    aoa bhai mere pas 2 jinko n type 585 k panels aur 180amp ki aik battery hai mppt 60amp ka hai connection series me Karen ya parallel me please guide me bro

  • @rizwantanoli7789
    @rizwantanoli7789 5 месяцев назад

    Assalamu alaikum
    Sir merey pas 165 ki 1
    180 ki 1 plate
    Ab mein 580 watt ki 1 plate milana kr system banana chahta hu
    Kya ye theek rahega
    Mujhey 1fridg 2fan 2 light use krni hein

    • @ElectricOnline
      @ElectricOnline  5 месяцев назад

      G thek hai
      But Frigh chalany ke Liye ap ko inverter ki tarf Jana parna hai kiun ke Frigh ka starting tark ziada hota hai

  • @AmanUllah-xf3dq
    @AmanUllah-xf3dq 3 месяца назад

    As Salam alaikum sir
    Mere pass ziewnic pv2500 hain..
    Ek Battery Phoenix TX1800 _ 185 Amp...
    4 penal hain 545 wat...
    Plz eski connection karne k tarqa kar batade k series mai kardo ya peralal....?????

    • @ElectricOnline
      @ElectricOnline  3 месяца назад

      Is ki Pv input 430 VDC hai
      Ap tamam panel ko serias kr ke lagain

  • @searidder7571
    @searidder7571 4 месяца назад

    Salam
    Mere pass longi k 3 panels hain 550 watt k aur 2 batteries hain exide hp 275 aur fronus ka inverter hain 3000va 2018 model jis ka solar charging mode hai
    Rated current 50a
    System voltage 24vdc
    Opening voltage range 30 32 vdc solar voltage 80vdc connection parallel hai but batteries backup nhi dy rhi hain rat ko waja kiya ho gi ?

    • @ElectricOnline
      @ElectricOnline  4 месяца назад

      Battery ke hisab se panel Kam hain is liye backup nahi mil raha Kam as kam 6 panel hona zruri hain

    • @searidder7571
      @searidder7571 4 месяца назад

      @@ElectricOnline bhai ye inverter maximum 4 panels ko support krta hai & batteries full ho jati hain din k time but wapda se full nhi hoti hain rat ko 8 se 11 baje tak humri light hoti hain phr b full nhi hoti hain

    • @ElectricOnline
      @ElectricOnline  4 месяца назад

      G is battery ko ap wapda se charge bhi na karo kiun ke ye acha Bhala bijli ke unit Le ge bari battery hai is liye is ko ap solar se charge Karwa lain agr inverter spot nahi kr raha 4 panel se ziada to is ke Sath mppt controller Laga kr phir is ko charge karway

  • @muhammadkhalid9317
    @muhammadkhalid9317 Месяц назад

    Sir mere pas 4.2 ka inverter pv 6200 hai volt range 450vdc hai kia mein 550 wat ke 12 panel laga sakta hun us ka tariqa 27a wala mppt singal hai

    • @ElectricOnline
      @ElectricOnline  Месяц назад

      6 / 6 ki series bana kr Laga Lain

    • @muhammadkhalid9317
      @muhammadkhalid9317 Месяц назад

      @@ElectricOnline sir jab se 6 6 series bna ker Laga I Hein inverter fluctuation Bhat ker Raha hai ik dam 4000 wat se 800 Watt pr a jata hai phir niche se 4000 tak jata hai phir 800 900 what pr a JATA hai kerta Sirf net metering pr hai wapda off pr 4000 wat satabal rehta hai plz is ka Hal?

    • @ElectricOnline
      @ElectricOnline  Месяц назад

      Ye ap load ke sath chek kr rahay hain Kya ?

    • @muhammadkhalid9317
      @muhammadkhalid9317 Месяц назад

      @@ElectricOnline NAHI sir jab net metering on ho us waqt

    • @muhammadkhalid9317
      @muhammadkhalid9317 Месяц назад

      Agar wapda off ker dun to phr fluctuation NAHI hoti

  • @waqaashussain6363
    @waqaashussain6363 2 месяца назад

    Sir mera pas 150 wat k 5 pannel han
    Aik batry ha 100
    Inverter ha
    12v Dc to Ac 2500w maximum
    Controler ha
    50A . 12v.24v.48v
    Ma na parallel connection kia ha as pa 3 ceiling fan chalta hn agr aur fan chalain tu trip hona shuru ho jata ha

    • @ElectricOnline
      @ElectricOnline  2 месяца назад

      Jo trip kr raha hai wo ap ke inverter main problem lag Rahi hai baki connection thek hain parallel main

    • @waqaashussain6363
      @waqaashussain6363 2 месяца назад

      Sir as pa maximum load 3 fan he chala skta hn? Ap k hisab sa 5 panel pa kitna load chalaya ja skta ha
      Series connection krna sa zayada load dala ja skta ha​@@ElectricOnline

    • @ElectricOnline
      @ElectricOnline  2 месяца назад

      Taqreeban 4 fan chal saktay hain or Kuch lighta vegera
      Jo inverter ap ke pass ye local hotay Jo likha hai wo hotay nahi hain is liye agr ups hai ap ke pass to os pr 4 fan chal jay gay solar ko mppt controller Laga kr

    • @waqaashussain6363
      @waqaashussain6363 2 месяца назад

      @@ElectricOnline bohat shukrya sir g❤️❤️

  • @MadniYaqoob-s4t
    @MadniYaqoob-s4t 8 дней назад

    6 panel 575w 4 panel 600w JA Solar
    Rated Power: 600(/1
    Nominal operating voltage: 360VDC MPPT Voltage Rang: 60-450VDC
    Mar Solar Voltage/VC):500VDC

  • @SaqibBaba-e9d
    @SaqibBaba-e9d 2 месяца назад

    Mere pas 280 watt k 4 panel or 180 watt ka 1 panel he.mppt energy 70 amp ka he.abi sb paralel me hen.lkn battry boht jaldi khatam ho jati he.kuch mashwara de den bhai.

    • @ElectricOnline
      @ElectricOnline  2 месяца назад

      Ap 2/2 ki series bana lain or Jo 180w wala hai os ko parallel kr ke direct Laga dain

  • @amirshah2021
    @amirshah2021 4 месяца назад

    dear brother. assalamualaikum mere paas 180 watts k 4 panels hein. unko main ne parallel kya he lekin 48 volts wale charge controller pr 6 ampares se zyada nahi jaata. best regards

    • @ElectricOnline
      @ElectricOnline  4 месяца назад

      6 amp to buhat Kam de raha hai panel chek karain upper se wire to nahi khrab !!!!!

  • @zelyshah3450
    @zelyshah3450 2 месяца назад

    Sir mery pas 2 panel han 580 watt kay ik mppt ha 70Am ka or ik ups ha 750 wtt ka in ka canetion ko sa karon parallel ya series main plz rehnmai farma dain

    • @ElectricOnline
      @ElectricOnline  2 месяца назад

      Ap parallel connection karain

    • @zelyshah3450
      @zelyshah3450 2 месяца назад

      @@ElectricOnline or sir bettry b ha 180 ki wo btana bhol gya tha

    • @ElectricOnline
      @ElectricOnline  2 месяца назад

      G g battery bhi aram se charge ho ge

    • @zelyshah3450
      @zelyshah3450 2 месяца назад

      @@ElectricOnline g bohat shukria sir

  • @Hafizamanshahzad
    @Hafizamanshahzad 3 месяца назад

    Mery pas 180 watt ky 6 penal hain kia men sereis men lga sakta hon mppt faisal ka hai 65 amp

    • @ElectricOnline
      @ElectricOnline  3 месяца назад

      Nahi sub serias main nahi Laga saktay 3 / 3 ki serias bana kr Laga dain

  • @HafizAminBirds
    @HafizAminBirds 2 месяца назад +1

    جزاک اللہ خیر. میرے پاس دو پلیٹ 575 امپءر کی ھیں. Mppt 70.a. Energy. کا لگانا چاہتا ہوں... ؟ سولر پلیٹس کے کنکشن سیریس ھو نے چاھیءیں.. یا پیرلل میں. رہنمائی فرمائیں 1000واٹ کے یو پی ایس کے ساتہ لگانی ھیں . شکریہ.

    • @ElectricOnline
      @ElectricOnline  2 месяца назад +1

      Parallel connection karain wo thek rahay ga

    • @jasimabbas5515
      @jasimabbas5515 14 дней назад

      Sir mery pass 2 penal 580w k hn ..mppt 70 amper ka h .pv input rang .30 v - 100v ...is k conintion series me Karen ya parller me??????

    • @ElectricOnline
      @ElectricOnline  14 дней назад

      Parallel kr lain behtr hai

  • @happyprince583
    @happyprince583 3 месяца назад

    sir kindly rep kijiye ga...
    mere pass 4 panel hain 2 2 ki series kese bnate hain...aur kya ye 100amp k mppt k sath lag jayen gay?

    • @ElectricOnline
      @ElectricOnline  3 месяца назад

      Serias banane ke Liye ek panel ki + ko dusray wale panel ki - ke sath jor dain to ye 2 panel ki ek serias bn jay ge or phir esi tarhan agay 2 panel ki bhi asay hi Serias bana lain or phir Jo +/- 2/2 panel ki nikle hain os ki + ko + ke sath or - ko - ke sath Jo dain is tarhan 2/2 ki serias bn jay ge

    • @happyprince583
      @happyprince583 3 месяца назад

      @@ElectricOnline G bhtt shukriya apka...sath 2 battrry lagay gin?

    • @ElectricOnline
      @ElectricOnline  3 месяца назад

      G lag jay ge 2 battery bhi parallel kr ke lagana
      + Ko + ke sath or - ko - ke Sath

    • @happyprince583
      @happyprince583 3 месяца назад

      @@ElectricOnline Sir apla number mil skta? aur ap lahore se belong krte ya kisi aur city se?

    • @ElectricOnline
      @ElectricOnline  3 месяца назад

      Ap Instagram pr rabta kr Le
      Instagram I'd 👇
      ElectricOnline786
      Nahi sir Rawalpindi

  • @EthanAlex-t1m
    @EthanAlex-t1m 16 дней назад

    Sir 6200 W pv pr 585w ke kitny panel lag sakty ha

  • @talhamahmood3822
    @talhamahmood3822 4 месяца назад

    Asslam-O-Alaikum!
    Mohtram, m ne 4 solar panels 150w 2+2 series me lgayay hain. M ne PowMr Mppt Solar Charge Controller 60A (imported) lgaya hai.
    Ab m Longi Himo x6 k 2 panels 575w add krna chahta hoon.
    Connections krne me meri help kre.

    • @ElectricOnline
      @ElectricOnline  4 месяца назад

      Mppt ki pv voltage range Kya hai maximum?????

    • @ElectricOnline
      @ElectricOnline  4 месяца назад

      Mppt ki pv voltage range Kya hai maximum?????

  • @zeeshanshabbir4018
    @zeeshanshabbir4018 4 месяца назад

    AOA bhai, Mere pas 2 580watt ki jinko N type bificial plates hain or 100amp Simtek Hybrid MPPT jiski range 1800watt/170volt hai on 12v system main, 1 panel k volts 50 or amp 13 or battery meri 145amp daewoo lagai hoi, mny 2no plates filhal series main connect ki hain bcz 170v range kafi zaida hai mppt ki , mera question yeh hai series or parallel ka faida or nuqsan kia hai, battery charging k liye amp zaida zroorat ya volts, isi tarha load chalany k liye amp zaida zroorat ya volts. reply kindly

    • @ElectricOnline
      @ElectricOnline  4 месяца назад +1

      Dekhay load ke Liye to amp or bolt dono ho apni apni jaga zrurrat hain or ap ne series main hi connection Kiya hain wo ziada behtr hai han ap panel 2 or add kr lain best ho jay ga inshAllah

  • @mrhamzagamer
    @mrhamzagamer 2 месяца назад

    Agar MPPT KY sath bhi parallel my connection kry to voltage same rhy gy our Ampere bhar Gye gy 585 watt 2 plates = 48Volt + 12*2=24 Ampere tu Mppt Kya boost kary ga

  • @maliksohailmuzaffar8420
    @maliksohailmuzaffar8420 4 месяца назад

    Aslam UnAlikum bahi paktech mppt hai 2 barri panel lagane hai conection konsa karo kay acha result aye sereies ya parller main plzzz help kar de

  • @Velog.Ashfaq
    @Velog.Ashfaq Месяц назад

    Sir Mary pass solar max ka 1.2 watt inverter he wo wapda pr chal rha he solar par nahe. 2 manth Sy. Please help. pv in put 86 volt .

    • @ElectricOnline
      @ElectricOnline  Месяц назад

      Panel se pv voltage thek arahay hain Kya

  • @adnankhan-u3b
    @adnankhan-u3b 2 месяца назад

    Sir mere pas 150watt ka 9 plates ha mana inverix 2.5kw inveter pe chala na ha sir kia tareka kar ha is

    • @ElectricOnline
      @ElectricOnline  2 месяца назад

      Inverex ka veron hai 2.5 kw ka ?
      Os ke Liye ap 3/3/3 ki series bana kr phir un ko parallel kr ke Laga lain

  • @ShahidKhan-z5n
    @ShahidKhan-z5n 3 месяца назад

    Bhai Mayray paas pehlay 4panel 440w walay thay to ussay takreeban 900w bijly inverter may batata tha ab mainay 4 panel 440w walay or ad kardiya hay series may he pehlay bhi series may hi thay inverter ki range 400v tak hay or abhi inverter may 320v tak jata hay par 1.5 kw say ziada bijli nahi banarAha hay yani bijli kam ban rahi hay kiya waja hosakti hay iski?

    • @ElectricOnline
      @ElectricOnline  3 месяца назад

      Acha sub se pehle to ap ye Jo load chek kar rahay ho ye Sara load Chala kr chek karo phir pta lagay ga or agr sub load Chala kr dek rahay ho phir bhi 1.5 se ziada nahi bana raha to ek Baar panel ko 2 steeing main kr ke dekh lain Yani ke 4/4 ki serias kr ke phir un ko parallel kr ke lagain inverter main or phir ap mujy batao ke Kya results de raha hai

    • @ShahidKhan-z5n
      @ShahidKhan-z5n 3 месяца назад

      @@ElectricOnline Theek hay bhai kal bataunga aap ko Aysay check kar k par aap apna number day daytay to call kar k batadayta

    • @ShahidKhan-z5n
      @ShahidKhan-z5n 3 месяца назад

      @@ElectricOnline Theek hay bhai kal aapko bataunga check kar k par aap apna number day daingay to aapko call kar k bata dayta

    • @ElectricOnline
      @ElectricOnline  3 месяца назад

      Ap Instagram pr rabta kr Le
      Instagram I'd ye hai 👇
      ElectricOnline786

    • @ShahidKhan-z5n
      @ShahidKhan-z5n 3 месяца назад

      @@ElectricOnline Assalam o alikum bhai aapnay 2 sting kar k aapas may parallel kar k daykh kar batanay ka kaha tha to maynay ab tak aysay hi kar k chora huwa hay to ismay volt abhi 165 say ooper nahi ja raha hay or amp 8 say ooper nahi ja rahay hain yaani takreeban bijli utni hi ban rahi hay ab bataeay k aysay hi 2 sting may hi rehnay du ya phr pooray ko 1 hi series may kardun

  • @sajidkhan-rg5je
    @sajidkhan-rg5je 4 месяца назад

    السلام علیکم سر۔ میرے پاس 10 پینل ہیں 6 پینل 565 اور 4 پینل 570 واٹ کے۔ اور inverex inverter 5.6 kw
    کا ہے۔ ان پینل کو series میں لگانا بہتر ہوگا یا parallel میں۔
    پلیز رہنمائی فرمائیں۔

    • @sajidkhan-rg5je
      @sajidkhan-rg5je 4 месяца назад

      ja کے پینل ہیں۔

    • @ElectricOnline
      @ElectricOnline  4 месяца назад

      Series main lagain in ko pv maximum voltage range kitne hai

  • @syedarshadali5067
    @syedarshadali5067 Месяц назад

    Mera Paas Stabimatic ka 1.5kv ka sollar invertor ha or phoenix 1800 tubular battery ha 585 volt k 2 solar panel laga hua ha jub dhoop hoti ha to kabhi kabhi 03 ka error ajata ha panel ko parallel ma lgaya hua ha please mashwara karde jazakallah.

    • @ElectricOnline
      @ElectricOnline  Месяц назад

      Panel to ap ne thek lagaya hai 03 ka error??????
      Ok main ap ko is ka batata hun

  • @shakirawan5154
    @shakirawan5154 4 месяца назад

    Sir mere pas VFD 7/11 hai, 555 watt k 16 panels hain, still 2 hp ki 2 submersible pumps nhi chal rahe, series main connection hai

    • @ElectricOnline
      @ElectricOnline  4 месяца назад

      Vfd ke pv voltage range Kya hai maximum wo Bata dain zara

  • @amjadhussainqazi5791
    @amjadhussainqazi5791 5 месяцев назад

    Aoa bhai mery pas homeage ka 12 volt ups 1000 watt 600 watt solar power k sath laga hua ha usky mn ny 330 watt aur 250 watt ki 2 plate lagai hue hn ab mn 2 bari plate 550 watt ki lagana chahta hn tu kia ups k sath mppt 100 amp wala lagaon ya inverter 1.6 kw ka aur choti platon ko bari k sath kaisy lagaon

    • @ElectricOnline
      @ElectricOnline  5 месяцев назад

      Mere khayal main mppt Laga Lain to wo ziada behtr rahay ga bari plate ko parallel kr dain or baki kitne plate hain ?

    • @amjadhussainqazi5791
      @amjadhussainqazi5791 5 месяцев назад

      @@ElectricOnline sir 2 plate 330 aur 250 watt ki

    • @ElectricOnline
      @ElectricOnline  5 месяцев назад

      In 2 ko apis main serias kr lain

  • @Salam-yg4io
    @Salam-yg4io 3 месяца назад

    Aoa, bhai mery pass 325 Watts k 4 panels hn, jis k volt 45.5 aur 9 ampair hn. Charge controler 70 amp aur 100 volt ka ha, connection kis tarah karo, please guid kar dy. DC system lagai ho ha, single batter 140 amp ki

    • @ElectricOnline
      @ElectricOnline  3 месяца назад

      2/2 ki serias bana kr lain best result mile ga inshAllah DC system bhi chale ga or ap ki battery bhi charge ho ge

    • @Salam-yg4io
      @Salam-yg4io 3 месяца назад

      Jazakallah bhai, Allah pak ap ko salamat rakhy.

  • @punjabweatherupdate
    @punjabweatherupdate 3 месяца назад

    Aso
    Bhi mara pk tec MPPt charge controller series mein run ni hota tha❤Mein nay technician ko dakha ic nay kha k parrael connection kro mein nay to samja k bakwass kh rha ha ❤❤❤❤laken jb parrrael connection kea to wo run ho gya ab wo batter ko 13Watt pr kut off krta ha series mein14.5 pr krta tha 13 pr b hmary battery theek charge ho ge k ni please reply phoneix 165ampha❤❤❤❤

    • @ElectricOnline
      @ElectricOnline  3 месяца назад

      G Thek kia ap ne series se hata kr parallel kr dia or dusra ye ke ap ki battery 13 pr bhi full charge ho ge

    • @punjabweatherupdate
      @punjabweatherupdate 3 месяца назад

      @@ElectricOnline Bhi aik RUclipsrs
      Say mein nay pocha ha ic nay btya tha k battery 14.volt pr full charge ho ge 13 pr full charge ni ho ge

  • @WhizHappyKids
    @WhizHappyKids 5 месяцев назад

    AOA mary pasy Homage ka 1214 Ups inverter ha mary pas longi k 585w k 2 panel hain or 180W k bhe 2 panel hain kya main in sb ko lga skta hun is inverter k sth ya nahi agr lga skta hun to kssy lagau kindly bta dain Jazak Allah

    • @ElectricOnline
      @ElectricOnline  5 месяцев назад +1

      Ap ka Jo inverter hai os ki maximum pv voltage range 100v DC hai or ap ke pass 585w ke 2 panel or 180w ke bhi 2 panel hain 585w ke open circuit voltage 45 taq hotay hain or 180w ke open circuit voltage 20 taq hotay hain ap 180w ke dono panel serias karo Jo ke 40 voltage ban jay gay or phir 585w Wale dono panel ko 180w ke sath parallel kr dain jis ki surat main total 85v DC ban jay gay or behtr result mil jay ga JazakAllah

    • @WhizHappyKids
      @WhizHappyKids 5 месяцев назад

      ​​@@ElectricOnlineBhai main na sirf 585W k 2 panel ko series main lgya tha us volts to aa rhy lakin AmP show ni ho rhy inverter pr

    • @ElectricOnline
      @ElectricOnline  5 месяцев назад

      Ap parallel kr ke chek karain kiun mujy lag raha hai series se voltage thore upper ja rahay hain

    • @WhizHappyKids
      @WhizHappyKids 5 месяцев назад

      ​@@ElectricOnlinethek ha bhai Jazak Allah

    • @WhizHappyKids
      @WhizHappyKids 5 месяцев назад

      @@ElectricOnline AOA bhai main na 585W k panel ko parallel main lgya or 180W k panel ko series main lga kr 585W k panel k ath parallel kr deya lakin inverter pr AMP 20 Any lg gy bs lakin jb main na sirf 585W k panel ko parallel main lga k ups k sth connect keya phir 41Amp any lg gy

  • @suhailrana6076
    @suhailrana6076 3 месяца назад

    sir maray pass local inverter 5 kva ka hay or 580 ki 6 plates hain in kay conection solar plate kaisay karain. Shukria

    • @ElectricOnline
      @ElectricOnline  3 месяца назад

      Local inverter ke pv open circuit voltage range Kya hai ???

  • @happyprince583
    @happyprince583 3 месяца назад

    sir mere pass 4 panel hain 585w k mn inko kis tarha mppt k sath attach kron?

    • @ElectricOnline
      @ElectricOnline  3 месяца назад

      Mppt ki voltage range Bata dain ??

    • @happyprince583
      @happyprince583 3 месяца назад

      @@ElectricOnline simtek 100amp vala hai aur voltage range 1500 hai 12v k liye aur 3000 24v k liye

    • @ElectricOnline
      @ElectricOnline  3 месяца назад

      Nahi nahi voltage range ka keh raha hun Jo pv open circuit voltage hotay hain wo

    • @happyprince583
      @happyprince583 3 месяца назад

      @@ElectricOnline sorry mn apki bat nai smja ...panel ki voltage range poch reahay hain ya kya cheez?

    • @ElectricOnline
      @ElectricOnline  3 месяца назад

      Panel ke nahi mppt controller ke max pv voltage range

  • @Velog.Ashfaq
    @Velog.Ashfaq Месяц назад

    Solar max 1.2 ka inverter.585 Watt ky 2 panel series me lagay he . Lakin inverter din ke wakat bhee wapda par chal rha he . Solar par nahi . Please . Setting bta Dan.

    • @ElectricOnline
      @ElectricOnline  Месяц назад

      Ap Koshish karain ke Apne solar system ke sath wapda Wala breaker lazmi Laga Lain din ke time wapda ko breaker se lazmi se off karain taqay kesi bhi kisam se wapda mix na ho

  • @hammadmughal7738
    @hammadmughal7738 2 месяца назад

    Sir mera pas 2 plate 180 wali ha aur 1 battery ha 100Ap wali ha aur sat 30amp wala controler b ha to connection kasa karo plz bataen

    • @ElectricOnline
      @ElectricOnline  2 месяца назад

      Dono panel ko parallel kr ke Laga dain

  • @Nawabasimjaved
    @Nawabasimjaved 4 месяца назад

    Or ye btayen k parral best rehta hai ya series pv range k ho parral krny ke disadvtgs kya hoty hn ??

    • @ElectricOnline
      @ElectricOnline  4 месяца назад

      Wo to pv range ke mutabik hai ke parallel ho ga ya Series wasay series main ye hai ke extra voltage zaya nahi jatay amp ki shakal main result mil jata hai

    • @Nawabasimjaved
      @Nawabasimjaved 4 месяца назад

      @@ElectricOnline ap kindly crown xavier 1.2 kwa ki detial net se dkhainkr btyen kya kli chances hn k series main2 plates 580 wali lg jaen
      Thankz

    • @Nawabasimjaved
      @Nawabasimjaved 4 месяца назад

      @@ElectricOnline ??

  • @fawadalisoomro1158
    @fawadalisoomro1158 29 дней назад

    Solar Inverter Mode:
    DC Input: 12VDC, 114A
    AC Output: 230VAC, 50/60Hz, 5.2A, 1Ф
    Solar Charger Mode:
    System Voltage: 12VDC
    Max. Solar Voltage (VOC): 102VDC MPPT Voltage range: 15 ~ 80VDC Max. MPPT Current: 50A. 7:17 Solar panel data sheet: Model Type
    HPSP-150P
    Rated Max Power(Pmax)
    150W
    Current at Pmax(Imp)
    8.63A
    17.5V
    Voltage at Pmax(Vmp)
    9.05A
    Short-Circuit Current(Isc)
    22.4V
    Open-Circuit Voltage(Voc)
    45+/-2°С
    Normal Operating Cell Temp(Tnoct). I have same 4 panels series or parallel kons connection best ha plz bata den

    • @ElectricOnline
      @ElectricOnline  28 дней назад

      Panel kitne wat ke hain ap ke pass

    • @fawadalisoomro1158
      @fawadalisoomro1158 28 дней назад

      Sir uper solar panel data sheet par likha howa 150w

    • @ElectricOnline
      @ElectricOnline  28 дней назад

      Ok 150 watt ke 4 panel hain to Ap sub ke sub serias main bhi laga saktay hain but Mera masheara ap ko ye hai ke ap 2/2 ki serias bana kr lagao

  • @mrhamzagamer
    @mrhamzagamer 2 месяца назад

    1. Bahi Agar 2 Solar Plates 585watt ky Series ya Parallel ky connection kary MPPT 70 Ampere (PV Range 100V) ky Sath tu kis my kitny Ampere mily gy DC series my our parellel my Peak Time my??
    2. Kya Parallel my MPPT ky sath Ampere Kam milty ha Series my tu Volt ko Ampere my convert kar deta MPPT Tu Parallel my kya hota

    • @ElectricOnline
      @ElectricOnline  2 месяца назад

      Series main extra volt amp main convert ho jatay hain mppt un ko convert kr deta hai jub ke parallel main extra volt zaya ho jatay hain mgr ye pwm charge controller ke sath Iada hota hai mppt main ye masla nahi hai

    • @mrhamzagamer
      @mrhamzagamer 2 месяца назад

      Parallel my ampere Kam Milty ha Kya MPPT KY sath ya same series connection jitny

  • @entertainmentplus00
    @entertainmentplus00 5 месяцев назад

    Sir mere pass 12 panels 585 ja k hai aur inverter 6kv pv 120- 420 hai kindly guid karein

  • @amanportfolio
    @amanportfolio 3 месяца назад

    MashAllah nice bro mn ny 585 watt k 2 lgye series mn pr charge control amp 1 plate jitny dy rha hai, shyed volt ka problem hu ga mn parallel test krta hn

    • @ElectricOnline
      @ElectricOnline  3 месяца назад

      Ap ne Series main lagay hain ????
      Or dusra ye ke ap ne Kon sa charge controller lagaya hai JazakAllah

    • @amanportfolio
      @amanportfolio 3 месяца назад

      @@ElectricOnline Bro parallel kiye ajj TU perfect hu gye... Charge controlar whi 4500 ka ju ata h common black... Volt zyadah hu rhy thy shyd

  • @arslannaseer3497
    @arslannaseer3497 3 месяца назад

    Asslam o Alaikum!
    Mery pass 3.2Kv ka inverter hy os ki max voltage range 102VDC hy. Os pr 6 plates lgi hoi hn 450Watt ki pr 850watt sy oper nahi jata kea vja hy?

    • @ElectricOnline
      @ElectricOnline  3 месяца назад

      Walaikum salam
      Max pv voltage range 102 hai to os hisab se ap 2/2 ki series bana kr Laga Lain 2/2/2 phir in ko apis main parallel kr dain

    • @arslannaseer3497
      @arslannaseer3497 3 месяца назад

      @@ElectricOnline axha thank you lakin Watt 900 sy oper keun nahi ja rhy jb k 2000 tak jany chahyn 6 plates k

    • @ElectricOnline
      @ElectricOnline  3 месяца назад

      Han 70% bhi nikalo to 2700 ka 2000w banta hai
      Acha ap ne abhi kasay lagay hoy hain panel ????

    • @arslannaseer3497
      @arslannaseer3497 3 месяца назад

      @@ElectricOnline 2,2 ki series bna kr parallel lgai hoi hn

    • @ElectricOnline
      @ElectricOnline  3 месяца назад

      2/2 ki serias banai hai acha phir to thek hai phir ap ko result milna chiye acha ap ek kaam karain mujy lag raha hai ke ap ke 2 / 3 panel work nahi kr rahay ap upper ja kr panel chek karain pehle

  • @Thesaqibsunlight
    @Thesaqibsunlight 5 месяцев назад

    Bhai mere pas 2 panel 100w yani 12v h hen.or 1 panel 540w yani 48v hen.pwm controller m kis trah laga sakta hun.

  • @dreamcattlefarm1741
    @dreamcattlefarm1741 2 месяца назад

    Crown 4 kv ka hy or ,6 plat lagani hy kese lagay.

  • @syedalirizwan3655
    @syedalirizwan3655 5 месяцев назад

    570 watt ky 10 panel hain inverter ki 60 sy 450 hai kya krin

    • @ElectricOnline
      @ElectricOnline  5 месяцев назад

      Ek panel ki open circuit voltage kitnay hain ?

  • @ashiqhussain-ys9qv
    @ashiqhussain-ys9qv 4 месяца назад

    Sir Mera pass 1.6 frouns ha aus per KITNA solar panel Laga ga

    • @ElectricOnline
      @ElectricOnline  4 месяца назад

      Os ke side pr Ek steekar Laga ho ga os main os ki pv range Bata dain or solar Kitna waat taq ka lag sakta hai ye bhi likha ho ga ap chek kr ke mujy batao phir main ap ko Bata deta hun

  • @ghanikapoor3092
    @ghanikapoor3092 4 месяца назад

    Mary pss trion modal 1200 watt 1000 vds 15 90 ups ha ma na peral ma 380 wat longi palt lagyi ha ab ma mazeed laga sakta hu

  • @shoaibsaleem9992
    @shoaibsaleem9992 5 месяцев назад

    Mere mere pass solar Max ka 1.5 word wala hai uski PV range 120 380 uske sath 550 wali 3 solar panel hai lekin Fir Bhi vah mppt charge controller on Nahin Hua iski kya vajah ho sakti hai

    • @ElectricOnline
      @ElectricOnline  5 месяцев назад

      Mppt ko trigger karwane ke Liye Kam as kam 150v dene ho gay tab is ka mppt on ho ga abhi ap ke pass 3 panel hain 1 panel ke volt 45 ho gay to os hisab se 135 banta hai ap ko 1 or panel lagana ho ga tab ja kr bat bane ge

  • @ShakeelAhmed.786
    @ShakeelAhmed.786 4 месяца назад

    Mppt 12vt 1000wat
    24vt 2000 watt me lg jae ge sare

  • @umarkhalid5188
    @umarkhalid5188 2 месяца назад

    میرے پاس580 کی چار پلیٹس ہیں
    یو پی ایس 1800 واٹ کا ہے مجھے کنکشن سیریز میں کرنے چاہیے یا پیرالل؟

    • @ElectricOnline
      @ElectricOnline  Месяц назад

      Charge controller Kon sa hai ap ke pass ?

  • @KiddoBrightTV
    @KiddoBrightTV 5 месяцев назад

    A O A bhai mary pas homage ka 1214 UPS inverter ha us k sath longi k 2 585W k panel install hain parallel main jo 41Amp da rhi hian lakin abi kl sa 1 masla aa rha k ups chlta chlta kudh bnd ho jata ha is ka issue ha ap bta dain Jazak Allah

    • @ElectricOnline
      @ElectricOnline  5 месяцев назад

      Acha battery ke tarminal chek kr lain loss to nahi hain

    • @ElectricOnline
      @ElectricOnline  5 месяцев назад

      Baki connection to ap ne thek kiye hoy hain mujy lag raha hai ya to battery tarminal loss hain
      Acha ek bat or battain ke load Kya Kya Chala rahay Kai ups se ziada Wala load to nahi chal raha

    • @KiddoBrightTV
      @KiddoBrightTV 5 месяцев назад

      @@ElectricOnline 2 AC/DC fan 1 DC cooler supply pr

    • @KiddoBrightTV
      @KiddoBrightTV 5 месяцев назад

      @@ElectricOnline battery to charge ho rhi ha lakin ups power bnd kr data ha phir bs battery charge hoti rhti ha

    • @ElectricOnline
      @ElectricOnline  5 месяцев назад

      Load to thek hai koi ziada nahi hai phir ups ki output wali side ka issues lag raha hai acha ups bilkul band ho jata hai ya sirf load off kr deta hai

  • @shahidhanif6165
    @shahidhanif6165 3 месяца назад

    Asslam o alaikum
    میرے پاس 2 عدد سولر پلیٹ 585 واٹ ولی jinco کی ھیں ان کا کنکشن کیسے کریں 1000 واٹ کا mppt solar inverter home age کا ھے 7:23

  • @Hafizamanshahzad
    @Hafizamanshahzad 3 месяца назад

    Bhai mery pas 180 watt ky 6 penal hain or men series men lga sakta hon

    • @ElectricOnline
      @ElectricOnline  3 месяца назад

      Kon sa inverter hai
      Ya Kon sa controller hai
      Or os ke open circuit pv voltage Kya hain

    • @Hafizamanshahzad
      @Hafizamanshahzad 3 месяца назад

      @@ElectricOnline Bhai faisal ka hai mppt charge controller 65 amp ka hai

    • @Hafizamanshahzad
      @Hafizamanshahzad 3 месяца назад

      15 sy 85 Likha howa hai 12 volt par

    • @Hafizamanshahzad
      @Hafizamanshahzad 3 месяца назад

      Jaldi bataen bhai

    • @ElectricOnline
      @ElectricOnline  3 месяца назад

      3/3 ki serias bana kr Laga Lain

  • @muhammadmujahid417
    @muhammadmujahid417 2 месяца назад

    سر میرے پاس 3 پینل150 کبےاورایک پینل 300 واٹ کا ھے اور 60 ایمپر کا سادہ کنٹرولر ھے اس کا کیا کریں

    • @ElectricOnline
      @ElectricOnline  2 месяца назад

      Controller ke pv open circuit voltage range Kya hai?????

  • @SohailAnjum-uo6cx
    @SohailAnjum-uo6cx 3 месяца назад

    SIMTEK 70 amp wala mppt controller ko 585 watt canadien solar 2 plates series or parallel single battery 180 wali

    • @ElectricOnline
      @ElectricOnline  3 месяца назад

      Parallel kr lain to behtr hai kiun ke is ke max voltage range 100v hain

  • @ranagoldking.
    @ranagoldking. 5 месяцев назад

    Ser 4 plet hy 180 v ki ham 550 v ki sat lgasakty hy

    • @ElectricOnline
      @ElectricOnline  5 месяцев назад

      G Laga saktay hain

    • @ElectricOnline
      @ElectricOnline  5 месяцев назад

      2/2 ki series bana kr phir parallel kr ke Laga lain

    • @ranagoldking.
      @ranagoldking. 5 месяцев назад

      @@ElectricOnline ser 180 v ki 4 hy to 580 v ki plet keys lgy gi 4wo lagiwi hy

    • @ranagoldking.
      @ranagoldking. 5 месяцев назад

      @@ElectricOnline 4 choty hy 180 w 1 hy 550 v wo 1 sat kesy lgay gi

    • @bestvideo-mf2ij
      @bestvideo-mf2ij 5 месяцев назад

      4 plates hy 150wali to mpptv k 7 kon sa connection kreay

  • @bestvideo8508
    @bestvideo8508 3 месяца назад

    Sir mppt sy 12 v kse lan gya

    • @ElectricOnline
      @ElectricOnline  3 месяца назад

      Jahan pr battery ki wire lagatay hain wahan se

  • @Velog.Ashfaq
    @Velog.Ashfaq Месяц назад

    Inverter ki setting bta dayn

  • @Amnas_collection
    @Amnas_collection 3 месяца назад

    Hamara 55 mpr 100 w homemade company ka hai

  • @qaritariq3065
    @qaritariq3065 2 месяца назад

    ❤❤❤

  • @asi4977
    @asi4977 6 месяцев назад

    Nice

  • @RafaqatAli-sw6zb
    @RafaqatAli-sw6zb 17 дней назад

    Hello sir

  • @Amnas_collection
    @Amnas_collection 3 месяца назад

    Kis Tarah connection Karen guide mein 0314

  • @AneesAli-g6b
    @AneesAli-g6b 3 месяца назад

    Hello

  • @abidrehman7763
    @abidrehman7763 6 месяцев назад

    السلام علیکم سر میرے پاس لانجی کے تین پینل 545 واٹ کے اور تین پینل کینیڈین سولر کے 365واٹ کے ہیں اگر میں ان کو سیریز میں لگاؤں گا تو ایمپئیر پورے ائیں گے ؟۔

    • @ElectricOnline
      @ElectricOnline  6 месяцев назад

      G ampair puray ay gay but lagany se pehle charge controller ya inverter ki pv range dekh kr lagana

    • @abidrehman7763
      @abidrehman7763 5 месяцев назад

      @@ElectricOnline 4KW ka Omega ka inverter hay .Rated power 5000W

    • @ElectricOnline
      @ElectricOnline  5 месяцев назад

      G ok hai lag jay ga

    • @abidrehman7763
      @abidrehman7763 5 месяцев назад

      @@ElectricOnline جزاک اللہ خیر

    • @am_armani
      @am_armani 4 месяца назад

      ​@@ElectricOnlineIf mixed wattage solar panels are connected in series, the total voltages are added. But the amps are reduced to the current of the lowest panel.

  • @princessjia240
    @princessjia240 6 месяцев назад

    ❤good vedio

  • @tanveertariq1
    @tanveertariq1 3 месяца назад

    Sir , total 12 penals 580 watt bificial hain.. 6 uper mamti pr jin pr shadi nai ata.6 neechy chat pr jin pr subah 6 bjy se 9 bjy tk shada rehta hai or kam hota jata hai. Filhal 12 penals hi aik string series main haim. Inverter 1000 volt supported hai 32 A. Aap kia mshwra dain gy. Series main lgi rahain ya better performance k liye kuch change krna chahaiye?inveter ki starting voltage 190v hai.

    • @ElectricOnline
      @ElectricOnline  3 месяца назад +1

      Abhi ap ne sub serias main kiye hoy hain wasay abhi bhi thek hai han ap 6/6 ki serias bhi bana kr Laga saktay hain wo bhi thek rahay ga kiun ke 6/6 ki bhi banao to 330v bantay hain ek staing ke or starting 190 hai to wo bhi thek hai

    • @tanveertariq1
      @tanveertariq1 3 месяца назад

      @@ElectricOnline to sir ab setting change krni chahiye or kia us se kli benefit ho ga?

    • @ElectricOnline
      @ElectricOnline  3 месяца назад

      G kr ke chek kr lain ek Baar
      Os se ye faida ho ga Jin solar pa pr shade arha hai wo os se alag no jay gay

    • @tanveertariq1
      @tanveertariq1 3 месяца назад

      @@ElectricOnline shukriya bhai