Sir secondary to secondary core mein megger Kitna rakhna hai matlab agar 1S1 TO 2S1 ka megger karna ho toh. Aur sir aapne starting mein kya voltage apply kari thi p1 to p2 and 1s1-1s2, 2s1-2s2 ko check karne ke liye
@@BOLBULBULIndustrialElectrical thank u sir..wishing you good healty and appriciated....even im not fully understand ur language but im trying to improvement Base on your video ...thanks again sir
Sir primary to secondary mein megger 1000v par karna hai. Kya megger ki ek lead ko hum p1 yaan p2 kisi par bhi connect kar sakte hain yaan sirf P2 par connect karni hai..
Sir CT me 3 windings hota hai P, S1,S2 Damage CT me P and S1 short hai P and S2 short hai To S1 and S2 short hona chahiyye Yah short nahi dikha raha Confused Sir Please
🌹ct testing ka badhiya information 🙏
Thank you
Bhai bahut badhia bujhauchnti
ଧନ୍ୟବାଦ ଭାଇ
Very Useful Video
Yes
Bahut assa guru ji 🙏🙏
Thank you very much
जय हो
Jay hind
@@BOLBULBULIndustrialElectrical😮😢rsr😢
Thank you sir
Thanks bhai.ht ki cable fault ki earth dedactor mtr se vidio dekhaen plz
Playlist check kare. Cable section me video mil jayega.
Sir secondary to secondary core mein megger Kitna rakhna hai matlab agar 1S1 TO 2S1 ka megger karna ho toh. Aur sir aapne starting mein kya voltage apply kari thi p1 to p2 and 1s1-1s2, 2s1-2s2 ko check karne ke liye
Sir protection keliye kon sa core use karenge 30/1 ya 30/5
30/5
Nice video Odisha ra kouthu sir apana
Angul
Mu Chandikhol Ru Abe Dubai Re Job Karuchi
Great.
Sir kese pata kare ga ki
33kv Ara hai ki nehi
kya deke
Hallo sir..May i Know...what the maximum range ir test of ct?did u select 1kv or 5kv?
6.6 kv CT ke lie 5kv megger use kare.
@@BOLBULBULIndustrialElectrical thank u sir..wishing you good healty and appriciated....even im not fully understand ur language but im trying to improvement Base on your video ...thanks again sir
Hindi.An Indian language. Spoken & understood by 150 crore South Asian people. May I know Your language & country plz.
P1and p2 agar name plate nahi hai to p1andp2 ka direction kese pata kare.
Sir 11kv ki ct ke liye megger test range kya rakhni hogi primary to secondary?
5 KV
@@BOLBULBULIndustrialElectrical ok
Sir primary to secondary mein megger 1000v par karna hai. Kya megger ki ek lead ko hum p1 yaan p2 kisi par bhi connect kar sakte hain yaan sirf P2 par connect karni hai..
If you are meggering a 6.6 KV CT ,you have to use 5 KV .
For below 1 KV CT apply 1 KV megger .
Aap P1 ya P2 kisi par bhi connect kar sakte hain.
@@BOLBULBULIndustrialElectrical ok
Sir आप वीडियो में बता रहे है 6.6 kv के लिए vol 1000v select karen
11 kv के लिए कितना select करें
Sir mujhe aapse baat karna hai ...kuch questions puchana hai
Wtsp no dijiye plz
8249341942
Sir
CT me 3 windings hota hai P, S1,S2
Damage CT me
P and S1 short hai
P and S2 short hai
To
S1 and S2 short hona chahiyye
Yah short nahi dikha raha
Confused
Sir Please
Meggering karke dekhe.
@@BOLBULBULIndustrialElectrical
Thanks
sir Mai video ki bat Kar raha hu
1000V?
Kuchu malumu he ki nehni app ko a koi bata he ji bacha Bali bata hogaya
Watch other videos related to CT.