Setting Up A Subpanel For An Outdoor Barrel Sauna

Поделиться
HTML-код
  • Опубликовано: 21 дек 2023
  • We share some great advise and show you how we would do electrical work for a Barrel Sauna.
    petersonelectricllc.com/
  • ХоббиХобби

Комментарии • 8

  • @vince6829
    @vince6829 17 дней назад

    Thanks for sharing.

  • @mike3133f
    @mike3133f 6 месяцев назад

    Did they have to anchor that to the patio? Boulder wanted drawings showing it could withstand 100mph winds so I just went with a modular inside sauna. Its in my storage unit now, long since moved.

  • @safetythirdified
    @safetythirdified 7 месяцев назад

    Hey brother, knowing that you need to do a load calc to figure out the minimum requirements for the size of a sub panel, what is the maximum size you can put? Any code or rule of thumb on how large the ampacity of a sub panel can be?

  • @Shadi2
    @Shadi2 7 месяцев назад

    Any risk of the flex being a trip hazard?

  • @gooneybird808
    @gooneybird808 5 месяцев назад

    that sting

  • @kobi1606
    @kobi1606 7 месяцев назад

    300.9 Raceways in wet location above grade, the interior of the raceway shall be considered to be a wet location. 334.12 (B) NM shall not be used in damp or wet locations. 7500 watts / 240 V = 31.25 Amps, your disconnect and fuses are too small.

  • @Firehawk841
    @Firehawk841 3 месяца назад

    That LFMC is not rated for damage. you cant run it flat on the concrete like that.

  • @WardCo
    @WardCo 7 месяцев назад

    *advice (not advise)