Japanese Gas Fan heater error code 11 , 12 or 14 Fix

Поделиться
HTML-код
  • Опубликовано: 12 дек 2022
  • Welcome To Jamber Thinks
    -
    Visit or Subscribe My 2nd Channel On RUclips for Hand Working Home Appliances: / @jamberthinks
    Like Me on Facebook: / rehan18110
    Visit My Blogs: rehanjamber.blogspot.com/
    -
    #japaneseheater
    #jamberthinks
    #errorCode11Fix
    AH Refrigeration Islamabad
    What is error 62 on Japanese gas heater?
    What is code 62 on a Rinnai heater?
    What is error 12 on Japanese heater?
    What is error 12 on gas heater?
    What is error 12 on Japanese heater?
    What is error code 11 on gas heater?
    What is error code 14 on a heater?
    What is error 12 on gas heater?

Комментарии • 75

  • @user-hb5sz5xv5n
    @user-hb5sz5xv5n 4 месяца назад +1

    Thank u aj mai nai khud heater theek kiya ap ki video daik kr thank u ❤

    • @JamberThinks
      @JamberThinks  4 месяца назад

      Thanks for sharing your information....
      Me air achi videos bnany ki try Karon ga

  • @peterm.9672
    @peterm.9672 Год назад +1

    Thank you, sahebji. I have seen your other videos. This one is exceptional.

    • @JamberThinks
      @JamberThinks  Год назад

      Thanks for your opinion on my work...
      Please subscribe for more help

  • @azhariqbal1390
    @azhariqbal1390 Год назад +1

    بہت اچھی اور معلوماتی وڈیو ہے۔ زبردست

  • @peterm.9672
    @peterm.9672 Год назад

    Asalamalaikum. Please advise... I want to install the 220-110 converter inside the heater. What is the lowest wattage that these heaters will work?

    • @JamberThinks
      @JamberThinks  Год назад

      80 to 120 volt AC operational for Japanese heater.
      If you have 220 volt so you can use converter or step down supply to operate..

  • @ejazrana7281
    @ejazrana7281 6 месяцев назад

    good job

  • @mubasherusman3943
    @mubasherusman3943 Год назад

    subscribed. MashaALLAH app kis jagha say ho

    • @JamberThinks
      @JamberThinks  Год назад

      Thanks for subscription.
      I am from Islamabad...

    • @mmu200
      @mmu200 Год назад

      @@JamberThinks mujhy same error aa raha . Main faisalabad say hoon. Mery pass tool nahi hain. Yahan kisi bandy ka pata bhi nahi jo is ko hal kerta ho

    • @JamberThinks
      @JamberThinks  Год назад

      @@mmu200 do a full service.
      As same as my video...

  • @hafeezullah1543
    @hafeezullah1543 5 месяцев назад

    Assalam o alaikum. Bhayi blower bht ziada noise kr rha ho to iski kia reason hoti ha

    • @JamberThinks
      @JamberThinks  4 месяца назад

      Us k barrings replacement ki zrorat ha

  • @pairmohamad3817
    @pairmohamad3817 Год назад

    Sir g ignshen koil mosalal on rahta ha

    • @JamberThinks
      @JamberThinks  Год назад

      Us ka thermocouple sensor check karen....
      Aur agar samj na aay to hm su WhatsApp py rabta kren
      03034717372

  • @03455631164
    @03455631164 Год назад

    Allah bless you long time. Shabash

    • @JamberThinks
      @JamberThinks  Год назад

      Thank you so much....
      Please subscribe for more update....

  • @user-rk9pz3co8d
    @user-rk9pz3co8d 4 месяца назад

    Asslam o alaikum, brother error 11 arha hy. Thora chlta hy heater gas py sath hi error 11 ajata hy.

    • @JamberThinks
      @JamberThinks  4 месяца назад

      Gas nhi aa rhi ya gas solenoid walve khrab ho gia ha solenoid check Karen

  • @atif.m9065
    @atif.m9065 4 месяца назад

    Bro error 14 ka kia solution hai?? 5 mint chalta ha phir error 14 aa jata ha,, kindly ap apni shop ka address de dain.

    • @JamberThinks
      @JamberThinks  4 месяца назад

      us me service ka issues ha service Karen to theek ho jay ga

  • @brotherselectricstore5122
    @brotherselectricstore5122 5 месяцев назад

    osaka gas 140-9012 error 70

    • @JamberThinks
      @JamberThinks  5 месяцев назад

      Fault Code 70: Faulty ON / OFF Switch

  • @asadsatti2159
    @asadsatti2159 4 месяца назад

    Mara hetar 2 mint chal k phr bnd ho jata ha matlb garm howa ni dat bep k bad bnd ho jata ha

    • @JamberThinks
      @JamberThinks  4 месяца назад

      Koi error flash hota ha display screen men

    • @asadsatti2159
      @asadsatti2159 4 месяца назад

      Ma check kr k bata hn bro

    • @asadsatti2159
      @asadsatti2159 4 месяца назад

      Aoa bai es 12 likha ahta ha

    • @asadsatti2159
      @asadsatti2159 4 месяца назад

      Lpg pa chala raha hn es ko 1 2 mint chlta ha phr erro 12 likha ahta ha or bnd ho jata ha kindly bata dan masla kaya ha ma na wal b lagya howa ha pipe k sath ta k gas ko control kiya ja saky

  • @Punkgaming329
    @Punkgaming329 4 месяца назад

    Salaam sir mere paas bhi hybrid heater h 5 mint chalta h phir blower slow ho jaata h aur screen pe 1 H aur LL ka error aanay lag jaata h uss ki thori der baad 70 fault aa k heater bnd ho jaata h any solution ???

    • @JamberThinks
      @JamberThinks  4 месяца назад

      Air flow blockage

    • @asadsatti2159
      @asadsatti2159 4 месяца назад

      Ya kasy thek ho ga bro

    • @JamberThinks
      @JamberThinks  4 месяца назад

      @@asadsatti2159 maybe your heater dip switches faulty

    • @JamberThinks
      @JamberThinks  4 месяца назад

      Check dip switches in ECU board

  • @abidsikandar1342
    @abidsikandar1342 Год назад

    Plz give me ur contact no..I have the same blower but out of order...u want to fix it...

  • @mixstuffdiy7784
    @mixstuffdiy7784 Год назад

    Bhai 5-10 min chalny k baad error 12 ajata ha .waja kia hogi

    • @JamberThinks
      @JamberThinks  Год назад

      Gas ka issues ha gesar ky wal ki clean up karen aur us ka thermocouple sensor check karen

    • @mixstuffdiy7784
      @mixstuffdiy7784 Год назад

      @@JamberThinks pic dikha dain dono ki

    • @mixstuffdiy7784
      @mixstuffdiy7784 Год назад

      @@JamberThinks gas pressure full ha humary area ma

    • @JamberThinks
      @JamberThinks  Год назад

      @@mixstuffdiy7784 thermocouple check karen apny heater ka

    • @jazbapk5282
      @jazbapk5282 Год назад

      Same happening with me, gas pressure taiz ho tu 12 ata ha. Ap valve thora opn kro phir nai ana error . Waisa mein shop la la k b jaon ga wo keh rha tha andr sa thora pressure kum kr don ga bar bar valve nai cherna pra ga. Kisi time taiz hoti kisi time low. Agr low ho bauth tu error 11 ata. Thanks

  • @wouldfunny
    @wouldfunny Год назад

    00 error kasy theek ho ga

    • @JamberThinks
      @JamberThinks  Год назад

      00 ka error code electricity failure se aata hai heater ko restart karen to theek ho jay ga

  • @muhammadhamid2933
    @muhammadhamid2933 5 месяцев назад

    Error 12 Q ata hain

  • @alimohsin2359
    @alimohsin2359 3 месяца назад

    Bhai error code 05 kis cheez ka he?

    • @JamberThinks
      @JamberThinks  3 месяца назад

      Air filter maybe missing or not installed correctly...

    • @alimohsin2359
      @alimohsin2359 3 месяца назад

      Ye kahan hota he front ya back pay

    • @alimohsin2359
      @alimohsin2359 3 месяца назад

      Osaka Gas GFH-930DE model he

    • @JamberThinks
      @JamberThinks  3 месяца назад

      Back py ik bari si jaali lagi hoti ha

  • @dildartechnician3420
    @dildartechnician3420 6 месяцев назад

    Fault nahi batya

    • @JamberThinks
      @JamberThinks  6 месяцев назад

      Gas walve k andar problem thi jis se gass nhi aa rhi thi sfaai karny sy hal ho gai

  • @user-rk9pz3co8d
    @user-rk9pz3co8d 4 месяца назад

    Runny almost 30 secont then error 11

  • @thesmartfencier7650
    @thesmartfencier7650 Год назад

    app ka number

  • @peterm.9672
    @peterm.9672 Год назад

    Asalamalaikum. Please advise... I want to install the 220-110 converter inside the heater. What is the lowest wattage that these heaters will work?

    • @JamberThinks
      @JamberThinks  Год назад

      80 to 120 voltage AC

    • @peterm.9672
      @peterm.9672 Год назад

      Sorry for the double post. My meaning is the watt

    • @peterm.9672
      @peterm.9672 Год назад

      @@JamberThinks You mean 80 to 120 watt, yes?

    • @JamberThinks
      @JamberThinks  Год назад

      No brother japanese Gas heater uses 3 to 45 watts at 120 voltage...

    • @peterm.9672
      @peterm.9672 Год назад

      @@JamberThinks So, for example, if I get a 220 to 110v converter, with capacity of 40watts, it will work, correct?