HOW TO SOLVE AC GAS LEAKAGE IN TAMIL | ஏசி காஸ் கசிவை எவ்வாறு தீர்ப்பது | ECDIAL | AC SERVICE
HTML-код
- Опубликовано: 7 сен 2024
- #ECDIAL
#AC_SERVICE
#AC_CLEANING
#AIR-CONDITIONER_SERVICE_IN_TAMIL
#ECDIAL_YOU_TUBE_CHANNEL
#AC_INSTALLATION
#AC_GAS_LEAK
WHY HAPPEN?
The most common cause of AC freon leaks is likely erosion of the metal over time due to formic acid or formaldehyde corrosion. Small holes are formed when the acid eats away at the metal and the unit eventually releases freon.
COIL LEAK:
When a coil leak happens that usually means your Freon is low. When this happens, your AC cannot pull the heat and humidity from inside your home to cool it properly. The bad thing is that this is not the only thing that can happen, your AC unit can actually start freezing up which can cause more damage to your unit.
AC SERVICE:
An air conditioner, just like a car, needs regular maintenance and service to run efficiently. I recommend getting your AC unit serviced and cleaned once a year. You should do this in the Spring to ensure that your unit will run with the most efficiency during the hottest Summer months.
AIRCONDITIONER ECO KLEEN SERVICE IN TAMIL | ECDIAL
• AIRCONDITIONER ECO KLE...
GAS LEAK IN TAMIL 2020
• GAS LEAK IN TAMIL 2020...
RESTORATION OLD RUSTY AIR CONDITIONER IN TAMIL | ECDIAL
• RESTORATION OLD RUSTY ...
HOW TO INSTALL SPLIT AIR CONDITIONER
• 2020 TOP 5 BEST AIR CO...
AIR CONDITIONER NORMAL SERVICE IN TAMIL 2020
/ mqdtnrh6z
AIRCONDITIONER INSTALLATION 2020
• AIRCONDITIONER INSTALL...
AC GAS LEAKS:
• AIR CONDITIONER GAS LE...
Do Like and share it as much as you can in all your Facebook and WhatsApp groups for other people's help too.
Facebook: / ecdial
Instagram: / ecdial
E-mail: edecdial@gmail.com
WhatsApp only: 8428118111 (10AM-5PM)
Whatsapp Group Link: chat.whatsapp....
Website: www.ecdial.in
CAST: A.C. Nandha Kumar
SCRIPT & DIRECTION - A.C.Nandha Kumar
ASST.DIRECTOR & CAMERA - J.Ruban Kumar
EDITOR -V.Kiruthika
POSTERS - N.Poongodi
DISCLAIMER
Responsibility Disposal
This video including examples, images, and references are provided for informational and educational purposes only. The names of actual companies and product mentions herein may be the trademarks of their respective owners. Credits shall be given to the images taken from the open source.
Advice, graphics, images and information contained in this channel is presented for general information and to increase overall safety awareness.
The above scenarios and illustrations are done by a good handful of technicians People need to do good training and consult a technician before doing this, otherwise they should not do such work.
Note:
The power supply must be turned off before all such technical work can begin.
Brand?
Samsung
Samsung worst company 😀
Godrej
Like g
@@sheikbaseer5681 voltas also same problem only
Super bro warranty claim
Pannama ungala kooptu panirukaangana ungala mela evlo nambika irukum really hatsoff to your customer services of genuinism and prevention from future problem..Your the best bro All the best in few years you'll be all over tamil nadu top place for ac servicing and dealing congratulations 💐💐💐
என்னுடைய voltac ஏசி 1.5 டன் .... Gas leakage உள்ளது. சரி செய்வதற்கு எவ்வளவு செலவாகும்?
sir, I am facing gas leak problem regularly... At present i spent more money than the actual cost of the AC... Everytime service person take 3000 Rs saying gas leak... This time with 3 days gas is out... no cooling
Coil leakage Eppidi identify pannurathu bro, athuku oru video poduga bro
Super Bro' nalla theliva solringa, thozhilum suthama irrukku. Keep itup. Naan Perambur la irrukken. Service/ complaint attend pannuveengala. Ennudaya AC Onida 1.5 ton.
Excellent bro 👌👏👏👏 Bro Samsung AC protect vantha nalamiya bro 😅🙏
ஏசி கம்ப்ரஸர் ல ALLEN key setting பற்றி வீடியோ போடவும், பயனுள்ளதாக இருக்கும் எங்களுக்கு
Bro Really super genuine work 👌
Not only Samsung , I rectified the coil leakage in Daikin unit which is 9 months old
Sir, nitrogen pressure how much in indoor and outdoor for leak test in safety.
You Legend bro
Some kind of smell is coming from my New(5 days old) Blue Star Non- inverter AC while running and also some sound(Could be due to condensate water but I am not sure) is coming from indoor unit when the compressor starts. But No issues with Cooling. Is that Normal? Or should I call the AC technician?
Entha ooru Bro. Madurai'la Service Panuvengala
Very useful..
please use pressure regulator in cylinder
If we use regulator we can't get 300psi and 500psi pressure bro.
Thank you bro
How to identify gas leak in indoor unit
How often we need to do e clean service? Is it different from normal service? Is it covered under free service? Pls explain bro
Bhai kya hame Pas nitogan aveleble nahihe tho kya ham likej chek karneke liye dusre fridge ke compressor se pressure testing karskte he kya kas kar r32 vale sistem me please help me
very nice bro sema
Semma video nga
Bro i m continue seeing your videos..... And after seeing your carrier 1.5 durafresh Nx model i will buy that Ac sooo your every points very useful and valuable thing with me...... And important thing is i have old Ac on samsung split Ac 1.5 ton that's also same prob leakage sooo if u service that Ac???? Pls reply me
Which area bro
Adyar bro... near ramanujam it park
Super bro.
Nice work
அண்ணா வணக்கம் பிறிச்சில் 134a gas ஏற்றும்போது கம்பிறசரில் உள்ள வால்வு ஏன் மூடுகிறது முழுமையன கூளிங் கிடைக்க முன்பு
Same yenakum ithe problem new ac la 3 times maathuna piragu tha crt ah iruku...haier service is worst...
Do you conduct any pratical traning in Bangalore if yes please let me know
Good.
Thanks sir
🙏
Had 10+ Yrs of LG 1.5 split ac normal old model non-invertor...refilled R22 -Gas..but again after 2 days no cooling, than technician said no leakage in outer unit but might be mild leakage in inner unit, he said better to change with new indoor unit only since outdoor unit is good...my question is will outdoor unit will also create problem since it is 10+ Yrs old...so should I change both indoor and outdoor as a new set itself.., can we repair multiple leakage, centre of condenser coil...???
Better to change the unit
Great bro
Voltas 1.5 டன்.. Gas leakage சரி செய்ய எவ்வளவு செலவாகும்..
Bro Lg inventer ac ku ethana core wire வரும்?
Bro gas leakage weld and gas refill cost Average aa enna aagum??
Samsung have many prombles
nitrajan patil r 22 gas godugalama
Hello sir, dc curret 12v/24v running ac iruka? Or ac running in solar?
Bro n2 pressor ahh inga karaikudi la compressor vachu leak pakuram
Bro nitrogen illama air pressure kuduthu leak cheak panalama
Bro ivlov charge Panuvinga indha service iku?
Where u will do leak check at coustomer location or at service centre ....
Service centre
Thangs sir
Haier ac bro vangi 2yrs aagudhu ana vacum iruka nu theriyala ....athunala problem varuma bro
For more information follow us on,
Instagram Link: instagram.com/ecdial/
Facebook Link: facebook.com/ecdial
sir, please reply panna...AC vangi 4years aguthu gas leak aguthu.. indoor and outdoor unit check pannitanga.. no leakage sollittanga... 2monthla 3times gas fill panittanga... AC mechanic yenna problem nu thiriyalla... Solution sollunga
Pls call 8428118111(10am to 5pm)
Bro R32 gas pressure tell me
R32 ac gas pump down panalama
நைட்ரஜன் இல்லாம ஏர்ல கேஸ் லீக்கேஜ் பார்க்க முடியுமா
New AC vangi 1 week achu samaya bad smell varthu, ithuku gas leakage problema ji?
What was the cause of smell? Did you find out? Some kind of smell is coming from my New(5 days old) Blue Star Non- inverter AC while running and also some sound(Could be due to condensate water but I am not sure) is coming from the indoor unit when the compressor starts. But No issues with Cooling. Is that Normal? Or should I call the AC technician?
Bro water test pannalama
Brazing panitu odaney water aaple pana kudathu
Your service available for Coimbatore
Available bro
Sir, share your mobile number
சார் எங்க ஏசி. வோல்டாஸ்.வாங்கி ஆறு வருடமாய் நன்றாக ஓடியது.வீடு மாற்றினோம். பிறகு இரண்டு முறை கேஸ் லீக் ஆனது.காரணம் அலுமினியம் காயில் வீணாகிவிட்டது.காப்பர் காயில் மாற்றினார்கள். மீண்டும் 20 நாளில் கேஸ் லீக் ஆகிவிட்டது.காரணம் கேட்டால் வீடு பெயிண்ட் அடிக்கும்போது அவுட்லெட் ஒயரிங் ஆட்டிவிட்டார்கள் அதனால் கேஸ் லீக் ஆகிவிட்டது.. மீண்டும் கேஸ் பிடித்தோம்.11 ஆயிரம் மேல் செலவு செய்து விட்டோம்.எதனால் சார். மீண்டும் செலவு வைக்குமா. எப்படி பராமரிக்வேண்டும்.
frst oru nalla technician vechu check panunga bro..leak aah kandu pidichi arrest pana solunga... apdi panitinga athoda prblm varathu
@@coolingsystem9402 selavu seiyathinga waste . Pudhusu vaangidunga.
@@AntonyBA-io7kz technician poruthu iruku bro
Ithe Problem En AC'kum Vandhuchu Bro... Sari Panla Aana 4000 Vangitu Poitan.
Bro call him for solve the problem
@@Ecdial Epayo Nadandhadhu Bro. Ipo Na AC change Paniten
@@vishnukumar-sv9cv again leak agi irukum bro
@@coolingsystem9402 Ama Bro.. Sariya Service Pana Again Leak Aachu.
Panasonic Inverter A/C review bro
Ok bro
Starting 3-4 min small pipe la ice katuthu, athuku apram droplets of water Enna reason normal ah edhu carrier AC
Ice pidichale gas ilanu artham g
Chennai la unga service eruka bro mobile number pls
Andavne nee engappa irukkey?
Are you having service center in Chennai give me number
இப்பதான் ஏசி வாங்கினேன். வாங்கி 15 நாட்களுக்குள் மூன்று முறை வந்து மாற்றி சென்று விட்டாா்கள்.
What problem bro
@@Ecdial first day installation indoor swing and display problem. Next week change indoor. After few days outdoor gas problem. Totally change now.
Which brand bro
என்னுடய ஓனிடா 1 டன் ஸ்பிரிட் ஏசியில் லக்கேஜ் உள்ளது உங்களால் சரி செய்து கெடுக்கமுடியுமா.
பிரபாகரன் வேளச்சேரி 8667460037
தயவுசெய்து தெடர்பு கெள்ளவும.
நன்றி
@@Ecdial g என்றால் புாியும் என நினைக்கிறேன்.
What is the charge u collect?? Is 3600 fair ?
Bro unga services center enga irruku bro pls share your contact number
Super bro
Thanks anna
Super bro