Pressure, Intensity and the Decibel (dB) Scale | Ultrasound Physics | Radiology Physics Course #3

Поделиться
HTML-код
  • Опубликовано: 22 янв 2025

Комментарии • 39

  • @Objectra
    @Objectra Год назад +10

    Came across the US probes explanation and also decided to watch the whole playlist. While im familiar with most of this information (i build medical ultrasound probes as part of my job), it was great to defragment my knowledge and put it in order based on your videos. A refresher is also a huge plus. Thank you so much for making it so easy to understand and follow.

    • @radiologytutorials
      @radiologytutorials  Год назад

      Cheers. I'm glad they were still helpful! Still have a lot to learn myself!

  • @brandideruiter6067
    @brandideruiter6067 11 месяцев назад +1

    Im studying for me spi after years of being out of my field of cardiovascular ultrasound tech. These videos are helping a lot.

  • @Roomso1
    @Roomso1 Год назад +2

    Stumbled across your video of time gain compensation, and it was so good that I decided to watch through this entire series. These four videos that i’ve now watched have all been great! Thanks for making these ❤

  • @DrThalesAlexandre
    @DrThalesAlexandre Месяц назад +1

    Amazing lectures, sir!

  • @hartisify
    @hartisify Год назад +3

    Great explanation and you have a fantastic voice.

  • @ehsanhosseini5636
    @ehsanhosseini5636 13 дней назад +1

    Thank you so much

  • @fabrizziogaliano515
    @fabrizziogaliano515 Год назад

    Finally I know what is the db bottom for... thank you very much...

  • @prathamgupta3117
    @prathamgupta3117 11 месяцев назад

    Honestly these videos are helping me alot for my exams

  • @RosemaryWairanya
    @RosemaryWairanya 7 месяцев назад +1

    You are helping me much 🙏

  • @masoodandalib8676
    @masoodandalib8676 9 месяцев назад

    you are so great and a unique teacher.

  • @georgesdibeh7826
    @georgesdibeh7826 3 месяца назад

    Hello sir
    How about ultrasound on compressed gas
    Like nitrogen at 14 bar in an extinguisher
    Can it detect it

  • @rukhsanaarshad1465
    @rukhsanaarshad1465 6 месяцев назад

    Thank you very much sir

  • @jax_your_girl_1203
    @jax_your_girl_1203 Год назад +1

    Hey, I love your videos ! :) I have one question. In video 4 (Pulse Echo Ultrasound Parameters) you say the PRF can vary depending on the depth of tissue you want to measure. If I understood correctly that means by determining the depth of tissue the PRF is automatically (?) adjusted. Here in this video you say that the frequency of the transducer determines the depth of tissue that the ultrasound can reach. So how does that work together when there is the frequency of the pulses and the frequency in which the pulses are sent that influence the measuring depth? Like what if my choice of transducer and frequency of the ultrasound waves is inconsistent with my choice of measuring depth which only has an influence on the receiving time and PRF and not on the pulse itself ?
    I hope you understood my question, I am from Germany 😂😂

    • @radiologytutorials
      @radiologytutorials  Год назад +2

      Hi Jaqueline. Sorry for the delay. I’ve been on holiday. Great question. So attenuation is in part determined by frequency - high frequency waves get attenuated quicker over a shorter distance than low frequency waves. However, we do not use frequency to determine the depth shown on the ultrasound display. PRF (ie the number of pulses we send into tissue per second) determines the depth displayed - as you’ve correctly said. If we set a low PRF it means in theory we can display ultrasound information to a greater depth. This is because the pulse repetition period will be longer - allowing enough time for waves to travel deeper and return to the transducer before the next pulse is sent out. However, the actual ability for that wave to travel to that depth is determined by the frequency of the wave. If we use a frequency that is too high there will be no returning echoes from deeper tissue because the wave is attenuated too soon. This will look black in the ultrasound screen if we set the depth too deep using the PRF.
      So the PRF is automatically adjusted as we select a certain depth but whether we’ll get any information from that depth depend on the transducer frequency (that’s why we use high frequency probes for superficial structures and lower frequency probes for deeper ones) I hope that makes some sense 😅

    • @jax_your_girl_1203
      @jax_your_girl_1203 Год назад

      @@radiologytutorials Ah okay I see, thank you ! But is it possible to use a higher transducer frequency for better resolution and still gain depth information with the help of TGC? Or will I get false data ?

  • @sohamrasal7054
    @sohamrasal7054 Год назад

    Thank you so much for making these videos sir❤
    I have one query
    Why we put decibel in the area section? If it is change in intensity then it should go along with it right?

    • @radiologytutorials
      @radiologytutorials  Год назад

      Good question. Mainly due to space. Strictly speaking it should be in neither the time or distance domains (it is a relative measure containing no time or distance units). But mainly because there was no space on the slide 😊

  • @nickogalo2892
    @nickogalo2892 Год назад

    Great job

  • @TriPham-j3b
    @TriPham-j3b 2 месяца назад

    Architectural design of mind

  • @annabee1734
    @annabee1734 Год назад

    Great work

  • @nyssaangelipura6076
    @nyssaangelipura6076 Год назад

    Can I please ask for your book references? ❤

  • @TriPham-j3b
    @TriPham-j3b 2 месяца назад

    Can we detox all poluted toxin in body by control environment? That called rebirth frequency affect too

  • @nazaninsaleh3938
    @nazaninsaleh3938 Год назад

    well done

  • @shakhawansalih5601
    @shakhawansalih5601 Год назад +1

    little hard to understand but very very nice explanation ,needed many repeat hearing to understand it

    • @radiologytutorials
      @radiologytutorials  Год назад +1

      Thank you. Yeah, these concepts can take time to grasp. Don’t get too caught up in the details. A broad understanding is often for than enough!

    • @qura-tul-ainmuzaffar9367
      @qura-tul-ainmuzaffar9367 Год назад

      ​@@radiologytutorialsplz guide about how and what to study for FRCR 1 exam...plz

  • @dradityakumar3157
    @dradityakumar3157 Год назад

    Please add MRI physics videos or take MRI physics classes also…

  • @tcc9826
    @tcc9826 6 месяцев назад

    This chapter is too complicated. I suggest splitting it into two.

  • @dalalyousef6513
    @dalalyousef6513 Год назад

    you're the only person who helped me get through ultrasound and MRI physics thank youu🤍