Earth Work Measurement for Billing
HTML-код
- Опубликовано: 8 сен 2024
- Earthwork Calculation / Excavation Work Calculation - In this video i have discussed about earth work items as Excavation, Back filling of Soil, and disposal of surplus earth, In this video you get what is the connection in three items and how to cross check your billing measurements. BILLING ENGINEERS MUST WATCH THIS VIDEO FOR BASIC CONCEPTS FOR EARTH WORK ITEMS BILLING.
Also Please request Kindly watch below Link of IS 1200 Part 1 for Complete Mode of Measurement of Earth Works As Per CPWD / IS 1200 - • IS 1200 Part 1 - Mode ...
This video only purpose for cross check to your measurements by Quantum of excavation claim in bill as per Back filling Qty + Disposal = Excavated Quantity
#FactualCivilEngineering
#EarthworkBilling
#Excavation
#Backfilling
If you have any for this important topic please comment.
How u have taken offset for PCC 150
Rcc work Mai labour aur machine name kya kya lagenge
Your quantity rate analysis video is so good I see your video I'm prepare excel sheet
It's very important video . Keep making such a video.
It's a very deep point, thanks for video, it seems you have profound knowledge in practiclly site functions, keep sharing such kind of information.
Logically point, good explanation with basic detail. Thanks for information
I really wish if you could give classes on quantity surveying. Much needed
Kamal ki explanation kii ha aap ny sir love from 🇵🇰
Narayan Bless 🙏 You
very nicely explained Amit bhai. god bless u
Nice point and good explanation
👌
Sir aap super se v upar ho
Explain earth work excavation calculation with slope 45degree
Very nice sir
If we say to interviewer that working space is 0.500 m (as you said), interviewer will say us wrong because as per cpwd specifications (2.11), or IS1200:1, working space is 0.300 m for up to depth 1.5 m, and working space shall be considered 0.750 m if depth of excavation increase from 1.5 m.. So kindly explain right method.
ruclips.net/video/DPLRuZZE3zU/видео.html
I am searching this , is any have right answer given here...good one brother...
Sir as per previous video, offset was 450 mm on both sides if depth is more than 1.5 metre, but we are taking 500mm in this video?
Thanks sir
Good explanation sir!!
Thank you bhaiya.....
PCC ka offset as per is code h ya apni marji se
working space is taken 300 from footing or pcc?
IS 1200 part 1 1992 revision 4th no mention working space 500mm carrying out
Beam and column jountion ki shuttering & rcc ko kese lete h high-rise building me & low hight building in billing
Trapezoidal excavation ka billing kaise karte hi sir
Billing video banao rcc road ke baare Mai
load bearing k earthwork and measurement prr video banaiye.. please
Please tell about Backfilling quantity?!
Sir please send all video in IS 1200 CODE MODE OF MEASUREMENTS all part
Do you have any video on the Construction steps of mass diagram
नरेगा का बीडीओ bany sir
Sir ,how to calculate of slop cutting areas ,plz. Upload another video ,I will to your video ,than you so much !!!
ruclips.net/video/DPLRuZZE3zU/видео.html
sir, please upload pdf also of this video it's quite helpful for me
Sir ap billing brand channel bana do isse
Ek question bataiye sir agar excavation hui hai kisi structure ki Hamne usko excavation m paid kr diya uske bad disposal ki soil se Usne kisi area m filling kr di aur Agli item earthwork in cutting & disposal of excavated earh m Usne claim kr diya to Hame wo quantity excavation m se cut krni chahiye ya nhi.
Sir road ka earth work calculation bataiye na cutting filling
Sir, do we have any tolerance due to compaction during backfilling?
Sir estimate banana bhi batye
Working offset kaise liya?
Sir I have one query if we do 5.3 mtr deep excavation in 6 diameter in circular way then what is the proper method of billing
ruclips.net/video/DPLRuZZE3zU/видео.html
How is 3m come for height?, height is 0.5 m
Disposal of soil
Loose soil hoti hai
+ Back filling v loose hoti hai to excavated soil se kaise equal hogi brother
Disposal walai Mai voids deduct hotai hai
if excavated material concsists ordinary soil, hard rock both then how we take measurements
There is a line need to add in BOQ item i.e. "ALL KIND OF SOIL" for excavation item
It dependa on how dee u gonna excavate. If ur excvation is do deep, u need to provide strut , waller, post tensed anchors at where the soil is weak. So basically as sir said, u nees to bifercate the activty. The soft soil where soil is weak had be paid more from the client due to thw temporary structure. On the other hand as u go low, hard rock dosent need waller n struct support. So as well paid less because hard rock can also be used for backfilling purpose for other project.
Sir, Kisi item Ka agar hum excavation le liye Hain , us Ka dressing mein Measurement Le sakte i??
Agar hum Backfilling Kar rahe Hain , for uska dressing lenge ya Nahi??
Sir please tell if possible
I think not kyu dressing include hoti h backfilling k item main, BOQ item ko detail main studay karo
@@FactualCivilEngineering ok sir
Sir I have seen your all video
Please help me improve my quantity surveying knowledge......
How to contact you
Lift v milta hai sir above 1.50 meter depth Jane K bad. Or working space 500mm nahi hota h as per CPWD spec se. Working space up to 1.50m tak 350mm. Above 1.50 m 750mm hota h o v information dejeya.
Thanks Manoj for your comment, Please watch this link ruclips.net/video/eD_dKWdzdcs/видео.html, IS 1200 Part 1 wherein i have explained all information about What is the Mode of Measurement of Earth work Excavation, Clear your doubts regarding this topic, thanks for your kind support.
ruclips.net/video/DPLRuZZE3zU/видео.html
This cant be true.....because after Excavation 30% qty gets increased. Tight soil to loose soil approx 30% gets increased..pl clarify
Aap refinery me job krte ho kya??
Nahi 2012 main GAIL ka project kia tha. As a traine engineer.
Billing in earth work
ruclips.net/video/DPLRuZZE3zU/видео.html
try to speak in english
Thank you sir