L&T CX2000 VFD Wiring in Hindi| 2Wire (Selector Switch) 3 Wire (Start Stop Pushbutton) Potentiometer
HTML-код
- Опубликовано: 6 окт 2024
- L&T CX2000 VFD Wiring in Hindi | 2Wire (Selector Switch)and 3 Wire (Start Stop Pushbutton) Potentiometer
L&T CX2000 VFD Basic Parameter Setting In Hindi | L&T CX2000 VFD Programming| (Part 1)
• L&T CX2000 VFD Basic P...
L&T CX2000 AC Drive Programming and Control Terminal Wiring. L&T CX2000 VFD Wiring Diagram. L&T CX2000 VFD Parameter.
Parameter Explain
Drv : Run command
1) Start Stop Pushbutton
2) On oFF Switch or Selector switch
Frq : Frequency Command
1) Keypad Potentiometer
2) Up Down Keypad
3) External Potentiometer
L&T , CX2000, VFD, Wiring, Ac Drive
Thank you so much sir 🎉you solved my problem
sir nice vedio👌👌👌
SX2000 vfd pr vedio banaye please🙏🙏🙏
Thank u sir aapka videos dekh ke maine apne machin ka parameters chalu kr diya .. thank you so much
Good evening sir 🙏
Sir L&T sx2000 drive ke bare me bataiye, ki moter ka parameter kis group me dalte hai. Aur iske manual me kis page par Kaun sa parameter hai.
Sir ji L&T sx2000 se pic101 control pe current kase dikhaye or paramitar sae set kare
Very nice explain and Very informative videos keep it up.
Thank you
sir 2 speed perimeter & waring ke bareme next video daliye
Sir Display m RPM show krne k lye kya kare inplace of frequency
Sir power factor CT ratio pr video bnaye sir
Sir very helpful thanku.mujhe 4.to 20 mili amp dena hai drive ko our use plc se rpm control Krna hai to.konse terminal pe du.sir.our parameters kya change kr a hoga pls rpl sir
You can do it easily just Do FRQ 5
And provide miliamp reference to I and CM* check the drive is in PNP aur NPN at dip switch end
Sir Nx2000+ k liye parameters control or control wiring pr vedio bnaaye pls sir
Very very nice video
Sir. Cx2000 me. Selector switch se 3 different frequency me Chalana hoto KyA Krna rahega.
Sir plz make more video.
sir super👍💯😘😘😘😘 sir plc hmi se operate kare💯💯
Sir Fuji frenic ace drive main (Ot) foult Kya h?
End Timer (ET) specifies the waiting time from when the control object stops at E point until the inverter can receive the next positioning control signal. After completion of positioning, when this waiting time has elapsed or when 0.5 second has elapsedif ET < 0.5 second, the inverter issues the "Positioning completed" signal "PSET" or "Stop point alarm" signal "OT".
Thanku sir very good
sir hamne vfd ko apne matasys controler se control kiya magar frequensi badhane me problem aa rahi h kya kare sir please koi rasta bataye
Very nice videos sir
Nx 2000ke liye video banaye
Superb thank
Mere pass vfd SX 2000 model hai 11k ka mujhe plc se connection karna hai kaise karenge
Good teaching broo
Sir meri VFD m 25/26perameter show nahi ho raha kya karo
Nice vedio
Pl send speed meter connection & pash button frequency increase decrease
Hello namaskar sir mera agarbatti machine ka l&t cx2000 hai isme baju relay hai relate to DC box mein supply hota????? Sar aap ka MI number de sakte
Push button se speed increase decrease Kai hoga
Lt Sx 2000 drive mai run karne pe poe aata hai means what sir fault kya hai yeh
Output phase loss ki error he motor connection check kijiye.
Sir sikhane k saath manual ka link b share kiya kro
L& T sx 2000 ka really out put ka parameter batate to acha hota....
Sir full siting darav video milega sir
Good man
Sir agar push button se frequency up down karna hoto wiring kese karenge
Set any digital input for frequency up and another for speed down and set frequency on up/down command by viewing in manual.
@@niceelectronics9505manul nahi hai tu kya kare
Jog connections or parameters bta dete sir
Jog or inching mode
7.5 kw me fan kitne ampear ka lagta he
very helpful video
Sir A1 B1 C1 ka use kaha karte hai plz
Cx2000 & sx2000 what is different
good
Thank you❤❤❤ bhai
Px2000 main flat aa raha hai oc2 iska matlb kya hota hai
Cx 2000 low voltage problem parameter settings bataye
Sx2000 push button and pot wiring
Hamara jo vfd hai usme na vfd se supply nahi aa raha hai star push me
👌👌👌👌
Auto me kese chalaye cx2000 VFD ko
Please update full list of parameters list discrimination
VFD sx 2000 Errc alarm problem
?
Cx2000 se RPM metre mein power Safai kaise
on /off pB ka conntion kese kare
Sir Humari v yahi VFD he bo kabhi on hoti he kabhi nhi hoti , display lite v nhi jalti supply puri mil rahi he VFD ko
Connection check karo push battan khrab huga
Sir aap jo drawing kiya osi ka ak photos ka PDF chaiya . please send kor dejiya .
Good👍
Sir my vfd ka start button hold nahi hoga
nEC fault please solve.
Pls share connection and parameter
Vfd fhalt kyu hota h or fhalt ko thik karne ka upay batay
Bhai sx200
Fan error kai se reset kare
Agar apki vfd ka fan on off sahi tarah se ho raha he to ..then set H78=0 FAN ki error chali jayegi
Drc me F kaise kare
I 19 me 17 karne ke baad bhi push button not working
Mere vfd mein ek bahut bada problem ho raha hai vah solve hi nahin ho
Please help me sir
Kya problem a raha he.?
Aapke likhe hue parameters saaf nhi dikhai dete hai
HOE drive me likh jata hai our machine band ho jata hai kyo
Vfd konsi he and uska model no send kijiye..
Apke what's up number mil skty h... Mere pas b h... Parameter.. Reverse vala switch chahiye... Or on /off switch... Leg side me dena h... To help chahiye bhai... Plz contact no. Do..
Sir
Good evening
Please make a video of Sx 2000 model for 2-wire configuration with parameter and wiring connection.
If possible kindly share the contact no.and email id
Thank you
Bhai pdf de do
Est error what
Sir auto me 4 to 20mA or manual me pot se kar ne ke liye kon sa parameter aayega
Please must reply
9714090417 wp
Set any digital input from I17 to I21 to 22 and set drv2 and frq2 for second source operation.
Sir same prob.mera hai.analog input 4 to 20 dena hai plc auto me.kaha de sakte hai....
Sir aapke Mobile no mil jayange kya
Please reply
ap Mobile Number send kar do sir
Sir aap apna whatapp number dejeye na thora problem hai
Sir pawer off hone k pawer aane se auto start kaise hogi cx2000 paemiter bataye g
on Off indicican ka conntion kese kare
Three wire k connection hi on off hai video dekh Lo