Nice video! Replying to the main question on the comments: one of the advantages of the OxiTop is that it doesn't require sample dilution! On the closed bottle or dilution method the only oxygen available is dissolved in the water, so it's rather limited, thus even relatively low BOD samples may require dilution to avoid depletion during the 5 days. On the OxiTop there is also oxygen on the headspace which allows direct determination of BOD up to 4 000 mg/L or even 400 000 mg/L. The sample volume is now chosen depending on the expected BOD, allowing more headspace if needed, instead of diluting the sample. This also allows easier adaptation to long BOD (several months) or respiration applications and even anaerobic processes. Also there is no need to prepare multiple bottles to determine different intermediate results in addition to end point.
Cordial Saludo, Estoy intrigado, por que no usaron agua de dilucion, o fue mezclada con la muestra previamente y en que cantidades? Gracias por el dato
Buenas tardes. La finalidad del vídeo es explicar en forma general el método de la determinación del DBO utilizando el "oxitop". En el manual de usuario del fabricante, se indican los detalles técnicos específicos, incluyendo las concentraciones de los reactivos.
Saludo cordial, muchas gracias por el vídeo, pero me surge una duda y es la siguiente. Porque razón NO se utiliza agua de dilución? porque se supone que debe tener los nutrientes necesarios para llevar a cabo la degradación de la materia orgánica durante los 5 días muchas gracias.
para dbo bajas creo que no se usa agua de dilución, en el equipo de mi universidad, (marca velp)se usa agua de dilución para mas de 900 de dbo, saludos.
Nice video!
Replying to the main question on the comments:
one of the advantages of the OxiTop is that it doesn't require sample dilution!
On the closed bottle or dilution method the only oxygen available is dissolved in the water, so it's rather limited, thus even relatively low BOD samples may require dilution to avoid depletion during the 5 days.
On the OxiTop there is also oxygen on the headspace which allows direct determination of BOD up to 4 000 mg/L or even 400 000 mg/L. The sample volume is now chosen depending on the expected BOD, allowing more headspace if needed, instead of diluting the sample.
This also allows easier adaptation to long BOD (several months) or respiration applications and even anaerobic processes. Also there is no need to prepare multiple bottles to determine different intermediate results in addition to end point.
Excelente video, me despejaste muchas dudas, se agradece muchisimo..
Cordial Saludo, Estoy intrigado, por que no usaron agua de dilucion, o fue mezclada con la muestra previamente y en que cantidades? Gracias por el dato
excelente aporte
Muy útil!! Gracias!!!
Al obtener los datos cual sería mi DBO real?
amigo, buen video, ayudame con una pregunta, luego de obtener estos resultado en ppm de o2, cómo se realiza una gráfica?
SALUDOS
Gracias
Buenas vídeos, tengo una pregunta cual es la concentración de hidróxido de sodio que se coloca en el capuchino .
Buenas tardes. La finalidad del vídeo es explicar en forma general el método de la determinación del DBO utilizando el "oxitop". En el manual de usuario del fabricante, se indican los detalles técnicos específicos, incluyendo las concentraciones de los reactivos.
lopezjavierucv@yahoo.com Gracias por su respuesta
@@lopezjavierucvyahoocomalguna recomendación para la determinación de COD?
Saludo cordial, muchas gracias por el vídeo, pero me surge una duda y es la siguiente. Porque razón NO se utiliza agua de dilución? porque se supone que debe tener los nutrientes necesarios para llevar a cabo la degradación de la materia orgánica durante los 5 días muchas gracias.
para dbo bajas creo que no se usa agua de dilución, en el equipo de mi universidad, (marca velp)se usa agua de dilución para mas de 900 de dbo, saludos.
la proxima vez le dice a las señoras...que hagan silencio...
chapulin colorado 179
Cous los oues
Cous los