How To Permanently Remove A Zone That's Not In Use Anymore.

Поделиться
HTML-код
  • Опубликовано: 4 янв 2025

Комментарии • 30

  • @randyaivaz3356
    @randyaivaz3356 2 месяца назад +1

    Another Way if Between 1 and 16.
    Enter Programming, Go To Location 101, Scroll Through the Digit String, Enter 00 for Zone You Want Eleminated.
    If a Wireless Zone, Enter Programming, Go to Location 804, then 82 For Zones 1-8, 83 for 9-16 And So on. When You Press 82, 1 through 8 mabe be indicated if Active, Press 7 So #7 turns Off. Is Now Inactive.
    ## To Exit Programming.

  • @bobicard2503
    @bobicard2503 4 месяца назад

    Thanks, good video... Do I remove the wire that's in the com slot that has a resister on it when I put in the jumper?

    • @JasonTech
      @JasonTech  4 месяца назад

      Q. Do all your zones have resister on them?

    • @bobicard2503
      @bobicard2503 4 месяца назад

      @@JasonTech Yep...

    • @bobicard2503
      @bobicard2503 4 месяца назад

      every com slot has a resister, but not every zone has a com slot...

    • @JasonTech
      @JasonTech  4 месяца назад

      Put the other end of the resister in the zone.

    • @bobicard2503
      @bobicard2503 4 месяца назад

      @@JasonTech So, I should snip the resister wire that is attached to the com wire and put the sniped end into the zone slot? Correct?

  • @rebekahmack1207
    @rebekahmack1207 6 месяцев назад

    Thanks, very helpful. Worked great.

  • @TheHowieM
    @TheHowieM 10 месяцев назад

    If I don’t know what zones are connected to the doors and windows, how can I find the zone number corresponding to each location?

    • @JasonTech
      @JasonTech  10 месяцев назад

      Have someone open a zone (door/window) and a 2nd person to check the keypad.
      2nd way is to tone out the wires.

    • @TheHowieM
      @TheHowieM 10 месяцев назад

      @@JasonTech Hey Jason. Thanks for the quick response. I did try that, opening the front door next to the device. It displays "Front Door," but not a number. I'm trying to find the number. Then I realized the zones are displayed in order. So I can get the numbers now by counting as I scroll through the zones.

    • @JasonTech
      @JasonTech  10 месяцев назад

      What keypad model do you have?

    • @TheHowieM
      @TheHowieM 10 месяцев назад +1

      @@JasonTech 9057. I figured out the zone numbers by going to the bypass menu and scrolling through the locations. So I'm all set! Thanks.

  • @apngo88
    @apngo88 2 месяца назад

    What resistor do I need to buy?

    • @apngo88
      @apngo88 2 месяца назад

      The zone still shows as open when I use a wire as a jumper

    • @JasonTech
      @JasonTech  2 месяца назад

      It should be a 512

    • @JasonTech
      @JasonTech  2 месяца назад

      Sound like you have EOL resistors.

    • @apngo88
      @apngo88 2 месяца назад

      @@JasonTechYou rock Jason. Works like a charm!

    • @randyaivaz3356
      @randyaivaz3356 2 месяца назад

      5.6K, 5600 Ohms,
      Green/Blue/Red, Gold for 5%
      If Homeowner and Putting Resistors in Panel, May as Well Program Closed Loops, Not EOL.

  • @rachelelsner5195
    @rachelelsner5195 6 месяцев назад

    Is the installer code the same as the master code?

  • @raj-qc8xv
    @raj-qc8xv 11 месяцев назад

    Hi bro we have two zones error change pir but arming pad in issue same pls give suggestion

    • @JasonTech
      @JasonTech  11 месяцев назад

      You changed the motion?
      Do the motions light up?
      Do you have EOL?

    • @dudleycrotz7374
      @dudleycrotz7374 11 месяцев назад

      I have zone 1 as the entry door to our church and in the entry area facing the door a zone 2 PIR. I programmed section 1 with an entry delay of 30 seconds, the middle delay 90s and the exit delay 45s. Here is the challenge. When arming and disarming with the remote control there is no alarm when entering. However if I don’t use the remote, both zone 1 and zone 2 sets off the alarm when entering as if there is no delay programmed. Any assistance will be appreciated as the armed response keep calling when people with access codes enter and the alarm is triggered on entrance. Thanks

  • @Mr.ShotTV
    @Mr.ShotTV 7 месяцев назад

    How to you rearm a permanently bypassed zone?

    • @JasonTech
      @JasonTech  7 месяцев назад

      You can't, you will have to bypass then arm each time. The best thing to do is to remove the zone if you don't need it.