I have 15ltr crompton gyser. I also have low water pressure pressure. NRB is already installed in my gyser. Water properly enters my gyser but the output pressure of water is extremely low. What should I do.
Thanks sir ये जो डब्बी वाली एल्यूमिनियम की गोल छोटी 75°c वाली थर्मोस्टेट जो गीजर की बॉडी के बाहरी साइड चिपकी थर्मोस्टेट का टेम्परेचर 35°c पर केसे करे वो वीडियो दीजिए
Agar 1 HP ka pressure pump ghar me use karte hain to kya yeh tarkeeb kamyab hai ? Kyonke kai baar zaroori nahi ke hum pump ko lagatar chalaate rahen us waqt notmal cercuit water pressure hi hoga
@@neerajnimTech coz spring works with heating pressure of Gyser . It reduce to extra pressure when thermostat not works. Thats Why it is called to safety walve. It saves to Gyser from blast.
@@MohdTahir-yu9mj this spring work for NRV so the water does not flow back from input pipe. Pressure valve is above level in NRV spring. So pressure valve will work as it is . Spring does not play any role in pressure valve to release pressure.
@@MohdTahir-yu9mj please do not get angry...I just explained technical aspects .... Company is not fool ...All NRV works same and has spring for NRV So it gets closed automatically and only opens when there is a input water pressure and with low input pressure or no pressure spring keeps it closed. In case of single NRV used in gyser has two valve one is for water pressure and second is pressure release valve it also has spring and video creater has not removed that spring. He has only removed spring of water pressure valve.
This is not only NRV, but it is multi function valve. In normal case it stops water flowing back. But in case of failure of thermostat geyser will not trip and it will create high pressure in geyser due to vaporization of water, in that case water vapor pressure becomes more than spring tension pressure and steam will be came out from that valve. Which will be save geyser from blast.
Maine khud apne gyser me water level banaa kar relay se connect karke power geyser me diya hai.. jab bhi pani level se kam hota hai gyser band ho jata hai....😂 25 saal purana gyser hai...
Apne accha jugar bataya.. Ye information humare bohot Kam ki hai..
Spring nikalne se pressure release hone mai koi dikkat to nhi aayegi
It's really very useful technique.... thnx a lot brother....it's got working
Welcome 👍
bht badiya bhai..sch mn kaam ki video..log ulte sidhe cmmnt krege pr apki video sch mn kaam ki h..jai hind bhai
Tq
Great information ❤ sir ji
Very nice and realy kaam ka video hai thank you bhai
Is it safe to remove spring or may cause damage to the gisser
bhai bahut badiya meri geuser ke problem sol kar de thanks
😍
Acha bataya aapne
😊 Very good 👍
Good job bro, but is there any harm if we remove spring?
I have 15ltr crompton gyser. I also have low water pressure pressure. NRB is already installed in my gyser. Water properly enters my gyser but the output pressure of water is extremely low. What should I do.
Koi solution Mila kya ? Same problem h shower nhi chalta bhai
Muje lagta hai ki jo gyser service vaala hai usko ak baar pu6 lena chaahiye kyonki ye Non returning valve ke sath saath safety valve hai so
Thanks sir
ये जो डब्बी वाली एल्यूमिनियम की गोल छोटी 75°c वाली थर्मोस्टेट जो गीजर की बॉडी के बाहरी साइड चिपकी थर्मोस्टेट का टेम्परेचर 35°c पर केसे करे वो वीडियो दीजिए
Thank you so much sir...🙏
Very useful information
Khilane ke liye clock wise ki anti-clockwise wise?
यही टेक्निक मैंने वाटर पंप में लगाया था।NRV का स्प्रिंग निकाल दिया था।छत की टंकी जल्दी भर जाता है। आज़माके के देख सकते हैं!
Very good and informative
Bahut badhiya video. Dhanyavad.
Agar 1 HP ka pressure pump ghar me use karte hain to kya yeh tarkeeb kamyab hai ? Kyonke kai baar zaroori nahi ke hum pump ko lagatar chalaate rahen us waqt notmal cercuit water pressure hi hoga
Aisa nahe ho skta sir
Sir mere nrv me spring nikalne ka sistam nahi hai spring nikalne wali nrv kahan milegi
Hi kya aap iska product link de sakte h ? Muje ye hi wala kharidna h
Spring ka use kya hai .
Please details me bataaye?
Bhai isme jo beach me ek aur pipe ka ched bna hua hain usme se gisyer on krte hi pani tap tap girne lgta hain to kya kre
Video banaunga fir samjh Lena.
THank you bhai main 2 din se pareshan tha.
mera dusra type ka hai yeh upar se nahi khulta kya karoon?
Sir aapki video to bahut achi but ye nrv plastic wali mil hi nahi rahi h iske ander wale part lohe ke jo khulte hi nahi h
ऑनलाइन मिल जाती है
Racold online geyser ka spring nikal sakte kya
Thank you sie, nice information.
Nrb hot side lagate h ya cold side
Cold side
Lekin sir ye batayn ki isse gyzar ko to koi khatra nhi jese phatne ke chanc kuch
Nahe
mai ja rha hu try krne agar presure bda to aap ki video like krunga or subscribe bhi
Very good idea sir thank you so much
So nice of you
Kya bina nrv ke geyser chala sakte he kya sir
Sir Jo pehle ke geyser hai wo chal skte hai.
Good work sir ji 👍🎉🎉😊
You convert this safety walve to a danger walve ...💥
explain how?
@@neerajnimTech coz spring works with heating pressure of Gyser . It reduce to extra pressure when thermostat not works. Thats Why it is called to safety walve. It saves to Gyser from blast.
@@MohdTahir-yu9mj this spring work for NRV so the water does not flow back from input pipe. Pressure valve is above level in NRV spring. So pressure valve will work as it is . Spring does not play any role in pressure valve to release pressure.
@@neerajnimTech then why company is giving spring in this walve ? Is they're fool ?
@@MohdTahir-yu9mj please do not get angry...I just explained technical aspects .... Company is not fool ...All NRV works same and has spring for NRV So it gets closed automatically and only opens when there is a input water pressure and with low input pressure or no pressure spring keeps it closed.
In case of single NRV used in gyser has two valve one is for water pressure and second is pressure release valve it also has spring and video creater has not removed that spring. He has only removed spring of water pressure valve.
Very good suggestion. Thank you sir.
This is not only NRV, but it is multi function valve.
In normal case it stops water flowing back. But in case of failure of thermostat geyser will not trip and it will create high pressure in geyser due to vaporization of water, in that case water vapor pressure becomes more than spring tension pressure and steam will be came out from that valve. Which will be save geyser from blast.
Is it ok to remove that spring?
Sir hawells me nhi he yh sytem kys kre ab
Thank you sir👍💯
Magar iss mei toh metal ka laga hota hai....pehle woh kaise khole??
Awesome jugad…thanks👍🏻
Good working bro Thanku
Thank u so much sir very useful information
Dusre type ki nrv ki spring kaise khole
Thank you sir for simple trick
Very good idea 💡
Very helpful
Good job sir
Very good
Good yar thanks
Information toh sahi hai par spring ko nikalne se safety kam nhi hogi kya?
Safety ? Explain please
Nice information
Thanks
Bhai input or output sahi kaam kar Rahi hai par nal me pani nahi aa raha kya karu
Nal ko thodi der khula rehne do
Sir geyser se thanda pani nikal Raha hai garam nahi kaise theek kare
बहुत जल्द वीडियो आएगा इस टॉपिक पर
Spring is there for safety so that valve dont get stuck halfway due to dirt
Only take out spring if You have low pressure problem, the spring is there for safety reason.
Yes
गजब
Good 👍👍👍👍 video
Bhai hamare ao Smith geyser me light nahi aa raha hai
Very💕👍🙏
Thank u ❤
Itna time kaha rehta h bhai mekenik ke pass😊😊😊😊😊
Appreciate ❤️
Excellent
Ye safety ke liye hai
Nice
Good idea. Thanks.
Spring hatane se koi nuksan to nahi hoga
Koi nukshan nahe hoga sir
अगर पानी का प्रेशर कम होगा और स्प्रिंग रहेंगी तो पानी गीजर में नहीं चढ़ेगा।
Idea to bahut achchha hai magar koi disadvantage to nahi hoga na ?
Nahe sir agar Pani ka pressure Kam hai to ye kaam karna hai ।agar pressure thik hai to koi problem nahe hai।
Spring Nikalo mat wire cutter lo or us spring ke 1/2 line cut kr do Pressure thoda loose ho jayega or bina spring nikale hi kaam bhi karega ✅
Why spring given by company ?
sir mere Geyser ka safety valov Tut gye haii kiya kru
Naya bhi mil jata hai
Gas welding bhi ho jati hai .
Condition ke hesab se
@@Devbhumitech sir open ho jata haii mere Geyser 2020 model Bajaj skti plus hai
Sir kholte time galti she crak ho gye mere she chng ho jye gye
Good
Maine khud apne gyser me water level banaa kar relay se connect karke power geyser me diya hai.. jab bhi pani level se kam hota hai gyser band ho jata hai....😂
25 saal purana gyser hai...
नल का प्रेशर कैसे बढाई
Desi Computer 🇮🇪🙏🙏🙏🙏 u bro
Thank you
CLockwise not ant-clockwise
Dono nrp nikane se hoga
Nrv ek he hoti hai geyser main
thanks you very much.
Welcome sir
V.g 🎉
clockwise aur anti clockwise bol rahe ho lekin kar ulta rahe ho, sahi baat kya hai??
mai ja rha hu try krne
Ye NRB nahi NRV(Non return valve) banado
Thanks
🎉🎉🎉🎉🎉🎉
TNX brother
Verigoid😊😅😅
Ye valve alag hai
Atleast btaya usne
Springs ko thora Kat k lagaw
👍👍👍👍👍👍🌹🌹🌹🇮🇳🇮🇳🇮🇳♥️♥️♥️
नहीं आ रहा है इधर
Vedio selfi camera se bnya hi.. ulta dikhta hi..mirror ki tarh
Bhai shi bol rha hi
Tax sir
खोलना तो बताया नही ये किधर होता है
NRV not NRB. NON RETURN VALVE
गलत बोले भाई.घ़डी की दिशा को क्लाॅक वाॅइज़ कहते हैं और घड़ी की उल्टी दिशा "एन्टी क्लाॅक वाॅइज़" कहते हैं!!!
Sahe pakde hai
Sale baat pakad raha hai 😂😂😂
Video reverse hai
Selfi camera se ulta dikhta hi
Isliye vah bhai shi bol rha hi
Vedio selfi camera se bnya hi.. ulta dikhta hi..mirror ki tarh
Bhai shi bol rha hi
Pehle aap khud samajh le phir samjhaye please ue spring kyu
lagti hai shayad aap ko nahi malum. I am really sorry to say that.
NRB =NRV🤔🤔🤔🤔🤔
NRV
Bhut risk hoo jata hai isko छेड़ो gey तो 👍
Spring Nikalo mat wire cutter lo or us spring ke 1/2 line cut kr do Pressure thoda loose ho jayega or kaam bhi karega ✅