Hammond M-100 Organ Restoration (Part 3)

Поделиться
HTML-код
  • Опубликовано: 2 фев 2025

Комментарии • 12

  • @nickwagner4563
    @nickwagner4563 8 лет назад

    hi,
    i love your restoration series! i am from germany, i'm 16 years old and have a m100 myself!!! i love this sound and this instrument! its amazing. thank you very much.

    • @DaveElectronics
      @DaveElectronics  8 лет назад

      Hello Nick, i really appreciate that!thanks for the kind comment and keep rocking with your m100, it's a really wonderful instrument!
      Dave.

  • @hifijohn
    @hifijohn 8 лет назад +1

    the motor and gears are suppose to be on a spring mounted assembly, I have a M3 and it runs pretty quitely.

    • @DaveElectronics
      @DaveElectronics  8 лет назад +1

      Yes, the whole generator assembly is suspended by springs, even the flywheel has a spring to maintain the rotation constant. Such attention to details is simply amazing..

  • @user29873
    @user29873 8 лет назад +3

    You cannot just stuff an new oil wick into the scanner. This wick has to be properly attached to the according bearing. you have to completely disassemble the scanner, drill out the rivets, remove the bearing, attach new cotton wicks and reassemble the whole thing.
    The same applies to all other wicks, that have to be replaced.

    • @user29873
      @user29873 8 лет назад

      knotting new wicks to old ones is ok. 👍

  • @primotripi8388
    @primotripi8388 3 года назад

    Perché non è in italiano? Prego provvedere grazie ciao.

  • @dgoeppert
    @dgoeppert 8 лет назад

    Hello, I have a problem with a M100 ... I was wondering what the problem is on that..
    ON THE TOP KEYBOARD
    DRAWBAR NUMBER KEYS NOT WORKING
    1 2nd A+D+E 3rd A (Coming in and out)
    2 1st G+A 3rd F# B 4th F# B
    3 1st A+D+E 3rd A# 4th F#
    4 1st C(noise) 3rd F#
    5 2nd B
    6 2nd F#
    7 1st D
    8 1st B
    9 1st F#
    ON THE BOTTOM KEYBOARD
    DRAWBAR NUMBER KEYS NOT WORKING
    1 2nd A+D+E
    2 1st A+D+E 4th F#
    3 1st A+D+E 3rd B
    4 3rd F#
    5 2nd D
    6 2nd B
    7 2nd F#
    8 All working but weird harmonics on every key.?
    (All the 1st ,2nd ,3rd and 4th refer to where they appear on the keyboard. As in the 1st C is the lowest C.)
    The foot pedals are working fine.

    • @DaveElectronics
      @DaveElectronics  8 лет назад

      Hi! As i understand there are some notes not working on multiple drawbars, so i suspect that the problem is in the generator.. Perhaps some tonewheels are stuck? This is a problem that likely occurs when the organ is not properly oiled or has been off for a long period of time. The first thing to do would be to check visually the generator (and its wiring) and try to see if all the gears are turning (try to raise the gen. and feel the wheels with your finger). Let me know,
      Dave

    • @dgoeppert
      @dgoeppert 8 лет назад

      Thank you sooooooo much :-) I check that soon and let you know !

  • @tracyeaves4847
    @tracyeaves4847 4 года назад

    Use some gun coat by Flouramics Tuf Oil....it will quiet down, you will never have to lubricate again

  • @James_Bowie
    @James_Bowie 3 года назад

    Cotton threads, not wires.