Assalamo alikum Kiya haal hy Aap sub ka bahut achi video banaty Aap AK baat batain k R12 ki bajahy R 134 daal sakty hain is say koi problem tow nahi hogi aur R600 k bary main bi batain
I have whirlpool refrigerator in that due to low gas pressure, compressor head gasket got burnet out. I have replaced the gasket and checked the pressure and it's giving 500 pressure in 12 seconds with around 0.4 amps. Now when gas is charged sometimes compressor got verymuch hot. I checked the temperature of compressor and was 57 degrees at that time. Please let me know if this under limit or its very high. Earlier it got overheated because defrost water bucket was broken and there was no water to cool the pipes.
Aaj same process se repair karaya hai lg double door fridge me. Cost lagi 2k..ek info confirmation ke liye janna chahta hoon, r134a ko load kiya vaccum ke baad 10 point vaccum dial gauge par aur fridge me requirement 120gm ki hai, to technician ka kahna tha ki 10 par needle aane par approx 120gm gas ho jayegi. Kya ye baat sahi bola unhone?
I have a double door Samsung Fridge of 350litres model. As it was not cooling Called a technician. He said there is no Gas and filled the latest IsoButane Propane gas . After 2 days again the cooling stopped. He came back and said the condenser is leaking and fixed a new condenser externally on the backside. Now again the fridge worked for two days well and stopped. It appears the compressor is working the evaporator fans are working as we can see the airflow. When we called the technician he says it could be the evoporator coil. He hasn't come so far due to lockdown problems. What could be wrong with this fridge. I have already spent about 5000K on this so far. Is it worth changing the Evaporator now? Though the fridge is very old the body and interior are as good as new. Can you suggest what we can do? Thanks in advance!
maybe a leakage in evaporator capillary joint they fix a locking on it. tell him to solder it no need to change the evaporator, don't pay for this it is his job to complete it
thank you, waiting for that, there is absolutely no video/ information on the net about how the condenser coils are concealed in between the side walls & the plastic inner body.
Sir ek duel door frij h jall ,caplery, comepresr sb chang kr lea jall pura heat h, wapsi pipe pr bhi moschsr aaya hua h pr brub nhi jumb rhi h kya kru please.. Help me
Sar capillary ice jamati hai 1 line pay Baki line Thandi Nahin Hoti Hai double door fridge capillary Badal Dali hai compressor naya dala hai kya problem ho sakta hai
At point 2:11, you show an ingenious way to connect two sections of capillary tubes. Is there a possibility of the refrigerant expanding/changing state while in the small section of copper tubing that is used to join the two capillaries, just as the refrigerant expands/changes state when the capillary empties the refrigerant into the evaporator? It would appear that the refrigerant would change state when entering and when exiting the adjoining copper tubing.......Or is that section of adjoining tubing not long enough to make a difference? Thanks.
yes, the refrigerant will expand. for that reason, I placed that joint inside the freezer section. there will no difference in a cooling effect. still that fridge working perfect till now
Hello there, could you please send me some details about that brazing torch and material you use For brazing, because regular oxy brazing tanks are very expensive here in North America. And also could you please let me know about that cheap liquid you used in one another video to stop leaks in refrigerator because those are very expensive here too. Really appreciated and thank you.
I use this torch. amzn.to/2WNZ6e0 if u want to buy from me. I can ship to ur country. for brazing, I use the copper brazing rod. can u share the link to my video where I stop leaks
Sir, mera ek problem lg ka refrigerator compressor bahut garm hotta hei thandabi thik nahi he eska kharbi kya ho sakta hei yara mehrubani karke batayia
sir Je back pressure sab freeze ka same hota ya alag alag agar alag hota h to kaise pta lgega humko Ki is freeze ka back pressure kitna rakhna h please ye bta Dena sir
thnq sir 4 dis video...sir mera fridge ko chutehi jhatka lagta hain ..aur fridge ki body main tester laga ke dekha to pura ligt jal raha hain tester ka..to is problem ko kaise solve karu pls bataye sir..thanqq
Sir same fridge hai.. Isme sab kuch sahi chal raha lekin evaporator coil ke neeche ice jam ja rahi jisse fridge ko jane wali hawa block ho rahi.. Heater timer bimetal sab kuch sahi chal raha kya kare?
Sr please reply double door fridge gas charge krne ke baad 2,4 din hi cooling krta hai dheere dheere cooling km hone lgti please ... Solve this problem
Super Sir ekadam perfectly Sar mujhe vah ek baat bolna hai ki aluminium ki cooling coil direct bhi Ham connect kar sakte hain na FIR aap direct connect Kyon Nahin kiye 2 Sir Mujhe copper pipe kaun kaun sa Hota Hai aur Sir size Mujhe batayenge kya aap
direct bhi laga saktey hain. per merey pass us time aluminum rod nahi tha. copper pipe kai size main aatatey . aap flaring tool per dek saktey hain pipe kay size
Sir mera samsung ka double door fridge hai bar bar stener,condenser , leak ho raha hai tu main isbaar cooling coil bhe change kar do Cooling coil abhi leak nhi hai Sir job repeat ho raha hai Isliye Fir Cooling coil repeat na hu Future main Kya better hai plz help sir
Sir mere double door samsung fridge mein upar cooling ho rahi hai lekin lekin niche nhi ho rahi..... Kitne bhi din kitni bhi der tak on karke rakhne se tab bhi cooling nahi ho rahi or ye problem niche hai upar nahi hai.... Upar ka Part okay hai..
woh, heater agar kharab ho jaye to oh replace kaise hota hai, oh alag sa milta hain market main yah pura coil change karna parega please reply me or call me sir.
Hello. Is there a particular reason why you rolled up and left the excess capillary tube on the refrigerator, instead of cutting it off shorter? Thanks.
Capillary lengths should be 8-9 feet's its design for efficient cooling. excess capillary should be rolled up, if we cut excess capillary there will be not proper cooling.
Very good. Mere ustad. Bahut malumat mili. Bahut sukriya. Very nice.
THANK YOU
Sir ham ne pahli baar itna finishing se kaam dekha
same tutorial content. thanks, the video is very useful for those who are just learning
Saab aaapka bahuth shukriya ,, allla aaapku bahuth khush rakhe ameen!
I am srilankan technician. Very helpful and skillful presentation thank you sir.
You are most welcome
sir app bohoth achey smjatya hin hr vedio my
Assalamo alikum Kiya haal hy Aap sub ka bahut achi video banaty Aap AK baat batain k R12 ki bajahy R 134 daal sakty hain is say koi problem tow nahi hogi aur R600 k bary main bi batain
r12 kay compressor main aap ko oil change karna padega 134 ka oil daal kar 134 gas dalna hai
Aap best technical teacher ho saab
Thanks very clear job welldone sir?haydrabad
बहोत हि अछि जानकारी आपने इस वीडियो में दी है थैंक्स
I have whirlpool refrigerator in that due to low gas pressure, compressor head gasket got burnet out. I have replaced the gasket and checked the pressure and it's giving 500 pressure in 12 seconds with around 0.4 amps. Now when gas is charged sometimes compressor got verymuch hot. I checked the temperature of compressor and was 57 degrees at that time. Please let me know if this under limit or its very high. Earlier it got overheated because defrost water bucket was broken and there was no water to cool the pipes.
compressor heats not a issue
Sir isme 31 no capillary tube dal sakte he
31 or 36 koi bhi laga saktey hain
sir aap is ma leaking check Karna ka Lea kitna air presser data ha...
150 say 170psi
Great technique with torch.
Thank you! Cheers!
Bhai apane inverter ac me likeg chek karneke liye fridge ke compressor se pressure barsakatehe kya?
haan bhar saktey hain.
Ha Bilkul bhar sakte he
Aaj same process se repair karaya hai lg double door fridge me. Cost lagi 2k..ek info confirmation ke liye janna chahta hoon, r134a ko load kiya vaccum ke baad 10 point vaccum dial gauge par aur fridge me requirement 120gm ki hai, to technician ka kahna tha ki 10 par needle aane par approx 120gm gas ho jayegi. Kya ye baat sahi bola unhone?
Sirji agar internal condunser karab ho jay to sumsung doule door freeze mein tab hum kya upay karenge sir please batayega
bahar laga dena hai condsor body wala disconnect kar dena hai
Ok sir thank you🙏
I have a double door Samsung Fridge of 350litres model. As it was not cooling Called a technician. He said there is no Gas and filled the latest IsoButane Propane gas . After 2 days again the cooling stopped. He came back and said the condenser is leaking and fixed a new condenser externally on the backside. Now again the fridge worked for two days well and stopped. It appears the compressor is working the evaporator fans are working as we can see the airflow. When we called the technician he says it could be the evoporator coil. He hasn't come so far due to lockdown problems. What could be wrong with this fridge. I have already spent about 5000K on this so far. Is it worth changing the Evaporator now? Though the fridge is very old the body and interior are as good as new. Can you suggest what we can do? Thanks in advance!
maybe a leakage in evaporator capillary joint they fix a locking on it. tell him to solder it no need to change the evaporator, don't pay for this it is his job to complete it
Excellent information sir I like your all videos 👍
Dear sir what's your opinion about using Anti moist chemical in to refrigeration system?
Using anti moisture will solve the chocking problem
Hi sir u had any portable brasing troch it it's there please share the link
check video description a link provided
Very nice my LG company technician
Very nice
very nice video I have sumsug chok PCB refrigerator double door compressor pumping 400 pisg only, isn't right .
Yes, correct
Sir your video was good.
But what is the back pressure of r134a refriherant....?
Priyam Biswas 5 psi
Amit Biswas 10 production pressure . Standing pressure 75 to80
Sir jo thandie karne wallamay ek pipes sa hai jo red colour ka wire hai jo condenser jaisa delta hai woo kya hai
wo defrost heater hai
Very Good video. You know your stuff. With Patience its fixed!
Thanks! 👍
kya aap fridge ke side wall me condenser coils kaise factory fit hoti hai, consealed fridge me.
Is per video jaroor banaunga
thank you, waiting for that, there is absolutely no video/ information on the net about how the condenser coils are concealed in between the side walls & the plastic inner body.
Sir ji hum window ac ki pcb mai se capacitor ko nikal ke uske jagah fridge ke capacitor lagake fridge compressor chala sakte hai ki nahi
capacitor easily mil jatey her number kay fir kyon AC ka nikal kar lagao gay.
Sir, jo aapne bhi kiya iska kitna khatcha aata hai with gas refling
2500rs tak ka
Very good video.
Thank you very much!
Sir ek duel door frij h jall ,caplery, comepresr sb chang kr lea jall pura heat h, wapsi pipe pr bhi moschsr aaya hua h pr brub nhi jumb rhi h kya kru please.. Help me
Aap mujey whatsapp karo 9848461408 per
Sar capillary ice jamati hai 1 line pay Baki line Thandi Nahin Hoti Hai double door fridge capillary Badal Dali hai compressor naya dala hai kya problem ho sakta hai
Sahi vacuum karo new capillary dalo
good job sir and clear work
Keep watching
Sir ji delhi mai koi special shop jha par yeh torch or cylinder mil sakay pl reply mai serch kiya laikin mil nahi paya pl reply from Delhi
mil jathi hai spare shop main. delhi ka idea nahi
At point 2:11, you show an ingenious way to connect two sections of capillary tubes. Is there a possibility of the refrigerant expanding/changing state while in the small section of copper tubing that is used to join the two capillaries, just as the refrigerant expands/changes state when the capillary empties the refrigerant into the evaporator? It would appear that the refrigerant would change state when entering and when exiting the adjoining copper tubing.......Or is that section of adjoining tubing not long enough to make a difference? Thanks.
yes, the refrigerant will expand. for that reason, I placed that joint inside the freezer section. there will no difference in a cooling effect. still that fridge working perfect till now
Thanks for the response, and explanation!
Dear sir many many thanks for you
Hello there, could you please send me some details about that brazing torch and material you use For brazing, because regular oxy brazing tanks are very expensive here in North America. And also could you please let me know about that cheap liquid you used in one another video to stop leaks in refrigerator because those are very expensive here too. Really appreciated and thank you.
I use this torch. amzn.to/2WNZ6e0 if u want to buy from me. I can ship to ur country. for brazing, I use the copper brazing rod. can u share the link to my video where I stop leaks
सरजी बहुत अच्छा ,,,, एकदम सुपर
Sir, mera ek problem lg ka refrigerator compressor bahut garm hotta hei thandabi thik nahi he eska kharbi kya ho sakta hei yara mehrubani karke batayia
Gas kam hogi. Check karao.
Sir
Please tell about coil material is aluminium or copper which is used and where
aluminum
i need this evaporator coil. Do you have this new one?
whatapp 9848461408
Hello sir how many type of gas use in refrigerator and back pressure
r600 back pressure 1psi. 134a 5psi, Hydrocarbon 5psi
@@SomaElectricals thank you very much sir
Sir Mai hamesha apki videos ka wait karta hun is bar bhi kuch Naya sikhneko Mila thanx.
Gas kam ho janepar mains current bahot jyada Double ho jata hai kya?
haan hota hai gas kam honey say compressor continue run hota rahta hai
Sir back side me hol Girarte waqt condonsar me liq na ho isame kya khabardari le sakte hai
Hole aaram say karna hai
Aslama alaekom
Sir kya no frost fridge k evaporator ki leaking ko magic epoxy k sath repair kia ja sakta hai?
jada din nahi chalta hai exposy fir leak karney lagtha hai
Thanks 😊
Sir aap great ho sach me
Sir kintne on caplery dalti aur kinti foot dalti h
36 capillary 8 feet
very good video sir. what capillary diameter it uses and how many meters
36 no. And 8 feet
very useful video
Thanks a lot
Isme jo suction line ko black wala insulation konsa lagaya hai
AC pipes per jo insulation hota wahi lagaya hai
sir Je back pressure sab freeze ka same hota ya alag alag agar alag hota h to kaise pta lgega humko Ki is freeze ka back pressure kitna rakhna h please ye bta Dena sir
Single and double door ka same hota hai. 5 psi
Sir jab dabal door m ges dalte h to keplari badalna jaruri h ya nhi
capillary block ho tho change karna padega
Hello , Please tell good frost free fridge and model ?
u can go for LG samsung whirpool
@@SomaElectricals Between Samsung and LG ?
i love samsung design and quality so u can go for samsung. Lg also not bad
@@SomaElectricals Great Thanks
thnq sir 4 dis video...sir mera fridge ko chutehi jhatka lagta hain ..aur fridge ki body main tester laga ke dekha to pura ligt jal raha hain tester ka..to is problem ko kaise solve karu pls bataye sir..thanqq
Aap ghar ka earthing check karo
@@SomaElectricals no
Sir mera luminum pipe say leek ha cvaporater ma cope pipe lga kar godraj aluminium tankaa lga skat ha sir reply
yes laga saktey hain
@@SomaElectricals aluminium. Pipe leek par koi be vedio nahi ha is par poori vedio banaya sir
@@MS-yx1rg ok
Very nice video
Nice video sir Sir aap ke jaisa metre Kahan Milega please sir Jankari dijiye please please
linksad.net/fpKW7gd
owsom it will help very informative 👍thank for sharing
Nice video sir thank you
Most welcome
Thanks sir video buot badiya h
Sir same fridge hai.. Isme sab kuch sahi chal raha lekin evaporator coil ke neeche ice jam ja rahi jisse fridge ko jane wali hawa block ho rahi.. Heater timer bimetal sab kuch sahi chal raha kya kare?
Change the drain heater
Sr please reply double door fridge gas charge krne ke baad 2,4 din hi cooling krta hai dheere dheere cooling km hone lgti please ... Solve this problem
body main condser leak hoga.
Thanks Great observed video channel
Sir 45 minet ya ek gante pesar check karege to ek freeze banane k pura din west hojayega kuch dusra tarika nahi h kya
Sir cooling coil me Jo do red wire hai uska name Kiya hai USKO kaise Nikal te hai
Very nice info
So nice of you
Super Sir ekadam perfectly Sar mujhe vah ek baat bolna hai ki aluminium ki cooling coil direct bhi Ham connect kar sakte hain na FIR aap direct connect Kyon Nahin kiye
2 Sir Mujhe copper pipe kaun kaun sa Hota Hai aur Sir size Mujhe batayenge kya aap
direct bhi laga saktey hain. per merey pass us time aluminum rod nahi tha. copper pipe kai size main aatatey . aap flaring tool per dek saktey hain pipe kay size
Sahi Hai sir thank-you bahut Shukriya aapka
Double door me capallary data kya rahta hai sir
.36 aur 8 feet
Sir aapne jo brezing torch our cen ke bich me kya lgaya he
Main samjha bahi. Aap kis ki baat bol rahey ho
Good information
Thanks
Capillary aur 1/4 pipe Kitna length dalna hai aur guage Kitna rakhna bhai
capillary 8 feet. suction ka pipe ka koi fix lambayi nahi hota. wasay main 5 feet dala
Nice great job .....Keep it up God bless
Es fridge myn defrost heater konsa hy
coil per laga wo hai heater.
I have godrej axix freeze. From top cover and doar lot of Chitty are broken the inside freeze thermacol then how it will repair
Send pic @ 9848461408
Frizer me chaku se hole ho gya he bda...or gas nikal gai he sari..Frize me gas filling karane ka kitna kharcha aayega?
Total kitna kharcha aayega ???
3000-3500 tak new box fixing and gas filling
Sir mera samsung ka double door fridge hai bar bar stener,condenser , leak ho raha hai tu main isbaar cooling coil bhe change kar do
Cooling coil abhi leak nhi hai
Sir job repeat ho raha hai
Isliye
Fir Cooling coil repeat na hu
Future main
Kya better hai plz help sir
condser bhi change karo agar leakage ki problem aa rahi hai tho
Sir mere double door samsung fridge mein upar cooling ho rahi hai lekin lekin niche nhi ho rahi..... Kitne bhi din kitni bhi der tak on karke rakhne se tab bhi cooling nahi ho rahi or ye problem niche hai upar nahi hai.... Upar ka Part okay hai..
sayad uskay defrosting sensor kharab ho gaye hain
@@SomaElectricals khud se sahi kar sakte hain kya agar iska apke pass video hai to link send kar dijiye sir👍
Excellent teaching with performance 👏👏👏👏👏
Sir Jo voh coil pe pink wiring hai coil se jodi voh kya hai
coil per heater hota hai wo heater ka wire hai
SIR, PLESE REPLY KIJIYE IHA PE HEATER KONSA HAI, RED BALE DO WIRE JO COIL KA ANDER GAYA HAIN?
Haan red wala hai
woh, heater agar kharab ho jaye to oh replace kaise hota hai, oh alag sa milta hain market main yah pura coil change karna parega please reply me or call me sir.
Sir how to change heater in same refrigerator (LG double door ) as I couldn't find a physical heater there.Plz reply.
Its thr. Trace hearer wiring u will find
Bhai voh Jo pink wiring hai na coil pe jodi howi wahi hai coil heater hai voh
Sir capillary change jb hum krta hai toh return jaldi aati hai section pr pani chalta iska kya reason hai
gas jada ho tho isa hota hai
@@SomaElectricals hehehehe आधे बेक प्रेशर पर भी सर
Kyo ki nitrogen sabhi jah par nahi lejasaktehe vaccum likeg find out ke bhad me vaccum pump se vaccum kar ke gas( r410,r32) dal saktehe kya?
haan kar saktey hain vaccum
Sir tell about the capillary size and length used
.36 8 feet
Bahut hi good job
Very good
Thanks
Sir 36 no ki capillary apne kitne feet lagai hai aur kitne liter ke fridge me
9 feet
Sir mera 310 litre ka fridge hai 57 no compress hai 36 no ki capillary kitne feet lagaye
@@mohdfaisal6749 9 feet laga saktey ho
Thanku so much sir
Saludos desde Venezuela
thank you
Thanks sir for this video
सर एलजी का डबल डोर पर हम अगर एलजी का न्यू कंप्रेसर लगाते हैं तो उसमें कितनी गैस रिफिल करें
fridge per sticker hota gas ka weight likha hota hai uss hisaab say daal dena hai
Why this patch make alluminium braze directly
Yes we can do Aluminum. I made videos also on this.
Aur AK baat aur bi batain caplari aur refrigerators ko tiner ya petrol ya R22 say saaf Kiya ja skta hy
tinner ya petrol say saaf kar saktey hain. R22 say bhi kar saktey ho
Very good sir thank you sir
Hello. Is there a particular reason why you rolled up and left the excess capillary tube on the refrigerator, instead of cutting it off shorter? Thanks.
Capillary lengths should be 8-9 feet's its design for efficient cooling. excess capillary should be rolled up, if we cut excess capillary there will be not proper cooling.
Thank you very much for the fast, informative reply!
Thanks for videos
Cappllary kitne feet lagayi apne. Esme
9 feet
Sir double door Croma fridge ka cooling coil change karne Mein Kitna kharcha aaega
Nice video sir
Vry 9ce sir.sir yeh jo blow torch ap use kerahe hai wo refilable wali hai ?
Yes. Kabson company ka.
Sir old double door freeze hai usko bio metal lg Ka lagna pir old bio metal ki wire three hai aur new ki four hai how to adjust plz help sir
wiring diagram check karo fridge ki
Sir vo kepillary me joint mare tab 15 rs vala rod chalega ki aluminium ka rod lena padega plz sir reply
15rs wala roda say karna hai