Really High Head Pressure and Coil Looked Clean!

Поделиться
HTML-код
  • Опубликовано: 28 авг 2024
  • In this video I visit a tenant house I’ve been to before because it wasn’t keeping up! #hvacguy #hvaclife #hvac #hvactrainingvideos #airconditioner #heatpump #furnace #hvactroubleshooting #hvacinstall #hvactechnician ‪@ruud‬
    Merch Store : hvac-guy-2.cre...
    HVAC LIFE FB Group: / 521086622906115
    Here are links to the tools I use, It costs nothing extra for you to buy from this list, and it supports the channel:

    Appion Charging Tee: amzn.to/46mRLVg
    Milwaukee 12V Impact: amzn.to/440YLFP
    Ampeak 2000 Watt Pure Sine Wave Inverter: amzn.to/3NCmINT
    Yellow Jacket Tubing Expander: amzn.to/3EvEQnF
    Yellow Jacket 60278 Flaring Tool: amzn.to/3FPjlyY
    Veto Pro Pac Tech MCT Blackout: Amzn.to/3iCieJK
    DeWalt work table: amzn.to/3fKChoB
    Inficon D-tek Stratus: amzn.to/3zNg7IO
    3 Amp Lil’ Popper: amzn.to/3D5lt3e
    Fielpiece SC680 Clamp Meter: amzn.to/33rhxvE
    Fieldpiece SC480 Clamp Meter: amzn.to/33kfgCB
    Fieldpiece SMAN 480 Digital Manifold: amzn.to/3twfVvA
    Fildpiece SVG3 Vacuum Gauge: amzn.to/3udursu
    Fieldpiece DR58 Leak Detector: amzn.to/3nt1TXw
    Fieldpiece JL3KM2 Bluetooth Manometer set: amzn.to/3blMrJR
    Fieldpiece Blutooth Scale: amzn.to/3Gzveab
    Fieldpiece SDMN6 Manometer: amzn.to/3qwk9RP
    Fieldpiece MR45 Recovery Machine: amzn.to/3cUFX5h
    Fieldpiece 8CFM VP87 Vacuum Pump: amzn.to/3qC2wA2
    Milwaukee M12 Impact Driver: amzn.to/37xXkqk
    Makita Wet/Dry Vacuum : amzn.to/3tw4dAL
    DIY Vacuum Attachment for drains: amzn.to/3tDpfNU
    Fieldpiece Smart Probe Kit : amzn.to/34NG3HL
    Klein Heavy Duty Wire Strippers : amzn.to/3I8YNzT
    Klein Needle Nose Crimpers/Stippers: amzn.to/3fuwXlw
    Klein Knee Pad: amzn.to/3cy6FB0
    Klein 7in1 Flip Socket: amzn.to/3bpabwG
    Klein Journeyman Pliers: amzn.to/3tvB60w
    Milwaukee Slim Packout On My Torch: amzn.to/3KeLm3j
    Aluminum Packout Wall Mount on torches : amzn.to/3Kf9hQg
    Milwaukee Tool Box: amzn.to/322iyK9
    Veto Pro Pac Tech MCT: amzn.to/3nwwQdA
    Milwaukee Hook Blade Knife: amzn.to/33F3m5T
    Testo 300 flue gas analyzer: amzn.to/3IcS3Bd
    Western Nitrogen Regulator: amzn.to/3rmdKrx
    Klein Canvas Bucket: amzn.to/3FyzKVf
    Supco Magnetic Door Switch Holder: amzn.to/34IcXcL
    Milwaukee Magnetic Light: amzn.to/3FulCfF
    Milwaukee Rechargeable Headlamp: amzn.to/3nuXsvf
    SS2 Float Switch: amzn.to/3K7LJMW
    3-Amp Breaker: amzn.to/3nxaSXJ
    Appion Valve Core Removal Tool: amzn.to/33CFArw
    Appion G5 Twin Recovery Machine: amzn.to/33Dvd6C
    Yellow Jacket Large Tubing Bender: amzn.to/3qwJv1U
    Similar Small Tubing Bender: amzn.to/3fJsziJ
    Fluke Twist Guard Test Leads: amzn.to/3216R6j
    Fluke 975 Air Meter: amzn.to/3GwD9oM
    Honeywell T-4, 2-Heat, 1-Cool Programmable Thermostat: amzn.to/3qtIuaX
    Kidde Carbon Monoxide Alarm: amzn.to/3qtIIyP
    SolderWeld Flame Resistant Magnetic Blanket: amzn.to/3qtJ4Wb
    Malco 1/4 - 5/16 flip bit : amzn.to/3nr67yU
    Quick Check Acid Test: amzn.to/3GA2XAy
    Wiha Torqe Screwdriver : amzn.to/3u1swH6
    Wiha Torqe Screwdriver 1/4” adapter: amzn.to/3IH22Pw
    Compressor Tote: amzn.to/3H8xHst
    Inspection Mirror: amzn.to/3r9PERV
    Wiha TorqueVario-S 10-50 in/lb Torque Screwdriver : amzn.to/3GbKAku
    1/4” adapter for Wiha Torque Screwdriver : amzn.to/3u8g0pq

Комментарии • 86

  • @davidb2438
    @davidb2438 Год назад +23

    If cleaning doesn’t get you there, maybe overcharge or try measuring pressures with unit off, once unit is stabilized, see if pressures match ambient temperature, if high may be non-condensibles.

    • @OcRefrig
      @OcRefrig 11 месяцев назад +1

      Check Fan also - for Proper Direction & Placement in the Shroud. Blade should be 1/2 in & 1/2 out of the fan shroud. in the Middle of the Blade edge.

  • @phoenixhvac-r828
    @phoenixhvac-r828 Год назад +5

    90 degrees, hell we call that Spring time out here.😂

  • @dannysmith713
    @dannysmith713 Год назад +16

    I tell the younger techs clean looking condenser coil is "sneaky dirty"

    • @jamesfitzsimmons381
      @jamesfitzsimmons381 Год назад +4

      Danny S. I used to tell the younger guy to sneek up on all service calls as not to disturb a bundle of wires etc may a short in them and miss it rooting around too fast

  • @Ephesians-yn8ux
    @Ephesians-yn8ux 11 месяцев назад +2

    Showing up to a house that is 73 when it’s 93 outside should be a legitimate enough reason for a tech to smack the homeowner in the mouth.

  • @stephenbullock-yn3vh
    @stephenbullock-yn3vh Год назад +7

    Need to tell there lawn person to mow with discharge away from air conditioner. Excellent job Curtis 👍

  • @kens.3729
    @kens.3729 Год назад +4

    The Harder you Work, the Closer you Reach Retirement. 🤔👍🙏

  • @mikehouser5430
    @mikehouser5430 Год назад +5

    A good cleaning

  • @jerrybell6786
    @jerrybell6786 Год назад +1

    Thanks for keeping us cool Curtis

  • @jthonn
    @jthonn Год назад +11

    Those dang pine needles are a pain in the butt. I took both units apart at my sister in law's house a few years back and filled a big garbage can up with pine needles I pulled out of them. I sprayed the coils, well everything, with a degreaser and washed them out. When I put them back together they looked like new, and the performance increased so much she couldn't believe it. Nice work, stay cool! At least you didn't have to climb in the attic. Save those for early morning, yikes.

    • @tedhicks5431
      @tedhicks5431 Год назад +1

      Sometimes traps water and rust accumulator out at bottom and leak

  • @gmguy156
    @gmguy156 Год назад +4

    I just had a rooftop condenser In similar situation. Coil looked clean from outside. It was packed full with debris. Was located right next to the exhaust for when they run backup generator. Took a full gallon of cleaner to get it better

  • @kg4muc
    @kg4muc Год назад +6

    Great job as always! Be safe this weekend and don’t overdo
    Finally broke 70 here so I know it’s blistering down your way

    • @HVACGUY
      @HVACGUY  Год назад +8

      Where are you? Alaska?

    • @kg4muc
      @kg4muc Год назад +2

      @@HVACGUY you would think so but I’m in SW Virginia about 5 minutes from the NC state line and about as close to the Tn line. I’m in the mountains where it’s usually cooler but this year has been way cooler than previous years. Some crazy weather so far this year

    • @MsckMatt
      @MsckMatt Год назад +2

      @@kg4muc Im in ohio and its been crazy cool so far. We breached 80 maybe once or twice so far this year. Finally starting to warm up but damn we are going into july and the shop has been crazy slow, just pretty much yearly tune ups filling the schedule

    • @kg4muc
      @kg4muc Год назад +1

      @@MsckMatt Know what you mean it acts like we're still in early spring instead of into summer

  • @stevea6722
    @stevea6722 Год назад +8

    No rag with you? That's what pant legs are for! 😄

  • @thebluelunarmonkey
    @thebluelunarmonkey Год назад +3

    thanks for satisfying my OCD and finally taking the grill off. Pine needles are acidic btw, unless they are in ground contact in which microbes neutralize the acid. Which is why adding pine needles won't help acidify your soil.
    I'm not really OCD but another OCD is losing screws. You don't need a magnetic tray when you can use the magnet on your worklight.

    • @kevinshea4776
      @kevinshea4776 Год назад +2

      Ha...I said the same thing about the grill! But if you can save time here and there, but glad he saw too much build-up that resulted in a quality job by removing the grill. I'm surprised he didn't vacuum the dry stuff first and created soggy mud as a result! As a car detailer, you never want to spray liquid on a carpet without the vacuum process first! Fundamental rule! Great video and really helpful showing pressure decreasing from just some basic maintenance, resulting in better performance of the system.

  • @stevencossaboon3237
    @stevencossaboon3237 Год назад +2

    Nice work Curtis.

  • @mikedillon6233
    @mikedillon6233 Год назад +2

    Some other words, your outdoor coil is a super vacuum cleaner!

  • @danwittels5542
    @danwittels5542 Год назад +1

    Good job Curtis!

  • @michaelcinaz
    @michaelcinaz Год назад +3

    Good job of cleaning the condenser coil Curtis. 👍 you clean better than most HVAC technicians. I clean mine myself and I always start by propping up the fan and vacuuming out the leaves on the bottom with the shop vac while it’s dry. Then I give it a good spray down in and out. Would be better for the customer to not pile up the debris right next to the AC unit, put it in the trash instead.

  • @sergiohernandez4163
    @sergiohernandez4163 Год назад +1

    Friday was extremely hot in Kentucky . Im teling you no matter how much i stay hydrated i still cramped all day running service.

  • @tombeilman5579
    @tombeilman5579 Год назад +5

    I told my employees we need to work when we have the work and the weather let’s us. They just want to take off

  • @chris76-01
    @chris76-01 Год назад +4

    I work everyday too👍 my only day off is February 31st😅

  • @mariojackson6096
    @mariojackson6096 Год назад +2

    🤙🏽and you know thats right

  • @OnusBones
    @OnusBones Год назад +1

    A lot more thorough than I've often seen done; makes me rather wish you were in East TN.

  • @549BR
    @549BR Год назад +2

    Work all weekend; laugh all the way to the bank next week. 😎

  • @redline3036
    @redline3036 Год назад +1

    I'm working all weekend as well. This one was a dirty one holy cow.

  • @OcRefrig
    @OcRefrig 11 месяцев назад

    Good video ! You Might want to get Yourself some of those Orange Dishwashing Gloves 🧤 I got in The Supermarket if your going to be Lifting that debris out with your Bare Hands ! Ive found a lot of Black Widow Spiders 🕷️ & other critters in there when pulling Leaves & junk out of bottom of units. Be Careful, NorCal finds needles from Homeless in & around units. I Stopped using My hands to clean out units after some close calls.
    I Bought a 6 Gallon Rigid Shop Vac & it Makes Quick work of Cleaning out the bottom of Machines. Set the Vacuum on top of the unit & the Hose goes all the way to the bottom. Works Wonderful !
    One of the Best $40.00 I ever spent. Home Depot. Wet / dry Rigid shop vac. 5 or 6 gallon.
    A lot of Dead Mice around here in units , Black Widow spiders 🕷️. Id Prefer not to Handle that stuff.

  • @iamnoone.
    @iamnoone. Год назад +2

    My does the same thing in 90 plus weather the temp climbs 1 to 2 degrees because the unit is in direct sun from noon till about 4 in the afternoon once the sun gets off unit the house cools back down quickly. I thought for years there was something wrong, but the sun beating on the unit gets it so hot. It's a package unit

  • @jerrycunningham5608
    @jerrycunningham5608 Год назад +1

    Osprey down of aluminum clean and a good hosing off never hurts

  • @jayhatch7972
    @jayhatch7972 Месяц назад

    If you pull the return door off there is 3 screws behind it and that whole grill comes off. Just did 3 of these same units these week all dirty condenser coils causing the issue

  • @jackl9922
    @jackl9922 Год назад +1

    Great job. Enjoy holiday! My compressor is in a concrete area, gets no debris, but twice a year hose it out, get a lot of dirt. I guess because farmland only a mile or so away.

  • @bamatractor
    @bamatractor Год назад +2

    "Not keeping up" Ive heard that a few times this week!

  • @jamesfitzsimmons381
    @jamesfitzsimmons381 Год назад +5

    Fine workmanship. Looks like your pressure probes need new gaskets. Man that coil didn’t look that dirty from first pictures. Was thinking maybe overcharged b4 you cleaned it. Have been the doo -doo man on the 4th many times. Tell your boss to pay you extra lol. Be careful

  • @larryl2459
    @larryl2459 Год назад +2

    Don't cut grass or weed eat while your unit is running. I listened to the fan when you first walked up to the unit, it sounded like it was buffering the air instead of moving the air. Big difference in the sound after the cleaning. Enjoy your videos

  • @Brooks.Mechanical.Electric
    @Brooks.Mechanical.Electric Год назад +2

    Had a payne with 3.5 # overcharged this morning.

  • @pizzle1011
    @pizzle1011 Год назад

    I keep 2 of those expanding hoses on my truck! Life saver

  • @exmuslim1330
    @exmuslim1330 9 месяцев назад +1

    ///can you create a video, how to get the part number and the best websites to order parts for furnaces and how to order equivalent part if we can't find the original part?

  • @tphvac87
    @tphvac87 Год назад +1

    Curtis can you please automatically go to your settings and turn on closed caption, thank you! Love your video man, very educational and entertaining! That coil was nasty brother, I’ve had some like that and worse in my day, yikes!

  • @user-eh2ek6kk2m
    @user-eh2ek6kk2m Год назад +1

    Outstanding job as always brother. It's been a bit slower here in South FL compared to other yrs..

  • @kens.3729
    @kens.3729 Год назад +2

    Outdoor Unit looked Horrible. It’s Amazing what a Clean Coil will give you. 🤔👍

  • @Ted_E_Bear
    @Ted_E_Bear Год назад +2

    I love Miss Molly !

  • @HNIC86
    @HNIC86 Год назад +1

    Wow that unit definitely needed a maintenance for sure that head pressure was very high

  • @masterbeard367
    @masterbeard367 Год назад +1

    Cheers. Pulled in over $2k on Saturday and Sunday. Good job brother.

  • @Bryan-Hensley
    @Bryan-Hensley Год назад +2

    Well I haven't watched it yet but I was going to guess expansion valve bulb (head) lost pressure. But from the comments I'm probably wrong

  • @BWIL2515
    @BWIL2515 Год назад +1

    Ah the good old days coil after coil packed full of grass clippings

  • @masoncomeaux4105
    @masoncomeaux4105 Год назад +3

    I wish u were my dad!

  • @Garth2011
    @Garth2011 Год назад

    I like to fan out the stream from the end of the nozzle with my finger a little bit to get a more even pattern of water on those fins. Unfortunately, many residential plumbing hasn't got the best in water volume/pressure to do a really good job in a short time. Lots of trash down in the bottom of that unit too...its been years filling up.

  • @tedhicks5431
    @tedhicks5431 Год назад +1

    Boy I had one bout a week ago it was terrible couldn't see the fins

  • @jamesfitzsimmons381
    @jamesfitzsimmons381 Год назад

    Curtis look at the reply regarding 2nd look at the pressure/saturation temp. 30 minutes ago

  • @techfive7202
    @techfive7202 Год назад +2

    RIP probes lol.

  • @rday7573
    @rday7573 Год назад

    Unit is much quieter at the end than the beginning. Makes that motor/fan issue more obvious.

  • @jamierushing
    @jamierushing Год назад +1

    Hi bro from west Alabama

  • @anthonyelectric6045
    @anthonyelectric6045 Год назад +2

    Number one condenser issue. Dirty coils

  • @sousao3049
    @sousao3049 Год назад +1

    it's 105 in las Vegas.

  • @PhilipNation-xm5lh
    @PhilipNation-xm5lh Год назад +1

    I went on a local call recently where the customer attempted to self serve. High side on R22 was 475 and low was 50. The compressor kept hitting the high limit. The evaporator was clean and airflow good. Turns out, the "handyman" just kept shoving 458A (along with R22) into the system in an attempt to raise the low side. I pulled all refrigerant out and found 17 lbs of refrigerant in a system that was designed to hold 7 lbs. Hmmmmmmm.... Do it yourself and save money..... Not so much.

  • @GlenS123
    @GlenS123 Год назад +1

    Not going to say the condenser wasn't dirty because it was, but 30° over ambient is 435, you had 442. Don't know the SEER rating, lower rating at 20° over then it would have been high. Go to the next one, make some money!

  • @Sctronic209
    @Sctronic209 Год назад +4

    Your fieldpiece must be able to take a drenching. I always remove mine when washing condensers.

    • @jericosha2842
      @jericosha2842 Год назад

      I stopped caring about water on my probes. Haven't had a problem for 2 years lol

    • @brandoncorrea511
      @brandoncorrea511 Год назад

      @@jericosha2842lmao same I don’t got time

  • @larryl2459
    @larryl2459 Год назад

    My fan sounded the same, It's stopped up

  • @hillppari
    @hillppari Год назад +2

    That lawn is dead with all that water dripping from the AC.

  • @harrydickson4575
    @harrydickson4575 Год назад +2

    👍👍👍

  • @chrissmith513
    @chrissmith513 Год назад +2

    WoW that thing was sure dirty ! It's Canada Day tomorrow 🇨🇦🇨🇦🇨🇦 and have a good holiday on July 4 weekend ! 🇺🇸🇺🇸🇺🇸

    • @HVACGUY
      @HVACGUY  Год назад +2

      Happy Canada Day

    • @wilburncon7789
      @wilburncon7789 Год назад

      Ain't nothing to be happy about in communist Canada

  • @johnbreland4099
    @johnbreland4099 Год назад

    Magnetic tray helps with the screws 👍🏼

  • @rday7573
    @rday7573 Год назад

    What tool bag is that? I dont see it named in the description.

  • @karellodewijks4971
    @karellodewijks4971 Год назад +2

    👍👍😊😊

  • @larryl2459
    @larryl2459 Год назад

    After I cleaned mine my electric bill dropped $ 30

  • @JohnSmith-ug5ci
    @JohnSmith-ug5ci Год назад +2

    Telling her it could freeze if turned to low is false if the unit is working properly. If it is not working properly then it needs repaired. It looks like you got it patched, but it needs some more work.

    • @jamesfitzsimmons381
      @jamesfitzsimmons381 Год назад +1

      Looked pretty thorough to me. Sure he didn’t put his temp probes on the lines. Maybe the owner should request a maintenance inspection where he can check/ clean the evaporator check wiring , capacitors Just my opinion sir. I do believe to can cause a frosting/ freezing condition if the lack of load and ambient temperature is too low. Just my opinion I do value your experience also

  • @mikehouser5430
    @mikehouser5430 Год назад +3

    1st

  • @robertwojtowicz933
    @robertwojtowicz933 Год назад +2

    What was the head pressure before you started? I couldn’t see it.

    • @HVACGUY
      @HVACGUY  Год назад +1

      450

    • @jamesfitzsimmons381
      @jamesfitzsimmons381 Год назад +2

      @@HVACGUY
      Curtis I was looking again at pictures of the pressures. Something not correct. Pressures and saturation liquid temps don’t agree. I know you don’t show LL temperatures etc. I think you have in refrigant charge If so your final LL sat temp over your ambient temp your said is still very high. Maybe overcharging for starters. Let me know if you see in the video 😊