Solar Inverter Self Power Consumption Solution |Why ziewnic4.5kw inverter consume 1.7A Without Load
HTML-код
- Опубликовано: 20 окт 2024
- Boohat say New solar installer nay ye complaint ki the k hibird solar inverter load k bagheer cleamp meter pay ampair show karta hay .
us problem k hal k leye ye video bani hy.Why ziewnic4.5kw inverter consume 1.7A Without Load
See All A2Z Solar Videos Link
/ @a2zsolar
Why hybrid inverter consume 1.7A Without Load | Solar Inverter Self Power Consumption Solution
Contact us:
Solar project installation - Sponsors your Products - Training/Awareness Session - Start Solar Business
Email : a2zsolar.pk@gmail.com
Whatsapp : +923073898989
Phone: 047 7500 292
Website :
Mudassar Rahman A2Z Solar Jhang Punjab Pakistan
#inverter #ziewnic4.5kw #ziewnic
My other useful videos links:
Best Solar Ac Video Link
• Solar Ac Price in Paki...
Solar Tubwell System
• solar tube well 15 hp ...
Inverter Setting & Programming
• Solar Inverter Setting...
Best Solar Panels in Pakistan
• UnBoxing Risen Solar P...
NET meting System
• Net Metering in Pakist...
Thanks for Watching
Make sure to subscribe my channel and press that bell icon for latest notifications so never miss any video.
__/Contact Us\__
►Instagram:➜ / a2zsolar
► Facebook Page:➜ www.facebook.c...
► Twitter:➜ / moudassar3232
► TikTok - A2Z SOLAR
► Email : a2zsolar.pk@gmail.com
► Whatsapp : +923073898989
► Phone: 047 7500 292
► Website :
excellent
Kya ap bata sakte yhe reverse light q on horizontal hye
Boht dino se me ye search kr rha tha. Shukriya janab
SBU setting change krne k bad ap power Utility se to nai le rhe but ab wo Battery se stand by mode k liye jo power chaiye hoti he wo le rha he nd ap same experiment clamp meter pe Battery k DC wires k 7 connect kr k b dikha de.
G bilkul aisy to battery ki charging he full nai hoge
Exactly
hn g rat ko battrey consume ho ge. ya koi proper solution ni h.
light b na ho or dhoop b..or battrey charging sari inverter pehla he consume kar chuka ho.
@@malikfaisalwaqas5269 sir sari battry khrch ni hoti setting mn option h k ap kitni bettry hone pr wo shift hony mslan ap 75%pr rkhen taky 75%ap k ps after bijli raat k time ap k ps rhy
Great Video Mudassar bhai
Bohat aalaaa.bohat informative.👌👌
Brother if you want to check or calculate the self consumption of any hybrid inverter just connect your battery with your inverter and then just calculate the DC amps your inverter is drawing from your battery. Don't connect Wapda or PV only connect your battery.
زبردست بہت خوب جزاک اللہ خیرا
aoa sir jab load off ho aor phir bhi 700 watts wapda pe load kis cheez ka hai.? raat k time men ghar ka saara load off kr den phir bhi wapda meter pe 600-700 watts ka load hota hai..ya phir baarish k time men aisa hota hai. aor apki is video men bhi without load 700 watts wapda pe consume ho rahay hain. plz reply
MashALLAH good video
super out class video 👍
So very impressive sir ❤️❤️❤️❤️
Mashallah Great video
Great excellent work
Thanks
Sbu wala formula tab tak kaam krta hai jab tak battery minimum discharge volt se oper ho.. Jesay agar app ne 46 set kiya hai k battery load ko chor day jab 46 par aye to jesay hi 46 ho gi to sara load better se wapda pr shift ho jay ga.... Or inverter 1 amp yani 200w k qareeb wapda se bijli lay ga. Is liye ye formula fail ho jata hai...
Raat ko 12 ghantay bina load k b 2 se 3 units leta hai inverter or load k alag.
Isliye ye bhut bara masla hai is k bagahir subah jo bachat hoti hai wo raat mien extra units ki waja se zaya ho jati hai or solar ka sai faida nai hota.
Same issue
اس کا ایک حل ہے۔۔۔
As usual very detailed and informative video, very good job please keep it up one day hope to meet you in person.
Exactly 💯 right mera maxpower pv 7000 aesa hie hai
AOA. BHAI YEH INVERTER
HIGH /LOW LOAD CONNECTION K OPTION HAI KIA .
MASLAN LOW PAAY FANS LIGHT AUR HIGH MAIN PUMP AC WAGHAIRA CHALTAY HON .
AGAR WAPDA BAND HO JAYE TU AUTO HIGH LOAD OUT BAND HO JAYE AUR LOW OUT CHALTA RAHAY.
Bhaii wapda input ki neutral wire ko inverter ki output neutral se connect kar do
Phir yeh 0.0 amp b nai le ga
Lekin us k liay shart yeh hai k aagy wiring MN kahin pe neutral break nai honi chaahiay
orr agar break ho tu?
Very very Good video bro ❤️🔥👍✅
Modaser bhai mere pass 330 wahtts k 14 penals hy our pani ka level 100 foot hy moje 2 inch delori kele konsa samrcebal pump lagana chahe
SUB setting par aap me wapda meter ki reading nahi dekhai ??
Sir mera pass sofar 6kw ka hybrid inverter hai 2mppt hai solar pannel bahut dur hai (115mtr) single pear waire hai 2 mppt parallel kr sakte hai
(2 string parallel in 2mppt inverter parallel)
Assalam o Alaikum clamp meter sy Dc ampere negative wire py check kry ya positive py check hoty hy dono wire m readings different show ho rhi hy ap tareka batae
without battery wali b setting bta den bhai
Growatt 10kw ongrid ka bhi check kr k btaen kindly k kitni bijli leta ❤
1.5 A leta hy grid sharing option py despite sufficient wapda reason?
ap ne konsa inverter ki self consumption km kr di. wapda se load bs battery pe shift krdiya 😂
i think so
Brother battery pe to load shift hogya lekin agar battery Kam hogi to solar se charge b Hoti rahy gi or is Tarah aapki battery k floating voltage b pooray rhn ge to faida to hua na
K nai?
BHI Jaan reply zroor krna ziewnic 1.5 lgwaya h 5 din sy battery charging hi KR Ra h 1 cell first wala ye hi show KR Ra h k charging ye zroor btay ap
Good job 👏
Assalam alaikum sir kia hall hy ap sy eq swal hy ho sky to video bna kr bta dy kia soler panels ko horizantal or virtcul lagany sy efficiency mey koi farq ata hy jawb zaror dena
Naii pyaary bhaii asa koi seen nai hai solar plates ko sirf latitude or direction k mutabiq lagana chahiay bas
As salam o Alaikum sir mera 1 question hai
mere ghar ka uses 300 se 500w chal raha tha SBU mode per or PV production mere pas 600 se 700 show kar raha tha,
jese hi mane electric geaser on kiya mera wat 2200 tak pohanch gaye to foran se inverter ne battery sharing start kar di kyun k PV 600 se 700 energy produce kar raha tha to baqi ka load inverter ne battery se utha liya lekin chand seconds k bad mane jab dekha to PV 2500w tak energy dene lag gya halan k pehlay PV max 700 se uper jata hi nahin tha lekin jese hi mane 2000+ watt load dala to PV bhi zyada energy banana start ho gya.
kya aap bata sakty hen k PV energy kis principle k accroding humary ghar ko di jati hai.
kya load zyada ho to inverter pv se zyada load utha leta?
or agr ghar ka load kam ho to inverter pv se thori thori energy uthata rehta?
explained plz...
Mere bhai Meri baat sunain
Aapka inverter bilkul theek hai
Solar plates hmesha apni efficiency k mutabiq voltage deti hn
Current tab draw hota hai jab un pe load dala jaay
To jab load Kam hota hai to hmrara load solar plates se Kam current draw karwata hai jab zyada ho to zyada
To is Tarah aap current or voltage ko multiply krn ge to aap k pass power aajay gi
Simple
Nice info bro
Bhai jb sbu kr do gay to wo battery say consume krny lg jayga to bat to aik hi hai
Sbu krny say 2nd priority wapda say wo battery pay convert ho gaya to agar soller power rat ko down ho ga to wo 2nd priority wapda ki bajay battery say load pora karyga then kya yeh sahi hai 🤔
Ham kaiss tarke se solar touwal ki satring ma sa conacshion nekal kar is invartar ko karant de ziewnic 4kw invartar ko jis tarah ap unique tarke sa vfd ka sath ap invartar lagtay ha is par makmal 1 video bana de please mojhe is ki boht zarorat ha
Good brother
Sir inverter khud kitne bijli lyta ha yh kaha likha hota ha,?
Janab Aik to aap ny sub sitting pr check nhi Kya dosra apny bataya k ye 7 watt ly Raha hai to pr clamp meter mein 0.6 Ampare q show kr Raha .
Kia mppt b electricity consum krta hai
Sir "dekhne ko milta hy" zra kam bola karein, ap waha bhi ye bol jaye hain jhan is ki koi zaroorat nahi. thanks
Sir reverse ki light kyun on theee???
Kyu
آپ نے چھ یا سات واٹ کے بعد زیرہ لگانی ہے ۔اس طرح یہ ساٹھ یا ستر واٹ بنتے ہیں
Ya AC current hotaa h yaa DC?
Bhai battery SE kitne amp consume karta hai yeh b bta dete
السلام علیکم بھائی ایک پریشن ایس یو پی ایس کا بھی کریں homage bolt series 3216 -oso🔋 setting Zero load standby 300 watt wapda metre 📟👈review consume
Good Ustad G
سر اس پر 150W والے پینل بھی لگا سکتے ہیں
Ye inverex inverter ma b ha masla battery full b ho TB b ampere zyada khaata ha actual load sa tbhi bijli ka bill zyada aata ha
Sir peghle wali setting or change settings mei faraq kia tha
Sir yhe reverse light matter per on q ho Rohi hye
Mare wapda matter per yhe on rha to some time some time off ho jati hye please explain
Mery solarmax pv4000+ per bhi yehi masla a raha hai. Mein bagher bettery k chala raha hun. SUB setting per kabhi kabhi reverse ki light meter per on ho jati hai. Or agar sbu per chalaon to load dalny per inverter trip ho jata hai or leave ghar ka load band ho jata hai. Agar apko solution mila hai to bta den please?
Bhaii aap wapda ki input neutral or inverter ki output neutral ko common kar ln masla Hal ho jaayga
Lekin us k liay shart yeh hai k neutral aaggy wiring MN kahin se break na ho
but you do not tell if bettries not installed and also please tell about wapda sharing for load lower than PV installed capacity.
Sir agr Multan MN. Ghr py Soler setup lagwana ho tu ap Laga daty hn
yes03073898989
sawal to ye he. inverter phir show q krta h zyda amp. plz ans
Bro ap nyn without battery jo 0.8 amp sa 1.7 amp tk extra load ata hy wo khtm krna ka treqa nh btya
Inverter kb utility sai battery ko charge krta hai to energy meter mai earth light on hojata hai. Esko kasa hatm karu?
Bhai zewnic k is model.k dongle feature per video bnaye
Bahi jan mare pass ziewnic Z5 pv8500 lag ha wo 6A le ha
Same here... Any solution please btana??
ap ky meter py revrce light kyu on hy.....
Sir without battery 2amp lata ha
O bhai battery sy ly raha hy wo Because os SBU. Ap battery hata do to wapda sy hi ly ga aprox 250w
AP K METER PAAY REVERSE LIGHT KYUN CHAL RAHI HAI ...ISAY KAISAY CLEAR KARNA HAI .
Ye inverter 3.6kw sy upar load ni uthata overload ho k band ho jata h
baki sab baat to theek hy 2sra hall kia hy???
My NY AJ brekar lgwaya hy rat ko inverter wesy he bnd kr deta hn
Sir mara pass 1.5 kva frouns ka Inverter laga howa ha... Wo bi stand bay mode main 1.20amp layta ha...
Jazakallak.... Tu sir satting main ja Kar SUB ki satting okay ka do...
Fitting proper hogi to shelf consumption 0 point pr ho jae gi
Battery k elawa konsa setting karni hy k comsumption kam ho jae, hamara frounus hy wo 2.5A laita hy means Approx 550 watt consumption hy without Load
Jawab mila bhai mughy bhi btai please
Bhai yeh reverse light kiun on hai mere pass bhi yahi issue aa raha hai, kindly reply
Same issue, koi hal mila?
Aslam o Aliekum sir mujhe 1.5 ton AC chlana ha mujhe 2.5 kw inverter lena chahiye ya 3 kw ?
3.6kw ka least
میں سیالکوٹ سے ہوں میں سولر سسٹم کورس کرنا چاہتا ہوں
7:32 per 113 watt to solar say bhi arahay hai us ko bhi to count kry na
اسلام علیکم بھائی یہ سیٹنگ جس میں سولر پھر بیٹری پھر واپڈا کی جب پہلی سیٹنگ کرتے ہیں تو واپڈا سے بیٹری چارج نہیں ہوتی اس کی سیٹنگ بتائیں
V Nyc🌷🌷
Bhai ap mujy reply q nhen dety .... Please meri help kr den ....
Sar 4.5kw ki satinges over all ki video up lod kare
Sir ye inverter mai nay apnay ghar pe install kia per ye output 3.5kw deraha hai aor phir 07code Matlab ye 4.5kw nahi hai
Tall tubular batteries pe 3500w hai, lithium batteries pe ye 4000w tk chala jata hai
Night me jb solar nae hota to tb invertor wapda use kerta ha zero load pe
Reverse light on kyu hai plz batain
Assalam alaikum bhai solar system sa mutalik WhatsApp group ha bhai link snd kara mujaa
Is inverter ki PV testing kren pls.
Bhai is inverter ka load check karwa Dy plz koi video nahi hai iski load k sat
Mere q 400w wapda se share krta? Output do ya na do
Bhai aap energy meter ki 5 number reading check krn us pe nai le rha hoga 400 watt
Jo hum note krty hn wo reactive power show ho rhi Hoti hai jab k energy meter sirf active power to count krta hai
Usi per de rha hai, UPS mode per 200-250w meter ki 5 no location per leta hai aur APL mode per reverse light on ho jati aur us per phir reverse current jata hai 150-200w aur grid feeding off hai @@Islamsforall
reverse light kyun chal rahi ha brother??
Is ka Ans mughe Bhi nhi batya gya
ISKA USER MAUNAL UPLOAD KARAIN. 4.5 KW GOLD SERIES KA
Brother meter reverse light keo on kar rha
Jub ap ko khi se Ans mal jye to mughe Bhe batna
@@drshehzad7294 solar sestem laga apka?
Kyon k neutral wapda aur solar ka common he.
Sir market mein koi aisa vfd ha jo wapda se live sharing kr skta ho??
Jntech.
Imported by fouz international
Ok
Sar aapko ek manth ho Gaya lekin abhi tak aapane video load testing Nahin banai sar iski jaldi video upload kar de please
First comment
I Love you.
Mujhy next video men apky peyar bhary comments ka wait rahy ga.
Sir ap mughe reverse light ka nhi batya yhe q on hoti hye
Some time on hoti hye evening me off ho jati hye wapda matter per ap k pass is video me reverse light on hye asa q hota hye please replay
Is setting say ap inverter ki power ko tu rook ly gy lakn battery ka back up bilkul be nai rhy ga is say
Is setting say ap ki first priority soler second battery third wapada ho gi tu battery ka beckup nai rhy ga
Solar se power pura ata he, per b Wapda meter se 4, 5 ampare leta he. Tesla HLE 6kw. Wapda bnd b kre, per b solar se power pure hute he
Same sir please reply koi msla hal hoa?
SUB setting me Wapda se 5 se 6 amp load use ho Raha he battery charging b off he 16 number me OSO b ki Phir b ye issue samajh me ni araha plz guide me ghar ka Sara load off he Phir b 5 se 6 amp kaha ja rahe he
Ap ka solar wapda k sath by pass ho gia hy software dobara krwain ya wapda off krdia krain inverter ka
@@MuhammadArshad-wy3em
Software update kaha se karway or software update karwane se koi problem to ni hoti?
Brother aapny energy meter ki reading Dekhi hai 5 number?
Us pe nai le rha hoga
Yeh Jo power show krta hai yeh reactive Hoti hai
Jabky energy meter sirf active power ko note krta hai
Bhai cnfrm software ka issue h?@@MuhammadArshad-wy3em
آپ نے بغیر بیٹری کے کیسے کریں گے؟
آپ نے کہا بعد میں بتائوں گا مگر نہیں بتایا
سر کوئی ایسا طریقہ بتائیں کہ انورٹر رات کو بند ہو جائے رات کو ہم ڈائریکٹ واپڈا استعمال کریں انورٹر کے بغیر تاکہ رات کو 1.7 ایمپیر خرچ ہونے سے بچے رہیں یہ کیسے ہو گا
Change over lgaye Bhai , rat KO change over nichey krne se inverter bnd ho JY Ga Apka
Battey k bghr hyrid systems flap hn
3،6kw se ziyada load uthata nai hai 4،5kw nai hai janab
Is me hal kahan ha
Bhai merey wala tu 3amp leta he
Mujy solar system ka course krna hy online urdu men .....
y jab batrry chage krty tab lyty bohat ziadda waat
Sar video upload karne please
Bagair battery k apne dekhaya hi ni