MC Protocol or Melsec communication protocol. It is a serial communication protocol that uses a binary format to transfer data. MC Protocol can be used with various communication interfaces such as RS-232C, RS-422, RS-485, Ethernet, and USB.
If you are working with older Mitsubishi PLC models like the FX or Q series, GX Works2 is necessary. However, for the latest iQ-R and iQ-F series, GX Works3 provides a more advanced and efficient programming environment. Therefore, while there is some functional overlap, GX Works3 cannot fully replace GX Works2 if you need to support the older PLC models.
The wiring and configuration of FX2N and FX3S PLCs are generally similar because they are both part of the Mitsubishi Electric FX Series PLCs. However, there can be some differences depending on the specific models and their features. It's essential to refer to the user manuals and documentation provided by Mitsubishi Electric for each PLC model to ensure that you wire and configure them correctly for your specific application. Keep in mind that the wiring and configuration details may vary, so always consult the appropriate documentation for the precise information you need. Always check Data sheet or User manual dl.mitsubishielectric.com/dl/fa/document/manual/plc_fx/jy992d55301/jy992d55301h.pdf
Hi, i'll be happy with small answer - is it have different how to plug electricity? Where should be line and where neutral. Can i just connect line or in any case I should find line and neutral.
If the power indicator light is not turning on, it may indicate that the PLC is not receiving power or that there is an issue with the power supply or wiring.
Uploading the PLC program should be done in "Run" mode rather than "Stop" mode. The main reason for this is that the PLC operates differently in these two modes, and uploading in "Run" mode ensures that the program being uploaded is the currently executing and active one.
@@TheMachine0021 The reason I asked is because I downloaded a FX2N-128MR program to my PC in STOP mode and uploaded the saved program to another PLC of the same type in STOP mode too and it didn't work. Could this be the reason that uploading should be done in RUN mode? Thank you for your help.
This was the greatest video in history
This is revolutionary work dude
I watch your channel from the first videos
Thank you sir very helpful to me as beginner
very clear, good video. Thanks
this got me soo hyped
Explicação fantástica
Me ajudou e muito
Muito obrigado mesmo like
Good presentation thanks
Bring more videos like this!
hi,
I have the cable that connects to the ihm, could it be used with an adapter to program the clp?
thanks man. its helps alot
Great, magical!
Good video 👍👍
Interesting! What will be next?
Can i pull the problem from one plc and program another plc with it?
sir..which communication protocol you are used in this plc
MC Protocol or Melsec communication protocol. It is a serial communication protocol that uses a binary format to transfer data. MC Protocol can be used with various communication interfaces such as RS-232C, RS-422, RS-485, Ethernet, and USB.
will the gx works 3 also work?
If you are working with older Mitsubishi PLC models like the FX or Q series, GX Works2 is necessary. However, for the latest iQ-R and iQ-F series, GX Works3 provides a more advanced and efficient programming environment. Therefore, while there is some functional overlap, GX Works3 cannot fully replace GX Works2 if you need to support the older PLC models.
Sir good day. I would like to inquire if this unit is the same of Mitsubishi FXos- 30MR- ES is the same wiring diagram to be apply?
The wiring and configuration of FX2N and FX3S PLCs are generally similar because they are both part of the Mitsubishi Electric FX Series PLCs. However, there can be some differences depending on the specific models and their features. It's essential to refer to the user manuals and documentation provided by Mitsubishi Electric for each PLC model to ensure that you wire and configure them correctly for your specific application. Keep in mind that the wiring and configuration details may vary, so always consult the appropriate documentation for the precise information you need.
Always check Data sheet or User manual
dl.mitsubishielectric.com/dl/fa/document/manual/plc_fx/jy992d55301/jy992d55301h.pdf
Thank you sir .
Interesting sir❤
Such sublime :)
Hi, i'll be happy with small answer - is it have different how to plug electricity? Where should be line and where neutral. Can i just connect line or in any case I should find line and neutral.
Hello Sir, In power terminal you can find it there a line and neutral terminal. Labelled as L and N.
Sir prog e indicator blink,
How to recall program when battrydischsrge inVOYAGER 3 Lamination machine
What mean if run light is not on?
If the power indicator light is not turning on, it may indicate that the PLC is not receiving power or that there is an issue with the power supply or wiring.
i need plc programming software for mitubishi
What happens to the program if I download the program in stop mode and not in run mode?
Uploading the PLC program should be done in "Run" mode rather than "Stop" mode. The main reason for this is that the PLC operates differently in these two modes, and uploading in "Run" mode ensures that the program being uploaded is the currently executing and active one.
@@TheMachine0021 The reason I asked is because I downloaded a FX2N-128MR program to my PC in STOP mode and uploaded the saved program to another PLC of the same type in STOP mode too and it didn't work. Could this be the reason that uploading should be done in RUN mode? Thank you for your help.
Probably, uploaded it in run mode.
you will receive an error during uploading.
Can i use sc09 cable for fx2n plc
Yes you can via rs232 port on ur laptop or pc if you dont have rs232 buy another adaptor rs232 to usb.
❤Sir interesting