Siemens S7-1200/1500 HSC counter/encoder data retention after CPU shutdown.

Поделиться
HTML-код
  • Опубликовано: 1 янв 2025

Комментарии • 20

  • @dennisrubio2375
    @dennisrubio2375 9 месяцев назад +3

    We miss you Sr 🎉😢

  • @ΚυριάκοςΚλέττας

    You are so kind and thank you so much for this video!!!

  • @mhplraj
    @mhplraj 9 месяцев назад

    Excellent video, simple and easy to follow

    • @IGSElectronics
      @IGSElectronics  9 месяцев назад +1

      Glad it was helpful!

    • @ahmedbouabid8279
      @ahmedbouabid8279 7 месяцев назад

      Can i Ask you i have a problème in automat s7 1500 the électricité cut and back now the plc dosnt star automatic i must start CPU manualy

    • @ahmedbouabid8279
      @ahmedbouabid8279 7 месяцев назад

      ​@@IGSElectronicspls Can you help me

  • @erengultekin3459
    @erengultekin3459 8 месяцев назад

    Thanks, that helped a lot!

  • @aldor159
    @aldor159 Год назад

    Very good explanation! Thanks, it was very helpful.

  • @shrenikgariya2568
    @shrenikgariya2568 Год назад

    Thanks for sharing this video Thank You so much dear

  • @Kristjan10a
    @Kristjan10a Месяц назад

    i had similar problem when i used a omron plc. The süstem that pushes material had to be reset every time something went wrong or power got cut. The system always forgot the position and had to be zeroed using end stop sensors. It had length data so it new where to stop after zero position. The company did not whant to upgrade to new systeb because the mashine was old and thay wanted to sell it so i had to make manuals haw to use it because it had no documentation and no diagramas. A real pain in the bumm to connect anything because wires got cut when thay dissasembled it in the last location. Got it working in a few days but still i fiil like it was not worth the time and effort because now the mashine just sits and dose nothing. For simpler mashines i upgraded to LOGO! and it works fine because logo retains values even after power off.

  • @jatojawiecjakojachce
    @jatojawiecjakojachce Год назад

    Good job

  • @pangingreece83
    @pangingreece83 Год назад

    Thank you so much 😊

  • @redlines2535
    @redlines2535 6 месяцев назад

    Really interesante

  • @learnplc304
    @learnplc304 8 месяцев назад

    Hello Sir, thanks for this informative video. Please tell how we can reset this retentive value like our button in HMI(Set Zero Position). Please help i am stucked into this.

  • @rpbhatt8646
    @rpbhatt8646 Год назад

    Very informative video, please teach me how to reset counter, its not resetting, please

  • @machineryoverhaulretrofitm6607
    @machineryoverhaulretrofitm6607 11 месяцев назад

    Dear experts
    is the HMI Connection Box Compact 6AV2125-2AE03-0AX0 compatible with KTP900 MOBILE 6AV2 125-2JB03-0AX0
    simply i want to use it as Ethernet switch
    i could not find any reference
    please help me before ordering
    thanks
    Zach

  • @leonardo-g9o
    @leonardo-g9o Год назад

    Hi sir can you make a video of S7 300 high speed counter

  • @rameshsingh-ly1js
    @rameshsingh-ly1js 4 месяца назад

    Thanku

  • @kondito88
    @kondito88 7 месяцев назад

    thx:)

  • @rameshsingh-ly1js
    @rameshsingh-ly1js 4 месяца назад

    How to reset this