Nice explanation sir, please make video on MVR(Mechanical vapour recompression), LTE (low temperature evaporator). It is new technology by @SEDL and is commonly used by many industries nowadays and this system does not requires any external source of heat and replaces the ETP and MEE plant
Sir ji...... single element drum level control and three elements drum level control ke bare main ek video bana dijiye please please Uske sath FRS ( feed regulator system) kya hota hain?
sir PHE charging acw aur ccw ka safe normalization aur safe isolation kaise kare, aur phe change over processes ke bare me bataye for safe changeover from PHE-A to PHE-B without effecting pressure. ccw aur acw me pehele kisse charge karte hi aur kyun ? phe ko back charge karte hi ya sidhe chagre karte hi, aur sir PHE CHANGE OVER KE lie kya karan hi jisse ye decide kare ki PHE KA chage over kar lena chaiye. delta t dekhe ya delta p. sir kisi plant me PHE vent nai dia jata hi usme PHE normalise kaise kare drain karne ke baad, usme se air kaise remove kare properly jaha kewal phe inlet aur outlet drain dia hota hi sir alag alag log apna kahani sunata hi, pls aap video bana ke standard procedure bataye. me interview me reject ho chuka hu operater ka. please sir, thanks in advance.
Sir water plant me softener charge karne ke liye kitna NACL chaiye aur DM plnat me regeneration ke liye kitna chemical chaiye ye kaise calculation karenge
Very Good Explanation 👍 it's too nicely understandable for entry level production employ💯
Nice explanation sir, please make video on MVR(Mechanical vapour recompression), LTE (low temperature evaporator). It is new technology by @SEDL and is commonly used by many industries nowadays and this system does not requires any external source of heat and replaces the ETP and MEE plant
Very informative video. Thank you sir ji
Excellent explanation
बहोत बढिया जानकारी
Bahut achhe se samjhaya aapne
Ur explanation method is very good brother keep it up..God bless you...
Thank you for important information
hello bhi
good explained good
Sir apne pressure 3rd evaporator ka jyada likha hai , jo ki kam hona chahiye??
Good informations sir
Kindly ZLD plant video upload kariye....
Sir ji...... single element drum level control and three elements drum level control ke bare main ek video bana dijiye please please
Uske sath FRS ( feed regulator system) kya hota hain?
Sure dear I'll make
sir PHE charging acw aur ccw ka safe normalization aur safe isolation kaise kare, aur phe change over processes ke bare me bataye for safe changeover from PHE-A to PHE-B without effecting pressure. ccw aur acw me pehele kisse charge karte hi aur kyun ? phe ko back charge karte hi ya sidhe chagre karte hi, aur sir PHE CHANGE OVER KE lie kya karan hi jisse ye decide kare ki PHE KA chage over kar lena chaiye. delta t dekhe ya delta p.
sir kisi plant me PHE vent nai dia jata hi usme PHE normalise kaise kare drain karne ke baad, usme se air kaise remove kare properly jaha kewal phe inlet aur outlet drain dia hota hi
sir alag alag log apna kahani sunata hi, pls aap video bana ke standard procedure bataye. me interview me reject ho chuka hu operater ka. please sir, thanks in advance.
Sure dear I'll make
Information important thanks
Thanks sir keep it up and keep doing great work for us head off sir
Excellent
Bro also explain about ATFD (Agitated thin film dryer) please
Very soon I'll upload
Nice
Very nice explain
Hard wark very nice 👍👍👍👍👍 sir
Sir, I have joined a company in similar field , can you help me how to design a plant of MEE with example ?
Sir MEE operator ,ka future growth kaisa h agar ise sikha jaaay or life ko isi me future banana soche ?
Neend to know about ....MVRE operation
Sir...
Recently I have seen an EVAPORATOR PLANT...
It has the capacity 330tph...
So.. Sir Could you explain
How to calculate its capacity
Sir
Which is the better flow rate and steam pressure for MEE
Thanks bro
Sir. CIP kese karte hai? Aur vecume ke bare me thora samjaye
First thank you sir.
Feed water parameters kya rhege like pH, TDS ..
Ph ko hum 5.0 -6.0 tak rakhege or iska tds minimum 25000 to hona hi chahiye
Sir MDP dyar k bare m batye kuch
Bhai MVRE plant pe ek video bnao na 🙏
Sir condensate valve open rakhege to water bahar nikal jayega na???
Nice information
Bhai sahab agar tube me steam provide karaoge to chocking ho jayegi tube me
Steam hamesha shell side me provide karate hai
excellent topic
Nice explain sir
Next MVR plant pe ek video bna digiye🙏🙏
Hello
Tumhe
Mujhse phone karo tum main batata Hua. MVR plant ke bare me
Thank u so much sir!
Sir kya mee me TSS or hardness matter karta hai Kya?
Agar karta hai to kitna maximum TSS or hardness rehna chahiye feed me plz reply
Sir please MVR par b banaiy detail video
Sir water plant me softener charge karne ke liye kitna NACL chaiye aur DM plnat me regeneration ke liye kitna chemical chaiye ye kaise calculation karenge
Sure dear I'll make
Mee ke all calculations pe video bana dijey. Sir please please please
E2 ka feed kya hota hai?(Is it vapour from E1)
Or Another feed ?
Excellent sir.....
Thanks dear
Nice 👍
Sir please make a video on condense Polishing unit
Sure dear very soon I'll upload please wait for the video
Sir mollaasis based ethenol plant pe video बनाओ plz
Nice explain anna
❤
Sir steam tube m rahega ya shell m?
Please make a video for crystallizer
Sure I'll make
Sir please atfd n stripper solvent par video banaye
Very soon dear I'll upload please wait for the video
Sir, condensate recovery kitne feed se kitna condensate milta hai and kitna salt milega. Please calculations bataye.
Nice explained
Sir, ATFD feed lph se kg me convert karne ka formula bataye .
suggestion - you could have made the video half length had you avoided using same words repeatedly.
How to calculate salt rejection and steam economy sir
Dear sir
Please ap loaded video for MEE plant CIP process
Simple , cleaning by high ph (caustic) and low ph nitric acid
Sure dear I'll make
Kya ho agar vacuum pump ka connection heat exchanger me na dekar condensor tank me de, kindly reply
Great explanation 👌👍
Super sir
Thanks dear
sir gressline kitne ghante bad nikalte hii aap
Mee Plant circulation process and diagram of circulation of process pls make video sir
sir ji TSS kaise kam kare uska video banao plz
Shabas
Sir, I have doubt that you have taken 600mmHg pressure is higher than 450mmHg but pressure in third should be less than second and first Evaporators
TVR ka aap ek video banana
sirji let me know i have 1 Tonn Boiler so Running cost of MEE for 50 KL daily neutral water
make video on forced circulation evaporator
Video is already uploaded
Excellent explanation 😍
Make video MVR plant
Mee plant kitne prakar ki hoti hai ek to best Mee or dusri kon si hoti hai????????????? Ans batao
Tq sir ❤️❤️❤️
Pls tell me sir
Dosing ppm formula
LPH
%
With chemical flow & concentrate
Sure I'll upload
Mee system efficiency and atfd efficiency kaise nikale sir plz formula batay..🙏
कोष्टिक रिकवरी प्लांट यानी सीआरपी के बारे में हिंदी में बताने की कृपा
Hello, Are you mixing the steam with raw infeed??? i have doubt here??
There is no direct contact of feed and steam, Only heat transfer occur
Sir please create TSP chemical reaction in boiler
Sure dear very soon I'll make
Sir I want CRP caustic recovery evaporator plant video . Nazer talukder ctg Bangladesh.
Sir VLS ka temperature nhi badh Raha h kya kre
I an RO and MEE operator
Colendria ka Jo level liya jata hai wah kitna unit hota hai
Sir Mee plant ko kisne create kiya hai
Ek plant ke bare me samjha ye sir Ji please kuchh samjha me nahi aa raha hai
Please help me
Why single effect evaporator used 0.5kg steam while applying 1kg?????
Sir MVR ka video dalo
TDS of feed water of mee plants ??
Sir Does entrainment effect can affect this?
Sir evaporation mai vacuum drop ho gaya to kya kare?? aur plant chalu karte samay vacuum trial kaise lai??
Check Hydro Test of MEE plant or check vacuum pump ..
Lebal kitna liya jayega sir ji
sir shekhana hii plant
Bro faling film steam and feed calculation plz explain
Company ka naam hai s c i limited raypura rajoun banka
Is it possible to run MEE on electricity
castic ad krne se kya effect hota hai
pH booster ka kam krta h
Tube me liquid hota hai aur shell side me steam rahta hai
Fall film evaporation ?
Very soon I'll upload please wait for the video
sir coaching mill shake hii
Feed aur steam mai garbar hai
Me plant me new joining kiye hai
Please sir help me
Vaccum values are in wrong sequence. It should be 600 mmHg in E1 and 450mmhg in E2 and 300mmhg in E3. Please cross check
Yes , you are right
Is FFE & MEE same