EG4 / Gyll Battery BMS Communication with Growatt inverters (5000ES and others)

Поделиться
HTML-код
  • Опубликовано: 9 сен 2024
  • Instructions for BMS communication between EG4 Batteries and the Growatt 5000ES Inverters
    BUY HUB: shop.signature...
    BUY 5000ES: shop.signature...
    BUY EGYLL 5.12kWh Packs: shop.signature...

Комментарии • 59

  • @michaelhouston1817
    @michaelhouston1817 2 года назад +7

    Just want to let everybody know the newest ES5000 only require one BMS cable into the master inverter. DO NOT USE the hub and plug into both. The grey communication cables now handle the BMS management between inverters. You’ll will have intermittent connection if you don’t follow this process.

    • @aymanbenothman9641
      @aymanbenothman9641 2 года назад

      Thank you so much for this info . I was just about to get the hup

  • @capamonkeyboy
    @capamonkeyboy 2 года назад +4

    On the Growatt SPF 3000TL LVM-48P I was able to make it work by connecting to the BMS port on the inverter, not the RS485. Same settings otherwise.

    • @temetnosce7482
      @temetnosce7482 2 года назад

      Exactly, same here - on the ES model.

    • @JonasTroyer
      @JonasTroyer 2 года назад +1

      What are your Protocol numbers for these inverters?

  • @DavidSelf3
    @DavidSelf3 2 года назад

    Thank you for explaining the dip switches. The instructions are good, but it's a little confusing with the newer lifepower4's. It says "reserved for communications"... This makes it so clear, thank you!

  • @brendao2496
    @brendao2496 3 месяца назад

    Thank you this is helpful

  • @Bazakilouis
    @Bazakilouis 2 года назад +1

    Are these growatt inverters use the fan when solar power just goes to the grid? Or is the fan only on when you use 48v to power the house ?

  • @elainemann5990
    @elainemann5990 2 года назад +1

    will this battery communicate with the sma sunny island inverters?

  • @CarnivoresinChrist
    @CarnivoresinChrist 2 года назад +1

    I have 2 24v Eg4 and was planning on running them in series for my 48v inverter. Is the setup for the BMS communication the same?

  • @Xxxcappie23
    @Xxxcappie23 2 года назад

    Great video. I'd like to know if the AC output of these inverters are connected together when you parallel inverters for single phase??

  • @RobbieHLM
    @RobbieHLM 2 года назад

    If I want to use these batteries on my mpp solar inverters, does communication also work. In the manual the eg4 batteries are not mentioned.
    If its not supported, can i still safely use the batteries while setting a user defined battery setting?

  • @DjStarlight12
    @DjStarlight12 8 месяцев назад

    How do you have the have the bms Lithium of Eg4 Comunicate with Deye Inverter

    • @SignatureSolar
      @SignatureSolar  8 месяцев назад

      If you're dealing with LifePower4, the EG4 Communication hub is your go-to for seamless communication with Dyness inverters. However, if you're working with LL-V1 batteries, don't forget to ensure they've got the latest firmware update for optimal performance.

  • @hanghubofficial1046
    @hanghubofficial1046 7 месяцев назад

    Do you have the protocol for the huawei 48v 100Ah battety with the growatt dpf 5000es

    • @SignatureSolar
      @SignatureSolar  7 месяцев назад +1

      We do not, if there is one, you would need to contact Huawei or Growatt.

  • @chrislewis9345
    @chrislewis9345 3 года назад +1

    Do you sell the inverter,breaker box,transformer already assembled?Or could you include the wiring diagram to assemble?

    • @SignatureSolar
      @SignatureSolar  3 года назад

      The Breaker box necessary varies depending on how large your Inverter Stack is, the transformer is plugged in just like another inverter.
      we do have general sketches on the sales page as well as a demo video on this channel for stacking with a transformer

  • @r-dub7966
    @r-dub7966 3 года назад +1

    Can you explain how to configure a system with 16 batteries ( 2 racks ) and 3 Growatt 5k inverters?

    • @SignatureSolar
      @SignatureSolar  3 года назад

      you need the 8 port hub, then you address all the batteries individually, the top battery that communicates with Growatt gets the address of 01, the op battery will communicate out of the RS485 port into the hub and you will connect each inverter via rs485 port into the hub as well, set the inverter battery mode to LI and parameter 01 as shown in the video

  • @MagallanesPR
    @MagallanesPR 2 года назад

    On another video, Your tech support, showing the LifePower 4's, stated that the DIP's had to be all ON (down position) to make it master, all other DIP's in any combo, as long as there is no repeat. Is the difference because of batt model?

    • @SignatureSolar
      @SignatureSolar  2 года назад

      Yes, they have different control boards so you must follow the instructions for each model.

  • @chrislewis9345
    @chrislewis9345 2 года назад

    Is it necessary to have the battery bank connected to the inverter?Is it doing anything more than relaying battery state of charge info to the inverter then its available to the wifi stick then your phone/tablet? If they are located in same room can't you just look at the batteries?I'm not knocking it just want as few wires as possible to have to hide.

    • @my92channel
      @my92channel 2 года назад +1

      Actually, it is very important to have the battery communicating with the inverter/charger, in order to get the best battery life, by having the BMS (battery management system) of the battery telling the inverter/charger what to do (in regard of charging/discharging voltage and ampers)

  • @JustaCuriousity
    @JustaCuriousity Год назад

    Hi, is the RS485 cable is the standard ethernet cable? Thank you.

  • @5slabs
    @5slabs 2 года назад

    For the new LifePo4s, if I parallel 2 batteries, the dip switches on master are all off (module 1) while the second is the third switch up (module 2)?

  • @RealEstateOttawa
    @RealEstateOttawa 2 года назад

    Followed the instructions 100% except I'm plugging directly into a single Growatt RS485 port and I get a Low voltage fault 04. If I move to the GW BMS port fault goes away.?? Further none of my voltages on the pannel switch to %? they still read in voltages? And voltage is near 53 volts so should not get a 04 fault.. Whats going on ?

    • @tahlularose9267
      @tahlularose9267 2 года назад

      On the newer ES models you only need to plug one comm cable into the BMS port, not the 485 port on the ES Inverter. And to get the % reading you need to select Li and then change the 036 parameter from L00 to L01 or Li will not lock in and give you the %.

  • @giuseppefasone5263
    @giuseppefasone5263 2 года назад

    Ciao
    Sai come fare comunicare lo stesso inverter con la pylontech us3000c?

  • @rogerlittlejohn475
    @rogerlittlejohn475 2 года назад

    Can the Growatt 300 communicate with other batteries? ie samsung ess sdi mega 3.3?

  • @aberba
    @aberba 3 года назад +1

    Is the rs485 cable the same as Ethernet? My Inverter and battery came without the cable and I'm trying to find one to buy but the search results are not quite clear. Growatt inverter and Rosen (China) battery setup

    • @wilson_hosn
      @wilson_hosn 2 года назад

      Any luck with finding if its the same?

    • @aberba
      @aberba 2 года назад +2

      @@wilson_hosn yes, they are the same. Although not all the 8 tiny internal cables are used when it's an rs485 port. It uses about 4 out of the 8.

  • @alandonnels7382
    @alandonnels7382 3 года назад

    Slightly off the subject and not using the Growatt inverters for this communication setup. Would the Growatt Charge controller have the same communication capability to talk to the EG4LL batteries? I have ordered 6 of the 48v batteries. My current system is has a Schneider XW6848 inverter but they use Xanbus for communications. With my luck I doubt there batteries would be able to communicate with my system. But I need to add more panels and an additional charge controller.

    • @SignatureSolar
      @SignatureSolar  3 года назад

      we have hought about making a BMS firmware for Xanbus

    • @Sparkeee1978
      @Sparkeee1978 3 года назад

      @@SignatureSolar similar question, will this be able to communicate with a Sol Ark inverter? I believe it uses Canbus over an RS485. I think it is stated as supporting the open source SunSpec 'draft 4' version for CanBus similar to SMA inverters... information is from september 2020 solar forum (can't verify acuracy) I'm not an IT programming guy... but I am a great electrician. thank you

    • @alandonnels7382
      @alandonnels7382 3 года назад

      @@SignatureSolar that would be awesome!

  • @machinery-plus1661
    @machinery-plus1661 3 года назад

    Does this apply to the 12kw - 150V inverter too? I can seem to get mine to communicate following this.

  • @Sparkeee1978
    @Sparkeee1978 3 года назад

    When did the EG4-LL batteries get the digital display etc. ? I paid for 6, and a rack the same day I got an email notification you had a large shipment coming in. this was early July. Are my batteries going to be these new version? or the old version? in the battery sales area, there are pictures of both types, and it is not clear what is being shipped. Thank you.

    • @SignatureSolar
      @SignatureSolar  3 года назад +1

      If your Batteries said LCD then yes, the LCD version will cost more and have a 10 YR warranty. the non-LCD LIFEPOWER4 has the 5 year warranty and the same growatt comms

    • @Sparkeee1978
      @Sparkeee1978 3 года назад

      @@SignatureSolar Thank you for the response. I called and setup my order for the newer LCD style, and am willing to wait for the next incoming shipment in order to get the LCD screen upgrade. The staff that have assisted me have always been great to deal with. Thank you

  • @gramos9115
    @gramos9115 Год назад

    Looking for a fix to an inverter shutdown issue , I came across this and it explains the settings really well , thank you .
    Every day I have to restart my 2 inverter/3x 200ah li batteries as it shuts down as soon as the batteries are full .
    the dipswitch buttons are all set to 1 so next they will be set 1/2/3 .
    I dont think the BMS is communicating with each battery as I am trying AGM setting .
    Any thoughts please ? its been running this way since installation May 2022 !

  • @wtrey333
    @wtrey333 3 года назад

    I've checked the specs for the EG4LL batteries on your site but cant seem to find the Lug size for wire that I attach. what type of Lugs do they use? 3/8" or 5/16"? And Can i connect 2 AWG wire directly to them?

    • @SignatureSolar
      @SignatureSolar  3 года назад +1

      6mm lug diameter. up to 100A of load/charge, 2 awg is fine

  • @DoctorPrepperMD
    @DoctorPrepperMD 2 года назад

    I ordered a rack a few days ago but the one you are using there has a cover and door! How do I get that one??

    • @my92channel
      @my92channel 2 года назад

      In order to keep the prices down, they don't have the door and the top anymore, they just have plastic shrouds over the buss bars.

  • @acefire4050
    @acefire4050 2 года назад

    Where are those batteries oh darn I don't have the money to buy even one of them well I guess it's something I can look forward to I would like to have 24 of those batteries.

  • @Badmonky666
    @Badmonky666 3 года назад

    Can the EG4LL be serialized? I was planning a 48V system.

    • @Badmonky666
      @Badmonky666 3 года назад

      just realized that i was confused because the only ones on the website available right now are 24V EG4 versions.
      When will the EG4LL come back in stock? And how much are they?

  • @dibeerwolf1645
    @dibeerwolf1645 2 года назад

    We , me and Drik Heimbürger , Need very urgend you technical support.
    We connect 3x for your Battery-pack (48V, 50Ah) in serial DC ( 144v , 50Ah) , and RS485 communication Cables .
    Then we connect the DC output to the Growatt Hybrid inverter SPH5000TL3 DC, and via CAN with an CAN-Cable also to the CAN - Plug of the Inverter.
    BUT Growatt Inverter can not communicate with YOUR Battery-Packs!??
    So, we need urgend , for YOUR application we use, technical support / connection plan scetch from your tecnical depatment.
    Also we must konw , how to set the dip-switches for each battery-pack (Master and slave settings for each Pack) ?
    Aslo we need to know , if we need special CAN cables or Special RS485 Cables????

  • @richarddietzen3137
    @richarddietzen3137 3 года назад

    EG4LL not ‘eagle’

  • @gm9666
    @gm9666 Год назад

    Sorry to say but these growatt are full of problems even the newer one .

    • @andyknowles666
      @andyknowles666 11 месяцев назад

      Funny, i've had a Growatt 5000es for a year now, it's been rock solid.

  • @sibusisotshabalala733
    @sibusisotshabalala733 2 года назад

    your email please i am having problem with my growwat inverter