nice transformer wind i just finished winding 3 12 gauge 198 turns with center tap high side out 120 volt and 240 volt here in the usa i still need to wind 24 or 25 turns for the 30 volt low side in i am making it for a home made inverter 10k watts i plug transformer into a outlet and test idle current with a clamp meter then i add 5 to 10 turns and test it again i do this to get the lowest idle current losses the core of this 10k transformer is 45 kg 1.24 turns per volt idle currant plugged into 120 volt outlet plug in is 0.06 when finished and installed in inverter the idle currant will be around a half of a amp from my 48 volt battery bank adding extra turns greatly lowers idle currant waste have a great day my friend
Hi, I need your help I have the toroidal core at OD=20cm, ID=7.5cm, H=9.6cm (weight= 19kg) so which size of wire can use for input and output to get 8000VA (input=220V, output: 144v-96v-48v-0-48v-96v-144v). Thanks I'm waiting for your reply.
sir transformer rewinding rule or formula sir example outer diameter 18cm inner diameter 9cm hieght 10cm outer diameter - inner diameter x hieght /2=core area 18cm - 9cm = 9cm x 10 = 90cm /2 = 45 cm core area
Sir tanong lang po ano po magandang gamitin na size ng magnet wire Toroidal core Outer diameter 18cm Inner diameter 9.4cm High 10cm Primary 220v Secondary 120v 60v 0 60v 120v Salamat sa sagot
Sir need of toroidal 70cm core area for 5000w For secondary 5000÷220v = 22.7amp Need magnetic wire 22.7 or 23amp For primary 5000÷28= 178amp Need magnetic wire 178amp For turn per volt 42÷70cm core area = 0.6turn per volt For number of turns of primary 0.6 number of turn x 28v = 16.8number of turns For secondary 0.6 number of turn x 220v = 132number of turns
26v secondary sayo mangagalingkung ano gusto mo secondary ang hanapin mo jan yun number of turns Example core area mo ay 45cm 42devided sa 45cm core area = 0.93turn per volt Seconfary na gusto ay 26v 0.93x 26v = 22number of turns bilang ng winding mo
ang 5000w is squareroot ng 5000 ang square root ng 5000 is 70.7cm yun core na ang outer diameter 18cm - inner diameter 9cm= 9cm x hieght 10cm = 90 cm core area over 2= 45cm yan ang wattage ng core na ginamit ko ay 21oowatts lng pero umabot sya ng 5000w dahil sa wire na ginamit ay pang 5000w yun magnetc wire ay # 10 with 21.2amp
@@rengiep28 sa actual computation Yun mga sir pero Ang ibig nya Sabihin ay mag advance sya Ng wattage using the wire size pero pag sinunod nyo Yung 2kw na power rating siguro mga asa gauge 22 at 18 Yung magagamit imbis na 10 gauge at 8 gauge
sir yan transformer na toroidal ang sukat nyan is 18cm yun outer yun inner is 9cm at yun hieght is 10cm 18cm -9cm = 9cm 9cm x sa hieght 10cm = 90cm 90cm devided by 2 or 90cm /2 =45cm core area 45cm equals 2100watts 2100watts over 240v = 8.75 amperes yan ang sukat ng magnetic wire na gagamitin mo sa primary ang numbert of turns ng magnetic is 42 over sa core area 45cm or 45cm /42 na constant = 0.93 turns per volt 0.93turns per volt x sa 240volts = 223.3 number of turns yan ang bilang ng primary 223.3 number of turns ang magnetic wire ay 8.75amp gauge= 14 or 13 sa secondary naman 0.93turns per volt x 70v =65.1 number of turns x 2 dahil 70 0 70 65.1 x 2 = 130 number of turns ikot mo yun 65turns tapos center tap tapos ikot ulit yun 65turns para sa dalawang 70v and then primary naman ay 12volts 0.93 x 12volts= 11.16 number of turns para sa 12volts 11.16 x 2 = 22.32 number of turns para sa 12v 0 12v ang tanong ilan transistor ang gagamitin mo sa amplifier mo 10pcs sa right channel at 10pcs sa left channel ang transistor ay 1.3 ampere each 10pcs transistor x 1.3amperes = 13amp ang gagamitin mo magnetic wire is equal ng 13ampere gauge 12 ang wattage ng power amplifier mo 70volts x 13 ampere = 910watts per channel RMS yun secondary mo na 12volts maliit lang na secondary magbetic wire gagamitin mo dahil sa preamp or tone control lang naman gagamitin pwede na gauge 18 equal 3ampere yun 910watts mo na amplifier pwede mo gawin 2100watts dahil nag transformer mo ay 2100watts
example sir 18cm outer - 9cm inner = 9cm hieght x =90cm devided by 2= 45cm core area 42constant devided 45cm core area = 0.93 turns per volt primary 220v x 0.93 turns per volt = 204number of turns plus 20turns 224number of turns para sa 220v secondary 12v x 0.93 turns per volt = 11number of turns volt
Sir squareroot ng 5000 =70 Yun 70cm yun ang size ng core ng 5000w Yun ginawa ko sir 45cm lng yun core Hinabol ko lng sa size ng wire yun 5000 pero pag ganyan setup malakas mag init ang core dspat talaga 70cm ang 5000w
@@aesvlog8056 pag 18cm po hanggang ilan ang kaya na wattage balak kopo kc gawing tatlo yung wire ng bsecondary ko para maging 3kw kayanin kaya ng core ko yun sir 7cm po yung butas nya tapos ang kapal ay 6.5cm hanggang ilang max wattage po ang pwede sa core ko
@@jboy4real transformer general rule given a 42/core area = number of turns x volts 42/45cm2 core area = 0.93turns per volt 0.93turns per volt x 24v secondary winding = 22.32 number of turns for secondary winding at 24volts
Sir pa help ako gagawin Kong 1000w Yung core ko na 737 toroidal transformer. Dating 500w Gawin Kong 1000w ngayon. Ang sukat ng core is D1 - 12 CM D2- 6.2 CM HIGH - 7 CM
pag sa inverter gagamitin yun primary gawin mong 6.5volts para sa 12v sysem at yun primary depende sattage ng inverter mo tama sa inverter ko ginamit yan ginawa kong 5000w yan input and output or primary and secondary
42 constant ÷ 45cm core area = 0.93 turns per volt 220v x 0.93 turns per volt = 204 number or turns 204 number of turns + 20 turns = 224 number of turns yun 20 turns option lng yun para kung tumass yun power ni grid sa 240v ndi mag init yun transformer mo
Watching for the second time sir di pa malinaw sa akin kng paano mo na compute yong wattage wala kang formula sir pakiexplain po kng paano mo nakuha yong given na 5000 watts sir
@@aesvlog8056 sir di ba ang computed na area of core is 45 tapos yong given mo ay 42 dinivide mo 42/45 tapos may product na .90 something na turns per volt tapos minultiply mo sa input voltage kaya na compute mo ung primary turns sir .Tapos saka may given na 5000 saka mo idinivide power over input voltage nakuha mo ung amperes tapos may katumbas na number of magnetic wires yong product ng formula don lng ako nacomfuse sa given na 5000 watts sir
@@aesvlog8056 sir pag kinompute mo sir yong square root of 5000 ang product almost 70 ang lumalabas na area of core sir malaki po ang disparity sa computed na area of core sir na 45 tama po ba ako sir
Sar namaskar sar Hindi mein samjhaie sar aapki Bhasha samajh nahin aati hai sar aap kis bhasha mein baat karte hain please sar Hindi mein samjha dijiye iska data hamen aapki Bhasha nahin samajh mein aati hai aap kya bolate Hain kya nahin bolate hain aur jo likhkar data samjhate Hain usko itna camera najdeek rakhe jisse likha hua samajh mein a jaaye kya likh rahe hain aap Hindi mein samjhaie sar please Hindi mein
Wow..Very much informative... New friend.
yan si idol galing magturo salamat nandyan ka para sa gusto matuto mag diyer godbless po❤️❤️❤️🙏🙏🏼
tnx din po sir
Good video for learning...thanks
nice bro keep it up thanks for sharing
Tolaidal rewind tutorial gandang tutoring very informative
Rewind and tutorial Toroidal Transformer calculator very impormative information po
Thank you for the information
Sir salamat po ng marami, nagawa ko an toroidal trans. Dahil s blag mo, . Salamat kahit wala akong alam sa eleCtronics na get ko
Nice content sir nasunog po kc transformer ng avr ko...malaking tulong to..thanks po
ok sir
Thanks for sharing this informative content lods keep safe
Nice full part broe
More power & God Bless Sir.
Thanks for sharing idol...lablab lab
Thanks a lot for very nice vdo
thanks po sir
nice transformer wind i just finished winding 3 12 gauge 198 turns with center tap high side out
120 volt and 240 volt here in the usa i still need to wind 24 or 25 turns for the 30 volt low side in
i am making it for a home made inverter 10k watts
i plug transformer into a outlet and test idle current with a clamp meter then i add 5 to 10 turns and test it again
i do this to get the lowest idle current losses
the core of this 10k transformer is 45 kg 1.24 turns per volt idle currant plugged into 120 volt outlet plug in is 0.06
when finished and installed in inverter the idle currant will be around a half of a amp from my 48 volt battery bank
adding extra turns greatly lowers idle currant waste
have a great day my friend
tnx sir for watching
could you pls tell me how many turns per % you add for lower idle current than Τhank you very much have a nice day
New subs idol.. salamat sa kaalaman ❤❤❤
tnx po sir
Thnks for sharing sir
hello po thaks for sharing idol
sending my support idol
wow naman
A+ ❤👍
Nice content thanks for sharing this, keep vlogging po #Anna
Nice intro
Good Eve sir,new subscriber,nice content sir.,pwedeng paturo sir?parang alanganin pa ako sa mga ideas na nagather ko.newbies pa.
I already looked for it in shopee and I didn't find it. There's a way you can send me the link to buy it in shopee
Hi friend,nice video, done!!👍🔔👈🇲🇽💙💙💙💙💙💙
Idol sana sa sunod may tutorial kayo sa 3 tier na transformer para may idea ako☺️ thank you for sharing
cge sir add mko fb turuan kita sarmiento e ariel fb ko
@@aesvlog8056 cge sir patulong Ako pag compute pag makabili na Ako core sir salamat
@@user-he7rq6zj5c dyan sa bagong video meron computation sir
@@user-he7rq6zj5c ruclips.net/video/Txn08asVt84/видео.html
paki open na lang po
nice
Sir sunod mo pong video yung Iron transformer kung paano magrewind
ok sir copy po
Boss paano mo nakuha yong constant na 5000 watts paki explain master wala ng pagkaligaw ksi computed na yong haba nice presentation tnx sa video sir
masyadong malaki ang wattage na 5k jan.. as will as the primary awg.. pang secondary na yon
very informative video..#healer777
Kung #15 lang po primary ko, ok na po ba yung 1kg na awg#15? D ko po kasi alam kung ilang meters po 1kg nun ei
Continue share and blogging#jake dawn
Thank you po for sharing! Healer777
Boss pwede mag tnong kong ano ang katapat na magnit wire nomber 806.4 watts
Sir san po ba mabili ung iron core toroid na 4x7x3.5x2 at magkano po
I'm confuse on how to select wire guage what wire guage will i select for 125amps of current.
Thanks
How did you calculate the secondary ampare
Sa.an galing ang 2 sir
Ser pwd parin bayung # 10 secondary 50 0 50 ac ganyan din po core nabili ko
pwede sir
Idol, paturo naman pano mag rewind ng toroidal na stepdown, 230v to 24v + 17v :) salamat Idol.
Pm mko
Sarmiento E ariel fb account
Sir tanung kulang mga ilang perHe kayang abutin ng core
Hi, I need your help I have the toroidal core at OD=20cm, ID=7.5cm, H=9.6cm (weight= 19kg) so which size of wire can use for input and output to get 8000VA (input=220V, output: 144v-96v-48v-0-48v-96v-144v).
Thanks I'm waiting for your reply.
sir fb account sarmiento e ariel
@@aesvlog8056 I see only Johan Sarmiento
Sir tanung kulang po mga ilang klg ang primary thankz po
Sir saan po bnda shop nyo?may pagwa sana ako
Basta Ako legit yarn hehheheh👏👏👏👏🤣🤣🤣pag ayaw nio manila d wag hahhaha😊😊😊😊baka itik mga yarn😁😁😁
Why did you divide the 90cm^2 by 2
sir transformer rewinding rule or formula
sir example outer diameter 18cm
inner diameter 9cm
hieght 10cm
outer diameter - inner diameter x hieght /2=core area
18cm - 9cm = 9cm x 10 = 90cm /2 = 45 cm core area
Sir tanong lang po ano po magandang gamitin na size ng magnet wire
Toroidal core
Outer diameter 18cm
Inner diameter 9.4cm
High 10cm
Primary 220v
Secondary 120v 60v 0 60v 120v
Salamat sa sagot
Sir saan mo gagamitin at ano wattage ng paggagamitan
18 / 9 / 10
18 - 9 = 9 x 10 =90cm
90cm ÷ 2 = 45cm²
2000w sir
Sir sa.an mo nabeli ang transpormer mo yan nalang dn belhin ko salamàt
pwede parin po ba yung awg#10 sa secondary na 65vac
pwede po mattas din po ampere ng awg 10
Apa kalinaw tlaga mag paliwanag boss
bs may toroid ako dito galing sa 5kva na avr, pwede ko na ba lagyan ng secondary ito?
Pwede sir
ruclips.net/video/-9i3YyY2egA/видео.html
Watch mo to sir
Magkano po lahat gastos dyan sir?
Sir can I use speaker magnet for toroidal transfarmar
sir metal sheet for low freq transformer and ferrite core for high freq transformer
@@aesvlog8056 thank you sir
How do you calculate the wire size for inverter transformer with secondary 28v for 48v battery
28v for 48v battery system for what wattage
@@aesvlog8056 for 5kva inverter
Sir need of toroidal 70cm core area for 5000w
For secondary 5000÷220v = 22.7amp
Need magnetic wire 22.7 or 23amp
For primary 5000÷28= 178amp
Need magnetic wire 178amp
For turn per volt 42÷70cm core area = 0.6turn per volt
For number of turns of primary
0.6 number of turn x 28v = 16.8number of turns
For secondary 0.6 number of turn x 220v = 132number of turns
@@aesvlog8056 Good day Sir, ilan po kaya total cost ng materials nito ? Ty po.
@@5iCn4rF dir saan po gagamitin sa amplifier po ba or sa inverter
ilang kilo bayan 206 turns bos salamat
Saan mo nkuha yung 26v sa secondary master??
26v secondary sayo mangagalingkung ano gusto mo secondary ang hanapin mo jan yun number of turns
Example core area mo ay 45cm
42devided sa 45cm core area = 0.93turn per volt
Seconfary na gusto ay 26v
0.93x 26v = 22number of turns bilang ng winding mo
sir pwd sa step up pang power amp
pwede po sir message mko sa fb ko ariel enriquez sarmiento turuan kita para sa power amp
Dapat apat yan pag na pair NG number 8 para 100a
ok na sir ginamit ko sa inverter ginawa kong 16pcs magnetic wire
Amigo onde eu compro esse transformador
sir / friend i buying at shopee online market
sir thanks for watching and support
I already looked for it in shopee and I didn't find it. There's a way you can send me the link to buy it in shopee
shopee.ph/product/260904219/5247751581?smtt=0.430413425-1670723248.9
Sir pwede pashare Ng chart Ng magnetic wire base sa volt or current?
sa messenger sir ano messenger mo sir
san po kayo nakbili ng toroidal core sir?
sa lazada po sir nanajan po yun video nng nag open po ako ng box galing lazada sir
Pa send NG link Saan na bili yan lods
sa shopee po sir hanapin ko po yun link
where i can get the steel core?
Order online
mag papagawa po sana kami transformer
Tutorial lng po ako sir
may messenger po kayo
45cm squared core area
45x45=2025watts..
Di po ba yan yung wattage na pwede lng sa core sir?
sir ang 5kw ay squareroot ng 5000
ang 5000w is squareroot ng 5000
ang square root ng 5000 is 70.7cm
yun core na ang outer diameter 18cm - inner diameter 9cm= 9cm x hieght 10cm = 90 cm core area over 2= 45cm yan ang wattage ng core na ginamit ko ay 21oowatts lng pero umabot sya ng 5000w
dahil sa wire na ginamit ay pang 5000w yun magnetc wire ay # 10 with 21.2amp
pero pag sinabing 5000w ndi mo naman magamit yun 50000w sir
ang nagamit lng sa lanya ng actual ay 42000w
@@rengiep28 sa actual computation Yun mga sir pero Ang ibig nya Sabihin ay mag advance sya Ng wattage using the wire size pero pag sinunod nyo Yung 2kw na power rating siguro mga asa gauge 22 at 18 Yung magagamit imbis na 10 gauge at 8 gauge
Sir tanong lng po saan po kinuha ang 26 Volt sa secondary winding po sir
sa winding po yun 26v yun 26v po number of turns is 54 po para maka buo ng 26volts
@@aesvlog8056 ahh okey po sir salamat
tanong lang po sir pag sa inverter ko gagamitin yan na compute same lang po ba?
same lng po sa inverter nga po gagamitin tong ni rewind ko po watch nyo mga next upload ko po pakita ko po na working po sya sa inverter
sir pag meron tanong pm mko sa messenger po ariel enriquez sarmiento po sa fb
bihira po kasi ako mag basa ng commennt nag work po kasi ako
@@aesvlog8056 ok po sir salamat...try gumawa para sa sunyima brand sa shopee ko binili..5000to 6000watts.
Magkano bili niyo diyan sa iron core?
21oo sa shopee po sir
panu boss pag 65vac yung secondary?? bababa po ba ampere ng awg?
ok lng 65vac basta kaasya pa wire sa core pero kung ndi kasya baba taalaga ampere kasi maliit na wire diameter gagamitin mo para mag kasya sa core
sir pag meron tanong pm mko sa messenger po ariel enriquez sarmiento po sa fb
bihira po kasi ako mag basa ng comment nag work po kasi ako
ilang seconday ampere iyang bossing
nadyan na po sa video kung ilang turns primary secondary at amperes ng primary at secondary at nadyan na din ang voltage ng primary at secondary
saan pwedi maka bili nyan boss ng iron core?
SA shoppe sir
sir tanung kulang po mga ilang ikut po ang 120v sa secondary awg#10
sir saan nanggaling ung constant na 42?
50HZ
Sir gdpm Tanong po ako paano Ang computation kpag mgduoble output k halimbawa 220in tpos out ko 70 0 70 at Saka 12 0 12 paano icompute Ang 12 0 12?
sir yan transformer na toroidal ang sukat nyan is 18cm yun outer yun inner is 9cm at yun hieght is 10cm
18cm -9cm = 9cm
9cm x sa hieght 10cm = 90cm
90cm devided by 2 or 90cm /2 =45cm core area
45cm equals 2100watts
2100watts over 240v = 8.75 amperes yan ang sukat ng magnetic wire na gagamitin mo sa primary
ang numbert of turns ng magnetic is 42 over sa core area 45cm or 45cm /42 na constant = 0.93 turns per volt
0.93turns per volt x sa 240volts = 223.3 number of turns yan ang bilang ng primary 223.3 number of turns ang magnetic wire ay 8.75amp gauge= 14 or 13
sa secondary naman 0.93turns per volt x 70v =65.1 number of turns x 2 dahil 70 0 70
65.1 x 2 = 130 number of turns ikot mo yun 65turns tapos center tap tapos ikot ulit yun 65turns para sa dalawang 70v
and then primary naman ay 12volts
0.93 x 12volts= 11.16 number of turns para sa 12volts 11.16 x 2 = 22.32 number of turns para sa 12v 0 12v
ang tanong ilan transistor ang gagamitin mo sa amplifier mo 10pcs sa right channel at
10pcs sa left channel
ang transistor ay 1.3 ampere each
10pcs transistor x 1.3amperes = 13amp ang
gagamitin mo magnetic wire is equal ng 13ampere
gauge 12 ang wattage ng power amplifier mo 70volts x 13 ampere = 910watts per channel RMS
yun secondary mo na 12volts maliit lang na secondary magbetic wire gagamitin mo
dahil sa preamp or tone control lang naman gagamitin pwede na gauge 18 equal 3ampere
yun 910watts mo na amplifier pwede mo gawin 2100watts dahil nag transformer mo ay 2100watts
isulat mo sir para malinawan ka kopyahin mo yan ginawa ko as reference mo
Sir salamat sa maliwanag mong sagot sa Tanong ko God bless you po.
tnx din po sir
keep sharing
sir pwidi po pahingi aq copy ng computation mo. thank po pag aaralan ko lng po . guzto ko rin po kc matuto ng pag rrewind...
anu po messenger nyo send ko sa messenger nyo po sir
Sir pashare Ng copy😅☺️
Sir yung constant po ba, yung isang ikot sa core tanong ko lng po
sir ang constant po yun 42 para sa turns per volt kasi yun isang ikot pag malaki or maliit ang core mo hindi papasok sa 1volt
example sir 18cm outer - 9cm inner = 9cm hieght x =90cm devided by 2= 45cm core area
42constant devided 45cm core area = 0.93 turns per volt
primary 220v x 0.93 turns per volt = 204number of turns plus 20turns 224number of turns para sa 220v
secondary 12v x 0.93 turns per volt = 11number of turns
volt
@@aesvlog8056 ty po sir
Omabut ba nq 1kilo poba yunq primary? Sir
umabot sir kulang pa
Ilanq killo Po sir
@@jorexcabatuan less than 3kls
Marami yun primary ginamit ko sa inverter yun toroidal na yan
Sir anubg formula ginamit mo para malaman na kaya ng core mo ang 5kw.. Tnx po sa sagot
Sir squareroot ng 5000 =70
Yun 70cm yun ang size ng core ng 5000w
Yun ginawa ko sir 45cm lng yun core
Hinabol ko lng sa size ng wire yun 5000 pero pag ganyan setup malakas mag init ang core dspat talaga 70cm ang 5000w
@@aesvlog8056 maraming salamat po sa pag sagot sakin kc 18cm lang tapos awg9 ang secondary nya 13v sabi nung nag rewind 1kw da yun 50 ampere
@@aesvlog8056 pag 18cm po hanggang ilan ang kaya na wattage balak kopo kc gawing tatlo yung wire ng bsecondary ko para maging 3kw kayanin kaya ng core ko yun sir 7cm po yung butas nya tapos ang kapal ay 6.5cm hanggang ilang max wattage po ang pwede sa core ko
sir pm mko turuan kita
@@eugenebrizuela7745 Sarmiento E Ariel fb ko
Saan po ba nakukuha boss constant
42 constant sir sa transformer rule
Sir San po nggaling 90cm/2 ung 2 San po ng galing salamat
outer diameter 18cm subtract sa inner diameter 9cm = 9cm x 10cm hieght = 90cm
Kaya ba 6kwatts sir?
4200 lng sir sagad umiinit pag mataas sa 4200watts
Plzz on captions
ok sir next time
How did you get 30ampare for secondary winding
30amp for secondary is 3pcs of awg# 13 magnetic wire
awg # 13 equavalent to 10.5amp x 3pcs = 30.15 amp for secondary
@@aesvlog8056 your transformer is 5kva and you secondary voltage from the battery is 24v how come you calculate 30 ampare
@@jboy4real 30amp 3pcsmagnetic wire awg # 10 equavalent 10.5ampx3pcs = 30.15amp
@@jboy4real transformer general rule given a 42/core area = number of turns x volts
42/45cm2 core area = 0.93turns per volt
0.93turns per volt x 24v secondary winding = 22.32 number of turns for secondary winding at 24volts
@@aesvlog8056 okay
Nice idol may nabili po ako shoppe 5000 watt na bord balak kopo boohin diy para maka tipid
ano yun red board
watch mo yun gawa ko sir marami ako video paki watch sir meron din ako 5000w inverter board kulay pula
@@aesvlog8056 hindi pa po dumating ad mopo ako masanger idol
@@aesvlog8056 oponidol pila po
@@marlonbrioso7599 ano messenger mo idol
Idol saan ka naka order ng Toroidal core at magkano?
shp.ee/ib81ykt
Shopee sir
boss electrical tape ba yan gamit mo
elecrtical tape pero meron nabibili na cotton na para dyan sa core
@@aesvlog8056 ano kaya pangalan na cotton jan sir
@@johnlloydanora9367 sa shopee sir meron
Saan po galing ung 5000Watts n power?
sir sa sukat ng core
squareroot ng 5000 is 70.7
yun sukat ng core ay 70cm kaya 5000w
Sir pa help ako gagawin Kong 1000w Yung core ko na 737 toroidal transformer. Dating 500w Gawin Kong 1000w ngayon. Ang sukat ng core is
D1 - 12 CM
D2- 6.2 CM
HIGH - 7 CM
add mko sa fb turuan kita sir
sarmiento e. ariel fb ko
@@aesvlog8056 done na sir
@@reynellabrada1447 ok cge pag nag open ako fb confirm ko
@@reynellabrada1447 sir anong fb account na add mo po
Sir, poydi po bang gamitin yan sa inverter?
pag sa inverter gagamitin yun primary gawin mong 6.5volts para sa 12v sysem at yun primary depende sattage ng inverter mo tama sa inverter ko ginamit yan ginawa kong 5000w yan input and output or primary and secondary
watch mo mga videos ko para makita mo mga diy inverter
@@aesvlog8056 Sir kung sakali ba poydi po ako mag pa gawa nalang ako sayo ng Inverter gamit yung ganyang 5000 watts toroidal transformer?
@@orabilesvlogs3190 taga saan ka sir
@@aesvlog8056 pasig po Sir pero sa kasalukyan ay nasa abroad po.
San po nang galing si 2?
given po yun galing sa formula ng transformer rewind
outer diameter - inner diameter × hieght
18cm - 9cm = 9cm x 10cm hieght = 90cm ÷ 2 = 45cm core area
42 constant ÷ 45cm core area = 0.93 turns per volt
220v x 0.93 turns per volt = 204 number or turns
204 number of turns + 20 turns = 224 number of turns yun 20 turns option lng yun para kung tumass yun power ni grid sa 240v ndi mag init yun transformer mo
kung 12v ang secondary mo naman
12v x 0.93 turns per volt = 11 number of turns
if ever na 1000w yun need mo gawin sa transformer mo
1000w ÷ 220v =4.5amp
ang need mo na magnetic wire is 4.5 amp gauge # 16
Master pwdi po bang mkahinge sayo ng compution ng 10k watts pm kta sa messenger mo Master....
ok cge
cge ano messenger mo
Watching for the second time sir di pa malinaw sa akin kng paano mo na compute yong wattage wala kang formula sir pakiexplain po kng paano mo nakuha yong given na 5000 watts sir
sir sa calculator type mo yun squareroot ng 5000 ang equavalent 70.7
yun toroidal core ay pasok sa 70.7cm kaya 5000
sir pm mko sa messenger turuan kita sir
ariel enriquez sarmiento sa fb ko sir pki pm lng ako turuan po kita sir
@@aesvlog8056 sir di ba ang computed na area of core is 45 tapos yong given mo ay 42 dinivide mo 42/45 tapos may product na .90 something na turns per volt tapos minultiply mo sa input voltage kaya na compute mo ung primary turns sir .Tapos saka may given na 5000 saka mo idinivide power over input voltage nakuha mo ung amperes tapos may katumbas na number of magnetic wires yong product ng formula don lng ako nacomfuse sa given na 5000 watts sir
@@aesvlog8056 sir pag kinompute mo sir yong square root of 5000 ang product almost 70 ang lumalabas na area of core sir malaki po ang disparity sa computed na area of core sir na 45 tama po ba ako sir
Blard Ang pagkauha mg camera.
cencya na sir cellphone lng gamit ko
Sar namaskar sar Hindi mein samjhaie sar aapki Bhasha samajh nahin aati hai sar aap kis bhasha mein baat karte hain please sar Hindi mein samjha dijiye iska data hamen aapki Bhasha nahin samajh mein aati hai aap kya bolate Hain kya nahin bolate hain aur jo likhkar data samjhate Hain usko itna camera najdeek rakhe jisse likha hua samajh mein a jaaye kya likh rahe hain aap Hindi mein samjhaie sar please Hindi mein
sir you are indian
Boss pwede mag tnong kong ano ang katapat na magnit wire nomber 806.4 watts
anu voltage sir
dapat sir meron voltage primary at secondary para malaman po size ng wire po
anu po voltage na gagawin nyo sa primary at seconday
sir saan nanggaling ung constant na 42?
Sa computation Yan Ng toroid pero pang cm pero pag inches 5 to 6.5 Yung constant
Depending sa core type mas maganda mas mababa Yung constant