Oh Mod God, It has been finished in the very vital moment:(( How to size a pump ? How to Design Sprinkler system with Fire Hose Cabinet and without ? What should be the head of pump ?? Please, share video with that topics, really need
An excellent presentation on the topic & One of the best videos on youtube regarding fire protection engineering. Do you have any plan to conduct training or presentation on CFPS exam preparation?
I understood preaction system but when heat detector senses smoke then water will release from sprinkler my question is that in a particular effected area's sprinkler only will release water while Heat detector senses smoke
Hi allow us to handle this query. Sprinklers are convective devices and they trigger with heat release from a specific device. Sprinklers (bulb type) tend to work on expansion of liquid principle allowing the bulb to break down and allowing water to drop on deflector to provide a specific pattern.
Sir, i have a 30 guess rooms for an inn's project. My concern is that we need an enclosed pump room at roof top? or just let the pump room open concept? thanks
If you are in India, it's as per NBC guidelines, if it comes under residential Building, they just need an overhead tank and a booster pump connected to hose reel and hydrant as required. It is mentioned in NBC 2016 TABLE 7
@SM TECHNO MEP & NLP TRAINING SERVICES : Hello Sir, I like the way you explained. Am Anil Kumar Fire Consultant from Hyderabad and doing liasioning to get the approval from Local Fire Authority. Here Local Authority people purely following NBC Part-3, Part-4 & Part-8 & Local GOs for issuing No Objection Certificate. For design consideration i am following NBC, BIS & NFPA-13. So Please suggest if any Fire Engineer courses in India..?
@anilkumar Sir, I also want to become a fire consultant in Maharashtra and also want to do liasioning work. What qualification or degree should I take as I have completed graduation
Always watching again and again from Middle East Saudi Arabia KSA OFW PILIPINO MIGRANTS WORKING ABROAD INTERNATIONAL WORLD 🌍🌎 WIDE Globally OFW PROFESSIONAL JOBS in 24 / 7 viewing live streaming online unlimited video clear sounds great listening 🎧 in 3 X a day in every day....
Sir, We are designing a foam base deluge sprinkler system as we have combustible solid and liquid material tanks. So, my question is, How many no. of open type sprinklers should be on 1" or 2" line for Ordinary Hazard Group 2 and what should be the density of the water used for this system.?
Great Class, very clearly explained everything...Thank You Sir for sharing your knowledge.
Good work boss am a fire fighter in Kenya and I have learned a lot
Watching also from Kenya
Great job sir by Robert.Tamilnadu safety council.Secretary
hi sir when we using the yard hydrant its need to reach the terrace?
Great job
Hi, knowledgeable video for all beginners in fire fighting field.
Good work
Ultimate teaching, very good knowledge
Thanks much for the knowledge understanding the system better a plumber based in Kenya
Great class , helpful to learner
Hello Boss. I'm your new student. Thanks for sharing information Fire
Love this product. Easy to use. Works great.
00
20:53 class 3 fire prevention Goals
23:25 Types of Fire Protection systems
Thanks very much for the explanation
Put some subtitle to the people whot dont understand your accent. Your videos viewed nationwide!
Will update soon
Good to knowledge
Good work 🔥
Great sir...
Great explanation, sir can I get this notes
I appreciate your effort
Thank you very much, it is very useful and very sequential and systematic approach...
Hi sir you doing a good now i am coming to the point, if we using the yard hydrant , water need to go top most floor its necessary or not
thank you, bro.
Do u have O&M manual of fire fighting system
Sir you don’t have complete lectures of certified fire protection specialist.
Very beautiful explanation
Oh Mod God, It has been finished in the very vital moment:(( How to size a pump ? How to Design Sprinkler system with Fire Hose Cabinet and without ? What should be the head of pump ?? Please, share video with that topics, really need
Amazing course sir.please create and plumbing and electrical too
Will upload soon
Well explain good
Excellent PPT and explanation. Really haertfully thanks for u sir
What's the price of online classes
great ♥
NICELY EXPLAINED
Great keep it up...
Very informative. Kudos! By the way, if an equipment is UL Listed, does it automatically means that it is also Fire Rated?
???
An excellent presentation on the topic & One of the best videos on youtube regarding fire protection engineering. Do you have any plan to conduct training or presentation on CFPS exam preparation?
What a great explanation sir.......
Sir would you like to provide us in pdf format....
I don't think he will....
I understood preaction system but when heat detector senses smoke then water will release from sprinkler my question is that in a particular effected area's sprinkler only will release water while Heat detector senses smoke
Hi allow us to handle this query. Sprinklers are convective devices and they trigger with heat release from a specific device. Sprinklers (bulb type) tend to work on expansion of liquid principle allowing the bulb to break down and allowing water to drop on deflector to provide a specific pattern.
Sir, i have a 30 guess rooms for an inn's project. My concern is that we need an enclosed pump room at roof top? or just let the pump room open concept? thanks
If you are in India, it's as per NBC guidelines, if it comes under residential Building, they just need an overhead tank and a booster pump connected to hose reel and hydrant as required. It is mentioned in NBC 2016 TABLE 7
Sir can you explain in hindi and urdu mixed language.....?? So we can understand in....
Great Video , Hope such video for plumbing too.
Will upload soon
Good work. Keep it up
@SM TECHNO MEP & NLP TRAINING SERVICES : Hello Sir, I like the way you explained. Am Anil Kumar Fire Consultant from Hyderabad and doing liasioning to get the approval from Local Fire Authority. Here Local Authority people purely following NBC Part-3, Part-4 & Part-8 & Local GOs for issuing No Objection Certificate. For design consideration i am following NBC, BIS & NFPA-13. So Please suggest if any Fire Engineer courses in India..?
@anilkumar Sir, I also want to become a fire consultant in Maharashtra and also want to do liasioning work. What qualification or degree should I take as I have completed graduation
Hi Sir, you can always join online courses
@@BaskanCorporation does online courses hold validity in comparison to state board approved courses?
Can you suggest courses as well?
Sir, i just Love your channel. Please make a video on chiller & pump valve mock up.
many many thank you sir
Kya baat Hai.. Ilm baatn a aapse sikhe
Always watching again and again from Middle East Saudi Arabia KSA OFW PILIPINO MIGRANTS WORKING ABROAD INTERNATIONAL WORLD 🌍🌎 WIDE Globally OFW PROFESSIONAL JOBS in 24 / 7 viewing live streaming online unlimited video clear sounds great listening 🎧 in 3 X a day in every day....
Great video sir, can u please make video for extinguisher location in drawing
Sir,
We are designing a foam base deluge sprinkler system as we have combustible solid and liquid material tanks.
So, my question is,
How many no. of open type sprinklers should be on 1" or 2" line for Ordinary Hazard Group 2 and what should be the density of the water used for this system.?
3 to 4 for 2inch
Nice Video. Could you share the power point ?
May Allah give you the strength and more knowledge. Thank you for sharing this amazing information.
❤
Sir, please pipe schedule design classes
Available in live online paid training
@@SMTECHNO-MEP please share these pdf notes....
Assalamualaikum
where can i find the documents
@SM TECHNO MEP & NLP TRAINING SERVICES ...... Plz share these pdf notes......
Notes and data will provide only with complete paid courses
can tell me what is distance between two sprinkler.
for ordinary hazard
for light hazard
for high hazard..
and in NFPA where it is written plz ans
Excellent video. Are online paid classes being conducted now?
Yes, please contact us on WhatsApp +91-9848699535
sir please make video on basement sump calculation ...( assuming maximum area of operation of sprinkler )
Add auto subtitle for this video
Where is second part for this video
क्या ये हींन्दी में वीडियो दे सकते हो?
where can i get the pdf?????????
any one please share NFPA 10,12,13,22,24 and other it is difficut here in my location
Please message me on whatsapp +919848699535
Asak
Do u have O&M manual of fire fighting system
hi, how can i buy ur notes?
Mujeh course kerna hai
sir can i get this pdf please upload
\
..
I want u r mobile