SIR, Mera Commissioning pe nokri laga hei ADANI power(800×2) , jharkhand pe.. contractual job hei..or collage campus se mila hei...to mujhe Jana chahiye ya others koyi company ke liye try koru.. please boliye
Sir hamare boiler ki efficiency nikalna hai Warking pressure 109 Boiler 135tph ka hai Husk clorofik value 2250 hai Hamare boiler ki hiting surfers 7022m2 hai Tempture 540+_ 5°hai Sir please efficiency nikalna hai
Very helpful and excellent live video plant self condition and plant light up live DCS operation video bhi banana sir...Thank you so much
AFBC boiler lightup system ko DC's se live dikhaye n sir please
EXCELLENT JI 🙏🙏
Good explain sir....
Nice sir 👌
Very good bhai
Thanks bhai
Thanks sir
Slop fired boilerke baare me bhi kuch btaye
👍
Sir Turbine ka bhi video banaiye
Fcc unit & indmax unit ke upaar video banaye
सर् Slop fired बॉयलर के बारे में भी एक वीडियो बनाइए प्लीज
Very soon dear I'll make
OK Sir
AFBC boiler light up kei barey mein bhi video banaiye sir please.....
Sure dear very soon I'll make
Sir, please upload a video about cold light up
Pls mention about LDO pump and oil burner to achieve bed temperature
R you working in shyam group. How you take this graphics & design ?
Sir hot and cold burner me kya anter hai
Sir AFBC boiler Dcs video karun please.....
Sure dear
Sir ji please make vedio corrosion coupon work in cooling tower pl
Sir deaerator me tempture jada kew nahi de sakte hai
Hydrazine ka reaction 89° to 200° temperature range hota h, jyada krne se hydrazine dusra function krne lgta h
I am operate boiler CFB from indo 🙏
Sir, please tell me electrical and instrument control circuit diagram
Sir ,yehi boiler pe FD fan Nahi hai
Ni dear ye CFBC h n
SIR, Mera Commissioning pe nokri laga hei ADANI power(800×2) , jharkhand pe.. contractual job hei..or collage campus se mila hei...to mujhe Jana chahiye ya others koyi company ke liye try koru.. please boliye
Ekdm se join krna chahiye dear, bahut acha Apportunate h
powerplantdiscussion@gmail.com
Sir Boiler start up time pe hum log FCV Kitna % open rakhte hai
According to water requirements
Sir hamare boiler ki efficiency nikalna hai
Warking pressure 109
Boiler 135tph ka hai
Husk clorofik value 2250 hai
Hamare boiler ki hiting surfers 7022m2 hai
Tempture 540+_ 5°hai
Sir please efficiency nikalna hai
Fuel consumption and steam generation kitna hota h usko v mention kijiye
Husk 60 ton per hour
135 tph par hour steam generation hota hai
E boiler kitna ton ka bhai
Sir, we know that pressure= force/area but in case of nozzle area decrease at the mouth but how pressure decrease and velocity increase
Learn about pressure in fluids and Bernoulli's equation. Your confusion will be clear.
This cfbc boiler make & specifications?
Thyson kurup, 135 tph