How to operate Foxtrot-9 tutorial, How to operate it and connect auxiliary grid (READ DESC)

Поделиться
HTML-код
  • Опубликовано: 12 сен 2024
  • This video contain portuguese language, some texts may be on portuguese.
    How to operate Foxtrot-9 tutorial.
    1: Reactor has rods, they're used for heating or cooling the reactor, and make it less reactive, From 100% to 0%, the less percentage, the more it will heat, and it will make more pressure.
    WARNING: rods may fault and stop operating or cause a nuclear fission explosion.
    2: You can change the speed and continous mode of the rods, it's on the reactor settings.
    3: The Reactor has converters wich change the pressure into power, used to feed the grid, they can be turned on and off, but will disable syncronization.
    4: The reactor has relief valves, that may cool down the reactor once activated, they can be used to control the sectors heat.
    5: Annunciators, they will show warnings, like critical pressure and other important things like rod fault.
    6: Safety system, may protect the reactor from exploding, using the scram mode, it can fail and make the reactor still explode, cannot be disabled normally.
    7: The reactor has cooling pumps that may increase the pressure, the water, and lower the heat.
    8: Reactor has the scram button, once activated , will activate all the relief valves, and will make the rods fall and fix the rod that is on vault, and once everthing leaves unsafe (orange level), the scram can be reseted, may save you from the explosion.
    9: thermal loop, dont. just dont touch.
    How to make the Foxtrot-9 connect Primary/aux (acually you can use all grids) grid tutorial:
    1: Turn all relief valves on.
    2: Slowy remove the rods from the reactor, Without letting the neutrons pass the red (just diable it once reach yellow).
    3: once it reach 0%, turn the relief valves off and make sure that the converters are on.
    4: once the converters are making about 9 Thousands Kw/h, start regulating and control the speed of the syncronization.
    5: remenber to make it almost totally stoped in the 0 HZ (wich may have a black half invisible stick to show you where the 0HZ is located at)
    6: DO NOT let the alarm go off more than 30 secs or the safety system will try to turn on the scram button.
    7: The Grid will not disconnect once changed and production may be about 40000
    Or 40 MW, (DMR does the double)
    8:If you're having temperature unstabilizations, set it to 50% insertion and starting putting the rods up and down to you generate flux on the other area that might be shutting down or areas that are overheating because theres diferent temperature, the more yellow, the more reactive, the more blue, the more reactive, green does not react with blue, in case of overheatings use the relief valves in the areas that are too hot, once the temperature is about 200 C or whatever shows to you, make it 45% of insertion, The temp and pressure stabilizes once you connect the grid, because the facility put force at the alternating converters, making reactor loss pressure, so what you really will need to care is the heat, DONT get the insertion bellow 40% and leave the room, Due to 40% have a good chance of overheating a part and scram, once you want leave the room put 45% or 50%
    Thanks to: / @siko7275
    From helping me with the syncronization tutorial, to i make a even better video
    His video: • How to sync and keep t...
    The rest of the video i dind't use tutorial, it was pure trying without watching tutorials, and it was first try, because i done it already alot of times (6 times)
    Thanks for watching the video, like if you liked the video and comment if you want to help me with my videos.
    Game: web.roblox.com...

Комментарии • 1

  • @maicoluckmann9754
    @maicoluckmann9754  Год назад +1

    R E A D D E S C R I P T I O N
    Or you will not understand.
    it looks like the roblox " terms" menu, that has pages with thousands of lines.
    But mine still a simplification of the video.