Unimode (ADT) Addressable Fire Alarm System Test 20

Поделиться
HTML-код
  • Опубликовано: 2 окт 2024

Комментарии • 25

  • @ExitSign250
    @ExitSign250 8 лет назад +2

    Nice! Great test

  • @CraigBaker96837
    @CraigBaker96837 8 лет назад

    Well, at least we now know that the messages have a priority index.

  • @radiosnmore1225
    @radiosnmore1225 7 лет назад +1

    When it says attention it sounds like the simplex voice

  • @AlarmSystemTech
    @AlarmSystemTech 8 лет назад

    Nice!

  • @HawkinsWX
    @HawkinsWX 8 лет назад

    The security system voice it Siri

  • @SimplexEAS2019
    @SimplexEAS2019 8 лет назад +1

    You should get a mass notification strobe (blue, amber, etc), so that you won't have to see the white strobe off while it's doing mass notification.

    • @tor94
      @tor94  8 лет назад +1

      +Hunter Cullen (ilovepolice1) I have been thinking about doing that, but it may be some time before I do. I was thinking about system sensor speaker strobes

  • @justnothinghere.109
    @justnothinghere.109 7 лет назад

    The voice Evac sounds good

  • @nesmanmain0001
    @nesmanmain0001 3 года назад

    I have an NFW-50 (MS-9050UD) and cannot get my NGB-12LX to activate the panel after being programmed. Do you know why this might be happening? Also, does the Johnson controls BG101X or whatever it is (adressable bg-10 rebrand) work with the 9050?

    • @tor94
      @tor94  3 года назад +1

      I could not get the Johnson Controls module to work with the MS-9050UD or the ES-50X. Only FireLite or Notifier branded modules (from my experience).

  • @Dave-ji1hv
    @Dave-ji1hv 8 лет назад

    Nice! Subbed!

  • @Brandon_Jarvis
    @Brandon_Jarvis 8 лет назад

    Hey i am a long time viewer and was wanting to know if its possible for me to run a small system off of a ademco vista 20 security panel and if so how?

    • @HenBasketFireAlarms
      @HenBasketFireAlarms 8 лет назад

      Is it connected to a monitoring station? If so, you shouldn't.

    • @Brandon_Jarvis
      @Brandon_Jarvis 8 лет назад

      no its not connected to a monitoring station.

    • @Dave-ji1hv
      @Dave-ji1hv 8 лет назад

      Yes a youtuber by the name DoverDucy has a system running off of a security panel. Go see some of his video's on it. They are a little older.

  • @SafetySecurityAlert
    @SafetySecurityAlert 7 лет назад

    did you really hook it up to the fire department?

  • @FireAlarmNZ
    @FireAlarmNZ 8 лет назад

    Do you have any idea how i could run a 12v voice evac amplifier of a 24v panel? i'm thinking of using a buck converter but I think that might affect the supervisory circuit.

    • @tor94
      @tor94  8 лет назад

      +FireAlarmNZ How much current do you expect is going to that? I would say use a voltage regulator but many of those have a 1.5 amp limit

    • @FireAlarmNZ
      @FireAlarmNZ 8 лет назад

      +tornadofreak1994 I'm only drawing a 10w load so that's 0.7 amps @13VDC will the voltage regulator cause a trouble on the panel?

    • @tor94
      @tor94  8 лет назад

      +FireAlarmNZ it should not. but if you use a voltage regulator, if you draw above the rated amps, the regulator might explode (its happened to me lol)

    • @FireAlarmNZ
      @FireAlarmNZ 8 лет назад

      oh goodness, i bet you almost had a heart attack when you smelled something burning inside the fire alarm panel haha. I just ended up powering it from a separate power supply and just used the panel to monitor the circuit.

    • @tor94
      @tor94  8 лет назад

      +FireAlarmNZ nice! thats the safer way. and it actually made my panel 100% stop working. I replaced it and it works again!