How to Repair Electric Immersion Water Heater at Home in Hindi

Поделиться
HTML-код
  • Опубликовано: 27 июл 2024
  • Hello friends in this video I have shown you that. How to Repair Electric Immersion Water Heater using multimeter and series testing board very easy way. I hope you like this video. keep watching our videos for more knowledge. stay connected with our channel RAJPUT TECHNICAL. If you satisfy this video so please Like & Share. comment below in the comment section. you must Subscribe our channel for more updates and Don't forget press bell Icon for New videos Notification. I hope I will see you again in the next video. Thank's for watching.
    Namaskar dosto iss video me maine bataya hai ki. Electric Immersion Water Heater ki Repairing multimeter evam series testing board ki help se kaise ki jaati hai. ummeed hai ki yeh video aapko pasand aayega. video pasand aane per Like kijiye share kijiye. aur aapki jo bhi rai ho niche comment section me likhiye. naye video ki jaankari aur update pane ke liye aapko hamare channel RAJPUT TECHNICAL ko Subscribe kar lena chahiye. Santh me Naye video ki Notification paane ke liye Ghante ke button ko press kijiye. agle video me fir milenge. video dekhne ke liye dhanybad,
    your queries:
    how to repair water heater
    water heater kaise banaye
    water heater kaise repair karen
    water heater theek karne ka tarikabataye
    kaise sudhare water heater ko
    water heater sudharne ka tarika kya hai
    water heter ko kaise theek karen
    how to repair electric water heater
    how to make water heater
    pani ki rod kaise repair karen
    pani ka heater kaise sudharen
    heater repairing kaise karen
    water heater repairing kaise karen
    water heater coil theek karne ka tarika batayen
    pani ki rod banana batayen
    water heater banana batayen
    electri water heater repair karna sikhayen
    water heater banane ka sahi tarika kya hai
    water heater repairing video
    water heater repair
    water heater repairing
    reparing water heater
    heater repairing
    heater repair
    water heater coil repair
    electric water heater repair
    repair water heater
    water heater wiring video
    #electricimmersionwaterheaterrepair #immersionrodrepair #waterheaterrepair #electri water heater repair #RAJPUTTECHNICAL
    LIKE, SHARE & SUBSCRIBE !!!
  • НаукаНаука

Комментарии • 110

  • @SamsamvelSamu
    @SamsamvelSamu Месяц назад

    Explain very useful well 🎉 thanks 🙏 you for the information

  • @sanjusalunke5256
    @sanjusalunke5256 3 года назад

    Mai jarur check karwake leta hu.thanks sir

  • @richadwivedi8357
    @richadwivedi8357 3 года назад +1

    Good information thank you for giving us these knowledge about water heater

  • @matinkungle1467
    @matinkungle1467 Год назад

    GOOD VIDEO SIR❤

  • @himanishm5363
    @himanishm5363 Год назад

    Nice tutorial.

  • @abduttawwab1446
    @abduttawwab1446 5 лет назад +2

    Superb sir ji
    Bestest information for electrition man

    • @RAJPUTTECHNICALJSR
      @RAJPUTTECHNICALJSR  5 лет назад

      Thank you very much. Keep watching and sharing our videos. Always stay connected with our channel for more knowledge.

  • @sammedvathare7045
    @sammedvathare7045 4 года назад +1

    Thanks sir

  • @saiju4u1
    @saiju4u1 4 года назад

    Very Good Presentation.. Keep it up

  • @salikram6183
    @salikram6183 3 года назад

    Very nice

  • @Muin1509
    @Muin1509 5 лет назад

    Nice imformation....

    • @RAJPUTTECHNICALJSR
      @RAJPUTTECHNICALJSR  5 лет назад

      Thank you very much. Keep watching and sharing our videos. Always stay connected with our channel for more knowledge.

  • @laxmansahu1490
    @laxmansahu1490 2 года назад

    Thank you so much sir 🙏🙏

  • @khushivamchandela9818
    @khushivamchandela9818 4 года назад

    Wow nice information

  • @mdomer3767
    @mdomer3767 4 года назад

    Sir spring ke heater ki wiring ki video banao please please

  • @shrikantbabhulkar1572
    @shrikantbabhulkar1572 4 года назад

    You are a nice person

  • @sunilkumarsingh6128
    @sunilkumarsingh6128 5 лет назад

    good knowledge

    • @RAJPUTTECHNICALJSR
      @RAJPUTTECHNICALJSR  5 лет назад

      Thanks for the appreciation. Keep watching and sharing our videos. Always stay connected with our channel for more

  • @bhavinmaru4024
    @bhavinmaru4024 3 года назад

    Super sir

  • @wakilah6107
    @wakilah6107 5 лет назад

    Nice vedio....

    • @RAJPUTTECHNICALJSR
      @RAJPUTTECHNICALJSR  5 лет назад +1

      Thanks. Keep watching and sharing our videos. Always stay connected with our channel for more knowledge.

  • @rktechnicaltech1114
    @rktechnicaltech1114 5 лет назад

    Nice sir

    • @RAJPUTTECHNICALJSR
      @RAJPUTTECHNICALJSR  5 лет назад

      Thanks. Keep watching and sharing our videos. Always stay connected with our channel for more knowledge.

  • @thatartsylove
    @thatartsylove 2 года назад

    Hi rajput sir ..mera ek sawal h agar ap answer de paye toh bahut khushi hogi.
    Mere electric rod ko jab on karte h toh main power switch down ho jata h ..isme kya problem h aur kya ye repair ho sakta h?

    • @RAJPUTTECHNICALJSR
      @RAJPUTTECHNICALJSR  2 года назад

      Aap ke electric rod mein shorting ho rahi hai open karke check karen wiring mein shorting ho rahi hogi ya fir coil earth ho gai hogi

  • @hellobird8399
    @hellobird8399 11 месяцев назад

    Sir agar chalu rod ko haath lagega to shock legega kya

    • @RAJPUTTECHNICALJSR
      @RAJPUTTECHNICALJSR  11 месяцев назад

      leakage hoga toh shock lagega isliye toh upkaran ki body ko earthing di jati hai hamari safety ke liye aur ghar mein bhi earthing hona jaruri hai tester se check karliya karen aur apni safety ka dhyan rakhen laparvahi na karen dhanyawad

  • @Devendra_Dake
    @Devendra_Dake 11 месяцев назад

    Agar coil ke bodi earthing se heater kam nahi karraha to kay? Bodi earthing hata do to kam kar raha hi.

  • @rktechnicaltech1114
    @rktechnicaltech1114 5 лет назад

    Sir motor ka data nikalna bataye

  • @sonaidas1537
    @sonaidas1537 4 года назад +1

    sir mere pass ak weater heater he lekin jispe arthink ka wear laga raita he wo kho geya he ka koru sir please help kore

  • @ghanshyamtamoli7826
    @ghanshyamtamoli7826 3 года назад

    Dear sir Bina Pani k on karne par immersion raad band ho gaya.. plz solution bata yen.

  • @bediken6797
    @bediken6797 3 года назад

    Heater connecting screw broken but coil ok please tell me how to repair it

    • @RAJPUTTECHNICALJSR
      @RAJPUTTECHNICALJSR  3 года назад

      You can solder the wire connection with the help of soldering iron

  • @Gian.Prakash
    @Gian.Prakash 3 года назад

    Sir.. In my case, wires are ok but issue is with heating coil. Ussey kaisey fix karey? I have checked with multimeter, wo open bta rha hai.
    (By the way I really like your way of explanation.. detailed and to the point. Keep it up!! ☺️)

    • @RAJPUTTECHNICALJSR
      @RAJPUTTECHNICALJSR  3 года назад +1

      Heater coil ke dono siron ko ek bar achhe se emery paper ya file se ghiskar check karke dekhen yadi fir bhi open bata raha hai to heater coil internal open hai use repair nahi kiya ja sakta hai veh replace hogi

    • @Gian.Prakash
      @Gian.Prakash 3 года назад

      @@RAJPUTTECHNICALJSR Ok Sir. Apney samay nikal ke jawab diya. Thank you so much.

  • @LittleGenius399
    @LittleGenius399 4 года назад

    Wire at the heater motor end wire burnt with little fire due to heat
    What to do shall I put cellotape??
    Or it's waste now
    Please reply

  • @hinusingh6089
    @hinusingh6089 3 года назад

    Sir earthing wala wire nahin jode to chalega

    • @RAJPUTTECHNICALJSR
      @RAJPUTTECHNICALJSR  3 года назад

      Earthing wire jodna suraksha ki drasti se bahut hi jaruri hai

  • @constructionwithskills488
    @constructionwithskills488 3 года назад

    Agr ye rod lagae water ma current aa jaye Tu kesy check Kar sakty Hain ? Tester sy ho sakta ha?

    • @RAJPUTTECHNICALJSR
      @RAJPUTTECHNICALJSR  3 года назад

      Heater mein yadi earthing proper connect nahi hai toh coil mein leakage hone ya fir coil body se short hone per water mein current aa sakta hai aur use tester se check kar sakte hai

    • @constructionwithskills488
      @constructionwithskills488 3 года назад

      @@RAJPUTTECHNICALJSR thnx sir love from Pakistan

  • @SantoshYadav-ov5fr
    @SantoshYadav-ov5fr 4 года назад

    Sir kya coil gum jayega to kharab ho jayega

  • @srajangupta6837
    @srajangupta6837 Год назад

    Sir, when I am switching on my heating rod the main MCB of my home gets trip off...I checked the wires, everything is fine but why home MCB gets trip off ?

    • @RAJPUTTECHNICALJSR
      @RAJPUTTECHNICALJSR  Год назад +1

      Aap heating rod ko open karke properly check karen phase neutral wire short ho rahe honge ya fir mains cord short ho rahi hogi

  • @naveengehlot2342
    @naveengehlot2342 7 месяцев назад

    Sir ji roid kam garm ho rahi he sirij me chek karne pr bulb bahut dhima jal raha he kaha problem he plz ans

    • @RAJPUTTECHNICALJSR
      @RAJPUTTECHNICALJSR  7 месяцев назад +1

      Rod ko khol kar wiring connection ko dubara se achhe se chhilkar lagaren aur rod ke upper white chhaar jama ho toh use savdhani se hatayen

    • @naveengehlot2342
      @naveengehlot2342 7 месяцев назад

      @@RAJPUTTECHNICALJSR thanks sir ji

  • @qyumahmad4187
    @qyumahmad4187 4 года назад

    Sir agar phase ki jgha nutreal line break Kar ka di jaya to kiya hoga? Please reply my quire

    • @RAJPUTTECHNICALJSR
      @RAJPUTTECHNICALJSR  4 года назад

      Iss condition mein yadi koi inductive ya resistive lode laga hua hai aur uska switch on hai toh neutral point per bhi phase batane lagega aur upkaran work nahi karega

  • @jaimaakalistudioratanpurma2356
    @jaimaakalistudioratanpurma2356 7 месяцев назад

    Ek side ki coil Garam ho rahi hai dusre side Ki Nahin ho rahi

  • @altafshaikh3771
    @altafshaikh3771 4 года назад

    1 ltr water geyser ka thermostat kitne par set hota hai bhai mera 55 pe select hai pani kuch zyada hi garam horaha hai cut off hone se pahele pani zyada garam hone ki awaz bhi aarahi hai

  • @hemantprajapati1701
    @hemantprajapati1701 4 года назад

    Tawer fan me seed problem. Only 1 seed on,2 & 3 not warking

  • @amitupadhyay1684
    @amitupadhyay1684 4 года назад

    Mr. Rajput yo did not show the cleaning of the rusty terminals of the rod. Could you pl.tell us how did you clean those terminals.

    • @RAJPUTTECHNICALJSR
      @RAJPUTTECHNICALJSR  4 года назад +1

      You can use kerosene oil or thinner emery papper for cleaning those rusty terminals

    • @amitupadhyay1684
      @amitupadhyay1684 4 года назад

      @@RAJPUTTECHNICALJSR thank you

  • @nirmalparihar4368
    @nirmalparihar4368 4 года назад

    Rod jab on ho toh uske Pani Ko hath legaye toh current ayega kya

    • @RAJPUTTECHNICALJSR
      @RAJPUTTECHNICALJSR  4 года назад

      Water heater ki coil mein yadi leakage hoga aur aap ke ghar mein yadi earthing nahi hai toh aap aisa bilkul bhi na karen aap ko shock lag sakta hai

  • @moviesfunny110
    @moviesfunny110 5 лет назад

    Maltimeter konsa lena chahiye....

    • @RAJPUTTECHNICALJSR
      @RAJPUTTECHNICALJSR  5 лет назад

      Aap ko kya kya Function chahiye uske hisab se kisi bhi brand ka le sakte hai. yadi aap naye hai toh aap abhi DT830D jo ki simple multimeter hai use le sakte hai.

  • @sudeepmarajakke2386
    @sudeepmarajakke2386 4 года назад

    Sudhir marajakke shri vidya sagar iti clg borgov

  • @nayanranjandash2883
    @nayanranjandash2883 5 лет назад +1

    Bhaiya is bade bale screwdriver ka number Kya hai????

  • @JugalKishor001
    @JugalKishor001 3 года назад +1

    Is bajaj immersion rod good?

    • @RAJPUTTECHNICALJSR
      @RAJPUTTECHNICALJSR  3 года назад +1

      Yes

    • @JugalKishor001
      @JugalKishor001 3 года назад +1

      @@RAJPUTTECHNICALJSR thanks for the answer
      I have one more question why my neon tester is slightly lighting even after switch off position when I put it in the socket?
      There is no phase neutral wrong side problem Plz reply

  • @armanterani5178
    @armanterani5178 4 года назад

    Aarman Terani

  • @vinodraypremjibhaigohel6029
    @vinodraypremjibhaigohel6029 4 года назад

    When I switch on the geyser, mcb tripped, I checked my geyser at electric shop, but it is OK. I changed my mcb, too. Sir answer me please, quickly

    • @riyazmohammed5444
      @riyazmohammed5444 4 года назад +1

      Ur MCB rating may be lower than the geyser rating.. please check

    • @lithosnayak7726
      @lithosnayak7726 3 года назад

      @@riyazmohammed5444 i think so

  • @Devendra_Dake
    @Devendra_Dake 11 месяцев назад

    Aadhi adhuri jankarari darahebho📌 Jis bareme tum kuda hi nahi jante usbareme tumse puchna kay

  • @alleylibrary8508
    @alleylibrary8508 4 года назад

    Jb mai heater ke coil ko circuit se connect krta hu to short circuit hoti hai...kya issue. Hai...?

    • @RAJPUTTECHNICALJSR
      @RAJPUTTECHNICALJSR  4 года назад +1

      Aap use open karke check karen wire aapus mein short ho rahe honge

  • @solarlovers8475
    @solarlovers8475 5 лет назад

    bhai ks company ka ya acha hota ha

    • @RAJPUTTECHNICALJSR
      @RAJPUTTECHNICALJSR  5 лет назад +1

      Aap kisi bhi reputed company ka ISI mark wala Immersion water heater use kar sakte hai sabhi achhe hote hai. Thanks for watching.

  • @tfcdelhi
    @tfcdelhi 3 года назад

    🤔 samajh nahi aa raha ki tum theek kar rahe ho ya check kar rahe ho..... Hhhhhhh

  • @shaistafayyaz116
    @shaistafayyaz116 3 года назад

    .

  • @tappannmhnt
    @tappannmhnt 4 года назад

    arey guru, mera upar se tube hi puncture ho gaya hai!!! ab kya karen

  • @rahulvhatkar
    @rahulvhatkar 3 года назад +1

    Earthing clip is made up of metal. Why doesn't it cause shorting of live and neutral?

    • @RAJPUTTECHNICALJSR
      @RAJPUTTECHNICALJSR  3 года назад +1

      Because heater coil inside the metal cover there are no contact between the heater coil and metal cover. Earthing clip connected with metal cover therefore no shorting of live and neutral.

    • @Devendra_Dake
      @Devendra_Dake 11 месяцев назад

      Agar coil ke bodi earthing se heater kam nahi karraha to kay? Bodi earthing hata do to kam kar raha hi.

  • @GaneshDas-jy8ew
    @GaneshDas-jy8ew 4 года назад

    Baar baar jal raha hai ..cable..kyu ?

  • @SantoshYadav-ov5fr
    @SantoshYadav-ov5fr 4 года назад

    Please reply

  • @hit4144
    @hit4144 4 года назад

    sir rod ko clining kese kare

  • @sanjusalunke5256
    @sanjusalunke5256 3 года назад

    Mai jarur check karwake leta hu.thanks sir

  • @ayubkhanmohammad8852
    @ayubkhanmohammad8852 4 года назад

    Nice sir

  • @yatishsonkeriya2783
    @yatishsonkeriya2783 4 года назад

    Thanks sir

  • @SantoshYadav-ov5fr
    @SantoshYadav-ov5fr 4 года назад

    Sir kya coil gum jayega to kharab ho jayega rod

    • @RAJPUTTECHNICALJSR
      @RAJPUTTECHNICALJSR  4 года назад

      Coil ki body se coil ke contact point per shorting nahi batana chahiye aur coil ke dono terminal per kuchh reading show karna chahiye low value mein